This is a Statement of Need for a federal contract opportunity to drop test and certify fire-rated rollup doors. The project, titled Fire Door Drop Test/Certification B971 (WT# 16559898), requires the contractor to drop test and certify six 14'x 14' fire-rated rollup doors located in building 971. The work must be performed by a certified fire-rated door technician and includes visual inspection, operating mechanism verification, drop testing, reset verification, and comprehensive documentation. Upon completion, the contractor must provide a detailed list of any deficiencies identified and submit a quote for remediation of those issues.
The contractor is responsible for furnishing all labor, equipment, tools, materials, and supervision necessary to complete the work. All activities must comply with Federal, State, and Local Code requirements, including the National Standard Plumbing Code (NSPC), National Electrical Code (NEC), ASHRAE standards, OSHA regulations, National Fire Protection Agency (NFPA) standards, and Unified Facilities Criteria (UFC) codes. The contract also requires adherence to environmental laws and regulations, with proper disposal of any construction debris. The document was current as of August 26, 2025.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF NEED
Project Name: Fire Door Drop Test/Certification B971
WT# 16559898
Current as of: 26 August 2025
1. GENERAL DESCRIPTION
The contractor shall provide all labor, equipment, tools, material, supervision, and any other items necessary to properly drop test and certify 6 14’x 14’ fire rated rollup doors in building
971. The work involves a series of steps to ensure the door’s automatic closing system functions correctly during a fire emergency. To include visual inspection, operating mechanism check, drop test, reset verification, and documentation. The contractor shall comply with Federal, State, and Local Code requirements, as well as the NSPC (National Standard Plumbing Code), NEC (National Electrical Code), ASHRAE, Heating Ventilation Air Conditioning standards, and Occupational Safety and Health Administration (OSHA), National Fire Protection Agency (NFPA), and Unified Facilities Criteria (UFC) codes and standards. All work must comply with environmental laws and regulations, including proper disposal of construction debris.
2. SCOPE
The work covered by this contract will include:
1. DROP TESTING AND CERTIFICATION:
i. All work must be done by a certified fire rated door technician.
ii. Technicians will follow all steps and standards necessary to drop test and certify these doors.
iii. Upon completion of the testing, the contractor will provide a list of any deficiencies as well as a quote to fix any issues.