XLWU204016

Appendix - B

23 July 2021

APPENDIX – B

MAPS, DRAWINGS, AND OTHER

PROJECT SPECIFICS

For

REQUEST FOR PROPOSAL

CONSTRUCT B15 & 29

REPLACEMENT/CONSOLIDATION

TYNDALL AFB FLORIDA

FOR PROJECT XLWU204016

Project Site Bldg 15

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

CONSTRUCT B15_B29 GATR REPLACEMENT/CONSOLIDATION

DRAWING NAME

PROJECT # XLWU204016

SHEET 1 OF 4DATE 7/14/2021REV. A

GATR B15 CONSTRUCT NEW SHELTER

SCALE 1: 150

SHEET DESCRIPTION

PSA SKETCH 1

50'

70" 70" 70"

15'15'

KEYNOTES

ALIGN FRONT EDGE OF SHELTER WITH FOUNDATION OF

TOWERS

CENTER SHELTER/PAD BETWEEN TOWERS 4 & 5

TWR 5

TWR 4

TWR 3

TWR 3 TWR 4

TWR 5

BUILDING 15 SHELTER LOCATION

NOTE: ALL DIMENSIONS/MEASUREMENTS ARE APPROXIMATE.

CONTRACTOR SHALL FIELD VERIFY MEASUREMNTS FOR

ALL DRAWINGS (SHEETS 1 TO 4). NEW 40'x20' SHELTER

GENERATOR ROOM

TYPICAL AREA 16'x12'

1014403406C Rectangle

F

E

D

C

B

A

8 7 6 5 4 3 2 1

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

CONSTRUCT B15_B29 GATR REPLACEMENT/CONSOLIDATION

DRAWING NAME

PROJECT # XLWU204016

SHEET 2 OF 4DATE 7/14/2021REV. A

GATR B15 CONSTRUCT NEW SHELTER

SCALE 1: 150

SHEET DESCRIPTION

PSA SKETCH 1

40'‐0"

20'‐0"

4'‐0"

48.00

4'‐0"

18.00

12.00

NEMA

24X24X6

6'‐0"

4'‐6"

NOTES

1. SIXTEEN RADIO/COMMUNICATON RACKS WILL BE

INSTALLED BY OTHERS. (22.5" WIDE, 26“ DEEP, 73” TALL)

2. FORTY TWO ANTENNA CABLES WILL BE ROUTED FROM

THREE ADJACENT TOWERS TO RADIO RACKS VIA

EXTERNAL WAVEGUIDE BRIDGES INSTALLED BY OTHERS.

3. LIGHTING SHOULD BE LOCATED ABOVE AISLES RATHER

THAN ABOVE CABINETS AND RACKS.

KEYNOTES

INSTALL ONE (1) 1‐HOLE 4" CABLE ENTRY PORT ABOVE

CABLE LADDER, PLACE ONE 24"x 24"x 6" NEMA BOX ON

EXTERIOR, ROUTE 4" BURIED CONDUIT TO BUILDING 15.

INSTALL ONE (1) 2‐HOLE 4" CABLE ENTRY PORT ABOVE

CABLE LADDER. INSTALL 18" LENGTH OF 1‐5/8"UNISTRUT

CHANNEL SIX INCHES ABOVE EACH EXTERIOR PORT

INSTALL 12" WIDE CABLE LADDER ABOVE EQUIPMENT

RACKS WITH ACCESS TO CABLE ENTRY PORTS AND FIRE

RATED DEMARCATION BOARD

INSTALL POWER RACEWAY ABOVE RACKS WITH L5‐20

RECEPTICALS FOR EACH RACK (16 TOTAL)

INSTALL 4' X 8' FIRE RATED DEMARCATION BOARD ON

WALL

PROPOSED LOCATIONS FOR TOWER OBSTRUCTION LIGHTS

POWER SAFETY SHUTOFF BOXES, MOUNTED ON EXTERIOR

WALL OF SHELTER (THREE LOCATIONS). EACH WILL

REQUIRE 20 AMP CIRCUIT CONNECTED TO SHELTER MAIN

POWER PANEL

4' x 8' Fire-Rated Demarcation Board

One (1) 2-hole 4" waveguide above

Cable Ladder Above Racks

2 2

26"

4'‐6"

4'‐6"

To UPS power

1 62 3 4 5 7 128 9 10 11 13 1814 15 16 17 19 2420 21 22 23

25 3026 27 28 29 31 3632 33 34 35 37 4238 39 40 41 43 4844 45 46 47

1 62 3 4 5 7 128 9 10 11 13 1814 15 16 17 19 2420 21 22 23

25 3026 27 28 29 31 3632 33 34 35 37 4238 39 40 41 43 4844 45 46 47

Typical Radio/ Communication Racks

FIGURE 2‐1

Power Raceway

22‐½”

73"

12"

Cable Tray

8'‐0"

Rack front

4" BURIED CONDUIT

TO BLD 15 (see Sheet 3 for details)

FPI 1

FPI 2

FPI 3

FPI 4

FPI 5

FPI 6

FPI 7

FPI 8

FPI 9

FPI 10

FPI 11

FPI 12

FPI 13

FPI 14

FPI 15

FPI 16

4 5

SHELTER CABLE LADDER & EXTERIOR PORTS,

RACK OUTLETS AND DEMARC BOARD

Power Junction box mounted on wall of shelter for tower 5

6'‐0"

Power Junction box mounted on wall of shelter for tower 3 and 4

6'‐0"

FIGURE 2‐2

FIGURE 2‐3

FIGURE 2‐4

1‐5/8" UNISTRU

CHANNEL ON EXTERIOR WALL

ONE (1) TWO HOLE

4" CABLE PORT

6"

18"

Outside view of cable entry port

14'‐0"

F

E

D

C

B

A

8 7 6 5 4 3 2 1

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

CONSTRUCT B15_B29 GATR REPLACEMENT/CONSOLIDATION

DRAWING NAME

PROJECT # XLWU204016

SHEET 3 OF 4DATE 7/14/2021REV. A

100'

BUILDING 15

Building 15 Shelter

Cable ladder heightNema Box

Nema Box 4" Cable entry port

Buried 4" conduit between buildings

4" Cable entry port

SHELTER FIBER OPTIC CABLE CONDUIT

FIGURE 3‐1

NOTES

1. SHELTER REQUIRES MININUMN OF 4 STRANDS

OF SINGLE MODE FIBER TO CONNECT TO OTHER

RAWS FACILITIES. EXISTING 12 STRAND FIBER

OPTIC CABLE IN BUILDING 15 HAS 6 AVAILABLE

STRANDS. INSTALLATION OF THIS CONDUIT WILL

ALLOW CONNECTION TO FIBER BACKBONE

KEYNOTES

SHELTER: INSTALL ONE (1) 1‐HOLE 4" CABLE

ENTRY PORT ABOVE CABLE LADDER, PLACE ONE

24"x 24"x 6" NEMA BOX ON EXTERIOR, ROUTE 4"

CONDUIT BURIED TO BUILDING 15.

BUILDING 15: INSTALL ONE 24"x 24"x 6" NEMA

BOX ON EXTERIOR WALL OF BUILDING 15 WITH 4"

CABLE PORT INTO BUILDING 15. HEIGHT OF BOX

SHOULD BE AT INTERIOR CABLE LADDER LEVEL

CONNECT BOTH NEMA BOXES WITH BURIED 4"

CONDUIT (APPROXIMANTLY 100 FEET)

F

E

D

C

B

A

8 7 6 5 4 3 2 1

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

CONSTRUCT B15_B29 GATR REPLACEMENT/CONSOLIDATION

DRAWING NAME

PROJECT # XLWU204016

SHEET 4 OF 4DATE 7/14/2021REV. A

KEYNOTES

2/0 AWG STRANDED BARE COPPER

CONDUCTOR BURIED 18" TO 24" DEEP &

LOCATED 2' TO 4' FROM FOOTING

10' X ¾” CU CLAD STEEL VERTICALLY DRIVEN

GROUND ROD ELECTRODES WITH TOP

DRIVEN TO 12" BELOW GROUND LEVEL

INSTALL TELECOMMUNICATIONS GROUND BAR

(TGB) ON BACKBOARD AND BOND TGB TO EES

USING 1/0 AWG.

ALL CONNECTIONS FOR EES WILL BE LISTED

EXOTHERMIC WELDS OR UL LISTED COMPRESSION

CONNECTIONS

SHELTER EARTH ELECTRODE SUBSYSTEM (EES)

2/0 AWG

2/0 AW

G

2/

AW

G

FLOOR

4'x 8'

TGB

1/0 AWG

CABLE PORT

THROUGH WALL

FIGURE 4‐2

FIGURE 4‐1

Service Entry

NOTES

1. EES SHOULD BE CONNECTED TO ELECTRICAL

SERVICE ENTRANCE FOR SHELTER IAW TIA‐607‐D,

PARAGRAPH 7.5.3

2. THE GROUNDING ELECTRODE SYSTEM FOR

SITES THAT ARE CRITICAL IN NATURE (E.G., PUBLIC

SAFETY FACILITIES, MILITARY INSTALLATIONS,

DATA CENTERS, WEB HOSTING FACILITIES,

CENTRAL OFFICES) SHALL BE DESIGNED TO HAVE

A RESISTANCE OF 10 OHMS OR LESS, PREFERABLY

5 OHMS OR LESS. REF: TIA‐607‐D, PARAGRAPH

8.1.2

RFP APPENDIX - B B15_29_XLWU 20-4016_2021 07 23
RFP APPENDIX - B B15_29_XLWU 20-4016_2021 07 19_
Project Site B15_XLWU204016
Dwgs_Construct GATR B15_B29 Replacement Consolidation_
PSA, Tyndall AFB FL, GATR Anteade XLWY-85-2021-00005_14Jul21 14 DRAFT_
PSA, Tyndall AFB FL, GATR Anteade XLWY-85-2021-00005_14Jul21 15 DRAFT_
PSA, Tyndall AFB FL, GATR Anteade XLWY-85-2021-00005_14Jul21 16 DRAFT
PSA, Tyndall AFB FL, GATR Anteade XLWY-85-2021-00005_14Jul21 17 DRAFT