This document contains the Salient Characteristics for a Grounding Meter required under Solicitation Number FA462024QA939 issued by the Department of the Air Force Air Mobility Command. The key details are:

The contractor shall furnish a new portable 4-wire system for earthing and bonding continuity testing with the following minimum salient characteristics: 200M maximum lead length, resistance measurement range of 0.1m Ohm - 10 Ohm, measurement time maximum of 3 seconds, minimum 5000 measurements per single charge, and must include a base unit with handheld meter, Kelvin clamp & lead, base-meter lead, hand probe and lead, site calibration board, various spool lengths of lead, and a charger. Delivery is required within 60 days of award. This is not a brand name requirement, and the provided part number is a sample only. The related federal contract opportunity is a solicitation for the Grounding Meter with the stated requirements, with award to be made to the contractor providing the total delivered product cost.

View the file

Other files

File Type Posted
Amend 01 - SF 30 Cancel Solicitation.pdf PDF
24QA939 COMBO.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SALIENT CHARACTERISTICS

FOR

GROUNDING METER

April 2024

FA462024QA939 - Ground Metering Attach. 1 - Salient Characteristics

Salient Characteristics For

GROUNDING METER

Fairchild AFB, WA

1. BACKGROUND: Continued need to ensure safe operations of personnel and proper grounding of electrical equipment across Fairchild Air Force Base.

2. OBJECTIVES: Ensure continued safety of 92 ARW assets including equipment and personnel through safe detection and assessment of grounding systems, lightning protection systems, and electrical structures.

3. REQUIREMENTS: The contractor shall furnish a new grounding meter with the following minimum salient characteristics:

a) 4-wire resistance measurement method

b) 200M maximum lead length

c) Measured resistance ranges from 0.1m Ohm – 10 Ohm

d) Measurement time maximum of 3 seconds

e) Minimum measurements on single charge – 5000

f) Must include a base unit *with* handheld meter

g) Must include Plug Pack charger

h) Must include Kelvin clamp & lead (3M)

i) Must include Base-meter lead (3M)

j) Hand Probe and lead (1.2M)

k) Site calibration board

l) 60’ lead on 10’ engineered plastic spool

m) 250’ lead on 15” engineered plastic spool

n) 600’ lead on heavy duty cast nylon spool in stainless steel cage with 3:1 gear winder

4. DELIVERY: 60 days ARO

5. PARTS LIST: The following Part Number is a *sample* only. This is *NOT* a brand name requirement.

SAMPLE PART NUMBER SAMPLE PART DESCRIPTION

SAFEEARTH CS3 Portable 4-wire system for earthing and bonding continuity testing