Attachment 1 - 3 CTS_Handheld Spectum Analyzers Salient Characteristics.docx
DOCX document 20 KB Posted
- Attached to
- 3 CTS HSAs Federal contract opportunity
- Solicitation number
- FA251725Q0134
About this file
This document is a technical specification for Handheld Spectrum Analyzers (HSAs) for the 3 CTS Electromagnetic Warfare Operators Course (EWOC). The spectrum analyzers must have a frequency range of 5 KHz-2GHz, with precise technical requirements including frequency readout resolution of 0.1 Hz, frequency counter resolution, and specific sweep time and bandwidth capabilities. Key technical specifications include reference frequency drift of 1 x 10^-6, spectral purity at 500 MHz, resolution bandwidths from 1 Hz to 3 MHz, and mandatory features such as spectrogram and band/interval power marker functionality.
The related federal contract opportunity is a combined synopsis/solicitation issued by the 21st Contracting Squadron at Peterson Space Force Base for a brand-specific (Rohde & Schwarz) handheld spectrum analyzer purchase. The solicitation is for a Firm Fixed Price Purchase Order for commercial items, with delivery to Peterson Space Force Base in Colorado. The opportunity is associated with the Department of the Air Force Space Command and uses a streamlined solicitation process that requests quotes directly without issuing a separate written solicitation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFI 1 FA251725Q0134 3 CTS HSAs.pdf | ||
| RFQ FA251725Q0134 3 CTS HSAs.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3 CTS / Electromagnetic Warfare Operators Course (EWOC) Handheld Spectrum Analyzer - Salient Characteristics
1. Frequency Range: 5 KHz-2GHz
2. Reference Frequency Drift/Year: 1 x 10^-6
3. Frequency Readout:
| A. Marker Resolution: | 0.1 Hz | |
| B.Frequency Counter Resolution: | 0.1 Hz (low), 0.1 MHz (high) | |
| C. Span Uncertainty: | 1% |
4. Spectral Purity: frequency = 500 MHz
| 5. Sweep Time: | Span = O Hz; 56.8 microseconds to 1000 seconds |
| Uncertainty: | Span = 0Hz, 1%; Span >= 10 Hz, 3% |
6. Resolution Bandwidths:
| Range: | -3dB Bandwidths, 1 Hz to 3 Mhz in 1/3 sequence | |
| Selectivity: | Gaussian Filter Types; < 5 |
7. Spectrogram: Must have
8. Band/Interval Power (marker): Must have
File details come from the government source that posted it. Updated .