This combined synopsis and solicitation requests quotations for a liquid chromatography-mass spectrometry analyzer kit and associated equipment, software, and supplies to be delivered to the Corporal Michael J. Crescenz VA Medical Center in Philadelphia, Pennsylvania. The Department of Veterans Affairs seeks to procure 18 contract line items including a SCIEX QTRAP 4500MD mass spectrometer, nitrogen generator, autosampler, chromatography columns, chemical and calibration standards, workstation, software licenses and Microsoft Office under solicitation number 36C24420Q1066. Interested offerors must provide fixed-price quotes by September 29, 2020 to be considered for award. Any contract resulting from this solicitation will require registration in the System for Award Management database.

View the file

Other files

File Type Posted
36C24420Q1066_1.docx DOCX document
Attachment 002 Price Cost.docx DOCX document
Attachment 003 Redacted BNO SSJ JandA.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK (SOW) FOR

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LCMS/MS) ANALYZER AT

VA PHILADELPHIA VA MEDICAL CENTER

3900 WOODLAND AVENUE

PHILADELPHIA, PA

19104-4551

1. Contract Title.

Procurement of a Liquid Chromatography-Mass Spectrometry (LCMS/MS) Analyzer and all associated equipment, computers, Monitor, training. License, software, gas generator, accessories, and initial chemicals needed to perform Drug confirmation testing using LCMS/MS at the Michael J. Crescenz VA Medical Center.

2. Background.

Pathology and Laboratory Medicine, Chemistry and Toxicology section needs new equipment that can analyzer patient’s urine to detect and confirm drugs detected initially on a drug screen or drugs being prescribed to veteran patients to confirm the presence in random urine. This equipment will replace a 15-year-old instrument which is being used until a replacement is acquired. It is beyond the life expectancy of the analyzer. We are looking for a replacement that have minimal maintenance, prevents source contamination, possesses increased sensitivity, and significantly decreases in-source carryover to be able to detect and confirm the presence of drug analytes in human urine.

3. Requirements. PVAMC requires an LCMS/MS QTRAP System that has the following:

3.1 TurboV Ion Source: a unique heater geometry that places the desolvation heaters (x2) orthogonal to the ESI electrode. This configuration focuses heat on the ESI droplets for efficient desolvation just above the axis of the orifice which results in superior sensitivity and significantly decreases in-source carryover.

3.2 Curtain Gas interface design to consist of a neutral gas (N2) that flows out from between the curtain plate and the orifice. This orifice must be a single thin aperture separating the vacuum chamber from atmosphere. This design is different that the other interface designs that utilize a long metal tube to transfer ions from the atmosphere into the vacuum region of the MS. This design prevents neutral and other ion clusters from entering the mass analyzer and has advantages over the ion transfer tube designs that are prone to clogging.

3.3 QJET is needed to capture the ions in the free jet expansion cloud behind the orifice and to transfer them to the lower pressure regions of the mass spectrometer (Q0, Q1, Q2, Q3). The QJet Ion Guide is an RF only quadrupole that focuses the ions into the lower pressure Q0 region while efficiently removing gas molecules. The QJET coupled with the curtain gas and orifice design gives a rugged and robust advantage.

3.4 QTRAP: which is a hybrid triple quadrupole/linear ion trap mass spectrometer that can accommodate both Quantitative and qualitative LC-MS/MS workflows. QTRAP gives one the ability to use both the triple quad and ion trap scan functions on the same platform even with a single LC-MS/MS injection. In addition to MRM quant, the QTRAP system can be used to rapidly acquire MS/NS spectra for every detected peak (by MRM) that exceeds a threshold. Library searching of MS/MS spectra then allows the inambiguous identification of chromatographic peaks.

3.4.1 QTRAP 4500MD

3.4.2 Turbulon spray probe

3.4.3 APCI Pobe

3.4.4 Cliquid MD V3.2.1 Full Software kit

3.4.5 MultiQuant MD 3.0.1 Software kit

3.4.6 Data Acquistion and Processing Computer

3.4.7 Dell Monitor

3.4.8 Edgeport USB to Serial Expansion Kit

3.4.9 Clinical LCMS system

3.4.10 PPGs Chemical Standard Kit

3.4.11 Triazine Standard Mixture

3.4.12 FG, SYNERGI 4U Fusion RP80A 50X2

3.4.13 Peak Genius 1024 nitrogen generator

3.4.14 Peak Dual Tap transformer 200-230 VAC

3.4.15 Configured EXIONLC AC System

3.4.16 Exion LC Column Oven- 120V

3.4.17 Sample rack for DWP, SIL-20A/AC

3.4.18 MS Office 2016 Professional PLUS ISV GLOBAL Kit

3.4.19 MS Bench SCI 1

3.4.20 48WX36DX33H Work bench

3.4.21 Success Master MD x 3

3.4.22 MultiQuant 3.0 License- LIM Compatibility drive Raid 1, 8X DVD +/- RW Slimline, cyber image of Windows 10 Io T enterprise 2019 LTSC 64 bit, dell optical mouse, dell multimedia keyboard

3.4.24 Monitor 27 inch

3.4.25 Triazine Standard mixture

4. Specific Tasks.

4.1 Drug confirmation analysis must be able to be performed utilizing the LCMSMS platform to include all items needed to be a functional Drug detection analyzer to include all software to include MS office 2016, all licenses needed, nitrogen generator, Training for 3 years, workbench to hold the equipment, separate computer to analyze the data while still being able to operate the LCMSMS without slowing down the processing of the samples

5. Warranty. Unit should come with 2-year warranty on parts and labor

6. VA Handbook 6500.3, Certification and Accreditation (C&A). The C&A requirements do not apply and Security Accreditation Package is not required.