ATTACHMENT 1 FOR SOLICITATION HC101320QA156

1. IN A STEADY-STATE CONDITION, THE PATTERN OF SYNCHRONOUS

TRANSPORT SIGNAL (STS) POINTER ADJUSTMENTS, SDN TO SDN (END-TO-

END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE NO

MORE STRESSFUL (I.E., CREATE MORE JITTER THROUGH THE

DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF ANSI T1.105.03-1994) THAN

THE POINTER ADJUSTMENT SEQUENCE IN FIGURE 5 OF ANSI T1.105.03-1994.

DURING TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2 TIMES

PER DAY), THE PATTERN OF STS POINTER ADJUSTMENTS, SDN TO SDN (END-

TO-END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE

FOUR OR LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME INTERVAL

ERROR (MTIE) OVER A PERIOD OF S SECONDS, OR WANDER, SHALL NOT

EXCEED (.01S + 10000) NANOSECONDS FOR VALUES OF S GREATER THAN

10,000. B. WAVELENGTH TRANSMISSION SERVICES: WAVELENGTH

TRANSMISSION SERVICES FOR RATES OF 2.5GBPS SHALL BE IN ACCORDANCE

WITH ITU-T RECOMMENDATIONS G.709(03/2003), G.707(12/03), G.957(03/06),

G.692(10/98) & TELCORDIA GR253-IE4. THE PROVIDED WAVELENGTH

TRANSMISSION SERVICE SHALL NOT INHIBIT GOVERNMENT OPERATION OF

UNDERLYING PROTOCOLS AND TRANSPORT SYSTEMS SUCH AS, BUT NOT

LIMITED TO, SONET/SDH, IP, ATM, GIGABIT ETHERNET, AND ENCRYPTION.

THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL PASS ALL

PAYLOAD, PATH AND LINE OVERHEAD BYTES TRANSPARENTLY

(UNTOUCHED/UNALTERED) AND WITHOUT MONITORING SDP TO SDP. THERE

SHALL NOT BE ANY LINE TERMINATING EQUIPMENT (LTE) BETWEEN SDP AND

SDP. C. 2.5GB WAVE SERVICE MUST BE TERMINATED TO THE LINE SIDE OF

THE FIBER TERMINATING PATCH PANEL INSTALLED IN THE DISA IE1

PROVIDED ODXC SUITE INSTALLED AT JACKSONVILLE NAS AND THE FIBER

TERMINATING PATCH PANEL INSTALLED IN THE DISA IE1 PROVIDED MSPP

SUITE AT PATRICK AFB. THE SINGLE MODE FIBER MUST PASS A

DOCUMENTED SATISFACTORY 72 HOUR END TO END TEST IAW ITU

STANDARD M.2101 PRIOR TO TURN UP TO THE GOVERNMENT.

2. (A) FIBER TERMINATION: SINGLE-MODE INTERFACE

REQUIREMENT/INTERFACE DATA RATE: LINE CODING, FRAME FORMAT,

PHYSICAL CONNECTOR, 2.5 GBPS, NRZ, SCRAMBLED PER ANSI T1.104-1991

(R2003). ALL OPTIONS DEFINED SC CONNECTOR, SINGLE-MODE FIBER PER

ANSI T1.105.06-2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3).

(B) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24

HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR BETTER.

(C) ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR TO REPAIR

ONCE TROUBLE-CALL HAS BEEN REPORTED.

(D) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE

ENGINEERED INTO CIRCUIT.

(E) SINGLE MODE FIBER TERMINATIONS "SC" CONNECTORS

(F) NO NETWORK INTERFACE UNIT.

(G) DEDICATED PATH.

(H) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY

CIRCUIT OUTAGES.

(I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY END TO END

TEST ON THE 10 WAVE SERVICE IAW ITU STANDARD M.2101. ADDITIONALLY,

THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST

RESULTS AND THOSE RESULTS MUST BE EMAILED TO THE ACCEPTING

AUTHORITY FOR REVIEW.

(J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONAL CENTER.

(K) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE

GOVERNMENT BY THE CONUS GNOSC: PRI POC: CONTACT: MIKE REEVES (C)

618-418-8973 (D) 418-8973 ALT POC: CONTACT: DON NORDENHOLT (C) 618-418-

8643 (D) 418-8643 ALT POC: CONTACT: AARON SMITH (C) 618-418-9820 (D) 418-

9820 ALT POC: CONTACT: BOB RISKY (C) 618-418-8632 (D) 418-8632 ALT POC:

ORGANIZATIONAL NUMBER (C) 618-418-8691 (D) 418-8691

(L) THE VENDOR MUST PROVIDE: 1) THE LONG HAUL CIRCUIT NUMBER AND

THE 1-800 TROUBLE REPORT NUMBER TO THE ACCEPTING AUTHORITY PRIOR

TO THE GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE

COMPLETED AND TESTED PROPERLY IAW THE ORDER PRIOR TO TURNUP TO

THE GOVERNMENT.

3. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF

SINGLE MODE FIBER IAW UNIQUE INSTALLATION FACTORS.

4. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION

FACTORS.

5. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE

PRIOR TO REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS.

6. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT AND/OR

CIRCUIT PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR

EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT CENTER

(DCCC) SCOTT AFB, IL. TOLL FREE: 1-855-868-9500 COML: 618-418-9500 DSN: 312-

418-9500

7. DD FORM 1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-

135-1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON SUBMISSION IS AVAILABLE AT

<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK ON "DISA-

DITCO CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS

ACQUISITION PROCEDURES." MINIMUM TECHNICAL SPECIFICATIONS: O.

PURPOSE STATEMENT CONTINUED: SPECIFIC FORMAT TO BE USED IS: LINE

RATE: 2.5GB LINE CODE: NRZ FRAME FORMAT: SCRAMBLED IAW ANSI T1.104-

1991 (R2003) P. PURPOSE STATEMENT CONTINUED: (** ADDITIONAL

PROVISIONING INFORMATION **) (ORG ACCT) DISN FIBER OPTIC BACKBONE &

O/W CONTROL

TEST & ACCEPTANCE INSTRUCTIONS: SPECIFIC FORMAT TO BE USED IS:

1. LINE RATE: 2.5GB LINE CODE: NRZ FRAME FORMAT: SCRAMBLED IAW ANSI

T1.104-1991 (R2003) 1. TEST AND ACCEPTANCE: FIBER OPTIC 2.5GB WAVE

CIRCUITS SHALL PASS A FULLY DOCUMENTED SATISFACTORY SOAK TEST BY

THE CONUS GNOSC AT SCOTT AFB, IL. PRIMARY: (C) 618-220-8691 (D) 770-8691

2. THE WAVELENGTH TRANSMISSION SERVICE PROVIDED SHALL MEET THE

FOLLOWING PERFORMANCE REQUIREMENTS ON A MONTHLY BASIS.

PERFORMANCE REQUIREMENT/PERFORMANCE SPECIFICATION: NON-

DIVERSE/NON-PROTECTED AVAILABILITY: GREATER THAN OR EQUAL TO

99.5% OR BETTER. MONTHLY SHORT INTERRUPTION EVENT COUNT (SEIC):

LESS THAN OR EQUAL TO 9% ERRORED SECONDS (ES): LESS THAN OR EQUAL

TO 0.005% SEVERELY ERRORED SECONDS (SES): LESS THAN OR EQUAL TO

0.00035 BACKGROUND BLOCK ERROR RATIO (BBER): LESS THAN OR EQUAL TO

5 X 10-6 BIT COUNT INTEGRITY (BCI)/PATTERN SLIP (PAT SLIP): LESS THAN OR

EQUAL TO 1 PER 72 HOURS JITTER SEE NOTE 1 (JITTER) BER: LESS THAN OR

EQUAL TO 1X10-12 DELAY (ONE WAY): * LESSER OF 10 MSEC OR (0.01 X D

MSEC) * WHERE "D" IS THE SDP TO SDP TRANSMISSION DISTANCE,

MEASURED SHORTEST GREAT CIRCLE, IN KILOMETERS.