Attachment 1 - 3 CTS_Handheld Spectum Analyzers Salient Characteristics.docx

DOCX document 20 KB Posted

Attached to
3 CTS HSAs Federal contract opportunity
Solicitation number
FA251725Q0134
Issued by
Department of the Air Force Space Command

About this file

This document is a technical specification for Handheld Spectrum Analyzers (HSAs) for the 3 CTS Electromagnetic Warfare Operators Course (EWOC). The spectrum analyzers must have a frequency range of 5 KHz-2GHz, with precise technical requirements including frequency readout resolution of 0.1 Hz, frequency counter resolution, and specific sweep time and bandwidth capabilities. Key technical specifications include reference frequency drift of 1 x 10^-6, spectral purity at 500 MHz, resolution bandwidths from 1 Hz to 3 MHz, and mandatory features such as spectrogram and band/interval power marker functionality.

The related federal contract opportunity is a combined synopsis/solicitation issued by the 21st Contracting Squadron at Peterson Space Force Base for a brand-specific (Rohde & Schwarz) handheld spectrum analyzer purchase. The solicitation is for a Firm Fixed Price Purchase Order for commercial items, with delivery to Peterson Space Force Base in Colorado. The opportunity is associated with the Department of the Air Force Space Command and uses a streamlined solicitation process that requests quotes directly without issuing a separate written solicitation.

View the file

Other files for this federal contract opportunity

Other files attached to 3 CTS HSAs, newest first.
File Type Posted
RFI 1 FA251725Q0134 3 CTS HSAs.pdf PDF
RFQ FA251725Q0134 3 CTS HSAs.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3 CTS / Electromagnetic Warfare Operators Course (EWOC) Handheld Spectrum Analyzer - Salient Characteristics

1. Frequency Range: 5 KHz-2GHz

2. Reference Frequency Drift/Year: 1 x 10^-6

3. Frequency Readout:

A. Marker Resolution:0.1 Hz
B.Frequency Counter Resolution:0.1 Hz (low), 0.1 MHz (high)
C. Span Uncertainty:1%

4. Spectral Purity: frequency = 500 MHz

5. Sweep Time:Span = O Hz; 56.8 microseconds to 1000 seconds
Uncertainty:Span = 0Hz, 1%; Span >= 10 Hz, 3%

6. Resolution Bandwidths:

Range:-3dB Bandwidths, 1 Hz to 3 Mhz in 1/3 sequence
Selectivity:Gaussian Filter Types; < 5

7. Spectrogram: Must have

8. Band/Interval Power (marker): Must have