- ATTACHMENT 1 FOR SOLICITATION HC101322QA333.pdf
PDF 20 KB Posted
- Solicitation number
- HC101322QA333
- Issued by
-
Defense Information Systems Agency
About this file
This solicitation requests quotes to provide, install, and maintain a 2.5 gigabit per second wavelength service between Malmstrom Air Force Base in Montana and Joint Base Lewis-McChord in Washington. Quotes are due by June 9, 2022 and must include itemized monthly recurring and non-recurring charges. The selected vendor must comply with commercial item terms and conditions and will be subject to performance requirements for availability, error rates, jitter, delay, and other service level agreements. The Defense Information Systems Agency is seeking this telecommunications service to support its mission activities.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 1 FOR SOLICITATION HC101322QA333
***ATTENTION MALMSTROM AFB, MT LOCATION***
THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY
DIVERSE END TO END TO THE GOVERNMENT'S SERVICE DELIVERY POINTS
(SDP'S) FROM CJON: <>; MEANING THAT THE PHYSICAL PATHS ARE TOTALLY
SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE LOCATIONS),
AND FIBER BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS
PHYSICAL SEPARATION FROM TSR SG08APR227332.
***THE 50 METER TSR SG08APR227332 IS WAIVED INSIDE BLDG 1082 FOR
MALMSTROM AFB, MT<>B LOCATION.***
THE TELECOM PROVIDER MUST PROVIDE DITCO COLOR POWERPOINT
DRAWINGS FOR TECHNICAL REVIEW SHOWING THE ROUTE FROM THE N.
REMARKS CONTINUED: COMMERCIAL DEMARCS TO THE SUPPORTING CENTRAL
O FFICES AND/OR WIRING CENTERS. DRAWINGS MUST INCLUDE TOTAL FIBER
MILES AND ROUND TRIP DELAY (RTD). ADDITIONALLY, THE VENDOR IS TO
PROVIDE DITCO WITH DETAILED CIRCUIT/PATH CONNECTIVITY DIAGRAMS, IN
KMZ OR KML FORMAT, IDENTIFYING ALL POINTS OF PRESENCE (POP) FO R
PROPOSAL EVALUATION AND AS A FINAL RECORD OF THE INSTALLED PATH .
THESE DIAGRAMS MUST BE PROVIDED TO DISA HQ IE16 (DISA.MEADE.IE
.MBX.IE16-PROVISIONING-TEAM@MAIL.MIL) FOR HISTORICAL PURPOSES. 8. SITE
SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES. 9. SINGLE MODE
FIBER MUST BE ENGINEERED/PROVISIONED IN SUCH A WAY THAT THE
GOVERNMENT CAN CHANGE/REVISE CHANNELIZATION WITHOUT TELECOM
PROVIDER INTERVENTION.
A. NOTE 1 (JITTER): IN A STEADY-STATE CONDITION, THE PATTERN OF
SYNCHRONOUS TRANSPORT SIGNAL (STS) POINTER ADJUSTMENTS, SDN TO SDN
(END-TO-END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL
BE NO MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH THE
DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSI T1.105.03-1994) THAN THE
POINTER ADJUSTMENT SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994. DURING
TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2 TIMES PER DAY),
THE PATTERN OF STS POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END
THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR OR
LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME INTERVAL ERROR (MTIE)
OVER A PERIOD OF S SECONDS, OR WANDER, SHALL NOT EXCEED (.01S + 10000)
NANOSECONDS FOR VALUES OF S GREATER THAN 10,000.
B. WAVELENGTH TRANSMISSION SERVICES: WAVELENGTH TRANSMISSION
SERVICES FOR RATES OF 2.5GBPS SHALL BE IN ACCORDANCE WITH ITU-T
RECOMMENDATIONS G.709(03/2003), G.707(12/03), G.957(03/06), G.692(10/98) &
TELCORDIA GR253-IE4. THE PROVIDED WAVELENGTH TRANSMISSION SERVICE
SHALL NOT INHIBIT GOVERNMENT OPERATION OF UNDERLYING PROTOCOLS
AND TRANSPORT SYSTEMS SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP, O.
REMARKS CONTINUED: ATM, GIGABIT ETHERNET, AND ENCRYPTION. THE
WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL PASS ALL PAYLOAD,
PATH AND LINE OVERHEAD BYTES TRANSPARENTLY (UNTOUCHED/UNALTERED)
AND WITHOUT MONITORING SDP TO SDP. THERE SHALL NOT BE ANY LINE
TERMINATING EQUIPMENT (LTE) BETWEEN SDP AND SDP.
C. SINGLE MODE FIBER MUST BE TERMINATED TO THE LINE SIDE OF THE FIBER
TERMINATING PATCH PANEL INSTALLED AT BOTH DISA IE1 PROVIDED SERVICE
DELIVERY NODE LOCATIONS. D. THE TELECOM PROVIDER MUST CONTACT DISA
GOC TIER-II ENGINEERING UPON RECEIPT OF A VALID TSO TO ESTABLISH THE
COORDINATION AND ACTIVATION PROCESS. PRI POC: DISA GLOBAL CASA
INFRASTRUCTURE INTEGRATION LEASE BB TEAM PHONE: (C) 618-418-9813, (D)
418-9813 EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-
INTEGRATION-LEAS E-BB-T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER
(CASA RF CIRCUIT ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:
DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL 10. ONCE
TELECOM PROVIDER HAS COMPLETED INSIDE WIRING FROM THEIR FIBER
DISTRIBUTION PANEL INSTALLED IN THEIR DWDM EQUIPMENT SUITE TO THE
GOVERNMENT SERVICE DELIVERY POINT (SDP) AT EACH LOCATION, THEY MUST
ENSURE THE LIGHT LEVEL READINGS (DB LOSS) ARE ADJUSTED TO READ -3 TO -9
LOSS. ADDITIONALLY, THESE LEVELS MUST BE DOCUMENTED ON THE NOTICE
OF COMPLETION (NOC) SENT TO DITCO.
***THE VENDOR MUST TERMINATE SINGLE MODE FIBER AT BOTH LOCATIONS
IAW UNIQUE INSTALLATION FACTORS.*** 11. THE SINGLE MODE FIBER MUST
PASS A DOCUMENTED SATISFACTORY 72 HOUR END TO END TEST IAW ITU
STANDARD M.2101 PRIOR TO TURN-UP TO THE GOVERNMENT.
CIRCUIT REQUIRES THE FOLLOWING PARAMETERS:
(A) FIBER TERMINATION: SINGLE-MODE INTERFACE REQUIREMENT/INTERFACE
DATA RATE: LINE CODING, FRAME FORMAT, PHYSICAL CONNECTOR, 2.5 GBPS,
NRZ, SCRAMBLED PER ANSI T1.104-1991 (R2003). ALL OPTIONS DEFINED SC
CONNECTOR, P. REMARKS CONTINUED: SINGLE-MODE FIBER PER ANSI T1.105.06-
2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3). (B) LINE MUST REMAIN FULLY
OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY, SEVEN DAYS PER
WEEK, AT LEAST 99.5% OR BETTER. (C) ONE-HOUR RESPONSE TIME TURN-
AROUND MUST OCCUR TO REPAIR ONCE TROUBLE-CALL HAS BEEN REPORTED.
(D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED
INTO CIRCUIT. (E) SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS. (F) NO
NETWORK INTERFACE UNIT. (G) DEDICATED PATH. (H) CARRIER REQUIRED TO
HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES. (I) THE VENDOR
MUST CONDUCT A 72 HOUR SATISFACTORY END TO END TEST ON THE 2.5GB
WAVE SERVICE IAW ITU STANDARD M.2101. ADDITIONALLY, THE VENDOR TEST
SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST RESULTS AND THOSE
RESULTS MUST BE EMAILED TO THE ACCEPTING AUTHORITY FOR REVIEW. (J)
VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL CENTER. (K) THE
COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT
BY THE DGOC: PRI POC: DISA GLOBAL CASA INFRASTRUCTURE INTEGRATION
LEASE BB TEAM PHONE: (C) 618-418-9813, (D) 418-9813 EMAIL:
DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-LEAS E-BB-
T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER (CASA RF CIRCUIT
ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:
DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL (L) THE
VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NUMBER AND THE 1-800
TROUBLE REPORT NUMBER TO THE ACCEPTING AUTHORITY PRIOR TO THE
GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE COMPLETED AND
TESTED PROPERLY IAW THE ORDER PRIOR TO TURN-UP TO THE GOVERNMENT. 3.
VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE
MODE FIBER IAW UNIQUE INSTALLATION FACTORS. 4. INSIDE WIRING IS
AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS. 5. VENDOR MUST
COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO
REQUIRING ACCESS TO FACILITIES AT BOTH USER Q. REMARKS CONTINUED:
LOCATIONS. 6. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT
AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR
EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT CENTER (DCCC)
SCOTT AFB, IL. TOLL FREE: 1-855-868-9500, COML: 618-418-9500, DSN: 312-418-9500.
7. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-
1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS AVAILABLE AT
<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK ON "DISA-DITCO
CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS: LINE RATE: 2.5GB. LINE CODE: NRZ. FRAME
FORMAT: SCRAMBLED IAW ANSI T1.104-1991 (R2003). 1. TEST AND ACCEPTANCE:
FIBER OPTIC 2.5GB WAVE CIRCUITS SHALL PASS A FULLY DOCUMENTED
SATISFACTORY SOAK TEST BY THE GOC AT SCOTT AFB, IL. PRIMARY: (C) 618-418-
8691, (D) 418-8691. 2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED
SHALL MEET THE FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY
BASIS. PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION: NON-
DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO 99.5%
OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC): LESS THAN
OR EQUAL TO 9%. ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005%.
SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO 0.00035.
BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO 5X 10-6.
BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR EQUAL TO
1 PER 72 HOURS. JITTER: SEE NOTE 1 (JITTER). BER: LESS THAN OR EQUAL TO
1X10-12. DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D MSEC) * WHERE
"D" IS THE SDP TO SDP TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT
CIRCLE, IN KILOMETERS. 3. ROUND TRIP DELAY (RTD) FOR THIS DISA
TRANSPORT TRUNK WILL BE MEASURED IN MILLISECONDS FROM THE
CUSTOMER'S SERVICE R. REMARKS CONTINUED: DELIVERY POINT (SDP) SITE-A
TO THE CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE
LESS THAN OR EQUAL TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE
GOVERNMENT'S MISSION. THE GOVERNMENT ACCEPTING AUTHORITY WILL
CONFIRM THE RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT
ALIGN WITH THE CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO
IMMEDIATELY IN WRITING.
File details come from the government source that posted it. Updated .