Attachment 1 for solicitation HC101319QB231
MINIMUM TECHNICAL SPECIFICATIONS:
1. MEASUREMENT INTERVAL (TEST PERIOD): 24 HOURS
2. 99 PERCENT ERROR FREE SECONDS OVER THE 24 HOUR TEST
PERIOD.
3. SEVERELY ERRORED SECONDS: LESS THAN 0.2 PERCENT OVER
THE 24 HOUR TEST PERIOD.
4. DEGRADED MINUTES: LESS THAN 0.4 PERCENT OVER THE 24
HOUR TEST PERIOD.
5. BIT ERROR RATE (BER): 1 TIMES 10 TO MINUS 9.
6. RESIDUAL BIT ERROR RATE (BER): 1 TIMES 10 TO MINUS 8.
7. AVAILABILITY: 99.95 PERCENT.
8. MTTLBCI (MEAN TIME TO LOSS OF BIT COUNT INTEGRITY):
MAXIMUM OCCURRENCES: 1 (4/24 HOURS)
9. THE ROUND TRIP DELAY (RTD) FOR THIS DISA TRANSPORT TRUNK
WILL BE MEASURED IN MILLISECONDS FROM THE CUSTOMERS
SERVICE DELIVERY POINT (SDP) SITE-A TO THE CUSTOMERS
SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE
LESS THAN OR EQUAL TO 10 MILLISECONDS TO EFFECTIVELY
SUPPORT THE GOVERNMENT'S MISSION. THE GOVERNMENT
RESERVES THE RIGHT TO ACCEPT A HIGHER RTD ONLY IF
SUPPORTED BY ACTUAL PHYSICAL FIBER DISTANCE BETWEEN THE
TWO END LOCATIONS. ADDITIONALLY THE GOVERNMENT RESERVES
THE RIGHT TO REJECT A PROPOSED PATH IF DEEMED
EXCESSIVELY LONG WITHOUT WRITTEN JUSTIFICATION IN THE
PROPOSAL. JUSTIFICATION FOR EXCESSIVE FIBER MILEAGE
COULD BE DIVERSITY/AVOIDANCE REQUIREMENTS, LIMITED
INFRASTRUCTURE, AVAILABLE PROVIDERS, GEOGRAPHIC AND
PHYSICAL LIMITATION. THE GOVERNMENT ACCEPTING AUTHORITY
WILL CONFIRM THE RTD DURING THE TURN-UP AND TEST PHASE
AND IF IT DOES NOT ALIGN WITH THE CONTRACTORS PROPOSAL
DISA IE161 WILL NOTIFY DITCO IMMEDIATELY IN WRITING.
CIRCUIT SPECIFICATIONS: CONUS TERRESTRIAL - 44.736 MB, B3ZS/C-BIT - 28 CHANNELS
1) VENDOR TECHNICAL SPECIFICATIONS
LINE CODING: B3ZS
FRAME FORMAT: C-BIT PARITY
CHANNELIZATION: 28 CHANNELS
PHYSICAL TERMINATION: COAX, BNC CONNECTOR
TEST INTERVAL: 24 HOURS
AVAILABILITY: 99.5 %
% ERROR FREE SECONDS (EFS): 98.0 %
SEVERELY ERRORED SECONDS (SES): < 0.02 %
AVERAGE BIT ERROR RATE (BER): 5 X 10-9
RESIDUAL BIT ERROR RATE (RBER): 5 X 10-9
BIPOLAR VIOLATION (BPV): 0 ALLOWED
OUT OF FRAME: 0 ALLOWED
FRAME SLIP: < 1 IN 24 HOURS
DEGRADED MINUTES (DM): < 0.2 %
ROUND TRIP DELAY (RTD): < 10 MS FOR FIRST 620 MILE PLUS 1 MS FOR
EVERY 62 MILES THERE AFTER.
LOSS OF BIT COUNT INTEGRITY (LBCI): < 1 IN 24 HOURS
JITTER: ITU-T G.823 OR COMPARABLE U.S. COMMERCIAL INDUSTRY
STANDARD
TEST PATTERN: QRSS FOR DSN CIRCUITS; 2^23 FOR ALL OTHER SERVICE
TYPES
CIRCUIT SPECIFICATIONS CONTINUED: CONUS SECOND PART OF DS-3 CIRCUIT PARAMETERS
2) VENDOR WILL TEST COMMERCIAL END TO END, IF THE VENDOR EXTENDED
THE SERVICE THEN THE TEST MUST BE TO THE END OF THE EXTENSION.
TEST WILL NOT BE COMPLETED WITH LOOPS.
3) VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO
INSTALLATION AT ALL TERMINATING GOVERNMENT LOCATIONS IF A CIRCUIT
EXTENSION IS REQUIRED.
4) VENDOR MUST COORDINATE SITE VISIT WITH LOCATIONS POC 72 HOURS
IN ADVANCE PRIOR TO COORDINATE ACCESS TO FACILITIES.
5) VENDOR MUST CONTACT DISA IMPLEMENTATION ASSISTANCE TO
ESTABLISH THE COORDINATION AND ACTIVATION PROCESS FOR CIRCUIT
TURN-UP AND/OR ANY SITE CONTACT ISSUES.
6) VENDOR INSTALLATION AND MAINTENANCE INSTRUCTION: IAW THE
UNIQUE INSTALLATION FACTORS IN PARAGRAPH 3.
7) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY
CIRCUIT OUTAGES.
8) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.
9) REQUEST ONE-HOUR RESPONSE TIME TURN-AROUND TO REPAIR ONCE
TROUBLE-CALL HAS BEEN REPORTED.
10) THE VENDOR TEST SET/SETS MUST HAVE THE ABILITY TO PRINT OR
ELECTRONICALLY OUTPUT THE TEST RESULTS AND THOSE RESULTS MUST BE
E-MAILED TO THE ACCEPTING AUTHORITY FOR REVIEW.
11) ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED TO DISA
CONUS: (C) 618-418-9950 TOLL FREE: 855-868-9950
12) VENDOR MUST PROVIDE THE LONG HAUL CIRCUIT NO. AND LEC CKT ID
PRIOR TO TURN UP TO THE GOVERNMENT.
13) CIRCUIT OPERATIONS: DEDICATED PATH - 24 HOURS A DAY, SEVEN
DAYS PER WEEK.