Attachment 0001 Concrete Mtg Pads and Caps.pdf
PDF 1 MB Posted
- Solicitation number
- W519TC24R2042
About this file
This document is a set of drawings and specifications for concrete mounting pads and caps to be installed at the Rock Island Arsenal as part of a federal contract opportunity.
The key details are:
- The contract requires the installation of concrete mounting pads, utility trench caps, and a blast machine pit at various locations throughout the Rock Island Arsenal facility.
- The drawings provide the specifications for the concrete work, including material requirements, dimensional details, and construction methods.
- The accompanying federal contract opportunity is Solicitation Number W519TC24R2042, titled "Concrete Fill/Cap Utility Trench and Concrete Blast Equipment Pit", issued by the Department of the Army Materiel Command Contracting Command Rock Island Arsenal.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 24R2042 Amendment U00002.pdf | ||
| 24R2042 Released Sol.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL LOCATIONS
CONCRETE MOUNTING PADS AND CAPS
PLANT ENGINEERING
ROCK ISLAND ARSENAL JMTC
11-FEB-24
DRAWN
SCALE DATE
APPROVED
NO.
DRAWING
TARA-LGC
PLANT ENGINEERING DIVISION
ROCK ISLAND ARSENAL
CONCRETE MOUNTING PADS AND CAPS
SHEET 1 OF 10B. McCLURE B. NILES
NONE
BLAST MACHINE PIT CAP
UTILITY TRENCH CAP
DOUBLE COLUMN #1 AND #2
CONTRACTOR SECURITY NOTES
GENERAL NOTES
GENERAL LOCATIONS
INDEX
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
X
X
X
X
X
X
X
X X
X
X X
X
X
X
X
M I S S
I P P
I R
I V E R
LOCATIONS ON ROCK ISLAND ARSENAL
X
X
X
X
X
X
X X
X X
X
X X
X
X X X X X X X X X X X
X X
X
X
X
X X X
X
X
X
X
X X
X
X
X
X
X
X X
X
X X
X
X
21 29
30-G
70-G
2-G 3-G
4-G
6-G
50 52
62 64
102 104
157120144
301-G
314 312
220210
332333
204203
R O
C K
IS
L
A N
D
U .S . G
O V
E R
N M
E N
T
B R I D
G E
PARKING
RODMAN
D A V E N P
O R T
G
IL
L E
S P
IE
KINGSBURY
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
TERRACE
PARKING PARKING PARKING
HEDGE
LANE
SOUTH AVENUE
NORTHAVENUE
PARKING
PARKING
PARKING
PARKING
E A
S T
RODMAN
DRIVE
BECK
SYLVAN
AV
EN
U E
KING
DRIVE
SHED
B L U
N T
R O
A D
PROSPECT
DRIV
E
D R
IV
E
C E
M E T E R
Y
D R
IV
E
DYKE
ROAD
R O
D M
AN
BLUNT
PARKING
PARKING
PARKING
PARKING
PARKING
79 83
S Y
V N
R
IV
E
AVE
BAUMBECK AVENUE
216212
LO
C
K
AND
DAM
NO
. 1
BETTENDORF
DAVENPORT
MOLINE
ROCK ISLAND
C A N A L
M
O
L
I N
E
S L O U G H
E. RIVER DR. GRANT ST.
2ND ST.
4TH ST.
3RD ST.
STATE ST.
PC
X
XX
X
X
X
X
X
X X
X
X X
X
X X
X X
X
X
X
X
X
X X
X
RIA-34403
DOORS
DN
cage
WINDOW = 42"x48"
WINDOW = 42"x48"
Safety
9'WIDE x 12'h. ROLL-UPGUARD RAIL 9'WIDE x 12'h. ROLL-UP
WINDOW = 42"x48"
INSPECTION
BREAK
AREA
FIRE
MAIN
FIRE
MAIN
FIRE
MAIN
TUNNEL
COVER
TUNNEL
COVERCOVER
TUNNEL
COVERCOVER
23 24 25 26 27 28 29
31 32 33 34 35 36 37 38 39 40 41
43 44 45
G
H
J
K
L
M
N
P
Q
R
U P
DN
UP
DN
UP
DN
UP
DN
UP
U P
U P
F I R
E C
O N
T R
O L
P A
N E
L S
B208-FIRST FLOOR
DOUBLE COLUMN #1
DOUBLE COLUMN #2
2 3 4 5 6 7 8 9 31 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
ROLL - UP
ACCOMMUNICATION
ITIT
A
B
C
D
E
F
G
H
K
L
M
N
O
P
R
S
T
S T
E A
M S
T E
A M
S T
E A
M
OPEN WELL
UTILITY TRENCH CAP
B220-FIRST FLOOR
B220-BASEMENT
b c d f h l m k g e a
TO
FORGE
SHOP
ELEVATOR
S T
E A
M
STATION
SUB
AIR CONDITIONER
ACCU-220-G-6
ACCU-220--1-1
T48
T47
T10
NID 1901477
AC
CHILLER
CODE 14159
AIR
COMPRESSOR
INTAKE
DECOMMISSIONED
GOVERNAIR
HVU-220-B-2
LEIBERT
AC
P
IP
IN
G
F O
R R
U B
B E
R R
O O
M
LEIBERT
C H
IL
L
E R
TRANE
T40
T41
T42RAISED CONCRETE
STEPPED
RAISED CONCRETE
STEPPED
RAISED CONCRETE
STEPPED
AC
C
U -2 -G -5
NEW PIT
SAME LEVEL
BLAST MACHINE PIT
bradley.niles Oval bradley.niles Oval bradley.niles Rectangle bradley.niles Rectangle bradley.niles Rectangle bradley.niles Rectangle
GENERAL NOTES
PLANT ENGINEERING
ROCK ISLAND ARSENAL JMTC
11-FEB-24
DRAWN
SCALE DATE
APPROVED
NO.
DRAWING
TARA-LGC
PLANT ENGINEERING DIVISION
ROCK ISLAND ARSENAL
CONCRETE MOUNTING PADS AND CAPS
SHEET 2 OF 10B. McCLURE B. NILES
NONE
MANUAL PROCESSES.
ACCESS WITH COMMERCIAL CONCRETE PUMPING OR POWER DOLLY OR
10. THE CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING WORK SITE
OR TRUCK AGITATORS HALL BE ACCORDING TO THE FOLLOWING:
THE MAXIMUM HAUL TIME FOR CONCRETE TRANSPORTED IN TRUCK MIXERS
DISCHARGING.
WITHOUT THE ADDITION OF WATER OR WATER AND CEMENT PRIOR TO
WORKABLE CONDITION, SATISFACTORY FOR PLACEMETN IN THE WORK
SHALL BE DELIVERED TO THE SITE OF THE WORK IN A PLASTIC AND
9. CONCRETE TRANSPORTED IN TRUCK MIXERS OR TRUCK AGITATIORS
SATURDAYS. FRAMING, TYING REBAR AND POURING WITH BE DAY SHIFT.
ON 2ND SHIFT STARTING FROM 2:30 TO 11:00 AT NIGHT OR
8. DEMOLITION/JACK HAMMERING/REMOVAL WILL BE PERFORMED
SHALL BE BASF SONOLASTIC SL-1 OR EQUAL.
RIGID FOAM INSULATION FOR VIBRATION ISOLATION. JOINT SEALANT
CLEAN UP IS COMPLETE, LINE MOUNTING PADS AND CAPS WITH 3/4"
7. EXPANSION JOINT MATERIAL UP TO 84" DEEP TYPICAL. AFTER
SHALL BE A MINIMUM OF 5000-PSI.
6. NEW CONCRETE FOR MACHINE MOUNTING PADS AND CAPS
CONVERTER ON ALL DIESEL ENGINES.
USED ARE GAS ENGINES. CONTRACTOR SHALL HAVE CATALYTIC
5. CONTRACTOR SHALL VENT EXHAUST OUTSIDE IF EQUIPMENT
REGULATIONS.
CONCRETE AND REBAR FROM RIA IN ACCORDANCE WITH LOCAL
BOLTS, CANS, BEAMS, CONDUIT, PLATES, PIPES, WOOD BLOCKS,
4. THE CONTRACTOR SHALL REMOVE ALL DEBRIS SUCH AS
OR THE UNDERLYING SOIL CAUSED BY THE CONSTRUCTION.
3. THE CONTRACTOR SHALL REPAIR ANY DAMAGE TO FLOOR
PRESENT MUST BE CUT OFF EVEN WITH SAW CUTS.
2. WHEN SAW CUTTING AROUND THE WORK AREA, REBAR
DUST DURING ENTIRE DEMOLITION AND CONSTRUCTION.
1. THE CONTRACTOR WILL USE WATER TO ELIMINATE DUST
OF DISCHARGE deg-F (deg-C)
CONCRETE TEMPERATURE AT POINT
HAUL TIME
HOURS MINUTE
50-64 (10-17.5)
65-90 (18-32) - WITHOUT RETARDER
1 30
1 3065-90 (18-32) - WITH RETARDER
21. DRAWING NOT TO SCALE.
RIA REPRESENTATIVES IMMEDIATELY.
SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF
20. ANY DISCREPANCIES IN PLANS, OR BETWEEN PLANS AND
OTHER EMBEDDED ITEMS AND INTO FORMS.
SO THAT CONCRTE IS WORKED AROUND REINFORCING AND
VIBRATING EQUIPMENT WITH HAND RODDING AND TAMPING
19. CONSOLIDATE PLACED CONCRETE USING MECHANICAL
PERFORMED BY COMPETENT, EXPERIENCED, QUALIFIED WORKMEN.
(AISC) STANDARDS AND SPECIFICATIONS. ALL WORK SHALL BE
COMPLY WITH LATEST AMERICAN INSTITUTE OF STEEL CONSTRUCTION
18. FABRICATION AND INSTALLATION OF STRUCTURAL STEEL SHALL
OF THE EXISTING CONCRETE.
DOWELS WILL BE DRILLED A MINIMUM OF 6" INTO THE VERTICAL FACE
BOTTOM SURFACE AND HAVE A MINIMUM OF 2 RODS IN EACH DIRECTION.
SPACING. REBAR SHOULD BE A MINIMUM OF 4" AWAY FROM TOP OR
17. DOUBLE TIED LAYERS OF #4 REBAR MESH (1/2"). 12" X-W
COMPLETION OF THE PROJECT.
16. CONTRACTOR SHALL CLEAN UP THE WORKSITE AFTER
SITE UNDER CONSTRUCTION.
15. CONTRACTOR SHALL PROVIDE BARRICADES AROUND JOB
PEDESTRIAN INTERACTIONS.
WITHIN THE BUILDING TO ENSURE SAFE TRAFFIC AND
EQUIPMENT/TRUCKS GOING IN/OUT OF THE BUILDING AND
14. CONTRACTOR WILL PROVIDE SPOTTER/GROUND MAN FOR
GRADE TO ALLOW FOR PROPER GROUNDING OF MACHINE.
INTO MOUNTING PADS AND LEFT EXPOSED 6-INCHES ABOVE
13. CONTRACTOR WILL PROVIDED ONE GROUND ROD DRIVEN
UTILIZE PROPER PPE.
SAFETY RULES OF THE TRAD AND ENSURE ALL PERSONNEL
12. CONTRACTOR WILL FOLLOW AND APPLY ALL STANDARD
REPRESENTATIVE FOR GATE PASS AND FUNCTIONALITY.
11. CONTRACTOR WILL COORDINATE WITH CONTRACTING OFFICER
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
The RAMP program is discussed in the RIA-JMTC AT training.
Department.
Contractors will comply with any instructions given by the Rock Island Arsenal Police installation RAMP security program (e.g. vehicles searches, wearing of ID badges, etc.).
Contractor personnel working on Rock Island Arsenal are subject to participation in change.
The COR will keep the contractors informed on the current FPCON or any possible FPCON
The FPCON descriptions will be provided in the RIA-JMTC AT training.
threat. Services will resume when FPCON level is reduced to level Bravo or lower.
During FPCONs Charlie and Delta, services may be discontinued/postponed due to higher iWATCH program. The iWATCH training will be provided in the RIA-JMTC AT training.
The Contractor and all associated subcontractors shall brief all employees on the local support of any future contract.
Contractors who routinely fail to return these items will not be issued them in placed in a drop box at a RIA-JMTC access point.
within 24 hours of no longer being needed. Items will returned to the COR or
RIA-JMTC electronic keys and access passes are accountable items and will be returned contractor5#32s employment.
IF00015 IF00015 at the end of the contract or the last day of an individual
Cards, installation badges, and/or access passes. Use FAR 52.204-9 or PADDS Clause
Contractor will acquire and need to return all issued U.S. Government Common Access thru the RIA Directorate of Emergency Services.
will provide guidance to complete the Access Control Records Check request Form security policies and procedures (provided by government representative). The COR
(Army Directive 2014-05/AR 190-13), applicable installation, facility access and local identification Index (NCIC-III) and Terrorist Screening Database (TSDB) standards and procedures using the National Crime Information Center interstate
Contractor and all associated subcontractor employees shall comply with adjudication training will be provided in the RIA-JMTC AT training.
all employees on the local iWATCH program. The iWATCH
The Contractor and all associated subcontractors shall brief be issued them in support of any future contract.
Contractors who routinely fail to return these items will not box at a RIA-JMTC access point.
needed. Items will returned to the COR or placed in a drop items and will be returned within 24 hours of no longer being
RIA-JMTC electronic keys and access passes are accountable individual contractor�s employment.
IF00015 at the end of the contract or the last day of an access passes. Use FAR 52.204-9 or PADDS Clause IF00015 Government Common Access Cards, installation badges, and/or Contractor will acquire and need to return all issued U.S.
Form thru the RIA Directorate of Emergency Services.
guidance to complete the Access Control Records Check request (provided by government representative). The COR will provide facility access and local security policies and procedures Directive 2014-05/AR 190-13), applicable installation, Index (NCIC-III) and Terrorist Screening Database (TSDB) (Army National Crime Information Center interstate identification comply with adjudication standards and procedures using the Contractor and all associated subcontractor employees shall require changes in contractor security matters or processes.
individual facility or installation change, the Government may contract, should the Force Protection Condition (FPCON) at any changes otherwise authorized by the change clause of this directed by DoD, HQDA, and/or local policy. In addition to the Personal Identity Verification of Contractor Personnel) as identity verification requirements (FAR clause 52.204-9, The contractor workforce must comply with all personal the installation Director of Emergency Services.
to meet installation access requirements to be accomplished by shall provide all information required for background checks The contractor and all associated subcontractors employees access pass being issued.
Operations Center prior to a RIA-JMTC electronic keys and contractor employee and subcontractor employee to the RIA-JMTC The contractor shall sign a Memorandum of Record for each completed.
Level I awareness training and assuring the training is training. The COR will be provided a copy of the RIA-JMTC AT controlled access areas shall complete AT Level I awareness requiring access to Army installations, facilities, or All contractor employees,including subcontractor employees, SECURITY NOTES
CONCRETE MOUNTING PADS AND CAPS
PLANT ENGINEERING
ROCK ISLAND ARSENAL JMTC
11-FEB-24
DRAWN
SCALE DATE
APPROVED
NO.
DRAWING
TARA-LGC
PLANT ENGINEERING DIVISION
ROCK ISLAND ARSENAL
CONCRETE MOUNTING PADS AND CAPS
SHEET 3 OF 10B. McCLURE B. NILES
NONE
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
B208 DOUBLE COLUMN #1 AND #2 LAYOUT
PLANT ENGINEERING
ROCK ISLAND ARSENAL JMTC
11-FEB-24
DRAWN
SCALE DATE
APPROVED
NO.
DRAWING
TARA-LGC
PLANT ENGINEERING DIVISION
ROCK ISLAND ARSENAL
CONCRETE MOUNTING PADS AND CAPS
SHEET 4 OF 10B. McCLURE B. NILES
NONE
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
3432534464
AIR INLET
CHILLER UNIT
40 TOOL MAGAZINE
SPINDLE CENTER
S/N 228271
MIST COLLECTOR
POWER INLET
CHIPS
MIST COLLECTOR
AIR INLET
POWER INLET
CHILLER UNIT
40 TOOL MAGAZINE
SPINDLE CENTER
CHIPS
S/N 207800
32687
34416 3419133996 34181
TRANS
FTV 8
40/
CHIP
TUBS
OPERATOR
CONTROL
STATIO
N
TRANS
FTV 8
50/
CHIP
TUBS
OPERATOR
CONTROL
STATIO
N
TRANS
FTV
0/
CHI
P
TUBS
OPERATOR
CONTROL
STATI
ON
TRANS
FTV
0/
CHI
P
TUBS
OPERATOR
CONTROL
STATI
ON
S/ N=7
9-
F0 0-
KM02
S/ N=7
9-
F0 0-
KM02
AIR
33883
T R
A N
S
HLD
H A
A S
S L
-2
CHIPS
DOOR HEIGHT 8'
DROP
AIR
DROP
AIR
DROP
AIR
DROP
AIR
PLEX
QUAD
120v
PLEX
QUAD
120v
PLEX
QUAD
120v
480v buss bar plug buss
DUPLEX
120v
Granite Table
7900183 R-90-254
DISCONNECT
FUSED
480v
SAFETY SWITCH
fused 3 phase
230V
SAFETY SWITCH
SINGLE phase
230V fused
FLOOR MOUNT
3 phase location transformer purposed
TRANSFORMER
WALL MOUNT
SINGLE phase
230V
RECEPTICAL
SINGLE phase
230V 20A
LINE
NETWORK
CHIPS
T O
O L
S
EC 300
33813
31947
B F
B F
B H
B F
RIA#35055
RIA#35056
26025
SUPERFLOW
M A
Z A
K H
C N
A
X I S
M
IB
32397
32475
C H
IP
S
HAAS SL30
RIA#34299
31099
S
BREAK
AREA
DN
UP
DN
UP
U P
LP-208-17a
L P b
L P
L P
K39K38K37K36K35K34K33K32 K40 K41
6"34'36'
CORNER OF EXISTING SLAB
#1
COLUMN
DOUBLE
#2
COLUMN
DOUBLE
bradley.niles Rectangle
B208 DOUBLE COLUMN #1 AND #2 DEMOLITION/CUT PLAN
PLANT ENGINEERING
ROCK ISLAND ARSENAL JMTC
11-FEB-24
DRAWN
SCALE DATE
APPROVED
NO.
DRAWING
TARA-LGC
PLANT ENGINEERING DIVISION
ROCK ISLAND ARSENAL
CONCRETE MOUNTING PADS AND CAPS
SHEET 5 OF 10B. McCLURE B. NILES
NONE
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
CURRENT VIEW CUT LINE VIEW
1" EXPANSION JOINT1" EXPANSION JOINT
12" EXISTING FOUNDATION 8"-12" EXISTING FOUNDATION 12" EXISTING FOUNDATION
NEW MOUNTING PAD
DEMO AS NEEDED TO INSTALL
PAD AND WORK WEST AND NORTH.
THE EXISTING SE CORNER OF THE EXISTING MOUNTING
MOUNTING PAD INSTALLED 2-3 YRS AGO. START FROM
DOUBLE COLUMN #2 WILL REMOVE PRIMARILY A 12" THICK
CONCRETE AND MISCELLANEOUS FOUNDATIONS.
NOTE: DOUBLE COLUMN #1 WILL REMOVE OLDER
B208 DOUBLE COLUMN #1 AND #2 ELEVATION/CONSTRUCTION PLAN
PLANT ENGINEERING
ROCK ISLAND ARSENAL JMTC
11-FEB-24
DRAWN
SCALE DATE
APPROVED
NO.
DRAWING
TARA-LGC
PLANT ENGINEERING DIVISION
ROCK ISLAND ARSENAL
CONCRETE MOUNTING PADS AND CAPS
SHEET 6 OF 10B. McCLURE B. NILES
NONE
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
12" EXISTING CONCRETE
LAYERS. 6" DOWEL EMBEDMENT STANDARD.
AND 3RD LAYER MIDWAY BETWEEN TOP AND BOTTOM
#4 REBAR MESH 4" FROM TOP AND BOTTOM SURFACES
" CA6
3/4" EXPANSION JOINT MATERIAL - SL-1 OR EQUIVALENT
ELEVATION.
THE FINAL 12" CAN BE SLOPED TO MEET THE EXISTING
OVER 10'. IF THIS CANNOT MEET EXISTING CONCRETE
MUST MAINTAIN NO GREATER THAN 1/4" DEVIATION
ALWAYS BE THE SAME ELEVATION. MOUNTING PADS
AREA SURROUNDING MOUNTING PADS WILL NOT
NOTE:
5000 PSI CONCRETE
B220 UTILITY TRENCH FILL & CAP LAYOUT
PLANT ENGINEERING
ROCK ISLAND ARSENAL JMTC
11-FEB-24
DRAWN
SCALE DATE
APPROVED
NO.
DRAWING
TARA-LGC
PLANT ENGINEERING DIVISION
ROCK ISLAND ARSENAL
CONCRETE MOUNTING PADS AND CAPS
SHEET 7 OF 10B. McCLURE B. NILES
NONE
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
34062
S/N=204077
TOOL CHANGER
MIE
34157
34163 34174
34179
COOLANT
CHILLER 34260
SUPERFLOW
GR
GR
T U
B
C H
I P
MAZAK
CHIP CONV.
REMOVAL OF
S/N 214442
H C
N
CHIP
TUB
S/N 213367
S/N 213311
P O
W E
R
TOOL
CHANGER
INTEGREX 300
MAZAK
S U
P E
R F
L O
W
C H
I P
C O
N V
R E
M O
V A
L O
F
CHIP TUB
C H
I P
T U
B
MAZAK
E-500 INTEGREX
DOUBLE SPINDLE
GR
Machining Cell #1
Finishing
Machining Cell #2
Finishing
Paint Booth and Finished Part Removal
Rough Part Installation
Dipping Station
Finished Part Tilting
Rough Part and
Dripping Station
Overhead Crane
Part Handling
S h u tt le C a r r ia g e
S ta n d b y S ta ti o n
S ta n d b y S ta ti o n
S ta n d b y S ta ti o n
S ta n d b y S ta ti o n
S ta n d b y S ta ti o n
P15 P16 P17 P18
O18O17O16O15O14
P14
T14 T15 T16 T17 T18 x 58' LONG x 2'DEEP
EXISTING TRENCH IS 2' WIDE
EXISTING TRENCH. NO ADDITIONAL DEMO REQUIRED
B220 UTILITY TRENCH FILL & CAP ELEVATION/CONSTRUCTION PLAN
PLANT ENGINEERING
ROCK ISLAND ARSENAL JMTC
11-FEB-24
DRAWN
SCALE DATE
APPROVED
NO.
DRAWING
TARA-LGC
PLANT ENGINEERING DIVISION
ROCK ISLAND ARSENAL
CONCRETE MOUNTING PADS AND CAPS
SHEET 8 OF 10B. McCLURE B. NILES
NONE
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
EXISTING CONCRETE 12" TO 24" THICK
TO MINIMIZE MOVEMENT. 6" DOWEL EMBEDMENT STANDARD.
#4 REBAR MIDWAY BETWEEN TOP AND BOTTOM
SAND
1/2" EXPANSION JOINT MATERIAL - SL-1 OR EQUIVALENT
5000 PSI CONCRETE
U P
T O
BLAST MACHINE PIT FILL & CAP LAYOUT
PLANT ENGINEERING
ROCK ISLAND ARSENAL JMTC
11-FEB-24
DRAWN
SCALE DATE
APPROVED
NO.
DRAWING
TARA-LGC
PLANT ENGINEERING DIVISION
ROCK ISLAND ARSENAL
CONCRETE MOUNTING PADS AND CAPS
SHEET 9 OF 10B. McCLURE B. NILES
NONE
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
SHELVES
ELEVATOR #3
M E N S
W O
M E N S
32707
DEL TECH
32055
NEW PIT
SAME LEVEL
K8
L8
M8 M9 M10 M11
L11
K11
TOP THAT CAN BE LEFT IN PLACE
THERE IS I-BEAM EDGING AROUND THE
PIT IS APPROXIMATELY 9' DEEP.
5' 18'
3'-6" 6'
2'-1"
EXISTING PIT. NO ADDITIONAL DEMO REQUIRED
bradley.niles Rectangle bradley.niles Rectangle
BLAST MACHINE PIT FILL & CAP ELEVATION/CONSTRUCTION PLAN
PLANT ENGINEERING
ROCK ISLAND ARSENAL JMTC
11-FEB-24
DRAWN
SCALE DATE
APPROVED
NO.
DRAWING
TARA-LGC
PLANT ENGINEERING DIVISION
ROCK ISLAND ARSENAL
CONCRETE MOUNTING PADS AND CAPS
SHEET 10 OF 10B. McCLURE B. NILES
NONE
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
12" EXISTING CONCRETE
SAND
CREATE A SAFE EDGE TO AVOID TRIPPING HAZARD
3/4" EXPANSION JOINT MATERIAL - SL-1 OR EQUIVALENT
4000 PSI MINIMUM CONCRETE
FILL PIT WITH SAND AND CAP WITH APPROXIMATELY 12" OF CONCRETE
File details come from the government source that posted it. Updated .