CIRCUIT SPECIFICATIONS:

MINIMUM TECHNICAL SPECIFICATIONS:

SPECIFIC FORMAT TO BE USED IS: LINE RATE: 2.5GB. LINE CODE: NRZ

FRAME FORMAT: SCRAMBLED IAW ANSI T1.104-1991 (R2003)

1. TEST AND ACCEPTANCE: FIBER OPTIC 2.5GB WAVE CIRCUITS SHALL PASS A

FULLY DOCUMENTED SATISFACTORY SOAK TEST BY THE CONUS GNOSC AT

SCOTT AFB, IL. PRIMARY: (C) 618-418-8691 (D) 418-8691

2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL MEET THE

FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY BASIS.

PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION:

NON-DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO

99.5% OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC):

LESS THAN OR EQUAL TO 9 % ERRORED SECONDS (ES): LESS THAN OR EQUAL TO

0.005 % SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO 0.00035

BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO 5 X 10-6

BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR EQUAL TO

1 PER 72 HOURS JITTER SEE NOTE 1 (JITTER) BER: LESS THAN OR EQUAL TO

1X10-12 DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D MSEC) * WHERE

"D" IS THE SDP TO SDP TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT

CIRCLE, IN KILOMETERS.

CIRCUIT SPECIFICATIONS CONTINUED: 3. THE ROUND TRIP DELAY (RTD) FOR

THIS DISA TRANSPORT TRUNK WILL BE MEASURED IN MILLISECONDS FROM

THE CUSTOMERS SERVICE DELIVERY POINT (SDP) SITE-A TO THE CUSTOMERS

SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR

EQUAL TO 26 MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S

MISSION. THE GOVERNMENT RESERVES THE RIGHT TO ACCEPT A HIGHER RTD

ONLY IF SUPPORTED BY ACTUAL PHYSICAL FIBER DISTANCE BETWEEN THE

TWO END LOCATIONS. ADDITIONALLY THE GOVERNMENT RESERVES THE

RIGHT TO REJECT A PROPOSED PATH IF DEEMED EXCESSIVELY LONG WITHOUT

WRITTEN JUSTIFICATION IN THE PROPOSAL. JUSTIFICATION FOR EXCESSIVE

FIBER MILEAGE COULD BE DIVERSITY/AVOIDANCE REQUIREMENTS, LIMITED

INFRASTRUCTURE, AVAILABLE PROVIDERS, GEOGRAPHIC AND PHYSICAL

LIMITATION. THE GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE

RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN WITH

THE CONTRACTORS PROPOSAL DISA IE161 WILL NOTIFY DITCO

IMMEDIATELY IN WRITING. (**UNIQ INSTALL FACTORS**) (SP A) 542, ROOM 1

TO THEIR POINT OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 542,

ROOM 1. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON

THIS ORDER THE EXACT TERMINATION POINT WHEN SERVICE IS COMPLETE.

Q. REMARKS CONTINUED: CIRCUIT SPEC CONTINUED:

(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM,

TELCO (2) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL CARRIER

SYSTEM) AMPLIFYING INFO: A. VENDOR IS RESPONSIBLE FOR INSTALLATION

AND MAINTENANCE OF SINGLE MODE FIBER FROM THE LINE SIDE OF THE

DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE

ODXC SUITE (UMSWHEC020) BLDG 542, ROOM 1 TO THE DROP SIDE OF THE

COMMERCIAL FIBER POINT OF PRESENCE [FIBER DISTRIBUTION PANEL (FDP)]

BLDG 542, ROOM 1. TERMINATE WITH "SC" CONNECTORS TO THE DISA PATCH

PANEL. B. VENDOR MUST PROVIDE FIBER STRANDS FROM THE SITE

PROVIDED FIBER PATCH PANELTO THE DROP SIDE OF THEIR POP/FIBER

DISTRIBUTION PANEL WITHOUT SPLICING AND OR USE OF CONNECTORS TO

CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE

BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS. C. THE LENGTH OF

SINGLE MODE FIBER JUMPERS REQUIRED WILL BE BASED ON THE LOCATION

OF THE VENDORS POINT OF PRESENCE. D. THE CIRCUIT MUST BE TAGGED WITH

THE VENDOR'S CIRCUIT ID AS APPLICABLE AT THE DROP SIDE OF THEIR POINT

OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 542, ROOM