APPENDIX A
Existing Dewatering Pumps:
The two dewatering pump motors are vertically mounted Fairbanks-Morse AC induction underdrive motors type QZO. These motors are rated at 75 horse power continuous. 3 phase.
220 / 440 volt. 178A / 89A. Full load 1755 RPM. 24 hour, 50 degree C rise. Frame 2045PV. The two dewatering pumps are Fairbanks-Morse Figure 6972 Deep well pumps with a rated capacity of 3,500 GPM at 60 feet of head and a maximum pump speed of 1,760 RPM. The pumps have an efficiency rating (min.) of 75% at rated operating point.