This solicitation requests quotes to provide, install, and maintain a 2.5 gigabit per second wavelength service between Malmstrom Air Force Base in Montana and Joint Base Lewis-McChord in Washington. Quotes are due by June 9, 2022 and must include itemized monthly recurring and non-recurring charges. The selected vendor must comply with commercial item terms and conditions and will be subject to performance requirements for availability, error rates, jitter, delay, and other service level agreements. The Defense Information Systems Agency is seeking this telecommunications service to support its mission activities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 1 FOR SOLICITATION HC101322QA333

***ATTENTION MALMSTROM AFB, MT LOCATION***

THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY

DIVERSE END TO END TO THE GOVERNMENT'S SERVICE DELIVERY POINTS

(SDP'S) FROM CJON: <>; MEANING THAT THE PHYSICAL PATHS ARE TOTALLY

SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE LOCATIONS),

AND FIBER BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS

PHYSICAL SEPARATION FROM TSR SG08APR227332.

***THE 50 METER TSR SG08APR227332 IS WAIVED INSIDE BLDG 1082 FOR

MALMSTROM AFB, MT<>B LOCATION.***

THE TELECOM PROVIDER MUST PROVIDE DITCO COLOR POWERPOINT

DRAWINGS FOR TECHNICAL REVIEW SHOWING THE ROUTE FROM THE N.

REMARKS CONTINUED: COMMERCIAL DEMARCS TO THE SUPPORTING CENTRAL

O FFICES AND/OR WIRING CENTERS. DRAWINGS MUST INCLUDE TOTAL FIBER

MILES AND ROUND TRIP DELAY (RTD). ADDITIONALLY, THE VENDOR IS TO

PROVIDE DITCO WITH DETAILED CIRCUIT/PATH CONNECTIVITY DIAGRAMS, IN

KMZ OR KML FORMAT, IDENTIFYING ALL POINTS OF PRESENCE (POP) FO R

PROPOSAL EVALUATION AND AS A FINAL RECORD OF THE INSTALLED PATH .

THESE DIAGRAMS MUST BE PROVIDED TO DISA HQ IE16 (DISA.MEADE.IE

.MBX.IE16-PROVISIONING-TEAM@MAIL.MIL) FOR HISTORICAL PURPOSES. 8. SITE

SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES. 9. SINGLE MODE

FIBER MUST BE ENGINEERED/PROVISIONED IN SUCH A WAY THAT THE

GOVERNMENT CAN CHANGE/REVISE CHANNELIZATION WITHOUT TELECOM

PROVIDER INTERVENTION.

A. NOTE 1 (JITTER): IN A STEADY-STATE CONDITION, THE PATTERN OF

SYNCHRONOUS TRANSPORT SIGNAL (STS) POINTER ADJUSTMENTS, SDN TO SDN

(END-TO-END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL

BE NO MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH THE

DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSI T1.105.03-1994) THAN THE

POINTER ADJUSTMENT SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994. DURING

TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2 TIMES PER DAY),

THE PATTERN OF STS POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END

THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR OR

LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME INTERVAL ERROR (MTIE)

OVER A PERIOD OF S SECONDS, OR WANDER, SHALL NOT EXCEED (.01S + 10000)

NANOSECONDS FOR VALUES OF S GREATER THAN 10,000.

B. WAVELENGTH TRANSMISSION SERVICES: WAVELENGTH TRANSMISSION

SERVICES FOR RATES OF 2.5GBPS SHALL BE IN ACCORDANCE WITH ITU-T

RECOMMENDATIONS G.709(03/2003), G.707(12/03), G.957(03/06), G.692(10/98) &

TELCORDIA GR253-IE4. THE PROVIDED WAVELENGTH TRANSMISSION SERVICE

SHALL NOT INHIBIT GOVERNMENT OPERATION OF UNDERLYING PROTOCOLS

AND TRANSPORT SYSTEMS SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP, O.

REMARKS CONTINUED: ATM, GIGABIT ETHERNET, AND ENCRYPTION. THE

WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL PASS ALL PAYLOAD,

PATH AND LINE OVERHEAD BYTES TRANSPARENTLY (UNTOUCHED/UNALTERED)

AND WITHOUT MONITORING SDP TO SDP. THERE SHALL NOT BE ANY LINE

TERMINATING EQUIPMENT (LTE) BETWEEN SDP AND SDP.

C. SINGLE MODE FIBER MUST BE TERMINATED TO THE LINE SIDE OF THE FIBER

TERMINATING PATCH PANEL INSTALLED AT BOTH DISA IE1 PROVIDED SERVICE

DELIVERY NODE LOCATIONS. D. THE TELECOM PROVIDER MUST CONTACT DISA

GOC TIER-II ENGINEERING UPON RECEIPT OF A VALID TSO TO ESTABLISH THE

COORDINATION AND ACTIVATION PROCESS. PRI POC: DISA GLOBAL CASA

INFRASTRUCTURE INTEGRATION LEASE BB TEAM PHONE: (C) 618-418-9813, (D)

418-9813 EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-

INTEGRATION-LEAS E-BB-T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER

(CASA RF CIRCUIT ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:

DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL 10. ONCE

TELECOM PROVIDER HAS COMPLETED INSIDE WIRING FROM THEIR FIBER

DISTRIBUTION PANEL INSTALLED IN THEIR DWDM EQUIPMENT SUITE TO THE

GOVERNMENT SERVICE DELIVERY POINT (SDP) AT EACH LOCATION, THEY MUST

ENSURE THE LIGHT LEVEL READINGS (DB LOSS) ARE ADJUSTED TO READ -3 TO -9

LOSS. ADDITIONALLY, THESE LEVELS MUST BE DOCUMENTED ON THE NOTICE

OF COMPLETION (NOC) SENT TO DITCO.

***THE VENDOR MUST TERMINATE SINGLE MODE FIBER AT BOTH LOCATIONS

IAW UNIQUE INSTALLATION FACTORS.*** 11. THE SINGLE MODE FIBER MUST

PASS A DOCUMENTED SATISFACTORY 72 HOUR END TO END TEST IAW ITU

STANDARD M.2101 PRIOR TO TURN-UP TO THE GOVERNMENT.

CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:

(A) FIBER TERMINATION: SINGLE-MODE INTERFACE REQUIREMENT/INTERFACE

DATA RATE: LINE CODING, FRAME FORMAT, PHYSICAL CONNECTOR, 2.5 GBPS,

NRZ, SCRAMBLED PER ANSI T1.104-1991 (R2003). ALL OPTIONS DEFINED SC

CONNECTOR, P. REMARKS CONTINUED: SINGLE-MODE FIBER PER ANSI T1.105.06-

2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3). (B) LINE MUST REMAIN FULLY

OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY, SEVEN DAYS PER

WEEK, AT LEAST 99.5% OR BETTER. (C) ONE-HOUR RESPONSE TIME TURN-

AROUND MUST OCCUR TO REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED.

(D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED

INTO CIRCUIT. (E) SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS. (F) NO

NETWORK INTERFACE UNIT. (G) DEDICATED PATH. (H) CARRIER REQUIRED TO

HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES. (I) THE VENDOR

MUST CONDUCT A 72 HOUR SATISFACTORY END TO END TEST ON THE 2.5GB

WAVE SERVICE IAW ITU STANDARD M.2101. ADDITIONALLY, THE VENDOR TEST

SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST RESULTS AND THOSE

RESULTS MUST BE EMAILED TO THE ACCEPTING AUTHORITY FOR REVIEW. (J)

VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL CENTER. (K) THE

COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT

BY THE DGOC: PRI POC: DISA GLOBAL CASA INFRASTRUCTURE INTEGRATION

LEASE BB TEAM PHONE: (C) 618-418-9813, (D) 418-9813 EMAIL:

DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-LEAS E-BB-

T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER (CASA RF CIRCUIT

ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:

DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL (L) THE

VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NUMBER AND THE 1-800

TROUBLE REPORT NUMBER TO THE ACCEPTING AUTHORITY PRIOR TO THE

GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE COMPLETED AND

TESTED PROPERLY IAW THE ORDER PRIOR TO TURN-UP TO THE GOVERNMENT. 3.

VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE

MODE FIBER IAW UNIQUE INSTALLATION FACTORS. 4. INSIDE WIRING IS

AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS. 5. VENDOR MUST

COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO

REQUIRING ACCESS TO FACILITIES AT BOTH USER Q. REMARKS CONTINUED:

LOCATIONS. 6. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT

AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR

EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT CENTER (DCCC)

SCOTT AFB, IL. TOLL FREE: 1-855-868-9500, COML: 618-418-9500, DSN: 312-418-9500.

7. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-

1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS AVAILABLE AT

<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK ON "DISA-DITCO

CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION

PROCEDURES."

MINIMUM TECHNICAL SPECIFICATIONS:

SPECIFIC FORMAT TO BE USED IS: LINE RATE: 2.5GB. LINE CODE: NRZ. FRAME

FORMAT: SCRAMBLED IAW ANSI T1.104-1991 (R2003). 1. TEST AND ACCEPTANCE:

FIBER OPTIC 2.5GB WAVE CIRCUITS SHALL PASS A FULLY DOCUMENTED

SATISFACTORY SOAK TEST BY THE GOC AT SCOTT AFB, IL. PRIMARY: (C) 618-418-

8691, (D) 418-8691. 2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED

SHALL MEET THE FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY

BASIS. PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION: NON-

DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO 99.5%

OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC): LESS THAN

OR EQUAL TO 9%. ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005%.

SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO 0.00035.

BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO 5X 10-6.

BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR EQUAL TO

1 PER 72 HOURS. JITTER: SEE NOTE 1 (JITTER). BER: LESS THAN OR EQUAL TO

1X10-12. DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D MSEC) * WHERE

"D" IS THE SDP TO SDP TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT

CIRCLE, IN KILOMETERS. 3. ROUND TRIP DELAY (RTD) FOR THIS DISA

TRANSPORT TRUNK WILL BE MEASURED IN MILLISECONDS FROM THE

CUSTOMER'S SERVICE R. REMARKS CONTINUED: DELIVERY POINT (SDP) SITE-A

TO THE CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE

LESS THAN OR EQUAL TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE

GOVERNMENT'S MISSION. THE GOVERNMENT ACCEPTING AUTHORITY WILL

CONFIRM THE RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT

ALIGN WITH THE CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO

IMMEDIATELY IN WRITING.