Attachment 1 - Mobile Power Pack Specifications.pdf
PDF 74 KB Posted
- Attached to
- Mobile Power Pack for Electromagnetic Current Generators Federal contract opportunity
- Solicitation number
- FA910125QB003
About this file
This document is an attachment to a Request for Quote (RFQ) for a Mobile Power Pack for Electromagnetic Current Generators to be used at Arnold Air Force Base. The specification details the required features of the Mobile Power Pack, including a 6000-amp contact current capacity for both AC and HWDC, 460-volt 60Hz power input, 7% duty cycle, digital meter display, AC and HWDC output, and various control and safety features. The Mobile Power Pack must be new and cannot use refurbished or remanufactured parts. The related federal contract opportunity has the solicitation number FA9101-25-Q-B003 and is being issued by the Department of the Air Force Materiel Command Test Center. The requirement includes shipping the Mobile Power Pack to Arnold Air Force Base and a manufacturer's standard warranty.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Combined Synopsis Soliciation.pdf | ||
| Attachment 2 - Draft Provisions and Clauses.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specification for Mobile Power Pack at Arnold Air Force Base, TN
Arnold Engineering Development Complex (AEDC)
Provide all materials, labor, and equipment necessary to provide a new fully functional Mobile
Power Pack for Electromagnetic Current Generators for AC or HWDC Magnetization.
Refurbished or remanufactured parts are not authorized for this requirement.
This specification is for the procurement of a Mobile Power Pack for electromagnetic current generation for AC and HWDC magnetization, primarily to be used in the inspections of rotating equipment and weldments.
Specifications:
1) Mobile Power Pack with the following features and capabilities:
− Contact current capacity of 6000 amps for both AC and HWDC (Rated with two 30’ of
4/0 cables in parallel)
− 460-volt, 60 Hz power input
− 7% duty cycle.
− Digital Meter display
− Two bus bar connections
− AC and HWDC output
− Momentary push button switch for magnetization
− One touch auto cycle Demag (demagnetization)
− 115-volt 10-amp convenience outlet
− Pulse magnetization option for 1.5 seconds on, 3 seconds off for 30 second cycle
− Four casters, two fixed, two swivel with locks
− Lift Brackets
− Thermal overload circuitry protection
− Infinitely variable current control
− Solid state switching
− Control circuit feedback loop for amperage regulation and repeatability
− 15 ft control pendant
− Flow through cooling
− Hook on back of unit for cable storage.
2) Shipping and Warranty
− Shipping to Arnold AFB
− Manufacturer’s Standard Warranty
File details come from the government source that posted it. Updated .