ATTACHMENT 1 FOR SOLICITATION HC101322QA357

1. START A DEDICATED SERVICE AT 10 GBPS ETHERNET - PRIVATE LINE SERVICE

(E-PLS) USING TELCO OPTICAL TRANSMISSION NETWORK FROM DHS ROUTER

LOCATED IN DHS CAGE 40560 AT EQUINIX DATA CENTER (DA6) 1950 N.

STEMMONS FWY, DALLAS, TX 75207 TO IDAHO NATIONAL LABS, BLDG

ENGINEERING RESEARCH OFFICE BLDG (EROB), 2525 FREMONT AVENUE, IDAHO

FALLS, ID, 83415. 2. SERVICE MUST BE DEDICATED, NON-ROUTED, 10 GBPS E-PLS

PLACED OVER TELCO OPTICAL TRANSMISSION NETWORK (OTN). 3. DHS WILL

ACCEPT EARLIEST SERVICE DATE POSSIBLE FOR DELIVERY OF SERVICE.

SERVICE URGENTLY NEEDED. 4. THIS SERVICE IS NOT TO BE PLACED ON ANY

DISN/DODIN TRANSPORT AS IT MUST BE DIVERSE FROM THE DISN/DODIN.

START A DEDICATED SERVICE AT 10 GBPS ETHERNET - PRIVATE LINE SERVICE

(E-PLS) USING TELCO OPTICAL TRANSMISSION NETWORK FROM DHS ROUTER

LOCATED IN DHS CAGE 40560 AT EQUINIX DATA CENTER (DA6) 1950 N.

STEMMONS FWY, DALLAS, TX 75207 TO IDAHO NATIONAL LABS, BLDG

ENGINEERING RESEARCH OFFICE BLDG (EROB), 2525 FREMONT AVENUE, IDAHO

FALLS, ID, 83415. 6. SERVICE MUST BE DEDICATED, NON-ROUTED, 10 GBPS E-PLS

PLACED OVER TELCO OPTICAL TRANSMISSION NETWORK. 7. THERE ARE

MULTIPLE TELCO CARRIERS LOCATED IN THE EQUINIX DA6 N. STEMMONS FWY,

DALLAS, TX AND ALL HAVE INTERCONNECT CAPABILITY WITH THE DHS CAGE

40560 IN DA6 VIA DHS CONTRACT WITH EQUINIX. THAT INTERCONNECT FROM

THE WINNING TELCO CAGE TO THE DHS CAGE 40560 IN THE EQUINIX DA6

FACILITY WILL BE COORDINATED BY DHS/RAYTHEON WITH EQUINIX UNDER

THE EXISTING DHS/RAYTHEON CONTRACT WITH EQUINIX. 8. WINNING TELCO

MUST PROVIDE DHS/MR. BERNARD J. YOCUM JR. AND MR. CURLEE WINGATE

WITH INTERSERVICE SUPPORT AGREEMENT (ISA) IDENTIFYING DHS AS

AUTHORIZED USER OF TELCO SERVICE; PROVIDING TELCO CIRCUIT IDENTIFIER,

AND IDENTIFY PORTS ON TELCOMFIBER TERMINATING PANEL (FTP) IN TELCO'S

EQUINIX CAGE WITH CAGE AND BUILDING NUMBER/ADDRESS TO BE USED BY

DHS TO ARRANGE WITH EQUINIX FOR INSIDE WIRE INSTALLATION AND

MAINTENANCE FROM THE TELCO BUILDING AND CAGE TO THE DHS BUILDING

(DA6) AND CAGE 40560 UNDER THE DHS/RAYTHEON CONTRACT WITH EQUINIX. 9.

TELCO INTERFACE AT EQUINIX DALLAS FACILITY WILL BE SINGLE MODE FIBER,

9.5/125 MICRON, WITH OPTICS WORKING AT 1310NM. 10.VENDOR MUST PROVIDE

LIGHT LEVEL READINGS (DB LOSS) AT THE DEMARC LOCATIONS PRIOR TO

CIRCUIT TURN UP TO THE GOV'T INSURING THE LIGHT LEVELS ARE WITHIN

SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -5 TO -13. 11.DHS POC'S FOR

EQUINIX DA6 DHS CAGE ARE: A. MR. ERIC HAMID OFFICE PHONE: 305-961-3730

CELL PHONE: 786-423-5359 E-MAIL: EHAMID@EQUINIX.COM B. MR. ANDREW ZASO

OFFICE PHONE: 703-434-2907 CELL PHONE: 202-893-0667 E-MAIL:

ANDY.ZASO@ASSOCIATES.CISA.DHS.GOV C. MR. CHRISTOPHER GEISLER CELL

PHONE: 703-965-0832 E-MAIL:CHRISTOPHER.GEISLER@ASSOCIATES.CISA.DHS.GOV

D. MR. RICHARD HERNANDEZ CELL PHONE: 301-524-6149 E-MAIL:

RICHARD.HERNANDEZ@ASSOCIATES.CISA.DHS.GOV E. MR. BERNARD J. YOCUM

JR. OFFICE PHONE: 703-387-6060 CELL PHONE: 703-395-3718 E-MAIL:

BERNARD.YOCUM@ASSOCIATES.CISA.DHS.GOV 12.TELCO HAS TWO DEMARC

LOCATIONS FOR IDAHO NATIONAL LABS, START A DEDICATED SERVICE AT 10

GBPS ETHERNET - PRIVATE LINE SERVICE (E-PLS) USING TELCO OPTICAL

TRANSMISSION NETWORK FROM DHS ROUTER LOCATED IN DHS CAGE 40560 AT

EQUINIX DATA CENTER (DA6) 1950 N. STEMMONS FWY, DALLAS, TX 75207 TO

IDAHO NATIONAL LABS, BLDG ENGINEERING RESEARCH OFFICE BLDG (EROB),

2525 FREMONT AVENUE, IDAHO FALLS, ID, 83415. THE PREFERRED LOCATION IS

THE EROB BLDG, 2525 FREMONT AVE, RM 149, IDAHO FALLS, ID, 83415. IF NO LEC

CAPACITY AVAILABLE AT EROB, THEN TELCO CAN USE BLDG UNIVERSITY BLDG

FOUR (UB4), RM 115, 525 MK SIMPSON BLVD; IDAHO FALLS, ID, 83401. WINNING

TELCO MUST DELIVER SERVICE TO EROB, RM 149 IF AT ALL POSSIBLE. THERE

ARE TWO LECS PRESENT AT BOTH EROB, RM 149 OR UB4, RM 116 PROVIDING LEC

SERVICES. THEY ARE LUMEN-QWEST, AND SYRINGA NETWORKS. EITHER CAN BE

USED. 13.TELCO INTERFACE AT IDAHO NATIONAL LABS, BLDG EROB, S.

REMARKS CONTINUED: 2525 FREMONT AVE, IDAHO FALS, ID WILL BE SINGLE

MODE FIBER, 9.5/125 MICRON, WITH OPTICS WORKING AT 1310NM. 14.VENDOR

MUST PROVIDE LIGHT LEVEL READINGS (DB LOSS) AT THE DEMARC LOCATIONS

PRIOR TO CIRCUIT TURN UP TO THE GOV'T INSURING THE LIGHT LEVELS ARE

WITHIN SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -5 TO -13. 15.DHS POC'S FOR

IDAHO NATIONAL LABS, EROB, 2525 FREMONT AVENUE, IDAHO FALLS, ID, 83415

ARE: A. MR. KEVIN HEMSLEY OFFICE PHONE: 208-526-0507 CELL PHONE: 208-317-

3644 E-MAIL: KEVIN.HEMSLEY@INL.GOV B. MR. CAVRON MORTENSEN OFFICE

PHONE: 208-526-3291 CELL PHONE: 208-557-9593 E-MAIL:

CAVRON.MORTENSEN@INL.GOV 16.CIRCUIT MUST BE TAGGED WITH LOCAL

EXCHANGE CARRIER (LEC) CIRCUIT ID AND LONG HAUL CARRIER ID AT BOTH

SERVICE LOCATIONS. 17.CIRCUIT REQUIRES THE FOLLOWING TECHNICAL

PARAMETERS: A. DATA RATE: 10.0 GBPS PLUS OR MINUS 20 PPM B. FORMAT:

ETHERNET 802.3AW C. FRAMING: ETHERNET 802.3AW D. ELECTRICAL INTERFACE:

OPTICAL, SINGLE MODE, 1310 NM E. IEEE STANDARD: 802.3AW COMPLIANT F.

LINE MUST REMAIN OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY,

SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER. G. REQUEST ONE-HOUR

RESPONSE TIME TURN-AROUND TO REPAIR ONCE TROUBLE CALL HAS BEEN

REPORTED. H. GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE

ENGINEERED INTO THE CIRCUIT. I. SINGLE MODE FIBER TERMINATIONS: SC OR

LC J. NO NETWORK INTERFACE UNIT (NIU). K. DEDICATED PATH L. VENDOR

MUST HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES. M.

VENDOR MUST TEST CIRCUIT END-TO-END FOR 24 HOURS IAW EITHER ITU-T

Y.1564 OR RFC-6815 AND A SERVICE AVAILABILITY OF 99.5% OR BETTER. N.

VENDOR MUST HAVE A 24X7 NETWORK OPS CENTER. O. COMMERCIAL CIRCUIT

WILL BE ACCEPTED BY THE GOV'T BY THE DHS NC PS NETWORK OPERATIONS

CENTER, CORRY STATION, PENSACOLA, FL, COM'L 1-866-645-4357, E-MAIL DL-

NOC_NETWORK@US-CERT.GOV

TESTING PARAMETERS AND THRESHOLDS:

THE FOLLOWING TESTING PARAMETERS SHALL BE MEASURED DURING TEST

AND ACCEPTANCE TESTING 1. SEVERELY ERRORED SECONDS (SES): SHALL BE

LESS THAN 0.2 PERCENT 2. DEGRADED MINUTES (DM); SHALL BE LESS THAN 0.2

PERCENT 3. ERROR FREE SECONDS (EFS): SHALL BE GREATER THAN 99.5

PERCENT 4. LOSS OF BIT COUNT INTEGRITY (LBCI): LOSS OF BIT COUNT

INTEGRITY SHALL BE MONITORED USING TEST EQUIPMENT WHICH CAN DETECT

AND MEASURE THE OCCURENCE OF THE INSERTION OR DELETION OF ONE OR

MORE BITS INTO THE DIGITAL BIT STREAM, OFTEN DEFINED AS PATTERN SLIP. 5.

MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER

THAN 24 HOURS. 6. ROUND TRIP DELAY (RTD) RTD SHALL BE MEASURED OVER

THE 10 GBPS CIRCUIT AND SHALL BE LESS THAN OR EQUAL TO 35

MILLISECONDS. 19.REQUEST TELCO VENDOR PROVIDE ALL LONG HAUL & LEC

CIRCUIT IDENT IFIERS TO DELIVER THE CIRCUIT TO THESE TWO END LOCATIONS

TO MR BE RNARD J. YOCUM JR, EMAIL

BERNARD.YOCUM@ASSOCIATES.CISA.DHS.GOV, P RIOR TO INSTALLTION OF THE

CIRCUIT ALONG WITH ANY ENGINEERING REC ORDS FOR THIS CIRCUIT. 20.THIS

WILL BE A TELECOMMUNICATION SERVICE PRIORITY (TSP) CIRCUIT WITH A

RESTORAL PRIORITY OF 2. TSP ASSIGNED IS TSP0LHDUG-02. FOR DHS DALLAS-

EQUINIX/MR. HAMID, MR. ZASO, MR. GEISLER, MR. HERNANDEZ, & MR. YOCUM: 1.

THIS WILL BE A NEW 10 GBPS E-PLS POINT-TO-POINT (PT-TO-PT) CIRCUIT THAT

WILL BE DELIVERED BY THE WINNING TELCO VENDOR TO THE NEW DHS

EQUIPMENT INSTALLED IN THE DHS CAGE 40560 AT THE EQUINIX DA6 BLDG, 1950

N. STEMMONS FWY, DALLAS, TX 75207. 2. AS SOON AS WE RECEIVE THE

INFORMATION ON THE VENDOR'S CIRCUIT NUMBERS, EQUINIX BLDG FOR THE

TELCO, AND THE PORTS ON THEIR CAGE FIBER TERMINATING PANEL (FTP) TO

USE FOR CONNECTING TO THE TELCO CAGE FOR THIS CIRCUIT, WE WILL PASS

THEM TO YOU. 3. REQUEST YOU PLACE ORDER THROUGH DHS/RAYTHEON

EQUINIX CONTRACT TO HAVE EQUINIX INSTALL SINGLE MODE FIBER JUMPERS

FROM TELCO DEMARC IN BUILDING, U. REMARKS CONTINUED: CAGE, AND

PORTS SPECIFIED BY TELCO TO THE DHS CAGE 40560 IN BLDG DA6 ON FIBER

TERM PANEL (FTP) PORTS TO BE SPECIFIED BY YOU. 4. REQUEST YOU INSTALL

SINGLE MODE FIBER JUMPERS FROM DHS FIBER TERM PANEL (FTP) IN THE DHS

CAGE 40560 AT EQUINIX DA6 ON THE FTP PORTS IDENTIFIED BY YOU FOR THIS

CIRCUIT TO THE DHS ASR1002-HX ROUTER IN THE DHS CAGE 40560 FOR THIS

CIRCUIT. 5. PORT ASSIGNMENT ON ROUTER WILL BE PROVIDED BY OUR DHS

MOE ENGINEERING TEAM STAFF TO YOU. 6. REQUEST YOU ADVISE ALL

ADDRESSEES ON THIS ORDER AS TO WHEN THE TELCO CIRCUIT IS DELIVERED TO

THE EQUINIX FACILITY HOUSING THE TELCO CAGE AND WHEN IN-HOUSE FIBER

CONNECTIONS ARE COMPLETED BETWEEN THE TELCO DEMARC CAGE IN THE

EQUINIX BUILDING TO THE DHS CAGE FTP IN EQUINIX BUILDING DA6 AS WELL

AS THE GOV'T FIBER JUMPERS TO THE DHS MOE ASR1002-HS ROUTER IN THE DHS

CAGE. FOR DOE INL/MR. HEMSLEY, AND MR. MORTENSEN: 1. THIS WILL BE A

NEW 10 GBPS E-PLS POINT-TO-POINT (PT-TO-PT) CIRCUIT THAT WILL BE

DELIVERED BY THE WINNING TELCO VENDOR TO IDAHO NATIONAL LABS,

ENGINEERING RESEARCH OFFICE BLDG (EROB), 2525 FREMONT AVE, RM 149 OR

UNIVERSITY BLVD FOUR (UB4), RM 116. WE MUST AWAIT WORD FROM THE

WINNING VENDOR ON WHERE AND WHO THEY WILL HAVE DELIVER THE

CIRCUIT & WITH WHICH LEC. AS SOON AS WE RECEIVE THE INFORMATION ON

WHICH LEC LOCATION THAT THE VENDOR WILL USE ALONG WITH THEIR

CIRCUIT NUMBER, WE WILL PASS THIS TO YOU. 2. AS SOON AS WE RECEIVE THE

INFORMATION ON THE VENDOR'S CIRCUIT NUMBERS WE WILL PASS THEM TO

YOU. 3. REQUEST YOU INSTALL SINGLE MODE FIBER JUMPERS FROM TELCO

FIBER TERM PANEL (FTP) IN EROB ROOM 149, OR UB4, RM 116 TO THE DHS

ASR1002-HX ROUTER IN EROB, RM 106, FOR THIS CIRCUIT. 4. PORT ASSIGNMENT

ON ROUTER WILL BE PROVIDED BY OUR DHS MOE ENGINEERING TEAM STAFF TO

YOU. 5. REQUEST YOU ADVISE ALL ADDRESSEES ON THIS ORDER AS TO WHEN

THE TELCO CIRCUIT IS DELIVERED TO THE DHS FACILITY AND WHEN IN-HOUSE

GOV'T FIBER V. CONNECTIONS ARE COMPLETED BETWEEN THE TELCO DEMARC

TO THE DHS MOE ASR1002-HX ROUTER IN ROOM 106. (** DEMARC CONT'D **) (SP

A) (PMRY DEMARC POC) MR. ERIC HAMID; (U NCLASS USER)

EHAMID@EQUINIX.COM; (CMCL) 1-305-961-3730; (OFFHRS) 1-786-423-5359 (ALTN

DEMARC POC) MR. ANDREW M ZASO; (UNCLASS USER) ANDY.ZASO@ASS

OCIATES.CISA.DHS.GOV; (CMCL) 1-703-434-2907; (PAGER) 1-202-860-88 42; (OFFHRS)

1-202-893-0667 (SP B) (PMRY DEMARC POC) MR. ERIC HAMID; (UNCLASS USER)

EHAMID@EQ UINIX.COM; (CMCL) 1-305-961-3730; (OFFHRS) 1-786-423-5359 (ALTN

DEMARC POC) MR. ANDREW M ZASO; (UNCLASS USER) ANDY.ZASO@ASS

OCIATES.CISA.DHS.GOV; (CMCL) 1-703-434-2907; (PAGER) 1-202-860-88 42; (OFFHRS)

1-202-893-0667 (SP C) (PMRY DEMARC POC) MR. KEVIN HEMSLEY; (CLASS USER)

HEMSKE@I DAHO.DOE.SGOV.GOV; (UNCLASS USER) KEVIN.HEMSLEY@INL.GOV;

(CMCL) 1 -208-526-0507; (OFFHRS) 1-208-317-3644 (ALTN DEMARC POC) MR.

CAVRON MORTENSEN; (UNCLASS USER) CAVRON.MOR TENSEN@INL.GOV;

(CMCL) 1-208-526-3291; (OFFHRS) 1-208-557-9593 (SP D) (PMRY DEMARC POC) MR.

KEVIN HEMSLEY; (CLASS USER) HEMSKE@I DAHO.DOE.SGOV.GOV; (UNCLASS

USER) KEVIN.HEMSLEY@INL.GOV; (CMCL) 1 -208-526-0507; (OFFHRS) 1-208-317-3644

(ALTN DEMARC POC) MR. CAVRON MORTENSEN; (UNCLASS USER) CAVRON.MOR

TENSEN@INL.GOV; (CMCL) 1-208-526-3291; (OFFHRS) 1-208-557-9593 W.

JUSTIFICATION OF SERVICE REQUESTED: SERVICE IS URGENTLY NEEDED TO

SUPPORT NEW SERVICE BETWEEN THESE LOCATIONS IN ORDER TO ACCESS

CLOUD FACILITIES AND PROVIDE DIVERSITY FOR SERVICES. X. DD FORM 1368:

DD FORM 1368'S (MODIFIED USE OF LEASED COMMUNICATION FACILITIES), OR

EMAIL EQUIVALENT, WILL BE SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW

THE PROCUREMENT GUIDE FOR TELECOMMUNICATIONS BY THE STATION

DESIGNATED IN PARAGRAPH 2H AS CCO/CMO. GUIDANCE ON SUBMISSION IS

AVAILABLE AT HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP.

CIRCUIT SPECIFICATIONS: CONUS NO JUMBO FRAME ETHERNET VENDOR WILL

PERFORM ACCEPTANCE TESTING IN ACCORDANCE WITH EITHER RFC-6815 OR

ITU-T Y.1564. VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW ITU-T.Y.1564

SPECIFICALLY, FRAME SIZES OF 64,128,256,512,1024,1280 AND 1518 BYTES MUST BE

USED. THE TEST MUST VERIFY LENGTH OF RECEIVED FRAMES, INDICATE

NUMBER OF FRAMES DROPPED, NUMBER OF FRAMES RECEIVED OUT OF ORDER,

AND DUPLICATE FRAMES. TESTS MUST BE BI-DIRECTIONAL USING THE SAME

DATA RATE IN EACH DIRECTION. BURST TESTS MUST BE RUN TO DETERMINE

MINIMUM INTERVAL BETWEEN FRAMES THAT CAN BE PROCESSED WITHOUT

FRAME LOSS. A THROUGHPUT TEST IS REQUIRED INDICATING THE FASTEST

RATE AT WHICH TEST FRAMES CAN BE TRANSMITTED WITHOUT FRAME LOSS. A

SEPARATE THROUGHPUT TEST MUST BE RUN WITH FRAMES ADDRESSED TO THE

HARDWARE BROADCAST ADDRESS CONSTITUTING AT LEAST 1% OF THE TEST

STREAM AND BE EVENLY DISTRIBUTED THROUGHOUT THE TEST. Z. CIRCUIT

SPECIFICATIONS CONTINUED: A LATENCY TEST MUST BE RUN FOR A PERIOD OF

NO LESS THAN 120 SECONDS, AND REPEATED NO LESS THAT 20 TIMES. THE TEST

STREAM FOR THE LATENCY TEST SHOULD BE RUN AT THE THROUGHPUT RATE

FOR CORRESPONDING FRAME SIZES FROM THE THROUGHPUT TEST. END TO END

LATENCY WILL BE CALCULATED AS THE AVERAGE OVER THE 20 TEST RUNS.

FRAME LOSS RATE TESTS SHOULD BE RUN AT THE FRAME RATE

CORRESPONDING TO THE MAXIMUM FRAME RATE, AND REDUCED BY 10%

INTERVALS UNTIL THERE ARE AT LEAST TWO CONSECUTIVE RUNS IN WHICH NO

FRAMES ARE LOST.THROUGHPUT TEST RESULTS: PASSING RATE 100% FOR ALL

FRAME BYTE SIZES EXERCISED. FRAME LOSS RATE (%) RESULTS: FRAME LOSS

RATE LESS THAN 0.01% FOR ALL FRAME BYTE SIZES EXERCISED. LATENCY WILL

BE MEASURED WILL BE ACCORDING TO THE FOLLOWING MAXIMUM

TRANSMISSION DELAY FOR ANY CIRCUIT UP TO 500 MILES AIR-MILES IN LENGTH

SHALL BE NO GREATER THAN 13MS ONE-WAY AND ANY POINT-TO-POINT

CIRCUIT LONGER THAN 500 AIR-MILES SHALL BE NO GREATER THAN 50MS ONE

WAY WITHIN THE 48 CONTINENTAL STATES. ANY APS SWITCHOVER SHALL TAKE

LESS THAN 50 MILLISECONDS MONTHLY AVAILABILITY SHALL BE NO LESS

THAN 99.5%.