This document is a pre-solicitation notice for a federal contract opportunity for Boiler Inspections, Post Wide at Fort Campbell, Kentucky. The U.S. Government seeks to procure boiler inspection services on a Total Small Business set-aside. The contractor will provide personnel, materials, and equipment to perform semi-annual or annual inspections on over 300 buildings with boilers. The solicitation number is TBA, with an anticipated closing response date of 15 days following publication. The contract will have a five-year ordering period, with award made to the small business offeror with the lowest price. The applicable NAICS code is 238220 - Plumbing, Heating, and Air-Conditioning Contractors, with a $19M size standard. The contracting agency is the Department of the Army Materiel Command Mission and Installation Contracting Command.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 2 - Performance Work Statement - Boiler Inspections.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Boiler Characteristics/ Summary
- Boiler Inspections will take place in both KY & TN
- More than 300 Buildings possess one (1) or more boilers that require either semi-annual or annual inspections.
- The Boiler Master List with relevant building numbers and inspection information will be distributed to the awardee along with the 1st Task Order.
- Boiler Manufacturers include (note: this list may not be all inclusive):
o AERCO Models: BMK1500, BMK2.0LN o AJAX Models: WG-300 S o Allied Models: AB-3PFBM30-G-15, CFG20B, GRDG20B, 5150-15-5M, AB-3PFBM40-B-30W, FB86-300-JM, NB22517, S15015023 o Bradford White
Model: NTH750NJX3 o Bryan
Model: CLM90-W-GI o Burnham
Models: CL-125-GO-PF, 4FL-92-SPL-C-CP, 4FW-209A-50-G-PF, 4FW-63-45-G-WEB, 4FW-209A-40-G-WEB o CAMUS Models: DRNH-2500-MSI, DMNH-0501-MSI-HL, DMNH-0391-MSI-
LLH
o CENTAURI
Model: 100WBLX125A-IFC o Cleaver Brooks
Models: MTF700-750, MTF700-1000, MTF700-500, MTF700-2000, CFLC-05000, CFCE-2000 o COPPER-FINN Model: CHN065 o CROWN Model: F-4 o ELITE Model: EL150NVWM o FULTON Models: EDR-750, PHW1400, PHW2000, PHW300 o HESCO Model: HNS700 o HTP Model: EL-294-NVWH o HURST Models: S45-G-30-30W, SI-G-SO-15, S4-CP2-100-150, LPE-G-40-
30W, LPW-G-30-30, SERIES 100-30, SERIES 100-40, 51-X-25-30,
51-G-30-30W, 4VT-G-25-30W, S500-150-72M, S45-6-126.3-30W,
C3-G-25B o KEWANEE Models: M-115-G, L3S-100-G, KR6-G-03, VW-35-G, MW-135-G, MW-55-B, MW-55-G, W-55-G, MW-55-6, MW-55-5, 3R107 o LAARS
Models: NTH750NCX3B, PCH100NALNXXN, MT2H100NACK1CXN, M2H1250NAKLCXN, MT2H0400NACK2UN, NTH850NJX3, NTH500NJN2, NTH850NJXS, MT2H1500NACK1CXN o LOCHINAL Model: CNN0662 o LOCHINVAR Models: PBN1002, CBN1256, EBN300, SBN1300, KBN285, KBN501, KBN801, PBN1501, CBN2067, CBN260-M-9, KBN286, AWN400PM, CHN0652, LBN315, CFN0752PM, FN1001, KBN151, CHN0752, KBN211, AWN286PM, CHN1442, KBN400, KBN601, CBNM0747, SBN1500, SBN1000, KBN500, WHN199, KBX400, CBN399, CBN260, KBX-800N, KBX-650N, AWN399PM, AWN801PM o National Model: 7-309 o Parker Models: T600, T970 o PEERLES Models: R62G03, SC/SCT-09-W/S o Precision Model: FPW31L-120PS-W200N o Pure Fire Model: PF210NREV1 o PVI Model: 21WB 250A-PV o Raypak Models: H70850, H71505, H70500 o RBI Models: DB1500, SB350, MB500, Torus WB1500 o Riello Models: AR800, AR399SE o Riverside Models: 1000 WBLX 125A-IFC, 500 WB 130A-CBML o Slant Fin Model: GG350HEC o Triade Model: GPS-9000-SH o Water Tube Model: BFNH 0600 OGI o Weil Mclain Models: SF750, LGB7, EG-45, EG-65-PIDN, CGA-6-PIDN, WCR1-
G-10, CGA-4-PIDN, H-380, 580, EG/PEG-65, CGA-2, LGB2, 80
Series 1-680, 88 Series – 588, PFG-5-PIDN