This document is a Request for Quotation (RFQ) for a pre-engineered building (PEB) kit to be delivered to Creech Air Force Base in Indian Springs, Nevada. The PEB is required to be 60 feet wide by 100 feet long with a 9-foot eave height, in a "Sandstone" color. The manufacturer must provide the PEB design, including reaction forces for the structural foundation, but not the wall materials or construction, which will be handled by others. The roof must be a standing seam metal in the same color as the PEB. The solicitation is a Total Small Business Set-Aside under NAICS code 332311 with a 750-employee size standard. The anticipated contract type is Firm Fixed Price. Quotes are due on September 24, 2024, and the delivery date is 60 days after award. Award will be made to the lowest-priced, technically acceptable offeror.

View the file

Other files

File Type Posted
Combo Synopsis Solicitation.pdf PDF
Attachment 2 - Statement of Work.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PEB Description

General Description: Design, manufacture and deliver pre-engineered building (PEB) kit with construction documents according to the specifications below. Provide reaction forces at base of PEB columns for structural foundation design by others.

Applicable building codes for design: 2021 IBC, UFC 3-301-01

Job Site Location: Creech Air Force Base, Indian Springs, NV, 89018

PEB Characteristics:

Color: Match Englert Metals "Sandstone"

Width: 60 ft.

Length: 100 ft.

Eave Height: 9 ft.

Building Enclosure type: Partially Enclosed, wall materials are not required as part of this contract. Walls will be designed and built by others.

Roof: Provide standing seam metal roof covering in accordance with roof loads from PEB design, match roof panel color to PEB color (noted above).

Walls: No walls to be provided by manufacturer, walls to be constructed by others

Additional Notes: Account for the additional loads of interior lighting fixtures and interior ceiling fans to be connected to the structure by others.

Building Exposure Category: C

Initial Concept: