ATTACHMENT 1 FOR SOLICITATION HC101322QA345
***ATTENTION MALMSTROM AFB, MT LOCATION***
THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY
DIVERSE END TO END TO THE GOVERNMENT'S SERVICE DELIVERY POINTS
(SDP'S) FROM TSR SG08APR227331; MEANING THAT THE PHYSICAL PATHS ARE
TOTALLY SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE
LOCATIONS), AND FIBER BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50
METERS PHYSICAL SEPARATION FROM TSR SG08APR227331.
***THE 50 METER SEPARATION IS WAIVED INSIDE BLDG 1082 FOR MALMSTROM
AFB, MT LOCATION.*** 7. THE TELECOM PROVIDER MUST PROVIDE DITCO
COLOR POWERPOINT DRAWINGS FOR TECHNICAL REVIEW SHOWING THE ROUTE
FROM THE N. REMARKS CONTINUED: COMMERCIAL DEMARCS TO THE
SUPPORTING CENTRAL OFFICES AND/OR WIRING CENTERS. DRAWINGS MUST
INCLUDE TOTAL FIBER MILES AND ROUND TRIP DELAY (RTD). ADDITIONALLY,
THE VENDOR IS TO PROVIDE DITCO WITH DETAILED CIRCUIT/PATH
CONNECTIVITY DIAGRAMS, IN KMZ OR KML FORMAT, IDENTIFYING ALL POINTS
OF PRESENCE (POP) FO R PROPOSAL EVALUATION AND AS A FINAL RECORD OF
THE INSTALLED PATH . THESE DIAGRAMS MUST BE PROVIDED TO DISA HQ IE16
(DISA.MEADE.IE .MBX.IE16-PROVISIONING-TEAM@MAIL.MIL) FOR HISTORICAL
PURPOSES. 8. SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES. 9.
SINGLE MODE FIBER MUST BE ENGINEERED/PROVISIONED IN SUCH A WAY THAT
THE GOVERNMENT CAN CHANGE/REVISE CHANNELIZATION WITHOUT TELECOM
PROVIDER INTERVENTION.
NOTE 1 (JITTER): IN A STEADY-STATE CONDITION, THE PATTERN OF
SYNCHRONOUS TRANSPORT SIGNAL (STS) POINTER ADJUSTMENTS, SDN TO SDN
(END-TO-END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL
BE NO MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH THE
DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSI T1.105.03-1994) THAN THE
POINTER ADJUSTMENT SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994. DURING
TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2 TIMES PER DAY),
THE PATTERN OF STS POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END
THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR OR
LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME INTERVAL ERROR (MTIE)
OVER A PERIOD OF S SECONDS, OR WANDER, SHALL NOT EXCEED (.01S + 10000)
NANOSECONDS FOR VALUES OF S GREATER THAN 10,000. B. WAVELENGTH
TRANSMISSION SERVICES: WAVELENGTH TRANSMISSION SERVICES FOR RATES
OF 2.5GBPS SHALL BE IN ACCORDANCE WITH ITU-T RECOMMENDATIONS
G.709(03/2003), G.707(12/03), G.957(03/06), G.692(10/98) & TELCORDIA GR253-IE4. THE
PROVIDED WAVELENGTH TRANSMISSION SERVICE SHALL NOT INHIBIT
GOVERNMENT OPERATION OF UNDERLYING PROTOCOLS AND TRANSPORT
SYSTEMS SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP, O. REMARKS
CONTINUED: ATM, GIGABIT ETHERNET, AND ENCRYPTION. THE WAVELENGTH
TRANSMISSION SERVICE PROVIDED SHALL PASS ALL PAYLOAD, PATH AND LINE
OVERHEAD BYTES TRANSPARENTLY (UNTOUCHED/UNALTERED) AND WITHOUT
MONITORING SDP TO SDP. THERE SHALL NOT BE ANY LINE TERMINATING
EQUIPMENT (LTE) BETWEEN SDP AND SDP. C. SINGLE MODE FIBER MUST BE
TERMINATED TO THE LINE SIDE OF THE FIBER TERMINATING PATCH PANEL
INSTALLED AT BOTH DISA IE1 PROVIDED SERVICE DELIVERY NODE LOCATIONS.
D. THE TELECOM PROVIDER MUST CONTACT DISA GOC TIER-II ENGINEERING
UPON RECEIPT OF A VALID TSO TO ESTABLISH THE COORDINATION AND
ACTIVATION PROCESS. PRI POC: DISA GLOBAL CASA INFRASTRUCTURE
INTEGRATION LEASE BB TEAM PHONE: (C) 618-418-9813, (D) 418-9813 EMAIL:
DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-LEAS E-BB-
T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER (CASA RF CIRCUIT
ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:
DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL 10. ONCE
TELECOM PROVIDER HAS COMPLETED INSIDE WIRING FROM THEIR FIBER
DISTRIBUTION PANEL INSTALLED IN THEIR DWDM EQUIPMENT SUITE TO THE
GOVERNMENT SERVICE DELIVERY POINT (SDP) AT EACH LOCATION, THEY MUST
ENSURE THE LIGHT LEVEL READINGS (DB LOSS) ARE ADJUSTED TO READ -3 TO -9
LOSS. ADDITIONALLY, THESE LEVELS MUST BE DOCUMENTED ON THE NOTICE
OF COMPLETION (NOC) SENT TO DITCO. ***THE VENDOR MUST TERMINATE
SINGLE MODE FIBER AT BOTH LOCATIONS IAW UNIQUE INSTALLATION
FACTORS.*** 11. THE SINGLE MODE FIBER MUST PASS A DOCUMENTED
SATISFACTORY 72 HOUR END TO END TEST IAW ITU STANDARD M.2101 PRIOR TO
TURN-UP TO THE GOVERNMENT.
1. VENDOR MUST MEET SVC DATE. 2. CIRCUIT REQUIRES THE FOLLOWING
PARAMETERS: (A) FIBER TERMINATION: SINGLE-MODE INTERFACE
REQUIREMENT/INTERFACE DATA RATE: LINE CODING, FRAME FORMAT,
PHYSICAL CONNECTOR, 2.5 GBPS, NRZ, SCRAMBLED PER ANSI T1.104-1991 (R2003).
ALL OPTIONS DEFINED SC CONNECTOR, P. REMARKS CONTINUED: SINGLE-MODE
FIBER PER ANSI T1.105.06-2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3). (B) LINE
MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A
DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER. (C) ONE-HOUR
RESPONSE TIME TURN-AROUND MUST OCCUR TO REPAIR ONCE TROUBLE-CALL
HAS BEEN REPORTED. (D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT
TO BE ENGINEERED INTO CIRCUIT. (E) SINGLE MODE FIBER TERMINATIONS "SC"
CONNECTORS. (F) NO NETWORK INTERFACE UNIT. (G) DEDICATED PATH. (H)
CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT
OUTAGES. (I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY END TO
END TEST ON THE 2.5GB WAVE SERVICE IAW ITU STANDARD M.2101.
ADDITIONALLY, THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT
THE TEST RESULTS AND THOSE RESULTS MUST BE EMAILED TO THE ACCEPTING
AUTHORITY FOR REVIEW. (J) VENDOR MUST HAVE A 24X7 NETWORK
OPERATIONAL CENTER. (K) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON
BEHALF OF THE GOVERNMENT BY THE DGOC: PRI POC: DISA GLOBAL CASA
INFRASTRUCTURE INTEGRATION LEASE BB TEAM PHONE: (C) 618-418-9813, (D)
418-9813 EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-
INTEGRATION-LEAS E-BB-T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER
(CASA RF CIRCUIT ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:
DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL (L) THE
VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NUMBER AND THE 1-800
TROUBLE REPORT NUMBER TO THE ACCEPTING AUTHORITY PRIOR TO THE
GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE COMPLETED AND
TESTED PROPERLY IAW THE ORDER PRIOR TO TURN-UP TO THE GOVERNMENT. 3.
VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE
MODE FIBER IAW UNIQUE INSTALLATION FACTORS. 4. INSIDE WIRING IS
AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS. 5. VENDOR MUST
COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO
REQUIRING ACCESS TO FACILITIES AT BOTH USER Q. REMARKS CONTINUED:
LOCATIONS. 6. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT
AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR
EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT CENTER (DCCC)
SCOTT AFB, IL. TOLL FREE: 1-855-868-9500, COML: 618-418-9500, DSN: 312-418-9500.
7. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-
1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS AVAILABLE AT
<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK ON "DISA-DITCO
CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS: LINE RATE: 2.5GB. LINE CODE: NRZ. FRAME
FORMAT: SCRAMBLED IAW ANSI T1.104-1991 (R2003). 1. TEST AND ACCEPTANCE:
FIBER OPTIC 2.5GB WAVE CIRCUITS SHALL PASS A FULLY DOCUMENTED
SATISFACTORY SOAK TEST BY THE GOC AT SCOTT AFB, IL. PRIMARY: (C) 618-418-
8691, (D) 418-8691. 2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED
SHALL MEET THE FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY
BASIS. PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION: NON-
DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO 99.5%
OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC): LESS THAN
OR EQUAL TO 9%. ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005%.
SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO 0.00035.
BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO 5X 10-6.
BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR EQUAL TO
1 PER 72 HOURS. JITTER: SEE NOTE 1 (JITTER). BER: LESS THAN OR EQUAL TO
1X10-12. DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D MSEC) * WHERE
"D" IS THE SDP TO SDP TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT
CIRCLE, IN KILOMETERS. 3. ROUND TRIP DELAY (RTD) FOR THIS DISA
TRANSPORT TRUNK WILL BE MEASURED IN MILLISECONDS FROM THE
CUSTOMER'S SERVICE R. REMARKS CONTINUED: DELIVERY POINT (SDP) SITE-A
TO THE CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE
LESS THAN OR EQUAL TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE
GOVERNMENT'S MISSION. THE GOVERNMENT ACCEPTING AUTHORITY WILL
CONFIRM THE RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT
ALIGN WITH THE CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO
IMMEDIATELY IN WRITING.