This document is a Requirement Description with Salient Characteristics for Water Stations procurement. The government requires six water refill stations to be installed at four designated buildings: Bldg 61230, Bldg 61250, 736 SFS Sharetech Bldg, and 736 Contingency Response Bay 61228.

The water stations must meet specific functional and performance requirements including ADA compliance, a recessed dispenser to eliminate cross-bottle contamination, and the ability to chill water between 40-42 degrees Fahrenheit with an internal drainage system. Required certifications include NSF/ANSI 42, 53, 58; ISO09001; and NSF AMSI 372, 61, 51. Each system must incorporate a multi-filter/purification system removing up to 99% of tap water impurities, a foot pedal option for hands-free operation, and a secondary trigger mechanism for sensor failure backup. The stations must be energy efficient, removable and relocatable, require only a water line, drain line, and 110-volt receptacle connection, and occupy no more than three square feet of floor space. All installed materials must be fully operational and meet required codes, with work completed to minimize downtime for existing business operations and requiring vendor base access capability.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUIREMENT DESCRIPTION WITH SALIENT CHARACTERISTICS

In detail, please describe those physical, functional, performance, or material element qualities of an item that are essential to ensure that the intended use of the item can be satisfactorily realized.

Text1: Water Stations
Text2: 1. Must be ADA compliant

2. Must have recessed dispenser to eliminate cross bottle contamination

3. Must have ability to chill water between 40-42 degrees Fahrenheit

4. Must have internal drainage system

5. Must have the following certifications:

a. NSF/ANSI 42,53,58

b. ISO09001

c. NSF AMSI 372,61,51

6. Must be energy efficient

7. Must have a multi-filter/purification system that removes up to 99% of tap water impurities.

8. Vendor must be able to obtain base access

9. Shall have secondary trigger to dispense water in case sensor is inoperable

10. System must be a removable & relocatable water bottle station.

11. Must not require mounting or attachment to building.

12. Must be a standalone system requiring only water line, drain line, and a 110volt receptacle.

13. System must also have a foot pedal option for hands free use.

14. System must be able to fit into compact areas and take up no more than three square feet in floor space

15. 6 Total water stations

17. The contractor will install the water refill stations at the following Buildings:

- Bldg 61230

- Bldg 61250

- 736 SFS Sharetech Bldg

- 736 Contingency Response Bay 61228

18. All new installed material items are to be fully operational and meet all required codes.

19. Work shall be completed as to limit the down time for existing business operations.