Attach. 1 – Salient Characteristics.pdf
PDF 813 KB Posted
- Attached to
- JPRA Recessed Scissor Lift
- Solicitation number
- FA462022QA215
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 22QA215 Combo 25 MAY 22.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JPRA-West Recessed Loading Dock Scissors Lift
Required Characteristics:
Lifting Capacity - 5000 lbs.
Axle loading capacity of 2500 lbs over the sides and ends.
6 ft x 8 ft safety tread steel platform with minimum 8" toe guards (all four sides with minimum 2" black and yellow markings) and 12" x 72" hinged safety tread steel bridge.
8" lowered height.
Minimum 58" travel height.
Travel speed of 12 feet per minute.
5 HP- 230V/60HZ/3P continuous duty motor, UL listed.
Weatherproof, constant pressure UP and DOWN, push button control with 20 ft coil cord, fused circuit.
Magnetic motor starter and 24V control transformer, NEMA and UL listed.
Compliance with applicable OSHA, ANSI, and NEC codes.
10 year structural warranty; 2 year hydraulic assembly warranty.
Positive mechanical stops within the hydraulic cylinders (no less than two heavy duty machine grade cylinders).
Hydraulic cylinders shall be equipped with flow controls to prevent free fall.
Minimum three in-line hydraulic filters.
Removable safety maintenance leg.
Four heavy duty torque tubes; fabricate from structural steel shapes, rigidly welded and reinforced for strength, safety, stability, and ability to withstand deformation.
Lifetime lubricated bearings.
Chrome plated axles, shafts and rods.
Removable handrails, 42" high with midrail, safety chains, and kick plates.
Hot-dipped galvanized frame with baked-on enamel paint finish.
Unit shall be installed in a “permanent recessed concrete pit”.
*****Please see Images below (Page 3-4) to be used as BASIS FOR DESIGN ONLY*****
ADVANCE LIFTS PIT DIAGRAM FOR
UNITS WITH PLATFORM SAME WIDTH AS
BRIDGE.
FOR VISUAL REFERENCE ONLY, NOT TO SCALE.
PLATFORM
WIDTH + 2”
PLATFORM LENGTH
+ 6-1/2”
T-SERIES HOSE
RECESS
BRIDGE WIDTH + 2”
BRIDGE LENGTH
MINUS 3-3/4”
¾” BRIDGE
RECESS
UNIT LOWERED HEIGHT + ¼”
3” CONDUIT FOR HYDRAULIC
HOSE & 1” CONDUIT FOR
ELECTRICAL OPTIONS
121415
PIT DRAIN
AS BASIS FOR DESIGN
Page 4 of 4AS BASIS FOR DESIGN
| Attach. 1 – Salient Characteristics |
| As basis for design pg 2-3 |
File details come from the government source that posted it. Updated .