- Attachment 1 for solicitation HC101322QA281.pdf
PDF 19 KB Posted
- Solicitation number
- HC101322QA281
- Issued by
-
Defense Information Systems Agency
About this file
This solicitation requests quotes to provide, install, and maintain a protected, transparent leased OTU-4 backbone trunk for the Defense Information Systems Agency. Vendors are to submit pricing for monthly recurring charges in CLIN 0001 and applicable SLINs, and non-recurring charges in CLIN 0002 and applicable SLINs by May 30, 2022. The required service must connect two DISA IE1 provided Ciena reconfigurable optical add-drop multiplexers located at Offutt Air Force Base in Nebraska and Scott Air Force Base in Illinois. The service date and acceptance criteria are outlined in the attached inquiry document. The selected vendor must comply with commercial item terms and conditions in existing basic agreements with FAR 52.212-1, 52.212-3, 52.212-4, and 52.212-5.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| - Solicitation Sample Vendor Block Diagram and Circuit Path Maps_Version2.pdf | ||
| - HC101322QA281.v0.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 for solicitation HC101322QA281
1). DIVERSITY NOT REQUESTED. THE TELECOM PROVIDER MUST PROVIDE DITCO
COLOR POWERPOINT DRAWINGS FOR TECHNICAL REVIEW SHOWING THE ROUTE
FROM THE COMMERCIAL DEMARCS TO THE SUPPORTING CENTRAL OFFICES
AND/OR WIRING CENTERS. DRAWINGS MUST INCLUDE TOTAL FIBER MILES AND
ROUND TRIP DELAY (RTD). ADDITIONALLY, THE VENDOR IS TO PROVIDE DITCO
WITH DETAILED CIRCUIT/PATH CONNECTIVITY DIAGRAMS, IN KMZ OR KML
FORMAT, IDENTIFYING ALL POINTS OF PRESENCE (POP) FOR PROPOSAL
EVALUATION AND AS A FINAL RECORD OF THE INSTALLED PATH. THESE
DIAGRAMS MUST BE PROVIDED TO L. REMARKS CONTINUED: DISA HQ IE16
(DISA.MEADE.IE.MBX.IE16-PROVISION ING-TEAM@MAIL.MI L) FOR HISTORICAL
PURPOSES. 7. SITE SURVEYS ARE AUTHORIZED AT BOTH GOVERNMENT SITES. 8.
OTU-4 SERVICE MUST BE TERMINATED TO THE LINE SIDE OF THE FIBER
TERMINATING PATCH PANEL INSTALLED IN THE DISA IE1 PROVIDED
TERMINATING EQUIPMENT AT BOTH SERVICE DELIVERY POINTS. 9. THE
TELECOM PROVIDER MUST CONTACT DISA GOC TIER-II ENGINEERING UPON
RECEIPT OF A VALID TSO TO ESTABLISH THE COORDINATION AND ACTIVATION
PROCESS. PRI POC: DISA GLOBAL CASA INFRASTRUCTURE INTEGRATION LEASE
BB TEAM PHONE: (C) 618-418-9813, (D) 418-9813 EMAIL:
DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-L EASE-BB-
T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER (CASA RF CIRCUIT
ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL:
DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL. 10. ONCE THE
TELECOM PROVIDER HAS COMPLETED INSIDE WIRING FROM THE DWDM
EQUIPMENT SUITE TO THE GOVERNMENT SERVICE DELIVERY POINT (SDP) AT
EACH LOCATION, THEY MUST ENSURE THE LIGHT LEVEL READINGS (DB LOSS)
ARE ADJUSTED TO READ -3 TO -9 LOSS. ADDITIONALLY, THESE LEVELS MUST BE
DOCUMENTED ON THE NOTICE OF COMPLETION (NOC) SENT TO DITCO. 11. THE
VENDOR MUST TERMINATE OTU-4 SERVICE AT BOTH LOCATIONS IAW UNIQUE
INSTALLATION FACTORS. 12. OTU-4 SERVICE MUST PASS A DOCUMENTED
SATISFACTORY 72 HOUR END TO END TEST IAW ITU STANDARD M.2401 PRIOR TO
TURN UP TO THE GOVERNMENT.
1. VENDOR MUST MEET SVC DATE. 2. CIRCUIT REQUIRES THE FOLLOWING
PARAMETERS: (A) FIBER TERMINATION: SINGLE-MODE INTERFACE
REQUIREMENT/INTERFACE DATA RATE: LINE CODING, FRAME FORMAT,
PHYSICAL CONNECTOR, OTU-4, PM-QPSK (G.709 COMPLIANT LR4 BASED OTU4
SIGNAL). ALL OPTIONS DEFINED SC CONNECTOR, SINGLE-MODE FIBER PER ANSI
T1.105.06-2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3). (B) LINE MUST REMAIN
FULLY OPERATIONAL AND AVAILABLE TO USERS M. REMARKS CONTINUED: 24
HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER. (C) ONE-
HOUR RESPONSE TIME TURN-AROUND MUST OCCUR TO REPAIR ONCE TROUBLE-
CALL HAS BEEN REPORTED. (D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT)
NOT TO BE ENGINEERED INTO CIRCUIT. (E) SINGLE MODE FIBER TERMINATIONS
"SC" CONNECTORS. (F) NO NETWORK INTERFACE UNIT. (G) DEDICATED PATH. (H)
CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT
OUTAGES. (I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY END TO
END TEST ON THE OTU-4 SERVICE IAW ITU STANDARD M.2401. ADDITIONALLY,
THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST
RESULTS AND THOSE RESULTS MUST BE EMAILED TO THE ACCEPTING
AUTHORITY FOR REVIEW. (J) VENDOR MUST HAVE A 24X7 NETWORK
OPERATIONAL CENTER FOR THIS OTU-4 SERVICE. (K) THE COMMERCIAL CIRCUIT
WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY THE DGOC: PRI POC:
DISA GLOBAL CASA INFRASTRUCTURE INTEGRATION LEASE BB TEAM PHONE:
(C) 618-418-9813, (D) 418-9813 EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-
INFRASTRUCTURE-INTEGRATION-L EASE-BB-T@MAIL.MIL ALT POC:
ORGANIZATIONAL NUMBER (CASA RF CIRCUIT ACTIVATIONS) PHONE: (C) 618-
418-8691, (D) 418-8691 EMAIL: DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-
ACTIVATIONS@MAIL.MIL (L) THE VENDOR MUST PROVIDE THE LONG HAUL
CIRCUIT NUMBER AND THE 1-800 TROUBLE REPORT NUMBER TO THE ACCEPTING
AUTHORITY PRIOR TO THE GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING
MUST BE COMPLETED AND TESTED PROPERLY IAW THE ORDER PRIOR TO TURN-
UP TO THE GOVERNMENT. 3. VENDOR IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF OTU-4 SERVICE IAW UNIQUE INSTALLATION FACTORS. 4.
INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS.
5. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE
PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS. 6. FOR
UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT
PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR N. REMARKS
CONTINUED: EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT
CENTER (DCCC) SCOTT AFB, IL. TOLL FREE: 1-855-868-9500, COML: 618-418-9500,
DSN: 312-418-9500. 7. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW
DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS
AVAILABLE AT <HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK
ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE COMMERCIAL
COMMUNICATIONS ACQUISITION PROCEDURES."
MINIMUM TECHNICAL SPECIFICATIONS: SPECIFIC FORMAT TO BE USED IS: LINE
RATE: OTU-4 LINE CODE: PM-QPSK (G.709 COMPLIANT LR4 BASED OTU4 SIGNAL)
1. TEST AND ACCEPTANCE: OTU-4 CIRCUITS SHALL PASS A FULLY DOCUMENTED
SATISFACTORY SOAK TEST BY THE CONUS GNOSC AT SCOTT AFB, IL. PRIMARY:
(C) 618-220-8691 (D) 770-8691. O. REMARKS CONTINUED: WILL CONFIRM THE RTD
DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN WITH THE
CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO IMMEDIATELY IN
WRITING. (** CSA TO DISC **) CARR 000025 EBM (** ADDITIONAL PROVISIONING
INFORMATION **) (ORG ACCT) DISN FIBER OPTIC BACKBONE & O/W CONTROL P.
REMARKS CONTINUED: 2. OTU-4 SERVICE PROVIDED SHALL MEET THE
FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY BASIS.
PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION: NON-
DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO 99.5%
OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC): LESS THAN
OR EQUAL TO 9%. ERRORED SECONDS (ES): LESS THAN OR EQUAL TO 0.005%.
SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO 0.00035.
BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO 5 X 10-6.
BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR EQUAL TO
1 PER 72 HOURS. BER: LESS THAN OR EQUAL TO 1X10-12. DELAY (ONE WAY): *
LESSER OF 10 MSEC OR (0.01 X D MSEC) * WHERE "D" IS THE SDP TO SDP
TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT CIRCLE, IN
KILOMETERS. 3. ROUND TRIP DELAY (RTD) FOR THIS DISA TRANSPORT TRUNK
WILL BE MEASURED IN MILLISECONDS FROM THE CUSTOMER'S SERVICE
DELIVERY POINT (SDP) SITE-A TO THE CUSTOMER'S SERVICE DELIVERY POINT
(SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR EQUAL TO 10 MILLISECONDS TO
EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION. THE GOVERNMENT
ACCEPTING AUTHORITY Q. REMARKS CONTINUED: FUNDING TCO APL: (** ON
BEHALF OF **) DEFENSE INFORMATION SYSTEMS AGENCY (DISA); (** FUNDING
APPROVAL **) THIS REQUIREMENT IS A BONA FIDE NEED OF FY22 AND DISA FY22
FUNDING INFORMATION IS AVAILABLE IN DISA'S TELECOMMUNICATIONS
INVENTORY AND BILLING INFORMATION (TIBI) APPLICATION. R. JUSTIFICATION
OF SERVICE REQUESTED: THIS ACTION SUPPORTS DISN TRANSPORT BACKBONE
SUSTAINMENT. S. COMPLETION REPORT: (1) STATION DESIGNATED IN
PARAGRAPH 2H AS CCO/CMO WILL SUBMIT COMPLETION REPORT IAW DISAC
310-130-1, SUPP 1, 2, 3 FORMAT OR DISAC 310-70-1. REPORT WILL BE ADDRESSED
TO ORIGINATOR AND ALL ADDRESSEES OF THIS (TSO). (2) STATIONS IN PARA 3
OF THIS (TSO) ARE RESPONSIBLE FOR VERIFYING IN-STATION DETAILS AND
FORWARDING THE CORRECT INFORMATION, IF ANY DISCREPANCIES ARE
NOTED, TO THE CCO/CMO DESIGNATED IN PARA 2H. THE CCO/CMO WILL SUBMIT
CORRECTIONS TO DISA VIA "EXCEPTION REPORT" IAW DISAC 310-130-1, CHAP 2.
T. IMPLEMENTATION ASSISTANCE: FOR CIRCUIT INSTALLATION ASSISTANCE
WITH THE COMMERCIAL LEASED PATH, CONTACT DCP COMMERCIAL
ACTIVATION TEAM (CAT) AT D312-850-0820, C614-692-0820. U. DD FORM 1368: DD
FORM 1368'S (MODIFIED USE OF LEASED COMMUNICATION FACILITIES), OR
EMAIL EQUIVALENT, WILL BE SUBMITTED, AS REQUIRED, ON THIS CIRCUIT IAW
DISAC-DITCO 350-135-1 BY THE STATION DESIGNATED IN PARAGRAPH 2H AS
CCO/CMO. GUIDANCE ON SUBMISSION IS AVAILABLE AT
HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON "350-
135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES."
File details come from the government source that posted it. Updated .