Attachment 1 - Salient Characteristics 36 MXS LOX Purge Unit.pdf
PDF 165 KB Posted
- Attached to
- 36 MXS LOX Purge Unit
- Solicitation number
- FA524025QM151
About this file
This document is a Requirement Description with Salient Characteristics for a Liquid Oxygen (LOX) Purge Unit issued by the Department of the Air Force at Andersen Air Force Base in Guam. The detailed specification outlines precise physical, performance, and operational requirements for the equipment, including dimensions of 78 inches length, 54 inches width, and 48 inches height, with a weight of approximately 1,400 pounds. Critical performance specifications include a flow rate of 6 pounds per minute, discharge pressure of 0-5 PSIG, and an outlet temperature of 350±10 °F.
The unit requires electrical specifications of 440V/220V, 3-phase, 60-cycle power, with a 5 hp motor and 12 kilowatt heater. Environmental operating parameters are extensive, with the ability to function in temperatures ranging from -65 to 130 °F and storage temperatures from -80 to 160 °F. Additional capabilities include forklift slots, tie-down rings, and pintle hook towing features, along with a minimum service hose length of 10 feet and a power cable length of 50 feet. The suggested part number is NSN - 3655-01-561-4006 or an equivalent, indicating flexibility in manufacturer selection while maintaining strict performance standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 2 - Provisions and Clauses 36 MXS LOX Purge Unit.pdf | ||
| RFQ 36 MXS - LOX Purge Unit.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
HEADQUARTERS 36TH WING (PACAF)
ANDERSEN AIR FORCE BASE GUAM
(In detail, please describe those physical, functional, performance, or material element
REQUIREMENT DESCRIPTION WITH SALIENT CHARACTERISTICS
Suggested Part Number: NSN - 3655-01-561-4006 or Equal
Physical Characteristics:
Length 78 inch Width 54 inch Height 48 inch Weight approx. 1400 pounds Service Hose Length Min: 10 feet Power Cable Length Min: 50 feet Lift Capabilities Forklift slots, tie-down rings, and pintle hook towing capabilities
Performance Characteristics must precisely meet the following:
Flow Rate 6 pounds per minute Discharge Pressure 0-5 Pound-force per Square Inch, Gauge (PSIG) Outlet Temperature 350±10 °F Environmental Characteristics Operating Temperature -65 to 130 °F Storage Temperature -80 to 160 °F Relative Humidity N/A
Operating Characteristics of motor and heater:
Voltage 440V/220V, 3 phase, 60 cycle Motor 5 hp 440V/4.5 Ampere (amps); 220V/9 amps Heater 12 Kilowatts (kw) 440V/21 amps 220V/27 amps
File details come from the government source that posted it. Updated .