Attachment 002 - Matrix.pdf

PDF 104 KB Posted

Attached to
Pathogen Screening Technology Federal contract opportunity
Solicitation number
123A9424Q0002
Issued by
Department of Agriculture Food Safety and Inspection Service

About this file

This document contains evaluation criteria for a pathogen screening technology solicitation from the Department of Agriculture Food Safety and Inspection Service. The criteria include technical requirements for the screening technology such as accurately detecting Salmonella, Listeria monocytogenes, Campylobacter, and Listeria species from samples. The technology must meet limits for detection, accuracy, predictive values, strain panels, and throughput. Additional requirements include compatibility with Windows 10, small benchtop footprint, power needs, and reporting capabilities. Non-technical considerations include information technology compliance and a published third-party validation.

View the file

Other files for this federal contract opportunity

Other files attached to Pathogen Screening Technology, newest first.
File Type Posted
24Q0002 Revised.pdf PDF
Attachment 003.pdf PDF
QandAs.pdf PDF
Attachment 001 - PWS.pdf PDF
24Q0002.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A B C D E Technical Criteria

Uses an enriched sample and isolated colony as prescribed in MLG Chapters 4, 8, and 41 Pass/fail Provide detection of Salmonella species Pass/fail Provide detection of Listeria monocytogenes Pass/fail Provide detection of Campylobacter species Pass/fail Achieve 90% accuracy of detection of target organisms Pass/fail Achieve 90% accuracy of detection of non-target organisms Pass/fail Accuracy, compared to cultural method, 90% or higher Pass/fail Positive predictive value, 90% or higher Pass/fail Negative predictive value, 90% or higher Pass/fail Results for a complete panel of strains for inclusivity and exclusivity Pass/fail

Minimum limit of detection (LOD) of 104 colonies Pass/fail Provide detectin of Listeria species Pass/fail Method will have a published validation by an internationally recognized, third-party standards organization Pass/fail Capable of creating .csv or compatible files for importing and exporting data and templates Pass/fail Provides a run report with positive and negative results Pass/fail Analyze at least 96 tests on a single instrument (minimum) Pass/fail Information Technology components will meet current Government requirements and be compatible with Windows 10 Pass/fail Require a laboratory bvenchtop footprint of less than 10 linear square feet for instrument, hardware, PC and additional components Pass/fail

Operate within manufacturer's operational specifications within the existing environments of the three FSIS laboratories, including maximum power requirements of 120 Volts, 10 Amps AC Pass/fail

Appendix - Criteria for Vendor Performance Criteria