XLWU204016
Appendix - B
23 July 2021
APPENDIX – B
MAPS, DRAWINGS, AND OTHER
PROJECT SPECIFICS
For
REQUEST FOR PROPOSAL
CONSTRUCT B15 & 29
REPLACEMENT/CONSOLIDATION
TYNDALL AFB FLORIDA
FOR PROJECT XLWU204016
Project Site Bldg 15
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
CONSTRUCT B15_B29 GATR REPLACEMENT/CONSOLIDATION
DRAWING NAME
PROJECT # XLWU204016
SHEET 1 OF 4DATE 7/14/2021REV. A
GATR B15 CONSTRUCT NEW SHELTER
SCALE 1: 150
SHEET DESCRIPTION
PSA SKETCH 1
50'
70" 70" 70"
15'15'
KEYNOTES
ALIGN FRONT EDGE OF SHELTER WITH FOUNDATION OF
TOWERS
CENTER SHELTER/PAD BETWEEN TOWERS 4 & 5
TWR 5
TWR 4
TWR 3
TWR 3 TWR 4
TWR 5
BUILDING 15 SHELTER LOCATION
NOTE: ALL DIMENSIONS/MEASUREMENTS ARE APPROXIMATE.
CONTRACTOR SHALL FIELD VERIFY MEASUREMNTS FOR
ALL DRAWINGS (SHEETS 1 TO 4). NEW 40'x20' SHELTER
GENERATOR ROOM
TYPICAL AREA 16'x12'
1014403406C Rectangle
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
CONSTRUCT B15_B29 GATR REPLACEMENT/CONSOLIDATION
DRAWING NAME
PROJECT # XLWU204016
SHEET 2 OF 4DATE 7/14/2021REV. A
GATR B15 CONSTRUCT NEW SHELTER
SCALE 1: 150
SHEET DESCRIPTION
PSA SKETCH 1
40'‐0"
20'‐0"
4'‐0"
48.00
4'‐0"
18.00
12.00
NEMA
24X24X6
6'‐0"
4'‐6"
NOTES
1. SIXTEEN RADIO/COMMUNICATON RACKS WILL BE
INSTALLED BY OTHERS. (22.5" WIDE, 26“ DEEP, 73” TALL)
2. FORTY TWO ANTENNA CABLES WILL BE ROUTED FROM
THREE ADJACENT TOWERS TO RADIO RACKS VIA
EXTERNAL WAVEGUIDE BRIDGES INSTALLED BY OTHERS.
3. LIGHTING SHOULD BE LOCATED ABOVE AISLES RATHER
THAN ABOVE CABINETS AND RACKS.
KEYNOTES
INSTALL ONE (1) 1‐HOLE 4" CABLE ENTRY PORT ABOVE
CABLE LADDER, PLACE ONE 24"x 24"x 6" NEMA BOX ON
EXTERIOR, ROUTE 4" BURIED CONDUIT TO BUILDING 15.
INSTALL ONE (1) 2‐HOLE 4" CABLE ENTRY PORT ABOVE
CABLE LADDER. INSTALL 18" LENGTH OF 1‐5/8"UNISTRUT
CHANNEL SIX INCHES ABOVE EACH EXTERIOR PORT
INSTALL 12" WIDE CABLE LADDER ABOVE EQUIPMENT
RACKS WITH ACCESS TO CABLE ENTRY PORTS AND FIRE
RATED DEMARCATION BOARD
INSTALL POWER RACEWAY ABOVE RACKS WITH L5‐20
RECEPTICALS FOR EACH RACK (16 TOTAL)
INSTALL 4' X 8' FIRE RATED DEMARCATION BOARD ON
WALL
PROPOSED LOCATIONS FOR TOWER OBSTRUCTION LIGHTS
POWER SAFETY SHUTOFF BOXES, MOUNTED ON EXTERIOR
WALL OF SHELTER (THREE LOCATIONS). EACH WILL
REQUIRE 20 AMP CIRCUIT CONNECTED TO SHELTER MAIN
POWER PANEL
4' x 8' Fire-Rated Demarcation Board
One (1) 2-hole 4" waveguide above
Cable Ladder Above Racks
2 2
26"
4'‐6"
4'‐6"
To UPS power
1 62 3 4 5 7 128 9 10 11 13 1814 15 16 17 19 2420 21 22 23
25 3026 27 28 29 31 3632 33 34 35 37 4238 39 40 41 43 4844 45 46 47
1 62 3 4 5 7 128 9 10 11 13 1814 15 16 17 19 2420 21 22 23
25 3026 27 28 29 31 3632 33 34 35 37 4238 39 40 41 43 4844 45 46 47
Typical Radio/ Communication Racks
FIGURE 2‐1
Power Raceway
22‐½”
73"
12"
Cable Tray
8'‐0"
Rack front
4" BURIED CONDUIT
TO BLD 15 (see Sheet 3 for details)
FPI 1
FPI 2
FPI 3
FPI 4
FPI 5
FPI 6
FPI 7
FPI 8
FPI 9
FPI 10
FPI 11
FPI 12
FPI 13
FPI 14
FPI 15
FPI 16
4 5
SHELTER CABLE LADDER & EXTERIOR PORTS,
RACK OUTLETS AND DEMARC BOARD
Power Junction box mounted on wall of shelter for tower 5
6'‐0"
Power Junction box mounted on wall of shelter for tower 3 and 4
6'‐0"
FIGURE 2‐2
FIGURE 2‐3
FIGURE 2‐4
1‐5/8" UNISTRU
CHANNEL ON EXTERIOR WALL
ONE (1) TWO HOLE
4" CABLE PORT
6"
18"
Outside view of cable entry port
14'‐0"
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
CONSTRUCT B15_B29 GATR REPLACEMENT/CONSOLIDATION
DRAWING NAME
PROJECT # XLWU204016
SHEET 3 OF 4DATE 7/14/2021REV. A
100'
BUILDING 15
Building 15 Shelter
Cable ladder heightNema Box
Nema Box 4" Cable entry port
Buried 4" conduit between buildings
4" Cable entry port
SHELTER FIBER OPTIC CABLE CONDUIT
FIGURE 3‐1
NOTES
1. SHELTER REQUIRES MININUMN OF 4 STRANDS
OF SINGLE MODE FIBER TO CONNECT TO OTHER
RAWS FACILITIES. EXISTING 12 STRAND FIBER
OPTIC CABLE IN BUILDING 15 HAS 6 AVAILABLE
STRANDS. INSTALLATION OF THIS CONDUIT WILL
ALLOW CONNECTION TO FIBER BACKBONE
KEYNOTES
SHELTER: INSTALL ONE (1) 1‐HOLE 4" CABLE
ENTRY PORT ABOVE CABLE LADDER, PLACE ONE
24"x 24"x 6" NEMA BOX ON EXTERIOR, ROUTE 4"
CONDUIT BURIED TO BUILDING 15.
BUILDING 15: INSTALL ONE 24"x 24"x 6" NEMA
BOX ON EXTERIOR WALL OF BUILDING 15 WITH 4"
CABLE PORT INTO BUILDING 15. HEIGHT OF BOX
SHOULD BE AT INTERIOR CABLE LADDER LEVEL
CONNECT BOTH NEMA BOXES WITH BURIED 4"
CONDUIT (APPROXIMANTLY 100 FEET)
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
CONSTRUCT B15_B29 GATR REPLACEMENT/CONSOLIDATION
DRAWING NAME
PROJECT # XLWU204016
SHEET 4 OF 4DATE 7/14/2021REV. A
KEYNOTES
2/0 AWG STRANDED BARE COPPER
CONDUCTOR BURIED 18" TO 24" DEEP &
LOCATED 2' TO 4' FROM FOOTING
10' X ¾” CU CLAD STEEL VERTICALLY DRIVEN
GROUND ROD ELECTRODES WITH TOP
DRIVEN TO 12" BELOW GROUND LEVEL
INSTALL TELECOMMUNICATIONS GROUND BAR
(TGB) ON BACKBOARD AND BOND TGB TO EES
USING 1/0 AWG.
ALL CONNECTIONS FOR EES WILL BE LISTED
EXOTHERMIC WELDS OR UL LISTED COMPRESSION
CONNECTIONS
SHELTER EARTH ELECTRODE SUBSYSTEM (EES)
2/0 AWG
2/0 AW
G
2/
AW
G
FLOOR
4'x 8'
TGB
1/0 AWG
CABLE PORT
THROUGH WALL
FIGURE 4‐2
FIGURE 4‐1
Service Entry
NOTES
1. EES SHOULD BE CONNECTED TO ELECTRICAL
SERVICE ENTRANCE FOR SHELTER IAW TIA‐607‐D,
PARAGRAPH 7.5.3
2. THE GROUNDING ELECTRODE SYSTEM FOR
SITES THAT ARE CRITICAL IN NATURE (E.G., PUBLIC
SAFETY FACILITIES, MILITARY INSTALLATIONS,
DATA CENTERS, WEB HOSTING FACILITIES,
CENTRAL OFFICES) SHALL BE DESIGNED TO HAVE
A RESISTANCE OF 10 OHMS OR LESS, PREFERABLY
5 OHMS OR LESS. REF: TIA‐607‐D, PARAGRAPH
8.1.2
| RFP APPENDIX - B B15_29_XLWU 20-4016_2021 07 23 |
| RFP APPENDIX - B B15_29_XLWU 20-4016_2021 07 19_ |
| Project Site B15_XLWU204016 |
| Dwgs_Construct GATR B15_B29 Replacement Consolidation_ |
| PSA, Tyndall AFB FL, GATR Anteade XLWY-85-2021-00005_14Jul21 14 DRAFT_ |
| PSA, Tyndall AFB FL, GATR Anteade XLWY-85-2021-00005_14Jul21 15 DRAFT_ |
| PSA, Tyndall AFB FL, GATR Anteade XLWY-85-2021-00005_14Jul21 16 DRAFT |
| PSA, Tyndall AFB FL, GATR Anteade XLWY-85-2021-00005_14Jul21 17 DRAFT |