This document is an attachment titled "Salient Characteristics" that provides detailed technical specifications for the Power Converter Model 320LSX (or equal) required under the related federal contract opportunity.
The attachment outlines the key output ratings, power source specifications, and AC input power requirements for the power converters. It specifies the required output voltage, current, frequency, regulation, distortion, ripple, and response time. Additionally, it lists the standard features of the power converter, including interfaces, waveform library, and programmable output impedance. The document states that "Equal Products will SUFFICE" the requirement.
The related federal contract opportunity is for the purchase of 2 Power Converter Model 320LSX (or equal) that meet the detailed specifications provided in this attachment and another attachment referenced. The solicitation is issued by the Department of the Air Force Special Operations Command.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics/Specifications
Power Converter Model 320LSX (or Equal)
320 LSX Models Output Ratings
1. Rated Power (VA): 2000
2. Output Form: 1.2 - 3
3. Output Voltage Max - Direct: 150/300 – 150/260
a. Transformer:
i. Ratio 1.5:1: n/a – n/a
ii. Ratio 2.0:1: n/a – n/a
iii. Ratio 2.5:1: n/a – n/a
4. Output Current – Direct: 20/12 – 7/ ø
a. Transformer:
i. Ratio 1.5:1: n/a – n/a
ii. Ratio 2.0:1: n/a – n/a
iii. Ratio 2.5:1: n/a – n/a
LSX Power Source Specification
1. Output Frequency:
a. Full Power 15-1200 Hz Direct Coupled 45-1200 Hz Transformer Coupled
2. Line Regulation
a. 0.1% max for a ± 10% line change
3. Load Regulation
a. Direct Coupled Ranges: 15 to 200 Hz < ± 0.25% - 200 to 1200 Hz < 0.5%
4. Output Distortion (VTHD)
a. 15 to 200 Hz < ± 0.25% - 200 to 1200 Hz < F* 0.7 + 0.11%
5. Ripple and Noise
a. < 66 dB
6. Response Time
a. 60 msec typ. For a 10-90% load step
AC Input Power Requirements (47-63 Hz)
Input Voltage: 100 Vac ±10% 110 Vac ±10% 120 Vac ±10% 200 Vac ±10% 208/220 Vac ±10%
230/240 Vac ±10%
AC Input Current: 22 Arms 20 Arms 18 Arms 10 Arms 10 Arms 9 Arms
Recommended Input Service:
25A 25A 25A 15A 15A 15A
Standard Features:
1. Single phase output from front panel or bus command.
2. 15 to 1200 Hz. Operation – 5000 Hz small signal bandwidth.
3. Precision Voltage Programming – 0.05% with Continuous Self-Calibration (CSC) engaged.
4. True-RMS metering of volts, amps, and power.
5. LAN, USB, GPIB & RS232 Interfaces standard
6. Waveform Library – Arbitrary Waveform Generator.
7. 200 stored programs with associated transients for static and dynamic test applications.
8. Programmable Output Impedance
9. Harmonic Analysis and Waveform Synthesis
10. Current Inrush Capture and
11. Waveform Analysis
Equal Products will SUFFICE