ATTACHMENT 1 FOR SOLICITATION HC101322QA345

***ATTENTION MALMSTROM AFB, MT LOCATION***

THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY

DIVERSE END TO END TO THE GOVERNMENT'S SERVICE DELIVERY POINTS

(SDP'S) FROM TSR SG08APR227331; MEANING THAT THE PHYSICAL PATHS ARE

TOTALLY SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE

LOCATIONS), AND FIBER BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50

METERS PHYSICAL SEPARATION FROM TSR SG08APR227331.

***THE 50 METER SEPARATION IS WAIVED INSIDE BLDG 1082 FOR MALMSTROM

AFB, MT LOCATION.*** 7. THE TELECOM PROVIDER MUST PROVIDE DITCO

COLOR POWERPOINT DRAWINGS FOR TECHNICAL REVIEW SHOWING THE ROUTE

FROM THE N. REMARKS CONTINUED: COMMERCIAL DEMARCS TO THE

SUPPORTING CENTRAL OFFICES AND/OR WIRING CENTERS. DRAWINGS MUST

INCLUDE TOTAL FIBER MILES AND ROUND TRIP DELAY (RTD). ADDITIONALLY,

THE VENDOR IS TO PROVIDE DITCO WITH DETAILED CIRCUIT/PATH

CONNECTIVITY DIAGRAMS, IN KMZ OR KML FORMAT, IDENTIFYING ALL POINTS

OF PRESENCE (POP) FO R PROPOSAL EVALUATION AND AS A FINAL RECORD OF

THE INSTALLED PATH . THESE DIAGRAMS MUST BE PROVIDED TO DISA HQ IE16

(DISA.MEADE.IE .MBX.IE16-PROVISIONING-TEAM@MAIL.MIL) FOR HISTORICAL

PURPOSES. 8. SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES. 9.

SINGLE MODE FIBER MUST BE ENGINEERED/PROVISIONED IN SUCH A WAY THAT

THE GOVERNMENT CAN CHANGE/REVISE CHANNELIZATION WITHOUT TELECOM

PROVIDER INTERVENTION.

NOTE 1 (JITTER): IN A STEADY-STATE CONDITION, THE PATTERN OF

SYNCHRONOUS TRANSPORT SIGNAL (STS) POINTER ADJUSTMENTS, SDN TO SDN

(END-TO-END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL

BE NO MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH THE

DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSI T1.105.03-1994) THAN THE

POINTER ADJUSTMENT SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994. DURING

TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2 TIMES PER DAY),

THE PATTERN OF STS POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END

THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR OR

LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME INTERVAL ERROR (MTIE)

OVER A PERIOD OF S SECONDS, OR WANDER, SHALL NOT EXCEED (.01S + 10000)

NANOSECONDS FOR VALUES OF S GREATER THAN 10,000. B. WAVELENGTH

TRANSMISSION SERVICES: WAVELENGTH TRANSMISSION SERVICES FOR RATES

OF 2.5GBPS SHALL BE IN ACCORDANCE WITH ITU-T RECOMMENDATIONS

G.709(03/2003), G.707(12/03), G.957(03/06), G.692(10/98) & TELCORDIA GR253-IE4. THE

PROVIDED WAVELENGTH TRANSMISSION SERVICE SHALL NOT INHIBIT

GOVERNMENT OPERATION OF UNDERLYING PROTOCOLS AND TRANSPORT

SYSTEMS SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP, O. REMARKS

CONTINUED: ATM, GIGABIT ETHERNET, AND ENCRYPTION. THE WAVELENGTH

TRANSMISSION SERVICE PROVIDED SHALL PASS ALL PAYLOAD, PATH AND LINE

OVERHEAD BYTES TRANSPARENTLY (UNTOUCHED/UNALTERED) AND WITHOUT

MONITORING SDP TO SDP. THERE SHALL NOT BE ANY LINE TERMINATING

EQUIPMENT (LTE) BETWEEN SDP AND SDP. C. SINGLE MODE FIBER MUST BE

TERMINATED TO THE LINE SIDE OF THE FIBER TERMINATING PATCH PANEL

INSTALLED AT BOTH DISA IE1 PROVIDED SERVICE DELIVERY NODE LOCATIONS.

D. THE TELECOM PROVIDER MUST CONTACT DISA GOC TIER-II ENGINEERING

UPON RECEIPT OF A VALID TSO TO ESTABLISH THE COORDINATION AND

ACTIVATION PROCESS. PRI POC: DISA GLOBAL CASA INFRASTRUCTURE

INTEGRATION LEASE BB TEAM PHONE: (C) 618-418-9813, (D) 418-9813 EMAIL:

DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-LEAS E-BB-

T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER (CASA RF CIRCUIT

ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:

DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL 10. ONCE

TELECOM PROVIDER HAS COMPLETED INSIDE WIRING FROM THEIR FIBER

DISTRIBUTION PANEL INSTALLED IN THEIR DWDM EQUIPMENT SUITE TO THE

GOVERNMENT SERVICE DELIVERY POINT (SDP) AT EACH LOCATION, THEY MUST

ENSURE THE LIGHT LEVEL READINGS (DB LOSS) ARE ADJUSTED TO READ -3 TO -9

LOSS. ADDITIONALLY, THESE LEVELS MUST BE DOCUMENTED ON THE NOTICE

OF COMPLETION (NOC) SENT TO DITCO. ***THE VENDOR MUST TERMINATE

SINGLE MODE FIBER AT BOTH LOCATIONS IAW UNIQUE INSTALLATION

FACTORS.*** 11. THE SINGLE MODE FIBER MUST PASS A DOCUMENTED

SATISFACTORY 72 HOUR END TO END TEST IAW ITU STANDARD M.2101 PRIOR TO

TURN-UP TO THE GOVERNMENT.

1. VENDOR MUST MEET SVC DATE. 2. CIRCUIT REQUIRES THE FOLLOWING

PARAMETERS: (A) FIBER TERMINATION: SINGLE-MODE INTERFACE

REQUIREMENT/INTERFACE DATA RATE: LINE CODING, FRAME FORMAT,

PHYSICAL CONNECTOR, 2.5 GBPS, NRZ, SCRAMBLED PER ANSI T1.104-1991 (R2003).

ALL OPTIONS DEFINED SC CONNECTOR, P. REMARKS CONTINUED: SINGLE-MODE

FIBER PER ANSI T1.105.06-2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3). (B) LINE

MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A

DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER. (C) ONE-HOUR

RESPONSE TIME TURN-AROUND MUST OCCUR TO REPAIR ONCE TROUBLE-CALL

HAS BEEN REPORTED. (D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT

TO BE ENGINEERED INTO CIRCUIT. (E) SINGLE MODE FIBER TERMINATIONS "SC"

CONNECTORS. (F) NO NETWORK INTERFACE UNIT. (G) DEDICATED PATH. (H)

CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT

OUTAGES. (I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY END TO

END TEST ON THE 2.5GB WAVE SERVICE IAW ITU STANDARD M.2101.

ADDITIONALLY, THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT

THE TEST RESULTS AND THOSE RESULTS MUST BE EMAILED TO THE ACCEPTING

AUTHORITY FOR REVIEW. (J) VENDOR MUST HAVE A 24X7 NETWORK

OPERATIONAL CENTER. (K) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON

BEHALF OF THE GOVERNMENT BY THE DGOC: PRI POC: DISA GLOBAL CASA

INFRASTRUCTURE INTEGRATION LEASE BB TEAM PHONE: (C) 618-418-9813, (D)

418-9813 EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-

INTEGRATION-LEAS E-BB-T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER

(CASA RF CIRCUIT ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:

DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL (L) THE

VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NUMBER AND THE 1-800

TROUBLE REPORT NUMBER TO THE ACCEPTING AUTHORITY PRIOR TO THE

GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE COMPLETED AND

TESTED PROPERLY IAW THE ORDER PRIOR TO TURN-UP TO THE GOVERNMENT. 3.

VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE

MODE FIBER IAW UNIQUE INSTALLATION FACTORS. 4. INSIDE WIRING IS

AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS. 5. VENDOR MUST

COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO

REQUIRING ACCESS TO FACILITIES AT BOTH USER Q. REMARKS CONTINUED:

LOCATIONS. 6. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT

AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR

EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT CENTER (DCCC)

SCOTT AFB, IL. TOLL FREE: 1-855-868-9500, COML: 618-418-9500, DSN: 312-418-9500.

7. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-

1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS AVAILABLE AT

<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK ON "DISA-DITCO

CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION

PROCEDURES."

MINIMUM TECHNICAL SPECIFICATIONS:

SPECIFIC FORMAT TO BE USED IS: LINE RATE: 2.5GB. LINE CODE: NRZ. FRAME

FORMAT: SCRAMBLED IAW ANSI T1.104-1991 (R2003). 1. TEST AND ACCEPTANCE:

FIBER OPTIC 2.5GB WAVE CIRCUITS SHALL PASS A FULLY DOCUMENTED

SATISFACTORY SOAK TEST BY THE GOC AT SCOTT AFB, IL. PRIMARY: (C) 618-418-

8691, (D) 418-8691. 2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED

SHALL MEET THE FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY

BASIS. PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION: NON-

DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO 99.5%

OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC): LESS THAN

OR EQUAL TO 9%. ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005%.

SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO 0.00035.

BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO 5X 10-6.

BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR EQUAL TO

1 PER 72 HOURS. JITTER: SEE NOTE 1 (JITTER). BER: LESS THAN OR EQUAL TO

1X10-12. DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D MSEC) * WHERE

"D" IS THE SDP TO SDP TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT

CIRCLE, IN KILOMETERS. 3. ROUND TRIP DELAY (RTD) FOR THIS DISA

TRANSPORT TRUNK WILL BE MEASURED IN MILLISECONDS FROM THE

CUSTOMER'S SERVICE R. REMARKS CONTINUED: DELIVERY POINT (SDP) SITE-A

TO THE CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE

LESS THAN OR EQUAL TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE

GOVERNMENT'S MISSION. THE GOVERNMENT ACCEPTING AUTHORITY WILL

CONFIRM THE RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT

ALIGN WITH THE CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO

IMMEDIATELY IN WRITING.