D
C
B
A
D
C
B
A
8 7 6 5 4 3 12
DESIGN ACTIVITY
SIZE CAGE CODE
SCALE UNIT WT.
DRAWN BY DATE(YEAR-MO-DA)
CHECKER ENGINEER
ENGINEER QUALITY ENGINEER
DRAWING APPROVAL
DESIGN APPROVALMATL ENGR MODELED BY
CONTRACT NUMBER
CONTRACTOR
SHEET
DRAWING SIZE D
TOLERANCES ON ANGLES �# �$
2 PLACE DECIMALS �#
3 PLACE DECIMALS �#
FORMAT: D_TACOM_ENG_1_0 12345678
DWG NO.
A
A
B B
9/32
1/16
10 7/64
TO SHARP CORNER
4 63/64
TO SHARP CORNER
9 7/16
1.0
.084 +.020 -.000
45�$
NOTE 3
60�$
.0179
REVISIONS
APPROVEDDATE(YEAR-MO-DA)DESCRIPTIONDRAWING REVMODEL REV
1964-05-065N/A
1967-05-15EO NO.S60220 REDRAWN W/CHANGEAN/A
1982-04-05NOR A1S2028 / 1982-02-16BN/A
1992-03-03M1K2108 / 1991-10-10CN/A
DR1996-03-01
ERR M5K2025 / 1995-07-21
(ECP M5K3011 / 1995-08-04)
DN/A
RLV1997-02-21NOR M6K2070 / 1997-01-07EN/A
BMG2006-02-07
NOR R05K3007 / 2005-07-22
(ECP R05K2031 / 2005-12-13)
F-
BMG2012-07-26NOR R12K2024 / 2012-07-25GG
1 OF 1 1/1
755330319200D
RETAINER, GASKET
US ARMY
FRANKFORD ARSENAL
PHILADELPHIA, PA 19127
2005-10-12M. SELK
2005-10-12V. KHANNA
L. DULISSE
G. FARBANISHJ. WINDHAM
1951-03-20R.L.B.
APPLICATION
USED ONNEXT ASSY
BOX, M2A213032549
BOX, M2A17553298
BOX, PA19
PMIC
MECHANICAL
PROPERTIES
YP
TS
EL2
RA
BH
RH A. ZIOBRO
THIRD ANGLE PROJECTION
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
DO NOT SCALE DRAWING
PART NO. 7553303
THIS DRAWING WAS GENERATED FROM A SOLID MODEL
AND IS CAD MAINTAINED. CHANGES SHALL BE
INCORPORATED BY THE DESIGN ACTIVITY.
NSN NONE
CURRENT DESIGN ACTIVITY CAGE CODE 19200
US ARMY
ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER
PICATINNY ARSENAL, NEW JERSEY 07806-5000
NOTES
1. APPLICABLE STANDARDS/SPECIFICATIONS:
A. ASME Y14.5M-1994
B. MIL-A-2550
2. MATERIAL: COLD ROLLED STEEL PER ASTM-A109 OR ASTM-A568.
3. TO BE DETERMINED AT ASSEMBLY WITH COVER AND GASKET.
4. BEND FLANGES AS SHOWN AFTER PAINTING AND ASSEMBLY WITH GASKET IN COVER.
DISTRIBUTION STATEMENT A.
APPROVED FOR PUBLIC RELEASE:
DISTRIBUTION IS UNLIMITED.
FRACTIONS �# 1/64
0.005
3 0'0"
SECTION A-A
SCALE 4/1
SECTION B-B
SEE DETAIL C
NOTE 4
DETAIL C
4 PLACES
SCALE 4/1
| Sheet 1 |
| Views |
| bottom_1 |
| right_2 |
| bottom_2 |
| new_view_6 |
| right_7 |
| C |