Attachment 1 - Purchase Description.pdf
PDF 328 KB Posted
- Attached to
- Front-Load Aqueous Part Washer Federal contract opportunity
- Solicitation number
- W912LP-24-Q-1013
About this file
This document is an Attachment 1 - Purchase Description for a Request for Quotes (RFQ) issued by the Iowa National Guard for a front-load aqueous part washer and associated items. The Iowa National Guard is seeking to purchase 1 front-load aqueous part washer, delivery and installation services, operator training, and 4 five-gallon buckets of detergent. The part washer must meet specific salient characteristics including features, electrical, size, and performance specifications. The contract will include a 1-year on-site warranty and contractor-provided operator training. Quotes are due by 10:00 am Central time on September 19, 2024. Award will be made to the offeror that meets the minimum salient characteristics at the lowest price. Quotes should be submitted electronically and include completed pricing tables and product literature.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 2 - Provisions and Clauses.pdf | ||
| CSS_W912LP-24-Q-1013.pdf | ||
| Attachment 3 - Contractor Information and Pricing Tables.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 – Purchase Description
Iowa National Guard
RFQ# W912LP-24-Q-1013
You are invited to submit a quote for front-load aqueous part washers and associated items to the Iowa National Guard, Camp Dodge Joint Maneuver Training Center, USPFO-P&C, Bldg.
3475, 7105 NW 70th Avenue, Johnston, IA 50131-1824.
The following items are required:
LINE ITEM #: 0001
ITEM: Front-Load Aqueous Part Washer QUANTITY / UNIT: 1 / Each DESCRIPTION: See salient characteristics below for specifications.
LINE ITEM #: 0002
ITEM: Delivery, Installation, Operator Training QUANTITY / UNIT: 1 / Each DESCRIPTION: See salient characteristics below for specifications.
LINE ITEM #: 0003
ITEM: Detergent (5-Gallon Bucket) QUANTITY / UNIT: 4 / Each DESCRIPTION: See salient characteristics below for specifications.
LINE ITEM #: 0004
ITEM: IUID Label QUANTITY / UNIT: 1 / Each DESCRIPTION: Part washer requires an item Unique Identification label per DFARS
Clause 252.211-7003 – Item Unique Identification and Valuation.
Contractor is responsible for providing IUID labels at the time of delivery.
All specifications for the proposed part washer shall meet or exceed the salient characteristics described below.
SALIENT CHARACTERISTICS (specifications):
1. DESCRIPTION:
This description is for one front-load automatic aqueous part washers to be placed at Field Maintenance Shop (FMS) # 04. Part washer shall be rugged, high capacity using pressurized hot water and industrial detergent to clean parts.
2. FEATURES:
Front Load Parts Washer.
Commercial washing chamber roll in door.
Control panel with low-water indicator light, automatic low-water shut off.
Built in oil skimmer (example: belt driven).
o Oil drain container.
Programable wash-cycle timer, 24 hr. / 7-day heater and skimmer timers.
Rotating turntable with drive system.
Turn table on/off switch.
Vertical wash pump.
Heater: Electrical heating element with wash nozzle(s).
Retractable intermediate spray arm.
Removable debris screen.
Two- tier turntable.
Drop in parts tree.
Small parts basket.
Fork accessible Chip Basket, with forklift accessibility for heavy duty equipment parts.
Automatic water fill.
o Water supply located at the current parts washer.
o Water supply attached to the parts washer with standard garden hose fitting.
Parts washers drain and drain-plug for system service.
o System utilizes drain-plug and is not plumbed into building.
o Service drain-plug not less than 1.5-inch circumference.
3. SPECIFICATIONS:
Electrical specification (see delivery location for address):
o 1 each 208 V 3 phase, 60HZ maximum 50 amp.
Equipment size specifications:
o Minimum 48” working height.
o Minimum 36” turntable diameter.
o Minimum 1,000-pound turntable load capacity.
o Minimum of 7 HP pump motor.
o Minimum 110-gallon pump minute (GPM) pump capacity at a minimum of 50 pounds per square inch (PSI).
o Minimum 50-gallon sump capacity.
o Operating temperature of between 150-180 degrees.
o Minimum 36” containment ring.
Parts washer will be reviewed for conformity to ensure standards meet Federal and Iowa applicable directive, regulation, safety, and environmental standards.
4. ADDITIONAL ITEMS:
Four, five-gallon buckets of detergent.
5. WARRANTY:
Shall include one-year on-site warranty that covers all parts and labor.
6. ON-SITE TRAINING:
Contractor shall provide one time operator training at delivery/installation location.
7. DELIVERY AND SET UP:
Contractor shall deliver, install, and train facility personnel on part washer procedures.
o FMS 4 has the capability to assist with unloading from truck and emplace in each facility.
o Installation of part washer at the facility shall be a direct connection to existing voltages/phases hookups. Review the electrical specifications in section-3 above to ensure system is properly installed to Federal and State of Iowa electrical and plumbing code.
o New electrical, plumbing, or footprint preparation is beyond he scope of this acquisition, installation is limited to existing utilities.
Delivery/Install/Training Address:
Facility POC information will be provided with award information.
o FMS 4, 2415 E. Kanesville Blvd., Council Bluffs, IA 51503
////NOTHING FOLLOWS\\\\
File details come from the government source that posted it. Updated .