Attachment 1 - Purchase Description.pdf
PDF 949 KB Posted
- Attached to
- Multichannel chronic microwire brush arrays Federal contract opportunity
- Solicitation number
- 75N95024Q00424
About this file
This document is a Purchase Description and related Federal Contract Opportunity for Multichannel Chronic Microwire Brush Arrays.
The National Institute of Mental Health (NIMH) requires the purchase of 25 multichannel microwire brush arrays with varying wire lengths to conduct longitudinal electrophysiology and functional magnetic resonance imaging experiments. The Purchase Description provides salient characteristics for the required brand name or equal products. The related Federal Contract Opportunity solicits proposals for these products under full and open competition, with a fixed-price purchase order anticipated. Proposals will be evaluated on technical capability, contract management, delivery, and past performance, with price as a secondary factor. Offers must be submitted electronically by August 28, 2024, and the delivery time is 6-8 weeks after contract award. The North American Industry Classification System (NAICS) code is 334516 - Analytical Laboratory Instrument Manufacturing. The contracting agency is the Department of Health and Human Services, National Institutes of Health, National Institute on Drug Abuse.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 3- FAR 52.212-5 -.pdf | ||
| Attachment 2 - FAR 52.212-4 -.pdf | ||
| Attachment 4- Invoicing Instructions - IPP.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Version 11-30-2016-1 FAR Part 11—Describing Agency Needs
PURCHASE DESCRIPTION
1. Statement of Need and Purpose: Implant chronic multichannel electrode to record the same neural circuits over time with ability to perform fMRI while collecting electrophysiology data.
2. Background Information and Objective: The National Institute of Mental Health (NIMH), Section on Cognitive Neurophysiology and Imaging (SCNI) requires the purchase of multichannel microwire brush arrays for conducting longitudinal electrophysiology and functional magnetic resonance imaging experiments to study the neural circuits associated with sensori-cognitive processing in the brain. In addition to monitoring multiple neurons simultaneously and tracking changes over time, these multichannel microelectrodes were designed to function in combination with functional resonance imaging (fMRI). SCNI is one of only a few groups in the world to employ this convergence of the latest technical methods of electrophysiology and neuroimaging.
Recent advances in electrode technology have improved efficiency in sampling of neural signals by simultaneous measurements across multiple sites as well as allowed for longitudinal sampling of these same sites across durations of weeks and months.
3. Generic Name of Product: Multichannel chronic microwire brush arrays
4. Purchase Description: NIMH requires the following brand name or equal multichannel microwire brush array with varying number of microwire lengths:
MBA-NC-12.5-64-60-5-430-50-REF2-GD2-CONN2
MBA-NC-12.5-64-45-5-430-50-REF2-GD2-CONN2
MBA-NC-12.5-64-40-5-430-50-REF2-GD2-CONN2
Version 11-30-2016-1 FAR Part 11—Describing Agency Needs
5. Salient Characteristics: NIMH requires the following items with the following brand name or equal salient characteristics.
o Multichannel NiChrome with small diameter (example 0.005”) microwires, with polyimide insulation.
o One ground wire extending from connectors ; length variable depending on electrode placement (example: 100mm length) o One reference wire, exposed (a predetermine length example: 2mm) extending from recording wires within the array.
o Ground and reference wires attached to #A70242 MRI Compatible ground and reference connector contacts.
o All multichannel wires (example 32, 64, 128 wires) retrofitted into specified length Microfil tube (example 55mm), with all wires extending beyond the Microfil tube a predetermined length per order specifications.
o MR compatible components
6. Quantity:
25 x Multichannel chronic microwire brush arrays:
13 units - MBA-NC-12.5-64-60-5-430-50-REF2-GD2-CONN2
3 units - MBA-NC-12.5-64-45-5-430-50-REF2-GD2-CONN2
9 units - MBA-NC-12.5-64-40-5-430-50-REF2-GD2-CONN2
7. Delivery Date:
Six to eight weeks after award of contract
Ship to:
Kenji Koyano National Institute of Mental Health 49 Convent Drive Bldg. 49, Room B1C60 Bethesda, Maryland 20892
File details come from the government source that posted it. Updated .