*** ATTACHMENT 1 FOR SOLICITATION HC101321QA536 ***
ATTENTION HERNDON, VA LOCATION: THIS REQUIREMENT MUST BE
ENGINEERED AND PROVISIONED TOTALLY DIVERSE END TO END TO
GOVERNMENT'S SERVICE DELIVERY POINTS (SDP'S) FROM TSR RU05AUG217279,
MEANING THAT PHYSICAL PATHS ARE TOTALLY SEPARATE INCLUDING MAN
HOLES, CONDUIT, (CENTRAL OFFICE LOCATIONS), AND FIBER BUILDS.
ADDITIONALLY AS A MINIMUM THERE MUST BE A 50 METER PHYSICAL
SEPARATION FROM TSR RU05AUG217279. THE 50 METER SEPARATION IS WAIVED
INSIDE BLDG 13555 FOR HERNDON, VA LOCATION.*** 7. THE TELECOM PROVIDER
MUST PROVIDE DITCO COLOR POWERPOINT DRAWINGS FOR TECHNICAL REVIEW
SHOWING THE ROUTES FROM THE COMMERCIAL M. REMARKS CONTINUED:
DEMARCS TO THE SUPPORTING CENTRAL OFFICES AND/OR WIRING CENTERS.
DRAWINGS MUST INCLUDE SEPARATION DISTANCES BETWEEN DIVERSE
REQUIREMENTS, TOTAL FIBER MILES AND ROUND TRIP DELAY (RTD), AND FIBER
ROUTES RED LINED END TO END SO THE GOVERNMENT CAN CONFIRM PHYSICAL
END TO END DIVERSITY REQUIREMENTS ARE MET. ADDITIONALLY, THE VENDOR
IS TO PROVIDE DITCO WITH DETAILED CIRCUIT/PATH CONNECTIVITY
DIAGRAMS, IN KMZ OR KML FORMAT, IDENTIFYING ALL POINTS OF PRESENCE
(POP) FOR EVALUATION AND AS A FINAL RECORD OF THE INSTALLED PATH.
THESE DIAGRAMS MUST BE PROVIDED TO DISA HQ IE16
(DISA.MEADE.IE.MBX.IE16-PROVISIONING-TEAM@MAIL.MI L) FOR HISTORICAL
PURPOSES. 8. THE VENDOR MUST PROVIDE LIGHT LEVEL READINGS (SIGNAL
STRENGTH IN DBM) ON THE EXTENSION FROM COMMERCIAL POP TO THE
GOVERNMENT SERVICE DELIVERY POINT (SDP) AT THE "A" AND "Z" LOCATION
PRIOR TO CIRCUIT TURN OVER TO THE GOVERNMENT ENSURING LEVELS ARE
WITHIN SPECS. LIGHT LEVELS MUST BE ADJUSTED TO -3 TO -9 DBM. 9. THE
VENDOR MUST TERMINATE 10GB ETHERNET SERVICE AT SERVICE DELIVERY
LOCATIONS, IAW UNIQUE INSTALLATION FACTORS. 10. THE VENDOR MUST
CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO INSTALLATION A T BOTH
LOCATIONS. 11. THE VENDOR MUST CONTACT DISA GOC IP BACKBONE
ENGINEERING AND IMPLEMENTATION GROUP UPON RECEIPT OF A VALID TSO TO
ESTABLISH THE COORDINATION AND ACTIVATION PROCESS. PHONE: (C) 618-418-
8627, (D) 418-8627. 12. THE VENDOR MUST CONTACT DISA GOC TIER-II
ENGINEERING 48 HOURS PRIOR TO BEGINNING THEIR END-TO-END TESTING.
PHONE: (C) 618-418-8627, (D) 418-8627. 13. THE PROVIDER MUST CONDUCT A
SATISFACTORY 24-HOUR TEST FROM THE DROP SIDE OF THEIR OR LOCAL
EXCHANGE CARRIERS FDP INSTALLED IN THEIR EQUIPMENT SUITE AT THE "A"
LOCATION TO THEIR OR LOCAL EXCHANGE CARRIERS FDP INSTALLED IN THEIR
EQUIPMENT SUITE AT THE "Z" LOCATION AND MUST INCLUDE THE EXTENSION
BETWEEN THE COMMERCIAL DEMARC AND THE GOVERNMENT'S SDP. VENDOR
MUST ENSURE TEST SETS ARE N. REMARKS CONTINUED: PLACED AT THE DROP
SIDE AT THE "A" LOCATION AND AT THE "Z" LOCATION. TESTING MUST BE
SATISFACTORY PRIOR TO TURN OVER TO THE GOVERNMENT FOR ACCEPTANCE
TESTING. THE VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW THE FULL
ITU-T.Y.1564 BENCH MARKING METHODOLOGY FOR NETWORK INTERCONNECT
DEVICES STANDARD, AND AT THE COMMITTED INFORMATION RATE (CIR) IAW
ITU-T-Y.1564.
1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS: (A) FIBER
TERMINATION: FRAME FORMAT: 10GB ETHERNET (OPTICAL HANDOFF-10GB
ETHERNET-LAN-PHY-SINGLE MODE FIBER), 1310NM. "SC" OR "LC" CONNECTORS
AS DETERMINED BY SITE SURVEY. NOTE: WHEN EXTENDED REACH OPTICS ARE
USED THAT CHANGE THE TX/RX WAVELENGTH OF THE OPTIC, THE VENDOR
WILL NOTIFY THE GOVERNMENT 30 DAYS PRIOR TO DELIVERY. (B) COMMITTED
INFORMATION RATE (CIR): 10GB. (C) ETHERNET FRAME SIZE WILL BE
CONFIGURED TO SUPPORT MAXIMUM TRANSMISSION UNIT (MTU) OF 9000
OCTETS (BYTES) JUMBO FRAMES. (D) NO NETWORK INTERFACE UNIT,
DEDICATED PATH. (E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO
BE ENGINEERED INTO CIRCUIT. (F) TESTING CRITERIA: VENDOR MUST TEST THE
CIRCUIT FOR 24 HOURS IAW THE FULL ITU-T.Y.1564 BENCH MARKING
METHODOLOGY FOR NETWORK INTERCONNECT DEVICES STANDARD, AND AT
THE COMMITTED INFORMATION RATE (CIR) IAW ITU-T-Y.1564. NOTE: ETHERNET
FRAME SIZE DESIGNATOR 'H' (MTU) IS EQUAL TO 9000 BYTES. (G) LINE MUST
REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY,
SEVEN DAYS PER WEEK, MONTHLY PERFORMANCE OF 99.5% AVAILABILITY OR
BETTER. (H) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECEIPT
OF TROUBLE. (I) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN
ANY CIRCUIT OUTAGES. (J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS
CENTER. (K) TELECOM PROVIDER MUST MAINTAIN OPERATIONS, MAINTENANCE
AND ADMINISTRATION MONITORING OF ETHERNET CIRCUIT. O. REMARKS
CONTINUED: (L) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF
THE GOVERNMENT BY THE DISA GOC IP BACKBONE ENGINEERING AND
IMPLEMENTATION GROUP, SCOTT AFB, IL. (C) 618-418-8627, (D) 418-8627. 2.
VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF THE SERVICE IAW THE UNIQUE INSTALLATION FACTORS. 3.
INSIDE WIRING IS AUTHORIZED IAW THE UNIQUE INSTALLATION FACTORS. 4.
VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE
PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS. 5.
VENDOR MUST CONTACT DISA GOC TIER-II ENGINEERING 48 HOURS PRIOR TO
BEGINNING THEIR END-TO-END TESTING. 6. ALL EQUIPMENT AND CIRCUIT
PROBLEMS WILL BE REPORTED BY PHONE TO THE DISA GOC IP BACKBONE
ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL. PRIMARY: (C) 618-
418-9950, (D) 418-9950 TOLL FREE: 855-868-9950. 7. DD FORM 1368 WILL BE
SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB,
IL. GUIDANCE ON SUBMISSION IS AVAILABLE AT
<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK ON "DISA-DITCO
CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS: LINE RATE: 10.3125 GIGABITS/S, +- 100 PPM LINE
CODE: OPTICAL 1. TEST AND ACCEPTANCE: THIS CIRCUIT SHALL PASS A FULLY
DOCUMENTED, SATISFACTORY, 72 HOUR SOAK TEST BY DISA GOC AT SCOTT
AFB, IL. PRIMARY: (C) 618-418-8627 (D) 418-8627. 2. ERROR PERFORMANCE: ERROR
PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING PARAMETER
THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN
99.5% OR BETTER. FRAME LOSS SHALL BE EQUAL TO ZERO WHEN TESTING AT 10
GIGABIT HIGHEST FRAME RATE,AND SHALL MEET ITU-T-Y.1564 STANDARDS.
JITTER SHALL BE LESS THAN 3 MSEC. DELAY SHALL BE BETTER THAN 10 MSEC. 3.
MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL P. REMARKS
CONTINUED: BE GREATER THAN 24 HOURS. 4. ROUND TRIP DELAY (RTD) FOR
THIS DISA TRANSPORT TRUNK WILL BE MEASURED IN MILLISECONDS FROM THE
CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-A TO THE CUSTOMER'S
SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR
EQUAL TO 10 (10MS (<450)/15MS (450-1000)/ 20MS (1000-1500)/29MS (>1500))
MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S MISSION. THE
GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE RTD DURING THE
TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN WITH THE CONTRACTORS
PROPOSAL, DISA IE161 WILL NOTIFY DITCO IMMEDIATELY IN WRITING.