Attachment 1 - Description of Requirements.pdf
PDF 129 KB Posted
- Attached to
- Carrier Supra S6 with Standby
- Solicitation number
- W50S7K26QA001
About this file
This document is a Description of Requirements for procuring one Carrier Supra S6 truck refrigeration unit. The detailed specifications outline the required features, including a CT33-44 TRI-VORTEX diesel engine, microprocessor control system, automatic start/stop fuel saver, and R-404A refrigerant package. Performance requirements specify refrigeration capacity at various temperatures for both engine-driven and electric standby modes, ranging from 5,000 to 14,250 BTUH across different temperature settings. The procurement includes mandatory documentation (Operator's Manual, Service and Maintenance Manual, and Illustrated Parts Catalog) and requires a minimum 12-month warranty covering all parts.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Combined Synopsis Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Description of Requirements
1.0 Purpose
This document is a request to procure one (1) new Carrier Supra S6 truck refrigeration unit. The unit must meet all standard factory specifications as listed below.
2.0 Item Required
• Quantity: 1
• Model: Carrier Supra S6
3.0 Required Specifications
The unit quoted must include, at a minimum, the following standard features and components:
• CT33-44 TRI-VORTEX DIESEL ENGINE
• 05K12 – 2CYL. COMPRESSOR
• MICROPROCESSOR CONTROL SYSTEM
• IN CAB CONTROLS
• AUTOMATIC START/STOP FUEL SAVER
• SPACE SAVER EVAPORATOR
• AUTOMATIC HOT-GAS HEATING SYSTEM
• R-404A REFRIGERANT PACKAGE
• THREE WAY REFRIGERATION VALVE SYSTEM
• AUTOMATIC DEFROST
• MANUAL DEFROST OVERRIDE
• 65 AMP ALTERNATOR
• DRAIN PAN HEATER
• ELECTRIC FUEL PUMP
• FUEL PICK UP TUBE
4.0 Required Performance Capacity
The unit must meet the following standard performance ratings:
Refrigeration Capacity (Engine Drive):
• At 35°F (1.7°C): 14,250 BTUH
• At 0°F (-17.8°C): 8,500 BTUH
• At -20°F (-28.9°C): 5,000 BTUH
Electric Standby Capacity:
• At 35°F (1.7°C): 12,750 BTUH
• At 0°F (-17.8°C): 7,000 BTUH
• At -20°F (-28.9°C): 4,500 BTUH
5.0 Documentation and Warranty
5.1 Documentation
The following manuals must be provided in English upon delivery:
• Operator's Manual
• Service and Maintenance Manual
• Illustrated Parts Catalog
5.2 Warranty
A minimum 12-month warranty covering all parts is required.
File details come from the government source that posted it. Updated .