| DESCRIPTION | PART NUMBER | QTY | Unit | Unit Price | Extended Price | Salient charcterisitcs |
| HUBBELL 15 KV, 600 AMP DISCONNECT | M3C156BP | 3 | EA | |||
| ALUMAFORM FIBERGLASS DEADEND ARM | FDA303496EBFG | 2 | EA | |||
| BURNDY CRIMPING DIE, 250 KCMIL | U29RT | 1 | EA | Must fit Burndy Crimper | ||
| GREENLEE PULLING ROPE, 7/8" X 600' | 34137 | 1 | EA | |||
| 3M TERMINATION KIT, 750 KCMIL | 7695-S-4 | 2 | EA | |||
| 750 KCMIL 15 KV TAPE SHIELD CABLE, 365' REEL | MVE375001 | 3 | EA | |||
| 3M 750 KCMIL SPLICE KIT W/ CONNECTOR | 5516A-750-CU | 3 | EA | |||
| FEDERAL PACIFIC PAD MOUNT SWITCH, PMH-9 | PSI/II-9-44222-A2-B1-B2-B4-G1-G2-K2-K3-S3-T3-T4 | 1 | EA | Dimensions must match the measurements of the concrete pad that is already in place, location of the conduits, and connection point where cable will be terminating | ||
| BURNDY 350 KCMIL, 2 HOLE LUG, STRAIGHT rated for 15KV | YA31-2N | 15 | EA | Must fit Burndy Crimper | ||
| BURNDY 350 KCMIL, 2 HOLE LUG, 90 DEG rated for 15KV | CLNB-350-12-134-9 | 15 | EA | Must fit Burndy Crimper | ||
| HUBBELL DOUBLE ELEMENT TAP LUG | TLD62 | 15 | EA | |||
| HUBBELL 15 KV 3 PHASE BYPASS SWITCH | BP3R1CY | 1 | EA | The location and manner that this switch is going to be installed has been designed based on utilizing this switch. | ||
| 350 KCMIL COPPER WIRE, BLACK THHN, BY THE FOOT | 100 | EA | ||||
| 250 KCMIL COPPER WIRE, BLACK THHN, BY THE FOOT | 500 | EA | ||||
| BURNDY 250 KCMIL, 2 HOLE LUG rated for 15KV | YA29-2N | 9 | EA | Must fit Burndy Crimper | ||
| ILSCO 250 KCMIL, LONG BARREL CRIMP rated for 15KV | C-250 | 6 | EA | |||
| BURNDY H-TAP CONNECTOR, 4/0-500 KCMIL | YHN-525 | 6 | EA | Must fit Burndy Crimper | ||
| Connector, Loadbreak, Bimetallic, #2STR & #1 Solid | CC2C04T | 7 | EA | |||
| Loadbreak Elbow, with Test Point, No connector for cable with an insulation diameter of 0.61" to 0.97" | LE215AB00T | 7 | EA | |||
| Cable, 15 KV, Copper Tape Shield, 2/0 AWG, Stranded Copper, ULMV-105, 220 MIL 133% EPR Insulation, PVC outer jacket | MVE32/001 | 175 | EA | |||
| Crimping Die, Burndy, U Style, 2/0 Copper crimp | U26RT | 1 | EA | Must fit Burndy Crimper | ||
| Dielectric Silicone Lubricant | 2605670A02M | 2 | EA | |||
| Splice, Compression, Tin-plated Copper, 2 AWG stranded copper conductors for voltages up to 35KV, color code Brown, 2.82 overall length | YS2C | 7 | EA | |||
| Bushing, End Bell, PVC, 6" for use w/ sch 40 and 80 | E997N | 4 | EA | |||
| Shield Adapter Kit, Loadbreak Elbow, #2-250 KCMIL, 0.83"-1.64" Jacket Diameter | 8460 | 9 | EA | This adapter Kit is to be used with 162LR-B5250 | ||
| Crimping Die, Burndy, U Style, 2/0 Aluminum crimp | U26ART | 1 | EA | Must fit Burndy Crimper | ||
| Standoff, Loadbreak, EPDM, 15KV 200 amp | 215SB | 3 | EA | |||
| Loadbreak Junction, 4 point, with bracket, 15KV/200 amp w/ stainless steel mounting bracket 24" long, 3.75" high and 7.5" deep | 164J4 | 4 | EA | |||
| Coupling, PVC, Sch 40 and 80, 6" | CARE940R | 4 | EA | |||
| Insulating Cap, Loadbreak, EPDM, 15KV 200AMP | 215ICI | 6 | EA | |||
| Tape, Electrical Splicing, Rubber, 1" X 30', suitable for splicing up to 69KV and terminations up to 35KV | 130C-1X30FT | 2 | EA | |||
| Conduit, PVC, 6", Schedule 40 | CONPVCSCH40600 | 1 | EA | |||
| Splice, Compression, Tin-plated Copper, 2/0 AWG stranded copper conductors for voltages up to 35KV, color code Black, 3.3 overall length | YS26 | 9 | EA | |||
| Cold Shrink Splice Kit for single conductor, Shielded Cable w/ insulation diameter of 0.64" to 1.01", 15KV, typically #2-4/0 AWG | 5513A | 13 | EA | |||
| Loadbreak Elbow w/ test point, for 15KV shielded cable with an insulation diameter of 0.63" to 0.905" includes bimetal connector for 2/0 stranded conductors. | 162LR-B5250 | 9 | EA | This elbow is to be used with 8460 |