ATTACHMENT 1 FOR SOLICITATION HC101322QA357
1. START A DEDICATED SERVICE AT 10 GBPS ETHERNET - PRIVATE LINE SERVICE
(E-PLS) USING TELCO OPTICAL TRANSMISSION NETWORK FROM DHS ROUTER
LOCATED IN DHS CAGE 40560 AT EQUINIX DATA CENTER (DA6) 1950 N.
STEMMONS FWY, DALLAS, TX 75207 TO IDAHO NATIONAL LABS, BLDG
ENGINEERING RESEARCH OFFICE BLDG (EROB), 2525 FREMONT AVENUE, IDAHO
FALLS, ID, 83415. 2. SERVICE MUST BE DEDICATED, NON-ROUTED, 10 GBPS E-PLS
PLACED OVER TELCO OPTICAL TRANSMISSION NETWORK (OTN). 3. DHS WILL
ACCEPT EARLIEST SERVICE DATE POSSIBLE FOR DELIVERY OF SERVICE.
SERVICE URGENTLY NEEDED. 4. THIS SERVICE IS NOT TO BE PLACED ON ANY
DISN/DODIN TRANSPORT AS IT MUST BE DIVERSE FROM THE DISN/DODIN.
START A DEDICATED SERVICE AT 10 GBPS ETHERNET - PRIVATE LINE SERVICE
(E-PLS) USING TELCO OPTICAL TRANSMISSION NETWORK FROM DHS ROUTER
LOCATED IN DHS CAGE 40560 AT EQUINIX DATA CENTER (DA6) 1950 N.
STEMMONS FWY, DALLAS, TX 75207 TO IDAHO NATIONAL LABS, BLDG
ENGINEERING RESEARCH OFFICE BLDG (EROB), 2525 FREMONT AVENUE, IDAHO
FALLS, ID, 83415. 6. SERVICE MUST BE DEDICATED, NON-ROUTED, 10 GBPS E-PLS
PLACED OVER TELCO OPTICAL TRANSMISSION NETWORK. 7. THERE ARE
MULTIPLE TELCO CARRIERS LOCATED IN THE EQUINIX DA6 N. STEMMONS FWY,
DALLAS, TX AND ALL HAVE INTERCONNECT CAPABILITY WITH THE DHS CAGE
40560 IN DA6 VIA DHS CONTRACT WITH EQUINIX. THAT INTERCONNECT FROM
THE WINNING TELCO CAGE TO THE DHS CAGE 40560 IN THE EQUINIX DA6
FACILITY WILL BE COORDINATED BY DHS/RAYTHEON WITH EQUINIX UNDER
THE EXISTING DHS/RAYTHEON CONTRACT WITH EQUINIX. 8. WINNING TELCO
MUST PROVIDE DHS/MR. BERNARD J. YOCUM JR. AND MR. CURLEE WINGATE
WITH INTERSERVICE SUPPORT AGREEMENT (ISA) IDENTIFYING DHS AS
AUTHORIZED USER OF TELCO SERVICE; PROVIDING TELCO CIRCUIT IDENTIFIER,
AND IDENTIFY PORTS ON TELCOMFIBER TERMINATING PANEL (FTP) IN TELCO'S
EQUINIX CAGE WITH CAGE AND BUILDING NUMBER/ADDRESS TO BE USED BY
DHS TO ARRANGE WITH EQUINIX FOR INSIDE WIRE INSTALLATION AND
MAINTENANCE FROM THE TELCO BUILDING AND CAGE TO THE DHS BUILDING
(DA6) AND CAGE 40560 UNDER THE DHS/RAYTHEON CONTRACT WITH EQUINIX. 9.
TELCO INTERFACE AT EQUINIX DALLAS FACILITY WILL BE SINGLE MODE FIBER,
9.5/125 MICRON, WITH OPTICS WORKING AT 1310NM. 10.VENDOR MUST PROVIDE
LIGHT LEVEL READINGS (DB LOSS) AT THE DEMARC LOCATIONS PRIOR TO
CIRCUIT TURN UP TO THE GOV'T INSURING THE LIGHT LEVELS ARE WITHIN
SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -5 TO -13. 11.DHS POC'S FOR
EQUINIX DA6 DHS CAGE ARE: A. MR. ERIC HAMID OFFICE PHONE: 305-961-3730
CELL PHONE: 786-423-5359 E-MAIL: EHAMID@EQUINIX.COM B. MR. ANDREW ZASO
OFFICE PHONE: 703-434-2907 CELL PHONE: 202-893-0667 E-MAIL:
ANDY.ZASO@ASSOCIATES.CISA.DHS.GOV C. MR. CHRISTOPHER GEISLER CELL
PHONE: 703-965-0832 E-MAIL:CHRISTOPHER.GEISLER@ASSOCIATES.CISA.DHS.GOV
D. MR. RICHARD HERNANDEZ CELL PHONE: 301-524-6149 E-MAIL:
RICHARD.HERNANDEZ@ASSOCIATES.CISA.DHS.GOV E. MR. BERNARD J. YOCUM
JR. OFFICE PHONE: 703-387-6060 CELL PHONE: 703-395-3718 E-MAIL:
BERNARD.YOCUM@ASSOCIATES.CISA.DHS.GOV 12.TELCO HAS TWO DEMARC
LOCATIONS FOR IDAHO NATIONAL LABS, START A DEDICATED SERVICE AT 10
GBPS ETHERNET - PRIVATE LINE SERVICE (E-PLS) USING TELCO OPTICAL
TRANSMISSION NETWORK FROM DHS ROUTER LOCATED IN DHS CAGE 40560 AT
EQUINIX DATA CENTER (DA6) 1950 N. STEMMONS FWY, DALLAS, TX 75207 TO
IDAHO NATIONAL LABS, BLDG ENGINEERING RESEARCH OFFICE BLDG (EROB),
2525 FREMONT AVENUE, IDAHO FALLS, ID, 83415. THE PREFERRED LOCATION IS
THE EROB BLDG, 2525 FREMONT AVE, RM 149, IDAHO FALLS, ID, 83415. IF NO LEC
CAPACITY AVAILABLE AT EROB, THEN TELCO CAN USE BLDG UNIVERSITY BLDG
FOUR (UB4), RM 115, 525 MK SIMPSON BLVD; IDAHO FALLS, ID, 83401. WINNING
TELCO MUST DELIVER SERVICE TO EROB, RM 149 IF AT ALL POSSIBLE. THERE
ARE TWO LECS PRESENT AT BOTH EROB, RM 149 OR UB4, RM 116 PROVIDING LEC
SERVICES. THEY ARE LUMEN-QWEST, AND SYRINGA NETWORKS. EITHER CAN BE
USED. 13.TELCO INTERFACE AT IDAHO NATIONAL LABS, BLDG EROB, S.
REMARKS CONTINUED: 2525 FREMONT AVE, IDAHO FALS, ID WILL BE SINGLE
MODE FIBER, 9.5/125 MICRON, WITH OPTICS WORKING AT 1310NM. 14.VENDOR
MUST PROVIDE LIGHT LEVEL READINGS (DB LOSS) AT THE DEMARC LOCATIONS
PRIOR TO CIRCUIT TURN UP TO THE GOV'T INSURING THE LIGHT LEVELS ARE
WITHIN SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -5 TO -13. 15.DHS POC'S FOR
IDAHO NATIONAL LABS, EROB, 2525 FREMONT AVENUE, IDAHO FALLS, ID, 83415
ARE: A. MR. KEVIN HEMSLEY OFFICE PHONE: 208-526-0507 CELL PHONE: 208-317-
3644 E-MAIL: KEVIN.HEMSLEY@INL.GOV B. MR. CAVRON MORTENSEN OFFICE
PHONE: 208-526-3291 CELL PHONE: 208-557-9593 E-MAIL:
CAVRON.MORTENSEN@INL.GOV 16.CIRCUIT MUST BE TAGGED WITH LOCAL
EXCHANGE CARRIER (LEC) CIRCUIT ID AND LONG HAUL CARRIER ID AT BOTH
SERVICE LOCATIONS. 17.CIRCUIT REQUIRES THE FOLLOWING TECHNICAL
PARAMETERS: A. DATA RATE: 10.0 GBPS PLUS OR MINUS 20 PPM B. FORMAT:
ETHERNET 802.3AW C. FRAMING: ETHERNET 802.3AW D. ELECTRICAL INTERFACE:
OPTICAL, SINGLE MODE, 1310 NM E. IEEE STANDARD: 802.3AW COMPLIANT F.
LINE MUST REMAIN OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY,
SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER. G. REQUEST ONE-HOUR
RESPONSE TIME TURN-AROUND TO REPAIR ONCE TROUBLE CALL HAS BEEN
REPORTED. H. GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE
ENGINEERED INTO THE CIRCUIT. I. SINGLE MODE FIBER TERMINATIONS: SC OR
LC J. NO NETWORK INTERFACE UNIT (NIU). K. DEDICATED PATH L. VENDOR
MUST HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES. M.
VENDOR MUST TEST CIRCUIT END-TO-END FOR 24 HOURS IAW EITHER ITU-T
Y.1564 OR RFC-6815 AND A SERVICE AVAILABILITY OF 99.5% OR BETTER. N.
VENDOR MUST HAVE A 24X7 NETWORK OPS CENTER. O. COMMERCIAL CIRCUIT
WILL BE ACCEPTED BY THE GOV'T BY THE DHS NC PS NETWORK OPERATIONS
CENTER, CORRY STATION, PENSACOLA, FL, COM'L 1-866-645-4357, E-MAIL DL-
NOC_NETWORK@US-CERT.GOV
TESTING PARAMETERS AND THRESHOLDS:
THE FOLLOWING TESTING PARAMETERS SHALL BE MEASURED DURING TEST
AND ACCEPTANCE TESTING 1. SEVERELY ERRORED SECONDS (SES): SHALL BE
LESS THAN 0.2 PERCENT 2. DEGRADED MINUTES (DM); SHALL BE LESS THAN 0.2
PERCENT 3. ERROR FREE SECONDS (EFS): SHALL BE GREATER THAN 99.5
PERCENT 4. LOSS OF BIT COUNT INTEGRITY (LBCI): LOSS OF BIT COUNT
INTEGRITY SHALL BE MONITORED USING TEST EQUIPMENT WHICH CAN DETECT
AND MEASURE THE OCCURENCE OF THE INSERTION OR DELETION OF ONE OR
MORE BITS INTO THE DIGITAL BIT STREAM, OFTEN DEFINED AS PATTERN SLIP. 5.
MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER
THAN 24 HOURS. 6. ROUND TRIP DELAY (RTD) RTD SHALL BE MEASURED OVER
THE 10 GBPS CIRCUIT AND SHALL BE LESS THAN OR EQUAL TO 35
MILLISECONDS. 19.REQUEST TELCO VENDOR PROVIDE ALL LONG HAUL & LEC
CIRCUIT IDENT IFIERS TO DELIVER THE CIRCUIT TO THESE TWO END LOCATIONS
TO MR BE RNARD J. YOCUM JR, EMAIL
BERNARD.YOCUM@ASSOCIATES.CISA.DHS.GOV, P RIOR TO INSTALLTION OF THE
CIRCUIT ALONG WITH ANY ENGINEERING REC ORDS FOR THIS CIRCUIT. 20.THIS
WILL BE A TELECOMMUNICATION SERVICE PRIORITY (TSP) CIRCUIT WITH A
RESTORAL PRIORITY OF 2. TSP ASSIGNED IS TSP0LHDUG-02. FOR DHS DALLAS-
EQUINIX/MR. HAMID, MR. ZASO, MR. GEISLER, MR. HERNANDEZ, & MR. YOCUM: 1.
THIS WILL BE A NEW 10 GBPS E-PLS POINT-TO-POINT (PT-TO-PT) CIRCUIT THAT
WILL BE DELIVERED BY THE WINNING TELCO VENDOR TO THE NEW DHS
EQUIPMENT INSTALLED IN THE DHS CAGE 40560 AT THE EQUINIX DA6 BLDG, 1950
N. STEMMONS FWY, DALLAS, TX 75207. 2. AS SOON AS WE RECEIVE THE
INFORMATION ON THE VENDOR'S CIRCUIT NUMBERS, EQUINIX BLDG FOR THE
TELCO, AND THE PORTS ON THEIR CAGE FIBER TERMINATING PANEL (FTP) TO
USE FOR CONNECTING TO THE TELCO CAGE FOR THIS CIRCUIT, WE WILL PASS
THEM TO YOU. 3. REQUEST YOU PLACE ORDER THROUGH DHS/RAYTHEON
EQUINIX CONTRACT TO HAVE EQUINIX INSTALL SINGLE MODE FIBER JUMPERS
FROM TELCO DEMARC IN BUILDING, U. REMARKS CONTINUED: CAGE, AND
PORTS SPECIFIED BY TELCO TO THE DHS CAGE 40560 IN BLDG DA6 ON FIBER
TERM PANEL (FTP) PORTS TO BE SPECIFIED BY YOU. 4. REQUEST YOU INSTALL
SINGLE MODE FIBER JUMPERS FROM DHS FIBER TERM PANEL (FTP) IN THE DHS
CAGE 40560 AT EQUINIX DA6 ON THE FTP PORTS IDENTIFIED BY YOU FOR THIS
CIRCUIT TO THE DHS ASR1002-HX ROUTER IN THE DHS CAGE 40560 FOR THIS
CIRCUIT. 5. PORT ASSIGNMENT ON ROUTER WILL BE PROVIDED BY OUR DHS
MOE ENGINEERING TEAM STAFF TO YOU. 6. REQUEST YOU ADVISE ALL
ADDRESSEES ON THIS ORDER AS TO WHEN THE TELCO CIRCUIT IS DELIVERED TO
THE EQUINIX FACILITY HOUSING THE TELCO CAGE AND WHEN IN-HOUSE FIBER
CONNECTIONS ARE COMPLETED BETWEEN THE TELCO DEMARC CAGE IN THE
EQUINIX BUILDING TO THE DHS CAGE FTP IN EQUINIX BUILDING DA6 AS WELL
AS THE GOV'T FIBER JUMPERS TO THE DHS MOE ASR1002-HS ROUTER IN THE DHS
CAGE. FOR DOE INL/MR. HEMSLEY, AND MR. MORTENSEN: 1. THIS WILL BE A
NEW 10 GBPS E-PLS POINT-TO-POINT (PT-TO-PT) CIRCUIT THAT WILL BE
DELIVERED BY THE WINNING TELCO VENDOR TO IDAHO NATIONAL LABS,
ENGINEERING RESEARCH OFFICE BLDG (EROB), 2525 FREMONT AVE, RM 149 OR
UNIVERSITY BLVD FOUR (UB4), RM 116. WE MUST AWAIT WORD FROM THE
WINNING VENDOR ON WHERE AND WHO THEY WILL HAVE DELIVER THE
CIRCUIT & WITH WHICH LEC. AS SOON AS WE RECEIVE THE INFORMATION ON
WHICH LEC LOCATION THAT THE VENDOR WILL USE ALONG WITH THEIR
CIRCUIT NUMBER, WE WILL PASS THIS TO YOU. 2. AS SOON AS WE RECEIVE THE
INFORMATION ON THE VENDOR'S CIRCUIT NUMBERS WE WILL PASS THEM TO
YOU. 3. REQUEST YOU INSTALL SINGLE MODE FIBER JUMPERS FROM TELCO
FIBER TERM PANEL (FTP) IN EROB ROOM 149, OR UB4, RM 116 TO THE DHS
ASR1002-HX ROUTER IN EROB, RM 106, FOR THIS CIRCUIT. 4. PORT ASSIGNMENT
ON ROUTER WILL BE PROVIDED BY OUR DHS MOE ENGINEERING TEAM STAFF TO
YOU. 5. REQUEST YOU ADVISE ALL ADDRESSEES ON THIS ORDER AS TO WHEN
THE TELCO CIRCUIT IS DELIVERED TO THE DHS FACILITY AND WHEN IN-HOUSE
GOV'T FIBER V. CONNECTIONS ARE COMPLETED BETWEEN THE TELCO DEMARC
TO THE DHS MOE ASR1002-HX ROUTER IN ROOM 106. (** DEMARC CONT'D **) (SP
A) (PMRY DEMARC POC) MR. ERIC HAMID; (U NCLASS USER)
EHAMID@EQUINIX.COM; (CMCL) 1-305-961-3730; (OFFHRS) 1-786-423-5359 (ALTN
DEMARC POC) MR. ANDREW M ZASO; (UNCLASS USER) ANDY.ZASO@ASS
OCIATES.CISA.DHS.GOV; (CMCL) 1-703-434-2907; (PAGER) 1-202-860-88 42; (OFFHRS)
1-202-893-0667 (SP B) (PMRY DEMARC POC) MR. ERIC HAMID; (UNCLASS USER)
EHAMID@EQ UINIX.COM; (CMCL) 1-305-961-3730; (OFFHRS) 1-786-423-5359 (ALTN
DEMARC POC) MR. ANDREW M ZASO; (UNCLASS USER) ANDY.ZASO@ASS
OCIATES.CISA.DHS.GOV; (CMCL) 1-703-434-2907; (PAGER) 1-202-860-88 42; (OFFHRS)
1-202-893-0667 (SP C) (PMRY DEMARC POC) MR. KEVIN HEMSLEY; (CLASS USER)
HEMSKE@I DAHO.DOE.SGOV.GOV; (UNCLASS USER) KEVIN.HEMSLEY@INL.GOV;
(CMCL) 1 -208-526-0507; (OFFHRS) 1-208-317-3644 (ALTN DEMARC POC) MR.
CAVRON MORTENSEN; (UNCLASS USER) CAVRON.MOR TENSEN@INL.GOV;
(CMCL) 1-208-526-3291; (OFFHRS) 1-208-557-9593 (SP D) (PMRY DEMARC POC) MR.
KEVIN HEMSLEY; (CLASS USER) HEMSKE@I DAHO.DOE.SGOV.GOV; (UNCLASS
USER) KEVIN.HEMSLEY@INL.GOV; (CMCL) 1 -208-526-0507; (OFFHRS) 1-208-317-3644
(ALTN DEMARC POC) MR. CAVRON MORTENSEN; (UNCLASS USER) CAVRON.MOR
TENSEN@INL.GOV; (CMCL) 1-208-526-3291; (OFFHRS) 1-208-557-9593 W.
JUSTIFICATION OF SERVICE REQUESTED: SERVICE IS URGENTLY NEEDED TO
SUPPORT NEW SERVICE BETWEEN THESE LOCATIONS IN ORDER TO ACCESS
CLOUD FACILITIES AND PROVIDE DIVERSITY FOR SERVICES. X. DD FORM 1368:
DD FORM 1368'S (MODIFIED USE OF LEASED COMMUNICATION FACILITIES), OR
EMAIL EQUIVALENT, WILL BE SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW
THE PROCUREMENT GUIDE FOR TELECOMMUNICATIONS BY THE STATION
DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE ON SUBMISSION IS
AVAILABLE AT HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP.
CIRCUIT SPECIFICATIONS: CONUS NO JUMBO FRAME ETHERNET VENDOR WILL
PERFORM ACCEPTANCE TESTING IN ACCORDANCE WITH EITHER RFC-6815 OR
ITU-T Y.1564. VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564
SPECIFICALLY, FRAME SIZES OF 64,128,256,512,1024,1280 AND 1518 BYTES MUST BE
USED. THE TEST MUST VERIFY LENGTH OF RECEIVED FRAMES, INDICATE
NUMBER OF FRAMES DROPPED, NUMBER OF FRAMES RECEIVED OUT OF ORDER,
AND DUPLICATE FRAMES. TESTS MUST BE BI-DIRECTIONAL USING THE SAME
DATA RATE IN EACH DIRECTION. BURST TESTS MUST BE RUN TO DETERMINE
MINIMUM INTERVAL BETWEEN FRAMES THAT CAN BE PROCESSED WITHOUT
FRAME LOSS. A THROUGHPUT TEST IS REQUIRED INDICATING THE FASTEST
RATE AT WHICH TEST FRAMES CAN BE TRANSMITTED WITHOUT FRAME LOSS. A
SEPARATE THROUGHPUT TEST MUST BE RUN WITH FRAMES ADDRESSED TO THE
HARDWARE BROADCAST ADDRESS CONSTITUTING AT LEAST 1% OF THE TEST
STREAM AND BE EVENLY DISTRIBUTED THROUGHOUT THE TEST. Z. CIRCUIT
SPECIFICATIONS CONTINUED: A LATENCY TEST MUST BE RUN FOR A PERIOD OF
NO LESS THAN 120 SECONDS, AND REPEATED NO LESS THAT 20 TIMES. THE TEST
STREAM FOR THE LATENCY TEST SHOULD BE RUN AT THE THROUGHPUT RATE
FOR CORRESPONDING FRAME SIZES FROM THE THROUGHPUT TEST. END TO END
LATENCY WILL BE CALCULATED AS THE AVERAGE OVER THE 20 TEST RUNS.
FRAME LOSS RATE TESTS SHOULD BE RUN AT THE FRAME RATE
CORRESPONDING TO THE MAXIMUM FRAME RATE, AND REDUCED BY 10%
INTERVALS UNTIL THERE ARE AT LEAST TWO CONSECUTIVE RUNS IN WHICH NO
FRAMES ARE LOST.THROUGHPUT TEST RESULTS: PASSING RATE 100% FOR ALL
FRAME BYTE SIZES EXERCISED. FRAME LOSS RATE (%) RESULTS: FRAME LOSS
RATE LESS THAN 0.01% FOR ALL FRAME BYTE SIZES EXERCISED. LATENCY WILL
BE MEASURED WILL BE ACCORDING TO THE FOLLOWING MAXIMUM
TRANSMISSION DELAY FOR ANY CIRCUIT UP TO 500 MILES AIR-MILES IN LENGTH
SHALL BE NO GREATER THAN 13MS ONE-WAY AND ANY POINT-TO-POINT
CIRCUIT LONGER THAN 500 AIR-MILES SHALL BE NO GREATER THAN 50MS ONE
WAY WITHIN THE 48 CONTINENTAL STATES. ANY APS SWITCHOVER SHALL TAKE
LESS THAN 50 MILLISECONDS MONTHLY AVAILABILITY SHALL BE NO LESS
THAN 99.5%.