This document is a salient characteristics specification for a Manual Blast Cabinet System required for Facility 721. The contractor must provide a complete blast cabinet system with specific dimensions of 26" deep by 36" wide by 28" high, constructed from #14 gauge steel with a 1,000 lb. capacity perforated steel floor. The blast enclosure includes a dual-panel swing door with OSHA interlock on the right side, a 14" x 22" safety-glass viewing window with rounded corners, two 16W LED flood lamps providing 1,280 lumens each, and ergonomic 8" glove rings with arm rest and positive seal. The system must include a manual blow-off gun that is OSHA-compliant and an 18" wide pneumatic foot treadle.
The suction blast media delivery system comprises a 1 cubic foot media storage hopper, front-mounted ½" modular piping with pressure regulator and gauge, a general-purpose filter with sight glass and manual drain, an MH-2 long-handle blast gun with 5/16" ceramic nozzle, and an SAR-2 media flow regulator. The media recovery and dust collection system includes a 600 cfm externally tunable cyclonic reclaimer, 8' media recovery hose (4" diameter) and 11' dust hose (6" diameter), a 600 cfm cartridge dust collector (CDC-6), and a 1½ hp blower on the clean air side with minihelic gauge, 16-gallon dust drum, and pushbutton reverse-pulse filter cleaning. All electrical work must be completed by a licensed electrician and comply with the 2023 edition NFPA 70 National Electric Code. The system requires 13 amps at 230 volts, 60 Hz, single phase for the blower motor, and 37 scfm of clean, dry air at 80 psi with a 40°F dew point.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient characteristics Manual Blast Cabinet System – Facility 721
1.0. DESCRIPTION OF EQUIPMENT CHARACTERISTICS . The contractor shall provide a Manual Blast Cabinet System with the following specifications and components.
1.1. EQUIPMENT SPECIFICATIONS
1.1.1. Blast Enclosure
Feature Description
Dimensions 26" deep x 36" wide x 28" high
Construction #14 gauge Steel Cabinet
Access Door (1) 20" deep x 22" high Dual Panel Swing Door with OSHA Interlock (Right Side)
Viewing Window 14" x 22" Safety-Glass with Rounded Corners and tool-free replacement
Operator Access Ergonomic 8" Glove Rings with Arm Rest and Positive Seal
Lighting (2) 16W LED Flood Lamps (1,280 lumens each)
Floor 1,000 lb. capacity, 3/16” thick Perforated Steel
Utility Manual Blow-Off Gun (OSHA-Compliant) and 18" wide Pneumatic Foot Treadle
1.1.2. Suction Blast Media Delivery
Component Description
Hopper 1 cubic foot Media Storage Hopper
Controls Front-Mounted ½” Modular Piping with Pressure Regulator, Gauge, and Blast Control Valve
Filtration General Purpose Filter with Sight Glass and Manual Drain
Blast Gun MH-2 Long-Handle Blast Gun with 5/16” Ceramic Nozzle
Flow Regulator
SAR-2 Media Flow Regulator with Clean-Out Plug
1.1.3. Media Recovery & Dust Collection
Component Description
Reclaimer 600 cfm Externally Tunable, Cyclonic Reclaimer
Hoses 8' Media Recovery Hose (4" dia.) and 11' Dust Hose (6" dia.)
Dust Collector 600 cfm Cartridge Dust Collector (CDC-6)
Blower 1 ½ hp Blower (clean air side)
Features Minihelic Gauge, 16-Gallon Dust Drum, Pushbutton Reverse-Pulse Filter Cleaning
1.3. CERTIFICATIONS, STANDARDS, & REQUIREMENTS
Requirement Specification
Certifications All electrical work to be completed by a licensed electrician.
Standards All electrical work will comply with the 2023 edition NFPA 70 National Electric Code
(NEC).
Electrical Power
13 Amps at 230 volt, 60 Hz, 1 phase (for 1 ½ hp Blower Motor)
Blast Air 37 scfm clean, dry air at 80 psi with 40°F dew point (See Appendix 1)
Salient characteristics