ATTACHMENT 1 FOR SOLICITATION HC101320QA156
1. IN A STEADY-STATE CONDITION, THE PATTERN OF SYNCHRONOUS
TRANSPORT SIGNAL (STS) POINTER ADJUSTMENTS, SDN TO SDN (END-TO-
END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE NO
MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH THE
DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSI T1.105.03-1994) THAN
THE POINTER ADJUSTMENT SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994.
DURING TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2 TIMES
PER DAY), THE PATTERN OF STS POINTER ADJUSTMENTS, SDN TO SDN (END-
TO-END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE
FOUR OR LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME INTERVAL
ERROR (MTIE) OVER A PERIOD OF S SECONDS, OR WANDER, SHALL NOT
EXCEED (.01S + 10000) NANOSECONDS FOR VALUES OF S GREATER THAN
10,000. B. WAVELENGTH TRANSMISSION SERVICES: WAVELENGTH
TRANSMISSION SERVICES FOR RATES OF 2.5GBPS SHALL BE IN ACCORDANCE
WITH ITU-T RECOMMENDATIONS G.709(03/2003), G.707(12/03), G.957(03/06),
G.692(10/98) & TELCORDIA GR253-IE4. THE PROVIDED WAVELENGTH
TRANSMISSION SERVICE SHALL NOT INHIBIT GOVERNMENT OPERATION OF
UNDERLYING PROTOCOLS AND TRANSPORT SYSTEMS SUCH AS, BUT NOT
LIMITED TO, SONET/SDH, IP, ATM, GIGABIT ETHERNET, AND ENCRYPTION.
THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL PASS ALL
PAYLOAD, PATH AND LINE OVERHEAD BYTES TRANSPARENTLY
(UNTOUCHED/UNALTERED) AND WITHOUT MONITORING SDP TO SDP. THERE
SHALL NOT BE ANY LINE TERMINATING EQUIPMENT (LTE) BETWEEN SDP AND
SDP. C. 2.5GB WAVE SERVICE MUST BE TERMINATED TO THE LINE SIDE OF
THE FIBER TERMINATING PATCH PANEL INSTALLED IN THE DISA IE1
PROVIDED ODXC SUITE INSTALLED AT JACKSONVILLE NAS AND THE FIBER
TERMINATING PATCH PANEL INSTALLED IN THE DISA IE1 PROVIDED MSPP
SUITE AT PATRICK AFB. THE SINGLE MODE FIBER MUST PASS A
DOCUMENTED SATISFACTORY 72 HOUR END TO END TEST IAW ITU
STANDARD M.2101 PRIOR TO TURN UP TO THE GOVERNMENT.
2. (A) FIBER TERMINATION: SINGLE-MODE INTERFACE
REQUIREMENT/INTERFACE DATA RATE: LINE CODING, FRAME FORMAT,
PHYSICAL CONNECTOR, 2.5 GBPS, NRZ, SCRAMBLED PER ANSI T1.104-1991
(R2003). ALL OPTIONS DEFINED SC CONNECTOR, SINGLE-MODE FIBER PER
ANSI T1.105.06-2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3).
(B) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24
HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.
(C) ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR TO REPAIR
ONCE TROUBLE-CALL HAS BEEN REPORTED.
(D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE
ENGINEERED INTO CIRCUIT.
(E) SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS
(F) NO NETWORK INTERFACE UNIT.
(G) DEDICATED PATH.
(H) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY
CIRCUIT OUTAGES.
(I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY END TO END
TEST ON THE 10 WAVE SERVICE IAW ITU STANDARD M.2101. ADDITIONALLY,
THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST
RESULTS AND THOSE RESULTS MUST BE EMAILED TO THE ACCEPTING
AUTHORITY FOR REVIEW.
(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL CENTER.
(K) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE
GOVERNMENT BY THE CONUS GNOSC: PRI POC: CONTACT: MIKE REEVES (C)
618-418-8973 (D) 418-8973 ALT POC: CONTACT: DON NORDENHOLT (C) 618-418-
8643 (D) 418-8643 ALT POC: CONTACT: AARON SMITH (C) 618-418-9820 (D) 418-
9820 ALT POC: CONTACT: BOB RISKY (C) 618-418-8632 (D) 418-8632 ALT POC:
ORGANIZATIONAL NUMBER (C) 618-418-8691 (D) 418-8691
(L) THE VENDOR MUST PROVIDE: 1) THE LONG HAUL CIRCUIT NUMBER AND
THE 1-800 TROUBLE REPORT NUMBER TO THE ACCEPTING AUTHORITY PRIOR
TO THE GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE
COMPLETED AND TESTED PROPERLY IAW THE ORDER PRIOR TO TURNUP TO
THE GOVERNMENT.
3. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF
SINGLE MODE FIBER IAW UNIQUE INSTALLATION FACTORS.
4. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION
FACTORS.
5. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE
PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS.
6. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT AND/OR
CIRCUIT PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR
EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT CENTER
(DCCC) SCOTT AFB, IL. TOLL FREE: 1-855-868-9500 COML: 618-418-9500 DSN: 312-
418-9500
7. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-
135-1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS AVAILABLE AT
<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK ON "DISA-
DITCO CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS
ACQUISITION PROCEDURES." MINIMUM TECHNICAL SPECIFICATIONS: O.
PURPOSE STATEMENT CONTINUED: SPECIFIC FORMAT TO BE USED IS: LINE
RATE: 2.5GB LINE CODE: NRZ FRAME FORMAT: SCRAMBLED IAW ANSI T1.104-
1991 (R2003) P. PURPOSE STATEMENT CONTINUED: (** ADDITIONAL
PROVISIONING INFORMATION **) (ORG ACCT) DISN FIBER OPTIC BACKBONE &
O/W CONTROL
TEST & ACCEPTANCE INSTRUCTIONS: SPECIFIC FORMAT TO BE USED IS:
1. LINE RATE: 2.5GB LINE CODE: NRZ FRAME FORMAT: SCRAMBLED IAW ANSI
T1.104-1991 (R2003) 1. TEST AND ACCEPTANCE: FIBER OPTIC 2.5GB WAVE
CIRCUITS SHALL PASS A FULLY DOCUMENTED SATISFACTORY SOAK TEST BY
THE CONUS GNOSC AT SCOTT AFB, IL. PRIMARY: (C) 618-220-8691 (D) 770-8691
2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL MEET THE
FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY BASIS.
PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION: NON-
DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO
99.5% OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC):
LESS THAN OR EQUAL TO 9% ERRORED SECONDS (ES): LESS THAN OR EQUAL
TO 0.005% SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO
0.00035 BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO
5 X 10-6 BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR
EQUAL TO 1 PER 72 HOURS JITTER SEE NOTE 1 (JITTER) BER: LESS THAN OR
EQUAL TO 1X10-12 DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D
MSEC) * WHERE "D" IS THE SDP TO SDP TRANSMISSION DISTANCE,
MEASURED SHORTEST GREAT CIRCLE, IN KILOMETERS.