PERFORMANCE WORK STATEMENT (PWS)
HAZARDOUS WASTE DISPOSAL
SCOPE:
The Geotechnical and Structures Laboratory (GSL) of the U.S. Army Engineer Research and Development Center (ERDC) at Waterways Experiment Station requires the removal of hazardous waste materials and disposal of other containerized/packaged chemicals/materials over the next five years.
To meet this need, ERDC GSL anticipates award of Blanket Purchase Agreements (BPA). The total anticipated need over the next five years is $150,000.
The Contractor shall furnish all labor, materials, equipment, and transportation necessary for the cleanup/disposal of all materials specified in each BPA call. Maximum amount of effort per call will be $30,000.00.
REQUIREMENTS:
The contractor will be required to perform the following upon request of the government:
- Lab spill cleanup and waste disposal to remove and properly dispose of chemical spill in laboratory.
- Removal of containerized/packaged materials.
- Providing lab packs to meet transportation standards, if needed
- Testing of unknown wastes
Site visits may be needed prior to issuance of a BPA call so the contractor can review the materials to be removed and consult with Government representatives concerning the effort.
PERIOD OF PERFORMANCE:
Master BPA: Five years from date of award.
BPA Call: Contractor will begin within 30 days of BPA call and will complete within 15 days unless otherwise specified.
PLACE OF PERFORMANCE:
All materials will be collected at:
Engineer Research and Development Center 3909 Halls Ferry Road Vicksburg MS, 39180
Specific buildings will be specified in each BPA Call.
Table 1 provides a list of potential materials (but is not limited to) that require proper disposal.
The same and/or similar materials are anticipated to require removal over the next five years.
Table 1. List of Potential Chemicals/Materials
Name
20 % acetone, 30 % toluene, 15 % hexane, 10 % methanol, 15 % ethanol, 5% dimethylformamide, 4% mcresol 1 % carbonnanotubes
3775E Reference fuel-B 60 % water, 15 ethanol 15 ethylene glycol butyl ether 10 perchloric acid
80 % isopropanol 20 % water 85 % water, 15 % potassium permangante 89 % mcresol 10 % nylon 6 polymer, 1 % graphene
90 % water 10 % methyl orange 92 % water, 2 % clay (kaolinite bentonite), 2 % monomer (acrylamide, acrylic acid, 2-dimethyl amino methacrylate), 1 % iron particles (Fe3o4), 1 % ethanol, 1 % methanol, 1 % polyvinyl alcohol, 1 % carbon nanotubes
96 % dichloromethane, 1 % JP8, 1 % FR282, 1 % Royco 555, 1 % Rocyco 889
Acetone Acetone Adva 190 ADVA Flex A-Heptane Ammonium Nitrate ART HybridComp. Grout Part A Bioact AE Butane Calcium Chloride Carbon Disulfide Cellufoam WF-304 Cembinder N8 Chryso 150 Conblock SH ConSeal CS-90 Part A Cryotech CF7 liquid deicer CS-90 Part B Daraval Darex DE Neef NS-200
Diesel Dispal 10F4-32 Dispersion DOW Corning 200 fluid Dow Corning 550 fluid
EP Addagrip 1000 Part B Ethylene Glycol EUCO DiamondHard EUCON Stasis Gasoline Glenium 7500 Glenium 7500 Grace Recover Halotron R2
JP8, FR282 Royco 555, Rocyco 889 Kasil 6 KBP P-Seal Kikatard 44 Klean Strip Lenium RV Lube Oil Massterlife CRA Master Air AE 200 Masterbuilder 700 N Masterlife SRA 20 MasterMatrix 33 MasterMatrix UW 450 MasterMatrix VMA 202 MasterPolyheed 997 Max Blue Tabs m-cresol
MEARL Geofoam mercury thermometers Methanol Mobil DTE Oil Extra Heavy Mobil DTE Oil Heavy Medium Mobil Synthetic Oven Lub Nimexol Nitric Acid Organic Peroxide Type F
OSHA Hydrolic Fluid
Polecrete Stabilizer Polyspec 100 EX Polyspec RezRock Pozzolith 9000 Premier AquaMag FM Rando HD 32 Rando HD ISO 100 Rejuva Seal Russtech Superflo 2040 Sia Viscoflow 2020 Sika Visocrete 4100 Sika Viscocrete 2100 Sika Visocrete Sikament 100 SC Thiokol FEC 2233 TK 20 Tri Siloxane
TK 2110 A
TK 592
TK Trisil TK-590
TK-2110 A
TK-2415 A HMWMA
Toulene Unknown WR Grace Concrete Admixture used oil
WALOCEL MKX 60000
Water Flush
| SCOPE: |
| REQUIREMENTS: |