Attachment 1 - MALLET-BARGE DD FY21 SSOS Price Sheet.xlsx
XLSX spreadsheet 18 KB Posted
- Attached to
- USCG MALLET DRY DOCK AND BARGE REPAIRS FY21
- Solicitation number
- 70Z085-21-Q-P45J6500
About this file
This is a request for quotation for ship repair and maintenance services for the USCGC MALLET, a 75-foot inland construction tender, and an 84-foot construction barge. The Coast Guard is soliciting quotes to perform various repairs and services for the cutter and barge from February to April 2021 at the contractor's proposed drydock facility, which must be within 650 nautical miles of the cutter's homeport of Corpus Christi, Texas. Quotes are due by November 6, 2020. The requirement is set aside for small businesses with a NAICS code of 336611 for ship repair. The solicitation includes an itemized price sheet listing inspection and repair services for hull structures, tanks, propulsion systems, electrical systems, and other shipboard components. The award will be a firm-fixed price contract for the base period of performance.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOS&S
| PRICING SCHEDULE FOR: | COMPANY NAME: |
| USCGC MALLET (WLIC 75304) & BARGE (84002) DRYDOCK AVAILABILITY FY2021 |
| ITEM | DESCRIPTION | UNIT PRICE | UNIT | QTY | EXTENDED PRICE |
| D-001 | Hull Plating (Side Scan), Ultrasonic Testing - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-002 | U/W Body, Preserve (100%) - Tender | $ - 0 | JOB | 1 | $ - 0 |
| O-003 | Hull Plating Freeboard, Preserve – Partial - Tender | $ - 0 | JOB | 1 | $ - 0 |
| O-004 | Hull Plating Freeboard, Preserve “100%” - Tender | $ - 0 | JOB | 1 | $ - 0 |
| O-005 | Hull and Structural Plating (General) - 10.2-Pound Steel, Renew | $ - 0 | JOB | 1 | $ - 0 |
| O-006 | Hull and Structural Plating (General) - 12.75-Pound Steel Plate, Renew | $ - 0 | JOB | 1 | $ - 0 |
| O-007 | Hull and Structural Plating (General) - 15.3-Pound Steel Plate, Renew | $ - 0 | JOB | 1 | $ - 0 |
| O-008 | Hull And Structural Plating (General) - 20.4-Pound Steel Plate, Renew | $ - 0 | JOB | 1 | $ - 0 |
| O-009 | Hull and Structural Plating (General) - 7.5-Pound (3/16") Steel Plate, Renew | $ - 0 | JOB | 1 | $ - 0 |
| O-010 | Hull And Structural Plating (General) - Cracked Steel Welds, Repairs | $ - 0 | JOB | 1 | $ - 0 |
| O-011 | Hull and Structural Plating (General) - Degraded Weld (Steel), Repair | $ - 0 | JOB | 1 | $ - 0 |
| D-012 | Propulsion Shaft Rope Guards, Inspect | $ - 0 | JOB | 1 | $ - 0 |
| O-013 | Appendages (U/W) - Internal, Preserve - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-014 | Voids (Non-Accessible), Leak Test - Tender | $ - 0 | JOB | 1 | $ - 0 |
| O-015 | Voids (Non-Accessible), Internal Surfaces, Preserve | $ - 0 | JOB | 1 | $ - 0 |
| D-016 | Tanks (MP Fuel Service), Clean and Inspect - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-017 | Tanks (Potable Water), Clean and Inspect - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-018 | Propulsion Shafting; Remove, Inspect, and Reinstall | $ - 0 | JOB | 1 | $ - 0 |
| O-019 | Propulsion Shaft Seals, Mechanical Clean and Inspect | $ - 0 | JOB | 1 | $ - 0 |
| D-020 | Propulsion Shaft Seals, Mechanical Overhaul and Inflatable Renew | $ - 0 | JOB | 1 | $ - 0 |
| D-021 | Propulsion Shaft Bearings (External), Check Clearances | $ - 0 | JOB | 1 | $ - 0 |
| O-022 | Propulsion Shaft Bearings (External), Renew | $ - 0 | JOB | 1 | $ - 0 |
| O-023 | Stern Tube Interior Surfaces, Preserve 100% | $ - 0 | JOB | 1 | $ - 0 |
| D-024 | Propellers, Remove, Inspect, and Reinstall | $ - 0 | JOB | 1 | $ - 0 |
| D-025 | Keel Coolers, Clean, Inspect and Hydro | $ - 0 | JOB | 1 | $ - 0 |
| O-026 | Fathometer Transducer, Renew – Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-027 | Fathometer Transducer, General Maintenance | $ - 0 | JOB | 1 | $ - 0 |
| D-028 | Rudder Assembly; Remove, Inspect And Reinstall | $ - 0 | JOB | 1 | $ - 0 |
| O-029 | Rudder(s), Preserve (“100%”) | $ - 0 | JOB | 1 | $ - 0 |
| D-030 | Crossdeck Winch, Inspect and Test - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-031 | Hull Fittings (Mooring and Towing), Inspect and Test - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-032 | Boat Boom, Inspect and Service - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-033 | CG 300 Crane Wire Rope, Renew | $ - 0 | JOB | 1 | $ - 0 |
| D-034 | Sewage Holding Tank(s), Clean and Inspect - Tender | $ - 0 | JOB | 1 | $ - 0 |
| O-035 | Tanks (Sewage Holding), Preserve “100%” - Tender | $ - 0 | JOB | 1 | $ - 0 |
| O-036 | Tanks (Sewage Holding), Preserve “Partial” - Tender | $ - 0 | JOB | 1 | $ - 0 |
| O-037 | Tanks (MP Fuel Service), Preserve “Partial”- Tender | $ - 0 | JOB | 1 | $ - 0 |
| O-038 | Tanks (Potable Water), Preserve “100%” - Tender | $ - 0 | JOB | 1 | $ - 0 |
| O-039 | Tanks (Potable Water), Preserve, Partial, - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-040 | Cathodic Protection, Zinc Anodes, Renew, - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-041 | Drydock - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-042 | Temporary Services, Provide | $ - 0 | JOB | 1 | $ - 0 |
| D-043 | Sea Trial Performance, Support, Provide | $ - 0 | JOB | 1 | $ - 0 |
| D-044 | Hull Plating (Side Scan), Ultrasonic Testing - Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-045 | U/W Body, Preserve (100%) - Barge | $ - 0 | JOB | 1 | $ - 0 |
| O-046 | Hull Plating Freeboard, Preserve – Partial - Barge | $ - 0 | JOB | 1 | $ - 0 |
| O-047 | Hull Plating Freeboard, Preserve “100%” - Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-048 | Voids (Non-Accessible), Leak Test | $ - 0 | JOB | 1 | $ - 0 |
| O-049 | Voids (Non-Accessible), Internal Surfaces, Preserve | $ - 0 | JOB | 1 | $ - 0 |
| D-050 | Tanks (MP Fuel Service), Clean and Inspect - Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-051 | Tanks (Potable Water), Clean and Inspect - Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-052 | Barge, Diesel Engine Exhaust Piping, Commercial Clean | $ - 0 | JOB | 1 | $ - 0 |
| O-053 | Fathometer Transducer, Renew – Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-054 | Fathometer Transducer, General Maintenance – Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-055 | Spuds, Overhaul - Barge | $ - 0 | JOB | 1 | $ - 0 |
| O-056 | Spud Wells, Preserve - Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-057 | Spud Wells, Inspect - Barge | $ - 0 | JOB | 1 | $ - 0 |
| O-058 | Tanks (MP Fuel Service), Preserve “Partial”- Barge | $ - 0 | JOB | 1 | $ - 0 |
| O-059 | Tanks (Potable Water), Preserve “100%” - Barge | $ - 0 | JOB | 1 | $ - 0 |
| O-060 | Tanks (Potable Water), Preserve, Partial, - Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-061 | Decks – Exterior (Buoy or Construction Deck), Preserve 100% | $ - 0 | JOB | 1 | $ - 0 |
| D-062 | Cathodic Protection, Zinc Anodes, Renew, - Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-063 | Drydock - Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-064 | Deck Covering (Interior Wet/Dry), Renew | $ - 0 | JOB | 1 | $ - 0 |
| O-065 | Lead-Based Paint and Asbestos-Containing Material, Perform Spot Abatement | $ - 0 | JOB | 1 | $ - 0 |
| D-066 | Lead-Based Paint, Perform Spot Abatement | $ - 0 | JOB | 1 | $ - 0 |
| O-067 | Propeller, Minor Repairs and Reconditioning, Perform | $ - 0 | JOB | 1 | $ - 0 |
| D-068 | Compressed Air Receivers and System Valves (All), Clean, Inspect, Hydro and Lift - Tender | $ - 0 | JOB | 1 | $ - 0 |
| D-069 | Compressed Air Receivers and System Valves (All), Clean, Inspect, Hydro and Lift - Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-070 | Hull Fittings (Mooring and Towing), Inspect and Test - Barge | $ - 0 | JOB | 1 | $ - 0 |
| D-071 | Sea Strainers (All Sizes), Overhaul | $ - 0 | JOB | 1 | $ - 0 |
| D-072 | Fuel Valves, Renewal | $ - 0 | JOB | 1 | $ - 0 |
| D-073 | Switchboard Circuit Breakers, Inspect and Repair/ Replace | $ - 0 | JOB | 1 | $ - 0 |
| D-074 | Compartment Insulation, Renew | $ - 0 | JOB | 1 | $ - 0 |
| D-075 | Air Conditioning Plant, System Groom | $ - 0 | JOB | 1 | $ - 0 |
| D-076 | Galley Range, Replace | $ - 0 | JOB | 1 | $ - 0 |
| D-077 | Bridge Light Control Box, Repair | $ - 0 | JOB | 1 | $ - 0 |
| D-078 | Door Framing (External), Renew | $ - 0 | JOB | 1 | $ - 0 |
| D-079 | External Doors, Inspect and Repair | $ - 0 | JOB | 1 | $ - 0 |
| D-080 | Crew Racks, Renew or Repair | $ - 0 | JOB | 1 | $ - 0 |
| D-081 | Watertight Hatch (Barge), Renew | $ - 0 | JOB | 1 | $ - 0 |
| D-082 | Vertical Ladder, Renew | $ - 0 | JOB | 1 | $ - 0 |
| D-083 | Chill Water Piping Insulation, Renew | $ - 0 | JOB | 1 | $ - 0 |
| D-084 | Fire Pump Foundation, Renew | $ - 0 | JOB | 1 | $ - 0 |
| O-00A | Composite Labor Rate | $ - 0 | Hour | 970 | $ - 0 |
| D-00B | GFP Report | NSP | EA | NSP | |
| O-00Z | Laydays | $ - 0 | Day | 5 | $ - 0 |
| M-00A | Contractor Markup Rate for Growth Work = G&A + Profit (In Percent) | % | |||
| Total Price of Definite Items: | $ - 0 | ||||
| Total Price of Option Items: | $ - 0 | ||||
| TOTAL PRICE (Of DEFINITE & OPTION ITEMS): | $ - 0 | ||||
| *** Please CHECK & VERIFY all price submittals for completeness & accuracy. *** | |||||
| Pricing must include any and all Travel and Related Expenses. |
&"Arial,Bold"&14&UUSCG MALLET (WLIC 75304) & BARGE (84002)
RFQ NO: 70Z085-21-Q-P45J6500
&8Page &P of &N
File details come from the government source that posted it. Updated .