Attachment 03 Support Tube CERTIFIED TEST RESULT FOR PROCUREMENT SSIM.docx

DOCX document 17 KB Posted

Attached to
Support Tubes Federal contract opportunity
Solicitation number
W519TC-23-Q-TUBE
Issued by
Department of the Army Materiel Command Contracting Command Rock Island Arsenal

View the file

Other files for this federal contract opportunity

Other files attached to Support Tubes, newest first.
File Type Posted
Attachment 05 - FAR 52.204-24.docx DOCX document
Attachment 07 - Price Sheet.xlsx XLSX spreadsheet
Attachment 04 - Technical Data Package Information.pdf PDF
Attachment 06- FAR 52.212-3 Alt 1.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CERTIFIED MATERIAL TEST REPORT

For those material(s) identified below, a certified test report must be provided to the Government with each shipment. The test results contained on the certified test report(s) shall be adequate to determine compliance with all applicable requirements of the material specification(s) listed below. Availability of the certified test reports are in addition to other contract requirements and does not reduce or prejudice the Government's right to inspect supplies under other provisions of this contract. The test report(s) shall contain the following:

a. Name and address of suppliers.

b. Purchase order number.

c. Identification of all materials by specification, revision, amendment and dates, together with type, grade, size etc.

d. Quantity of each material.

e. Test results identified by reference to the applicable requirements:

1) Perpendicularity .010 to Datum B

2) True position of the Inner Diameter .97 ± .03

3) Outer Diameter 2.705 ± .010

4) Length 15.62 ± .02

5) ALL requirements of DWG 2114298 D

f. Quantity tested, sample size, and specimen type as applicable.

g. Date, signature, and title of the authorized representative of the contractor that is attesting to the accuracy of test report content.

DWG. No. 7100311 A DWG No. 2114298 D

REQUIREMENT

SPECIFIED FOR (.030 INCH) NOMINAL THICKNESS.

3. FIBERBOARD LINER SHALL BE TIGHTLY AND SPIRALLY WOUND. THE ANGLE OF SPIRAL

SHALL BE 45 ı# 15 DEGREES. LAYERS SHALL BE BONDED TOGETHER WITH POLYVINYL

ACETATE RESIN ADHESIVE IAW COMMERICAL ITEM DESCRIPTION ASTM D4317 OR A-A-1270

BETWEEN LAYERS. HORIZONTAL GAPS BETWEEN WINDINGS SHALL BE 0.06 MAXIMUM.

File details come from the government source that posted it. Updated .