Attachment 1 - Breathing Air Compressor Requirement Specifications.pdf

PDF 66 KB Posted

Attached to
Breathing Air Compressor - Combined Synopsis/Solicitation - NFARS Federal contract opportunity
Solicitation number
FA667024Q0010
Issued by
Department of the Air Force Reserve Command

About this file

This document is a combined synopsis/solicitation for a Breathing Air Compressor requirement from the Department of the Air Force Reserve Command. The government is seeking to procure 1 Breathing Air Compressor, Bauer Model Legacy 18-E3 with CO monitor or equivalent, that must be compatible with the existing Air Charge Station at Niagara Falls Air Reserve Station. The compressor must meet minimum specifications including 18 CFM/510L/Min fill speed, 6000 psig, 4-stage, 15 HP motor, CO monitor/sensor, and electric powered. The government will award a single firm-fixed price contract to the lowest priced, technically acceptable offeror. This is a 100% small business set-aside with a NAICS code of 333912 and a size standard of 1,000 employees. Proposals are due by August 30, 2024 at 1:00 PM EDT and the contractor will be responsible for installation on site.

View the file

Other files for this federal contract opportunity

Other files attached to Breathing Air Compressor - Combined Synopsis/Solicitation - NFARS, newest first.
File Type Posted
Attachment 0 - Combined Synopsis-Solicitation - Breathing Air Compressor.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Breathing Air Compressor Requirement Specifications

Quantity 1 - Breathing Air Compressor

Bauer Model Legacy 18-E3 with CO monitor or equivalent

Minimum Specifications:

System MUST be compatible with existing Air Charge Station

Station Model: Scott Safety Revolve Air Charge Station Model #AB110-2300-4

Breathing Air Compressor Air Purification System (CGA Grade E Air)

Compressor Minimum:

Capable of 18 CFM/510L/Min fill speed

6000 psig

4 Stage compressor

15 HP motor minimum

CO Monitor/sensor

Maximum size 50” x 40” x 75”

Electric powered (no gas-powered compressors)

Electrical connection is 3-Phase, 240V, 60 Amp building power

CONTRACTOR TO INSTALL SYSTEM