ATTACHMENT 1 FOR SOLICITATION HC101320QA534
CIRCUIT SPECIFICATIONS:
MINIMUM TECHNICAL SPECIFICATIONS:
SPECIFIC FORMAT TO BE USED IS: LINE RATE: 2.5GB. LINE CODE: NRZ
FRAME FORMAT: SCRAMBLED IAW ANSI T1.104-1991 (R2003)
1. TEST AND ACCEPTANCE: FIBER OPTIC 2.5GB WAVE CIRCUITS SHALL PASS A
FULLY DOCUMENTED SATISFACTORY SOAK TEST BY THE CONUS GNOSC AT
SCOTT AFB, IL. PRIMARY: (C) 618-418-8691 (D) 418-8691
2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL MEET THE
FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY BASIS.
PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION:
NON-DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO
99.5% OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC):
LESS THAN OR EQUAL TO 9 % ERRORED SECONDS (ES): LESS THAN OR EQUAL TO
0.005 % SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO 0.00035
BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO 5 X 10-6
BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR EQUAL TO
1 PER 72 HOURS JITTER SEE NOTE 1 (JITTER) BER: LESS THAN OR EQUAL TO
1X10-12 DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D MSEC) * WHERE
"D" IS THE SDP TO SDP TRANSMISSION DISTANCE, MEASURED SHORTEST GREAT
CIRCLE, IN KILOMETERS.
CIRCUIT SPECIFICATIONS CONTINUED: 3. THE ROUND TRIP DELAY (RTD) FOR
THIS DISA TRANSPORT TRUNK WILL BE MEASURED IN MILLISECONDS FROM
THE CUSTOMERS SERVICE DELIVERY POINT (SDP) SITE-A TO THE CUSTOMERS
SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE LESS THAN OR
EQUAL TO 26 MILLISECONDS TO EFFECTIVELY SUPPORT THE GOVERNMENT'S
MISSION. THE GOVERNMENT RESERVES THE RIGHT TO ACCEPT A HIGHER RTD
ONLY IF SUPPORTED BY ACTUAL PHYSICAL FIBER DISTANCE BETWEEN THE
TWO END LOCATIONS. ADDITIONALLY THE GOVERNMENT RESERVES THE
RIGHT TO REJECT A PROPOSED PATH IF DEEMED EXCESSIVELY LONG WITHOUT
WRITTEN JUSTIFICATION IN THE PROPOSAL. JUSTIFICATION FOR EXCESSIVE
FIBER MILEAGE COULD BE DIVERSITY/AVOIDANCE REQUIREMENTS, LIMITED
INFRASTRUCTURE, AVAILABLE PROVIDERS, GEOGRAPHIC AND PHYSICAL
LIMITATION. THE GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE
RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN WITH
THE CONTRACTORS PROPOSAL DISA IE161 WILL NOTIFY DITCO
IMMEDIATELY IN WRITING. (**UNIQ INSTALL FACTORS**) (SP A) 542, ROOM 1
TO THEIR POINT OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 542,
ROOM 1. ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON
THIS ORDER THE EXACT TERMINATION POINT WHEN SERVICE IS COMPLETE.
Q. REMARKS CONTINUED: CIRCUIT SPEC CONTINUED:
(1) FIBER CABLE X-CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM,
TELCO (2) COMMERCIAL FIBER POINT OF PRESENCE (COMMERCIAL CARRIER
SYSTEM) AMPLIFYING INFO: A. VENDOR IS RESPONSIBLE FOR INSTALLATION
AND MAINTENANCE OF SINGLE MODE FIBER FROM THE LINE SIDE OF THE
DISA IE1 PROVIDED FIBER TERMINATING PATCH PANEL INSTALLED IN THE
ODXC SUITE (UMSWHEC020) BLDG 542, ROOM 1 TO THE DROP SIDE OF THE
COMMERCIAL FIBER POINT OF PRESENCE [FIBER DISTRIBUTION PANEL (FDP)]
BLDG 542, ROOM 1. TERMINATE WITH "SC" CONNECTORS TO THE DISA PATCH
PANEL. B. VENDOR MUST PROVIDE FIBER STRANDS FROM THE SITE
PROVIDED FIBER PATCH PANELTO THE DROP SIDE OF THEIR POP/FIBER
DISTRIBUTION PANEL WITHOUT SPLICING AND OR USE OF CONNECTORS TO
CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT BE
BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS. C. THE LENGTH OF
SINGLE MODE FIBER JUMPERS REQUIRED WILL BE BASED ON THE LOCATION
OF THE VENDORS POINT OF PRESENCE. D. THE CIRCUIT MUST BE TAGGED WITH
THE VENDOR'S CIRCUIT ID AS APPLICABLE AT THE DROP SIDE OF THEIR POINT
OF PRESENCE (FIBER DISTRIBUTION PANEL) BLDG 542, ROOM