02/13/2020
M701PRID 145CS114-2Part Number
1680-01-120-7641NSN CH-47FSystem
ELECTRO-MECHANICAL ACTUATORNomenclature
YAdequate DMWR Available?
DMWR-55-1680-289DMWR ID
07/19/2013DMWR Date
DMWR Chg #
NPre-Award Survey Recommended?
NCorrelation Performance Study Required ? NPVA Recommended?
Proper orientation of the lower rod end (Item 24, Figure 3-1), part of assembly (21, Figure 3-1), is a critical characteristic. The lower rod end has a flat side and a tabbed side (anti-rotation lugs). The rod end shall be installed with the flat side facing the motor side of the actuator (tabs facing away from the motor). Refer to table 2-2 of DMWR for CSI CC.
See DMWR 55-1680-289 paragraph 3-7 and Table 3-1.2 for Inspection Requirements.
See DMWR 55-1680-289 paragraph 4-1 for Final Test Procedures.
See DMWR 55-1680-289 paragraph 5-7 for In-Process and Acceptance Inspection Requirements.
The overhaul facility is responsible for acquisition, maintenance, calibration, and disposition of all Test, Measurement and Diagnostic Equipment (TMDE). TMDE shall be maintained and controlled in accordance with MIL-I-45607, AMCOM-R-702-2 or NCSL Z540.3. Calibration documents for all TMDE shall be traceable to the National Institute of Standards of Technology (NIST).
Identify Any Special Processes, Test Procedures, and/or Instructions
YCritical Safety Item?
There are no emerging airworthiness issues, no issues related to ECPs affecting the CSI status, and no concerns over reliability/durability for the CH-47F Electro-Mechanical Actuator at the time of this review.
Special Airworthiness Considerations
FCDD-AMA-M AED Sustainment has verified the CSI/NST status through the ARISE CIM on 14 Nov 2019 and the NHA is CSI and NST. The subcomponents are CSI and NST. Engineering testing Fatigue, Endurance, and Interchange are not required for overhaul. Updated NHA table in ARISE CIM. The manufacturer part number is 541604-9-1. DEM
Other Requirements / Comments
If the item is not a CSI and no adequate DMWR is available, approved sources, if any, are listed by CAGE as follows:
NSpecial Post-Contract Award Requirements?
The Prime or OEM is required to submit a Frozen Plan 30 days after contract award to Engineering Directorate (ED) and Aviation Engineering Directorate (AED). The Frozen Plan will be reviewed and require approval by ED and AED prior to government acceptance of contract deliverable assets.
Other Requirements / Comments (Part II)
The applicable DMWR contains detailed procedures regarding IUID requirements for this component. These procedures can be found in MEOs D2454, D2455, and D2456.
Other Requirements / Comments (Part III)
SRD-AMA-M-A/W-Sustainment has re-verified the CSI/NST status through the ARISE CIM on 3 Feb 2020 and the NHA is CSI and NST. The subcomponents are CSI and NST. Engineering testing Fatigue, Endurance, and Interchange are not required for overhaul. No changes made. DEM
Other Requirements / Comments (Part IV)
YDoes QE-STD-2 Apply?
Y
Additional CSI Requirements
CSI Contains CSI Replacement Parts? YEngineering Testing Required?
The Contractor shall flow down the Critical Characteristics and QE-STD-1 to all Suppliers of CSIs.
The solicitation/RFP shall require that all proposals/responses include a special tooling and test equipment section that addresses the contractor's plan to meet all government special tooling and test equipment requirements with either:
1. Physical possession of the required tools, 2. Confirmed requisitions for the required tools, 3. Confirmed arrangements for subcontracting the processes requiring the special tools, or 4. Specific plans describing their technical approach to develop equivalent tools.
RStatus
YTDPL?
01/01/1987Approved Date
M&O AED REQUIREMENTS DATA
Commerciality Determination
Commercial Item? N NBest Commercial Practice Acceptable?
02/13/2020
M701PRID 145CS114-2Part Number
1680-01-120-7641NSN CH-47FSystem
D1116
D1733
D2176
D2299
D2421
D2454
D2455
D2456
D2488
D2489
D2490
D2508
D2528
D2564
D2567
D2568
D2575
See DMWR 55-1680-289 Table 2-1 and Table 2-1.1 for test and special tools and equipment.
Critical Tools and Test and Inspection Equipment Requiring AED Approval for Substitutes
MEOs Required for Competitive Contract?
Special Post-Contract Award Requirements
Other Requirements / Comments (Part V)
RStatus
Correlation Performance Study Requirements
File details come from the government source that posted it. Updated .