Performance Requirements Mid-Size Electroshocking Boat
BOAT:
• 16’ LOA
• 60” Bottom (Flat)
• 24” Side Height
• 3/16” gauge aluminum bottom
• 0.160 gauge aluminum sides
• 4-angle runners on bottom
• 36” Front deck with dry storage in front deck bulkhead
• 0.125” gauge aluminum false floor slick plated
• Center console
• Handrails
• 4-Drains in front deck
• Bed liner (All inside area sprayed including the outside of live well, center console, handrails)
RIGGING ITEMS:
• Navigation Lights
• Driver swivel seat behind console (Pedestal type)
• 2-Fuel Tank 6-gallons plastic
• 1/1-Battery/case
• 1-Battery Selector switch
• Bilge pump 1100
• Electric control panel, heat shrink wiring
• 1-12 Volt receptacle
• 1-Fuel filter
• Hydraulic steering single Teleflex
• Stainless steel steering wheel
• 2-3” Drain plugs
• Hydraulic Jack plate
• 2-Aluminum perforated metal baskets 3/16” gauge
LIVE WELL SPECIFICATIONS:
• 56” length, 19” width, 19” depth
• Lid has three separate doors
• 1-3” Drain plug
• Live well will have padded seats on each lid
GENERATOR:
• Honda EU7000is Bi-Fuel
MOTOR:
• 60HP Yamaha, 20” shaft, top mount control, key switch, tach gauge, wiring harness, stainless steel propeller
TRAILER:
• Aluminum, CAP #3,500 lbs. jack, side boards, 4-bunks, spare tire with mount
ELECTROFISHING EQUIPMENT:
• Shocking Unit Removable
• Infinity HC-80 Electrofishing Control Box o DC output power, square wave, 5500 watts continuous, 24000t watt pulsed, output varies by duty cycle o DC output voltage 0-600 VDC at 80 A peak o AC output power up to 7200 watts, continuous pulsed and pulse packets o AC output voltage 0-240 VAC at 30 A RMS o Pulse Rate adjustment from 1-300 pulses per second (in 1 pps increments) o Duty Cycle adjustment from 1-100% (in 1% increments) o Voltage adjustment in 1 volt increments o May be used in conductivities from 40-2300 uS, with duty cycle set at 20-25% and a fully configured electrofishing boat, use in higher conductivities if reduce duty cycle and anode surface area o Field proven modern electrofishing technology, automatic voltage range shifting for two ranges of voltage, high voltage soft start electronic protection, software protection for internal circuitry and overloading, dead short protection, ability to set a voltage ceiling, digital (live) displays in single illuminated alpha information screen to notify user of overloading errors, incorrect settings, and dead shorts o Independent digital metering (three LDC displays) for peak watts, amps, and volt o Monitors input frequency and voltage form source generator o Auto-correction of frequency and voltage to ensure consistent output waveforms o Isolated high voltage output from safety switch circuit o Integrated safety switch continuity test function o Nine programmable electrofishing settings, able to set and recall waveform (AC or DC) duty cycle, pulse rate, and volts o Resettable fishing time o Red illuminated emergency shut-down switch for operator o Angled control panel display with low profile fingertip push/selector button controls o Red illuminated displays (Watts, amps, and volts) for night time electrofishing o Hermetically sealed/splash resistant design o Cooling via convection by oversized aluminum rear heat sink
(12.75”Lx5.25”Hx1.6725”D) no mechanical fans o Three waterproof input, output, and switch connections below heatsink at rear of control box o Water resistant main breaker (electric hydraulic) o High voltage 25A externally accessible fuses (water tight) for easy troubleshooting o External hardware gasketed and 0-ringed for splash resistance o System incorporated with nickel metal hydride battery, data recall when unit is powered down o 16”X12”X11” compact design, powdered coated gray 5052 H32 aluminum 0.090”, 31.5lbs. lightweight chassis o Unit does not contain any superfluous features (i.e. animated screen) that may distract the operator o Powered by commercially available 240V 60Hz generators (must have an isolated neutral) including Honda EU7000iS inverter generator (coupled with the Inverter
Generator Stabilizer module) o Unit may be used across various electrofishing platforms (i.e. stream barges, canoes, jon boats, rafts, etc.)
• Protective transport case for Infinity Series Control Boxes
• Two hand held anode prod poles 1-10ft long; 1-12ft long o 12” stainless steel anode rings. No switch o Crafted from non-conductive reinforced fiberglass protruded tubing, nominal O.D. of 1” and 0.125” wall o 20’ of heavy-duty, waterproof/oil resistance electrical cable; protective loom o Waterproof anode connector, tether and extended strain relief o Connect directly to anode/cathode junction box
• 2-5”X7.5” heavy duty foot pedal safety switch for driver o cast aluminum construction, low profile to minimize fatigue, rated for use in wet environments; gasketed, fitted with strain relief, 15ft cord and switch connector to HC-80 control box
• Anode/Cathode junction box o Provided output connection to boom/poles (anode) and boat (Cathode), 10 ga wiring, UV/water resistant 15ft output cord, output connector and sealing cap, connects directly to the HC-80 control box, sealing caps for anode connections, Cathode wire, lug, and hardware for bonding to boat hull (cathode), plug and go style junction box system that may be placed on any platform (i.e. boat, raft, etc)
• Inverter Generator Stabilizer (IGS) module and hanger o Stabilizes output from Eu7000is inverter generator unit to HC-80 control box, hanger attaches to generator frame for convenient mounting and cord routing, 10ft of 10/3 cord, input connector to Infinity Box and twist lock generator plug connects to the control box and generator