This document is an attachment titled "Att J-8_ Bid Schedule.xlsx" related to a federal contract opportunity for Maintenance and Repair (M&R) services at Joint Base McGuire-Dix-Lakehurst (JB MDL) in New Jersey.

The attachment provides a detailed bid schedule for the base year and option years of the contract, covering a wide range of maintenance and repair work including doors and windows, carpentry, flooring, ceilings, electrical, plumbing, painting, roofing, fencing, and miscellaneous labor. The bid schedule lists numerous specific line items with associated quantities, units, and unit costs for the various products and services required. The total estimated value of the base year is $0, with option years 1-4 and a 6-month extension also valued at $0 each, for a total contract value with the extension of $0.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Summary

Totals
Base$ - 0
OP1$ - 0
OP2$ - 0
OP3$ - 0
OP4$ - 0
6mo Ext$ - 0
Total with Ext$ - 0

BASE YEAR

MAINTENANCE AND REPAIR OF BUILDINGS
FACILITIES AND STUCTURES AT JOINT BASE MCGUIRE-DIX-LAKEHURST (JB MDL)
PERFORMANCE PERIOD BASE YEAR
CLIN#Description
0001The Contractor shall furnish all plant, labor, equipment, tools, supplies and materials and perform all work necessary to perform maintenance and repair of buildings, facilities and structures at JB MDL , NJ in accordance with Statement of Work for period of performance: 23 JUL 2024 through 23 JUL 2029.
QTYUNITCOSTCOST TOTAL
DOORS & WINDOWS
0002WOOD DOORS - INTERIOR
0002AAReplace and paint wood interior, flush solid door 3'-0" X 6'-8" thru 7'-3"10EA$ - 0$ - 0
0003WOOD DOOR FRAMES/MOLDINGS
0003AAReplace / paint single wood door frame, including casing and stops as applicable (maximum size 4'-0" X 8'-0")5EA$ - 0$ - 0
0003ABReplace / paint double wood door frame, including casing and stops as applicable (maximum size 8' - 0" X 8' - 0")5EA$ - 0$ - 0
0003ACReplace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 4'-0" x 8'-0"5EA$ - 0$ - 0
0003ADReplace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 8'-0" x 8'-0"5EA$ - 0$ - 0
0003AEReplace and paint wood door stops complete set for single wood door maximum size 4'-0"x 8'-0"5EA$ - 0$ - 0
0003AFReplace and paint wood door stops complete set for double wood door maximum size 8'-0"x 8'-0"5EA$ - 0$ - 0
0004METAL DOORS - INTERIOR
0004AAReplace and paint metal interior door 3'-0" width x up to 8'-0" height3EA$ - 0$ - 0
0004ABADD - B Label fire (90 min) rated door to metal door3EA$ - 0$ - 0
0005METAL DOORS - EXTERIOR
0005AAReplace and paint metal exterior door 3'-0" x up to 8'-0" height25EA$ - 0$ - 0
0005ABADD - B Label fire (90 min) rated door to metal door15EA$ - 0$ - 0
0006METAL DOOR FRAMES
0006AAReplace/paint single metal door frame, interior and exterior, B label fire (90min) rated maximum size 4'-0" x 8'-0"2EA$ - 0$ - 0
0006ABReplace/paint double metal door frame, interior and exterior, B label fire (90min) rated maximum size 8'-0" x 8'-0"2EA$ - 0$ - 0
0007REFIT/ADJUST EXISTING DOORS
0007AARefit wood single door and adjust hardware for proper operation1EA$ - 0$ - 0
0007ABRefit wood double doors and adjust hardware for proper operation1EA$ - 0$ - 0
0008DOOR LOUVERS
0008AAReplace and paint wood door louvers Maximum 6 SF1EA$ - 0$ - 0
0008ABReplace and paint metal door louvers Maximum 6 SF1EA$ - 0$ - 0
0009EXTERIOR WINDOW REPLACEMENT
0009AARemove/Replace impact resistant window in accordance with UFC 4-010-01450SF$ - 0$ - 0
0010ALLUMINUM STORE FRONT ENTRANCE DOORS
0010AAEntrance front doors 3'-0" x 7'-0" Entrance Door Full1EA$ - 0$ - 0
0010ABEntrance front doors 6'-0" x 7'-0" 1/2 Entrance Door Full1EA$ - 0$ - 0
0010ACEntrance front doors 5'-0" x 7'-0" 1/2 Entrance Door Full1EA$ - 0$ - 0
0010ADADD Tinted Glass1SF$ - 0$ - 0
0011MORTISE TYPE DOOR LOCKSET
0011AAMedium Duty type Mortise Lockset1EA$ - 0$ - 0
0011ABHeavy Duty type Mortise Lockset1EA$ - 0$ - 0
0012CYLINDER TYPE DOOR LOCKSET
0012AAReplace cylindrical type latch set passage SFIC (seven pin)20EA$ - 0$ - 0
0012ABReplace cylindrical type latch set Knob SFIC (seven pin)20EA$ - 0$ - 0
0012ACReplace cylindrical type latch set Lever SFIC (seven pin)20EA$ - 0$ - 0
0013ALUMINUM THRESHOLD
0013AAUp to 36" length2EA$ - 0$ - 0
0013AB>36" up to 72" length2EA$ - 0$ - 0
0014EXIT DEVICES
0014AAReplace exit or panic device stainless steel or bronze as specified - Single Door complete rim exit bolt includes pull with thumb piece and cylinder lock10EA$ - 0$ - 0
0014ABReplace surface mounted door closer as required with regular arm Interior and exterior, wood or metal doors10EA$ - 0$ - 0
0014ACReplace full mortise hinges, ball bearing, extra heavy weight, non rising pin, size up and including 5" x 5" with steel pins, complete including screws steel pins20EA$ - 0$ - 0
0014ADRemove existing hinges and install anodized aluminum geared continuous hinge, thrust bearing, heavy weight, unhandled with finish as required (half surface)20EA$ - 0$ - 0
0015DOOR ACCESSORIES
0015AAReplace astragal strip on double doors metal or wood (as applicable)1EA$ - 0$ - 0
0015ABReplace threshold weather stripping door sweep, extruded aluminum slotted holes, with screws1EA$ - 0$ - 0
0015ACReplace door holder - Floor Mounted1EA$ - 0$ - 0
0015ADReplace door holder - Door Mounted1EA$ - 0$ - 0
0015AEReplace surface mounted foot bolt zinc plated steel bolt, maximum length 6"1EA$ - 0$ - 0
0015AFReplace surface mounted chain bolt zinc plated steel bolt, maximum length 6"1EA$ - 0$ - 0
0015AGReplace/install floor mounted door stop, Aluminum1EA$ - 0$ - 0
0015AHReplace/install kick plate, size 10" x 30" thru 38" Aluminum1EA$ - 0$ - 0
0015AIReplace/install kick plate, size 10" x 30" thru 38" Stainless Steel1EA$ - 0$ - 0
0015AJReplace/install kick plate, size 10" x 30" thru 38" Plastic1EA$ - 0$ - 0
0015AKReplace/install push plate on doors 4" x 16" Aluminum1EA$ - 0$ - 0
0015ALReplace/install combination push-pull plate on doors 4" x 16" Bronze1EA$ - 0$ - 0
0015AMReplace/install combination push-pull plate on doors 4" x 16" Aluminum1EA$ - 0$ - 0
0015ANReplace/install combination push-pull plate on doors 4" x 16" Stainless Steel1EA$ - 0$ - 0
0015AOReplace Safety Glass in door maximum 12 SF1SF$ - 0$ - 0
0015APReplace Padlock Hasp1EA$ - 0$ - 0
0015AQReplace double glass window/door replace double strength glass in windows or doors maximum 9 SF1SF$ - 0$ - 0
0015ARGlazing Compound - Replace deteriorated glazing compound on metal or wood window sash1LF$ - 0$ - 0
CARPENTRY
0016REPLACE and PAINT GYPSUM WALL BOARD
0016AAReplace and Paint Gypsum wall board including finish taping, three coat of spackling, one coat of primer paint and two finish coats of paint - minimum 16 SF20,000SF$ - 0$ - 0
0016ABADD - Wall Board with Fire rating of 1 hour1SF$ - 0$ - 0

FAZIO, CHRISTOPHER R GS-09 USAF AMC 87 CES/CEOES: FAZIO, CHRISTOPHER R GS-09 USAF AMC 87 CES/CEOES:

price for fire rating and mold resistance is in the SF price. Word this line to include the two lower lines and that should be good enough right? Then I can remove 18AB,AC?

0016ACReplace and Paint Paperless moisture and mold resistant wall board 1/2" x 4' x 8' DensAmor Plus or Equivalent (minimum 16 SF)1SF$ - 0$ - 0
0017INTERIOR WOOD WALL BASE
0017AAWood Base Replace & paint 1" x 6" wood base minimum 5 LF500LF$ - 0$ - 0
0017ABShoe Molding Replace & paint or finish shoe molding as required to match existing Minimum 5 LF500LF$ - 0$ - 0
0018EXTERIOR LUMBER$ - 0
0018AAReplace & paint 1" x 4" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
0018ABReplace & paint 1" x 6" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
0018ACReplace & paint 2" x 4" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
0018ADReplace & paint 2" x 6" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
0018AEReplace & paint 2" x 8" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
0018AFReplace & paint 2" x 10" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
0018AGReplace & paint 2" x 12" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
0019EXTERIOR WOOD SIDING$ - 0
0019AAReplace & paint exterior vertical wood siding to match existing (minimum 8 SF ) nominal size 1" x 8"1SF$ - 0$ - 0
0019ABPlywood - 5/8" T 111 Exterior Siding in compliance with section 09550 of the specification1SF$ - 0$ - 0
0020PLYWOOD
0020AAReplace Plywood 1/4"500SF$ - 0$ - 0
0020ABReplace Plywood 1/2"1SF$ - 0$ - 0
0020ACReplace plywood 3/4"1SF$ - 0$ - 0
0021KITCHEN/BATHROOM CABINETS & COUNTERTOPS
0021AACabinet / Kitchen Wall Cabinets - remove and replace upper kitchen cabinets with new wood cabinet to conform with existing configuration.1LF$ - 0$ - 0
0021ABCabinet / Kitchen Base Cabinets - remove and replace base kitchen cabinets with new wood cabinets to conform with existing configuration1LF$ - 0$ - 0
0021ACCountertop - replace complete countertop with Solid Surface top1SF$ - 0$ - 0
0021ADcutout for sink kithchen to include faucet holes1EA$ - 0$ - 0
0021AEcut out for vaniaty to include faucet holes1EA$ - 0$ - 0
0021AFBacksplash - Solid Surface - Up to 6" high1LF$ - 0$ - 0
0022MEDICINE CABINETS
0022AACabinet / Medicine - replace to match existing size in compliance with section 10800 of the specification1EA$ - 0$ - 0
0022ABCabinet / Medicine With LED Lights - replace to match existing size in compliance with section 10800 of the specification1EA$ - 0$ - 0
FLOORING
0023FLOOR PREPARATION
0023AAPatch concrete floor surfaces with Portland cement max size 6" thick x 2 SF1EA$ - 0$ - 0
0023ABReplace rubber stair tread 13" wide x 48" 5/16 (Length typical)100EA$ - 0$ - 0
0023ACReplace Aluminum Safety Tread100EA$ - 0$ - 0
0024RUBBER or VINYL WALL BASE
0024AAReplace 4" high (all colors)40,000LF$ - 0$ - 0
0024ABReplace 6" high (all colors)10,000LF$ - 0$ - 0
0025VCT FLOORING (VINYL COMPOSITION TILE)
0025AARemove / Replace existing VCT with New VCT size 12" x 12" x 1/8 minimum 100 SF100,000SF$ - 0$ - 0
0025ABReplace aluminum edge strips60LF$ - 0$ - 0
0025ACReplace vinyl plastic edge strips60LF$ - 0$ - 0
0026SHEET FLOORING
0026AAFlooring / Replace Sheet Linoleum - installation shall be done in a fashion that will minimize floor seams all seams must conform to manufacturer's specification in compliance with section 09950 of the specification3,750SF$ - 0$ - 0
0026ABLinoleum Heat Weld Seaming1,000LF$ - 0$ - 0
0026ACIntegral Cove Base1,000LF$ - 0$ - 0
0027CERAMIC/QUARRY TILE
0027AAReplace quarry tile - Maximum size tile 6" x 6" x 3/4"1SF$ - 0$ - 0
0027ABReplace quarry tile cove base 2" to 5" high 3/4" maximum thick1SF$ - 0$ - 0
0027ACReplace quarry tile bull nose trim maximum 6" x 6" x 3/4" thick1LF$ - 0$ - 0
0027ADReplace ceramic tile maximum size tile 12" x12" x 3/4"1SF$ - 0$ - 0
0027AEReplace ceramic tile cove base maximum 6" high1SF$ - 0$ - 0
0027AFReplace ceramic tile bull nose trim maximum 6" x 12"1LF$ - 0$ - 0
0027AGRe-grout existing ceramic or quarry tile match existing minimum up to 3/8" wide1LF$ - 0$ - 0
0027AHThreshold / Marble - replace marble threshold up to 36"1EA$ - 0$ - 0
0028POURED EPOXY FLOORING
0028AAFurnish and Apply 250-375 mils thickness Poured Epoxy Floor1SF$ - 0$ - 0
0028ABADD Multi Colored Flakes1SF$ - 0$ - 0
0029CARPET
0029AAReplace Carpet with Broadloom Carpet2,000SY$ - 0$ - 0
0029ABReplace Carpet with Carpet Tiles (24" x 24")20,000SY$ - 0$ - 0
CEILINGS
0030SUSPENDED CEILINGS - TILES
0030AAReplace mineral fiber acoustical lay-in-panels in existing suspension systems maximum 3/4" thick patterns vary10,000SF$ - 0$ - 0
0030ABRemove and reinstall existing insulation when new grid system is installed1SF$ - 0$ - 0
0030ACReplace foil faced, fiber glass insulation over suspended ceiling or between framing members. Distance between members to determine width of insulation 3 1/2" thru 6" full thick, 11" thru 15" wide R11 thru R191SF$ - 0$ - 0
0031SUSPENDED CEILING SYSTEM
0031AAReplace suspension system for exposed grid acoustical lay in panels T-bar for exposed grid, painted white, does not include tile - 2' x 2' grid1SF$ - 0$ - 0
0032CEILING ACCESSORIES
0032AAReplace Suspended Ceiling HVAC diffusers, 2' x 2'15EA$ - 0$ - 0
0033INTERIOR MISCELLANEOUS ITEMS
0033AAHVAC Wall Register/Return - Up to 2 SF1EA$ - 0$ - 0
0033ABHVAC Wall Register/Return - Above 2 SF to Maximum 6 SF1EA$ - 0$ - 0
ELECTRICAL
0034ELECTRICAL RECEPTACLES/SWITCHES/BOXES
0034AAReceptacle / Wall, 125 Volt Duplex with ground - replacement to include new plate. In compliance with section 16415 of the specification1EA$ - 0$ - 0
0034ABReceptacle / 220 Volt for Range, Air Conditioner or Dryer replacement to include new plate in compliance with section 16415 of the specification1EA$ - 0$ - 0
0034ACReceptacle / Ground Fault Circuit Interrupter - replace to include new plate in compliance with section 16415 of the specification1EA$ - 0$ - 0
0034ADSwitch / Single Pole - replace to include new plate. In compliance with section 16415 of the specification1EA$ - 0$ - 0
0034AESwitch / Three Way - replace to include new plate. In compliance with section 16415 of the specifications1EA$ - 0$ - 0
0034AFSwitch / Dimmer - replace to include new plate. In compliance with section 16415 of the specification1EA$ - 0$ - 0
0034AGBox, Electrical / Switch, Receptacle, Work or Junction. In compliance with section 16415 of the specification1EA$ - 0$ - 0
0034AHPlate / Wall, Plastic - Replace Single, Double, Triple, combo or jumbo for GFI, Duplex receptacle or switch in compliance with section 16415 of the specification50EA$ - 0$ - 0
0035CEILING SURFACE MOUNT LIGHT FIXTURES
0035AASurface, Ceiling mounted fluorescent fixture size 2' x2' lensed, full flushed steel door Number lamps - 2 lamp type - Replace with LED equivalent1EA$ - 0$ - 0
0035ABSurface, Ceiling mounted fluorescent fixture size 2' x 4' lensed, full flushed steel door Number lamps -4' lamp type - Replace with LED equivalent1EA$ - 0$ - 0
0035ACSurface, Ceiling mounted fluorescent fixture size 1' x 4' wraparound lenses, Number lamps - 2 lamp type - Replace with LED equivalent1EA$ - 0$ - 0
0035ADSurface, Ceiling mounted fluorescent fixture size 2' x 4' wraparound lenses, Number lamps - 4' lamp type - Replace with LED equivalent1EA$ - 0$ - 0
0036TROFFER DROP IN STYLE LIGHT FIXTURES
0036AARecessed Grid 2' x 2' Troffer, Static, Lensed, full flush steel door. Number lamps -2 lamp type - Replace with LED equivalent40EA$ - 0$ - 0
0036ABRecessed Grid 2' x 4' Troffer, Static, Lensed, Number lamps -4 lamp type - Replace with LED equivalent30EA$ - 0$ - 0
0036ACOpen reflector, industrial (General Purpose) fixture, length 48" w/out lenses, 2 lamp type - Replace with LED equivalent1EA$ - 0$ - 0
0037HIGHBOY LIGHT FIXTURES
0037AASpecification Grade Highboy ,enclosed, pendant, integrally ballasted, industrial high intensity discharge fixture, cast aluminum prismatic acrylic reflector, lamp type - metal halide 250-400 MH1EA$ - 0$ - 0
0037ABSpecification Grade Highboy ,enclosed, pendant, integrally ballasted, industrial high intensity discharge fixture, cast aluminum prismatic acrylic reflector, lamp type - metal halide 250-400 MH - Replace with LED Equivalent1EA$ - 0$ - 0
0037ACSpecification Grade Highboy ,enclosed, pendant, integrally ballasted, industrial high intensity discharge fixture, cast aluminum prismatic acrylic reflector, lamp type -High Pressure Sodium 250-400 MH1EA$ - 0$ - 0
0037ADSpecification Grade Highboy ,enclosed, pendant, integrally ballasted, industrial high intensity discharge fixture, cast aluminum prismatic acrylic reflector, lamp type -High Pressure Sodium 250-400 MH - Replace with LED Equivalent1EA$ - 0$ - 0
0038EMERGENCY LIGHTS/EXIT SIGNS
0038AAReplace Emergency light 6 volt battery pack unit 2/two LED floodlights25EA$ - 0$ - 0
0038ABReplace Emergency light 2' x 2' w/ battery back up - LED25EA$ - 0$ - 0
0038ACReplace Exit Sign with LED Exit Sign - red color lettering20EA$ - 0$ - 0
0039LIGHT FIXTURE WIRING
0039AA1/2" EMT Conduit and Fittings1LF$ - 0$ - 0
0039AB3/4" EMT Conduit and Fittings1LF$ - 0$ - 0
0039ACMC Cable (awg 12)1LF$ - 0$ - 0
0039AD3/4 sealtite or equiv. whip connector (max. 6ft)1EA$ - 0$ - 0
0040ELECTRICAL MISC ITEMS (UPH) UNITS
0040ABReplace Exhaust Fan / Bathroom ceiling, 80 CFM with LED light - replace1EA$ - 0$ - 0
0040ACRange Hood / Kitchen with Light - Replace existing range hood with color and size to match existing1EA$ - 0$ - 0
INTERIOR/EXTERIOR PREPARATION & PAINTING
0041SURFACE PREPARATION
0041AASurface preparation for extreme scraping, patching and cleaning of grease from surface to be painted10,000SF$ - 0$ - 0
0041ABPressure Washing - pressure wash of exterior building surfaces to remove dirt, oil, residues and other coatings using a pump capable of minimum 3000 PSI. Bleach solution shall be sprayed on from top to bottom allowed to yield and rinse to remove all bleach residue100,000SF$ - 0$ - 0
0041ACSandblast of Masonry or Metal surfaces prior to painting5,000SF$ - 0$ - 0
0041ADBead Blast of Masonry or Metal Surfaces prior to painting1SF$ - 0$ - 0
0041AERepair Cracks in masonry not to exceed 2" wide500LF$ - 0$ - 0
0041AFRepair Holes in masonry surfaces not to exceed 2" diameter20EA$ - 0$ - 0
0041AGRepair Cracks in interior surfaces prior to painting100LF$ - 0$ - 0
0041AHRepair Holes in interior surfaces not to exceed 2" diameter100EA$ - 0$ - 0
0042INTERIOR PAINTING
0042AAFurnish all labor and materials necessary to prime and paint interior surfaces - 2 finish coats500,000SF$ - 0$ - 0
0042ABPaint 1 coat previously painted interior surface in accordance with specification500,000SF$ - 0$ - 0
0042ACEach additional interior coat of paint in accordance with specification100,000SF$ - 0$ - 0
0042ADSeal floor with finish coat, following manufacturors specifications1SF$ - 0$ - 0
0042AEApply 12-14 mil floor coating floor in accordance with specification1SF$ - 0$ - 0
0042AFApply 3-6 mil floor coating floor in accordance with specification1SF$ - 0$ - 0
0042AGApply non-skid surface in accordance with specification1SF$ - 0$ - 0
0043REFINISHING of STAINED, POLYURETHANED INTERIOR ITEMS
0043AARefinish with 1 coat in accordance with specification200SF$ - 0$ - 0
0043ABEach additional coat in accordance with specification200SF$ - 0$ - 0
0044PAINT EXTERIOR SURFACES
0044AAPaint 1 coat previously painted exterior surface in accordance with specifications200,000SF$ - 0$ - 0
0044ABEach additional exterior coat of paint in accordance with specifications200,000SF$ - 0$ - 0
0044ACSTUCCO repair and paint stucco to match1SF$ - 0$ - 0
0045VINYL WALL COVERINGS
0045AARemove wall covering , adhesives and apply skim coat and 1 coat of primer10,000SF$ - 0$ - 0
0046MASONRY - INTERIOR
0046AAPlaster - Replace / Repair wall or ceiling on metal lath or masonry surface. Repairs include replacement of lath, priming and painting of finished surface1SF$ - 0$ - 0
0046ABRepair interior masonry surfaces (cracks, spalls, holes) no larger than 2 inches100SF$ - 0$ - 0
0046ACReplace deteriorated interior masonry block to match existing1EA$ - 0$ - 0
0046ADReplace interior brick to match existing to include wall ties as required1EA$ - 0$ - 0
0047MASONRY - EXTERIOR
0047AARepair cracks up to 1/2' wide1LF$ - 0$ - 0
0047ABRepair holes 1/2" diameter or larger but not to exceed 2" in diameter1EA$ - 0$ - 0
0047ACSurface (cracks, holes or spalls) larger than 2" minimum 6 SF1SF$ - 0$ - 0
0047ADApply masonry filler and sealer or apply metal primer to sandblasted surfaces as applicable1LF$ - 0$ - 0
0047AERemove deteriorated masonry from brick/block surfaces and repoint to conform with existing surfaces1LF$ - 0$ - 0
0047AFReplace/apply caulking between similar or dissimilar interior or exterior construction material to include backup material as required250LF$ - 0$ - 0
PLUMBING
0048STALL - SOLID HDPE - To include all hardware
0048AASingle stall complete with swing out door - 2 walls and Door1EA$ - 0$ - 0
0048ABADD additional stall to above with Swing out Door - 1 wall and Door1EA$ - 0$ - 0
0048ACADD aditional Stall without Door - 1 Wall1EA$ - 0$ - 0
0048ADUrinal Divider1EA$ - 0$ - 0
0048AEADD - ADA compliant stall complete with handrails, doors - complete1EA$ - 0$ - 0
0049COMMODE
0049AAReplace commode, siphon jet, elongated bowl complete with flush valve with back-flow preventer and open or closed front seat without cover - Floor Mount1EA$ - 0$ - 0
0049ABReplace ADA compliant commode, siphon jet, elongated bowl complete with flush valve with back-flow preventer and open or closed front seat without cover - Floor Mount1EA$ - 0$ - 0
0049ACReplace commode, siphon jet, regular bowl complete with flush valve with back-flow preventer and open or closed front seat without cover - Wall Mount1EA$ - 0$ - 0
0049ADReplace ADA compliant commode, siphon jet, regular bowl complete with flush valve with back-flow preventer and open or closed front seat without cover - Wall Mount1EA$ - 0$ - 0
0049AEReplace Urinal - Wall hung type with flush valve and trap1EA$ - 0$ - 0
0049AFReplace P-trap to urinal1EA$ - 0$ - 0
0049AGReplace tail piece to urinal1EA$ - 0$ - 0
0049AHReset existing commode or Urinal and replace wax seal on commode1EA$ - 0$ - 0
0049AIRebuild flushometer using proper flushometer repair kit (commode & urinal)1EA$ - 0$ - 0
0049AJReplace flushometer handle1EA$ - 0$ - 0
0049AKReplace commode seat for regular or elongated bowl, closed or opened front, less cover1EA$ - 0$ - 0
0049ALReplace commode seat with cover for regular bowl with cover1EA$ - 0$ - 0
0050SINKS
0050AAReplace single compartment service or laundry sink max size 25" length, 24" width and 16" depth concrete or fiberglass, complete with faucet set, rubber stopper, chair, waste connection and stand 18" high1EA$ - 0$ - 0
0050ABReplace lavatory sink (maximum size 24" x 20") complete with 4" combination faucet set to match existing with riser pipe and trap1EA$ - 0$ - 0
0050ACReplace lavatory 4" center-set faucet set to match existing with drain fitting with pop up drain, and riser piping1EA$ - 0$ - 0
0050ADReplace lavatory 4" center-set faucet set to match existing with drain fitting with chair and stopper, and riser piping1EA$ - 0$ - 0
0050AEFaucet / Repair - to include deck faucet, center set, tub & shower diverter and replacement of all washers and seats1EA$ - 0$ - 0
0050AFRehang existing lavatory sink1EA$ - 0$ - 0
0050AGReplace swing type laundry or service sink faucet set to match existing1EA$ - 0$ - 0
0050AHReplace tail piece to lavatory1EA$ - 0$ - 0
0051LATRINE ACCESSORIES
0051AAThermostatic Shower Valve1EA$ - 0$ - 0
0051ABADA Compliant 1 1/2" OD Grab Bar1EA$ - 0$ - 0
0051ACADA Compliant Fold up seat1EA$ - 0$ - 0
0051ADReplace shower faucet handle to match existing1EA$ - 0$ - 0
0051AEReplace adjustable shower head {Vandal Resistant) 1/2 '' FIP female connection1EA$ - 0$ - 0
0051AFReplace toilet paper holder to match existing chrome plated brass1EA$ - 0$ - 0
0051AGReplace metal soap dish {to match existing chrome plated finish1EA$ - 0$ - 0
0051AHReplace latrine mirror stainless steel frame and theft-proof hanging clips maximum size 36" x 24"1EA$ - 0$ - 0
0051AIReplace ADA Compliant stainless steel grab bar to include fasteners1EA$ - 0$ - 0
0051AJReplace floor drain to match existing1EA$ - 0$ - 0
0051AKReplace perforated or slotted, brass chrome plated cover for existing floor drain 11" diameter maximum1EA$ - 0$ - 0
0052BATHROOM & KITCHEN ITEMS
0052AAReplace Shower Base / Fiberglass, White - 30" x 30" minimum to 36" x 36" maximum includes strainer1EA$ - 0$ - 0
0052ABReplace Shower Valve - Chrome Finish Pressure balanced, single lever scald guard with adjustable temperature limit stop1EA$ - 0$ - 0
0052ACReplace Trip Waste / Toe Operated Brass, 1 1/2" - trip waste and overflow to include chrome face plate1EA$ - 0$ - 0
0052ADReplace Face Plate / Chrome - trip waste face plate1EA$ - 0$ - 0
0052AEReplace Vanity / Solid Wood, White - with size to match existing 20", 24"or 30" including sink top to include new hardware1EA$ - 0$ - 0
0052AFReplace Bathroom Faucet / Single Lever Chrome - complete to include pop up drain stop1EA$ - 0$ - 0
0052AGReplace Closet Flange 4" - flange includes anchoring flange in place1EA$ - 0$ - 0
0052AHReplace Toilet / 1.6 Gal Flush, White - two piece close couple china toilet1EA$ - 0$ - 0
0052AIReplace Sink / Kitchen, Stainless Steel, Self Rimming Double bowl size 30" x 20" x 7" depth including S.S brackets strains1EA$ - 0$ - 0
0052AJReplace Faucet / Kitchen, Single Lever, 8" Center Set With spray replace including new aerator1EA$ - 0$ - 0
0052AKReplace Utility Tub / Fiberglass, Size 25 1/4" x 22 3/4" including legs built in strainer and complete 4" laundry tub facet set1EA$ - 0$ - 0
0059ALReplace Faucet / Laundry, 4" Ledge Mount - complete set including all required hardware1EA$ - 0$ - 0
0060COPPER PIPE
0060AAReplace 1/2" copper water line1LF$ - 0$ - 0
0060ABReplace 3/4" copper water line1LF$ - 0$ - 0
0060ACReplace 1" copper water line1LF$ - 0$ - 0
0061PIPE ACCESSORIES
0061AAReplace pipe hanger 1/2" thru 1"1EA$ - 0$ - 0
0061ABReplace pipe hanger1 1/4" thru 1 1/2"1EA$ - 0$ - 0
0061ACReplace pipe hanger 1 3/4" thru 2 1/2"1EA$ - 0$ - 0
0062PIPE COVERING/INSULATION, fiberglass to match existing maximum 10 LF
0062AAReplace pipe covering insulation, 1/2" thru 1" OD pipe1LF$ - 0$ - 0
0062ABReplace pipe covering insulation, 2" thru 2-1/2 "OD pipe1LF$ - 0$ - 0
0062ACReplace pipe covering insulation, 1" thru 1-1/2 "OD pipe1LF$ - 0$ - 0
0062ADReplace pipe covering insulation, 3" thru 3-1/2 "OD pipe1LF$ - 0$ - 0
0062AEReplace pipe covering insulation, 4" OD pipe1LF$ - 0$ - 0
0062AFReplace Supply Tube / Plastic - 3/8" OD or 1/2" OD plastic supply tube on lavatory, kitchen sink or toilet.1EA$ - 0$ - 0
ROLL-UP AND SECTIONAL OVERHEAD DOORS
0063OVERHEAD ROLL UP DOORS - Doors up to Nominal Height of 16 feet
0063AAReplace steel overhead roll-up doors up to nominal width of 16' - Uninsulated1,000SF$ - 0$ - 0
0063ABADD for insulated steel door1,000SF$ - 0$ - 0
0063ACReplace aluminum overhead roll-up doors up to nominal width of 16' - Uninsulated500SF$ - 0$ - 0
0063ADADD for insulated aluminum door500SF$ - 0$ - 0
0064SECTIONAL DOORS - Up to Nominal height of 16'
0064AAReplace steel overhead sectional doors up to nominal width of 16' - Unisulated500SF$ - 0$ - 0
0064ABADD for insulated sectional door500SF$ - 0$ - 0
0065OVERHEAD DOOR ACCESSORIES
0065AAReplace door springs - Sectional Doors6EA$ - 0$ - 0
0065ABReplace door springs - Roll Up Doors6EA$ - 0$ - 0
0065ACReplace cables6EA$ - 0$ - 0
0065ADReplace electric door operators {chain or belt) - 1/2HP6EA$ - 0$ - 0
0065AEReplace electric door operators {chain or belt) - 3/4 HP6EA$ - 0$ - 0
0065AFReplace electric door operators {chain or belt) - 1 HP6EA$ - 0$ - 0
0065AGReplace electric door operator safety bottom edge6EA$ - 0$ - 0
0065AHReplace pneumatic door operator safety bottom edge6EA$ - 0$ - 0
0065AIRepair/replace tracks6EA$ - 0$ - 0
0065AJReplace hinges and rollers.6EA$ - 0$ - 0
0065AKReplace neoprene internal hood baffles6LF$ - 0$ - 0
0065ALReplace neoprene astragal6EA$ - 0$ - 0
0065AMReplace vision panels6EA$ - 0$ - 0
0065ANReplace weather stripping300LF$ - 0$ - 0
0065AOReplace motor on operator3EA$ - 0$ - 0
0065APAdjust Limits on Overhead Door3EA$ - 0$ - 0
0065AQReplace 3 button, push button control station and all required metal raceway components6EA$ - 0$ - 0
EXTERIOR SIDING
0065Replace and/or cover existing surfaces, complete with vinyl siding and polystyrene insulating backer and all necessary trim, molding and fasteners for a complete job. Choice of color to be selected by QAR per delivery order
0065AASiding 8" w/backer1SF$ - 0$ - 0
0065ABSiding double 4" w/backer1SF$ - 0$ - 0
0065ACSiding vertical 10" w/backer1SF$ - 0$ - 0
0065ADOutside corner post1LF$ - 0$ - 0
0065AEInside corner post1LF$ - 0$ - 0
0065AFJ-Channel1LF$ - 0$ - 0
0065AGStarter strip (horizontal)1LF$ - 0$ - 0
0065AHDrip cap1LF$ - 0$ - 0
0065AISoffit panel - Solid1SF$ - 0$ - 0
0065AJSoffit panel - Perforated1SF$ - 0$ - 0
0065AKStarter strip (vertical)1LF$ - 0$ - 0
0065ALFascia panel 12"1LF$ - 0$ - 0
0065AMFurring Strip 1" X 3"1LF$ - 0$ - 0
0065ANInstall 3/4" insulation - Urethane rigid insulation1SF$ - 0$ - 0
0066SIDING OTHER THAN VINYL
0066AAAluminum Siding Panel .032" thick min corrugated or ribbed, color as specified1SF$ - 0$ - 0
0066ABEFIS, 2" thru 4" thick with reinforcement, finish to match existing texture and painted to match existing color1SF$ - 0$ - 0
0066ACFascia Aluminum .032" thick min, 12" thru 20" color as specified1LF$ - 0$ - 0
0067GUTTERS AND DOWNSPOUTS
0067AAAluminum Gutters / Leaders Downspouts repair / rehang including all hardware & sealant as directed by QAR. Size 3" thru 5" in compliance with section 07600 of the specification1LF$ - 0$ - 0
0067ABAluminum Gutters / Leaders Downspouts replace with minimum .027 thickness including all hardware & sealant as directed by QAR. Size 3" thru 5" in compliance with section 07600 of the specification1LF$ - 0$ - 0
0067ACAluminum Gutters / Leaders Downspouts clean and flush size 3" thur5" in compliance with section 07600 of the specification1LF$ - 0$ - 0
0067ADGutter Hardware Replace - brackets, hangers and joints1EA$ - 0$ - 0
0067AEAluminum Gutters / Leaders Downspouts repair / rehang including all hardware & sealant as directed by QAR. Size 6" thru 8" in compliance with section 07600 of the specification1LF$ - 0$ - 0
0067AFAluminum Gutters, Commercial Box or "K" replace with minimum .032 thickness including all hardware & sealant as directed by QAR. Size 6" thru 8" in compliance with section 07600 of the specification1LF$ - 0$ - 0
0067AGDownspout, Commercial Rectangular .025" thick min Aluminum, 3" x 4" brown, to include all elbows, connectors, and hardware1LF$ - 0$ - 0
0067AHAluminum Gutters / Leaders Downspouts repair / rehang including all hardware & sealant as directed by QAR. Size 10" thru 12" in compliance with section 07600 of the specification1LF$ - 0$ - 0
0067AIAluminum Gutters / Leaders Downspouts replace with minimum .032 thickness including all hardware & sealant as directed by QAR. Size 10" thru 12" in compliance with section 07600 of the specification1LF$ - 0$ - 0
0067AJAluminum Gutters / Leaders Downspouts clean and flush size 10" thru 12" in compliance with section 07600 of the specification1LF$ - 0$ - 0
0067AKGutter Hardware, Commercial Replace - brackets, hangers and joints1EA$ - 0$ - 0
ROOFING
0068ASPHALT SHINGLE ROOFING
0068AAReplace asphalt shingles to match existing 25 sf minimum1SF$ - 0$ - 0
0068ABROOF CAP repair / replace metal roof cap1LF$ - 0$ - 0
0069MINERAL SURFACE ROLLED ROOFING
0069AA90 PD Min Surface1SF$ - 0$ - 0
0069AB90 PD Sol Edge1SF$ - 0$ - 0
0069ACSteel Roofing corrugated or ribbed panel, 24 gauge min painted or zinc coated as specified1SF$ - 0$ - 0
0069ADEPDM 45 mil, fully adhered or loose laid with ballast as directed1SF$ - 0$ - 0
0069AEBuilt-Up Asphalt fully mopped 15 lb felt, number of plies, and surface finish to match existing roof (includes ballast if required)1SF$ - 0$ - 0
0069AFModified Bituminous Membrane fully mopped, 15 lb base with 150 mil cap, sheet surface to match existing roof1SF$ - 0$ - 0
CHAIN LINK FENCING
0070EXISTING FENCING
0070AARemove and dispose of existing fence 6'- 8' high -1LF$ - 0$ - 0
0071CHAIN LINK FENCE POSTS
0071AAReplace End post 3" diameter - 6' high fence1EA$ - 0$ - 0
0071ABADD per foot, end post 3" diameter - above 6' high fence1FT$ - 0$ - 0
0071ACReplace Corner post 4" diameter - 6' high fence1EA$ - 0$ - 0
0071ADADD per foot, Corner post 4" diameter - above 6' high fence1FT$ - 0$ - 0
0071AEReplace Line post single 2-1/2" diameter - 6" high fence1EA$ - 0$ - 0
0071AFADD per foot, Line Post 2-1/2" diameter - above 6' high fence1FT$ - 0$ - 0
0071AGReplace Horizontal Rail 1-5/8" diameter1LF$ - 0$ - 0
0072CHAIN LINK FENCE FABRIC
0072AAReplace up to 6' high, 9 ga. Wire, galvanized chain link fence fabric1LF$ - 0$ - 0
0072ABADD per foot height above 6' up to 8' high chain link fence fabric1LF$ - 0$ - 0
0072ACADD per foot height above 8' up to 12' high chain link fence fabric1LF$ - 0$ - 0
0072ADReplace Barbed Wire Top - 3 strand on single standoff post cap1LF$ - 0$ - 0
0073CHAIN LINK FENCE GATES
0073AAReplace Personnel Gate - Up to 4' wide x 6' high1EA$ - 0$ - 0
0073ABReplace Personnel Gate - Up to 4' wide - ADD per foot heght above 6'1EA$ - 0$ - 0
0073ACReplace 12' Double Gate up to 6' high1EA$ - 0$ - 0
0073ADReplace 12' wide double gate -ADD per foot height above 6'1FT$ - 0$ - 0
0073AEReplace 24' wide double gate up to 6' high1EA$ - 0$ - 0
0073AFReplace 24' wide double gate -ADD per foot height above 6'1FT$ - 0$ - 0
0073AGADD - 3 strand Barbed wire top to gate1LF$ - 0$ - 0
0073AHReplace Gate Latch/Locking Hardware - Padlock Type1EA$ - 0$ - 0
0073AIReplace Gate Latch/Locking Hardware - Childproof for CDC/Pool areas1EA$ - 0$ - 0
0074METAL PRIVACY FENCE
0074AARemove/Replace Slat on Metal Privacy Fence1LF$ - 0$ - 0
0074ABRemove/Replace Post on Metal Privacy Fence1LF$ - 0$ - 0
0074ACRemove/Replace Metal Privacy Fence Gate (including hardware)1SF$ - 0$ - 0
0074ADRemove/Replace Metal Privacy Fence Rail1LF$ - 0$ - 0
0074AERemove/Replace Metal Privacy Fence Section1SF$ - 0$ - 0
0075BOLLARDS
0075AAReplace Bollard - 4" Steel - Set in concrete, concrete filled and painted - Up to 4' high1EA$ - 0$ - 0
0075ABReplace Bollards - 6" Steel - Set in concrete, concrete filled and painted - Up to 4' high1EA$ - 0$ - 0
0075ACBollard Cover 4"1EA$ - 0$ - 0
0075ADBollard Cover 6"1EA$ - 0$ - 0
MISCELLANEOUS LABOR
0076Labor / Skilled - perform minor repairs as directed by QAR to include carpentry, electrical, plumbing and metal trades
0076AAPerform miscellaneous minor carpentry work500HR$ - 0$ - 0
0076ABPerform miscellaneous minor electrical work200HR$ - 0$ - 0
0076ACPerform miscellaneous minor plumbing work100HR$ - 0$ - 0
0076ADPerform miscellaneous labor work400HR$ - 0$ - 0
0076AEPerform miscellaneous sheet metal work100HR$ - 0$ - 0
0076AFPerform miscellaneous welding work50HR$ - 0$ - 0
0076AGMove Furniture and Partition - Disassemble, Move, and Re-assemble to facilitate replacement of flooring. Not to be used for lifting in place, movement of chairs, or furniture items not requiring assembly.1,000SF$ - 0$ - 0
MISC METAL WORK
0077Repair/replace radiator hardware
0077AAReplace radiator, convector or register cover to match existing Maximum 5 LF1LF$ - 0$ - 0
0077ABRehang existing radiator or convector to include fasteners and brackets Maximum 5 LF1LF$ - 0$ - 0
0077ACReplace aluminum air vent diffusers, 2' wide1EA$ - 0$ - 0
0077ADRepair/replace double wall metal chimneys1LF$ - 0$ - 0
ASBESTOS - LEAD BASED PAINT ABATEMENT and MOLD REMEDIATION
0078ASBESTOS ABATEMENT - Complete Removal, all tests , monitoring, setups, notifications, material, labor and disposal of asbestos floor tile and insulation
0078AAAsbestos floor tile and mastic Removal5,000SF$ - 0$ - 0
0078ABRemove Asbestos pipe covering insulation, replace with equivalent fiberglass insulation up to 4" pipe1LF$ - 0$ - 0
0078ACRemove Asbestos pipe covering insulation, replace with equivalent fiberglass insulation 4" thur 8" pipe1LF$ - 0$ - 0
0078ADRemove Asbestos pipe covering insulation, replace with equivalent fiberglass insulation 10" thur 12" pipe1LF$ - 0$ - 0
0078AERemove Asbestos boiler covering insulation, replace with equivalent insulation1SF$ - 0$ - 0
0078AFRemove Asbestos Duct or AHU covering insulation, replace with equivalent insulation1SF$ - 0$ - 0
0078AGRemove Asbestos Transite Panels1SF$ - 0$ - 0
0079MOLD REMEDIATION
0079AARemove mold from surfaces that can be wiped down or otherwise easily remediated1SF$ - 0$ - 0
0080LEAD BASED PAINT ABATEMENT
0080AAHandrails1LF$ - 0$ - 0
0080ABPipe 0 to 4" diameter1LF$ - 0$ - 0
0080ACPipe 4" to 8"" diameter1LF$ - 0$ - 0
0080ADPipe 8" to 12"" diameter1LF$ - 0$ - 0
0080AESiding and other flat surfaces1SF$ - 0$ - 0
0080AFOpen Trusses1SF$ - 0$ - 0
0080AGCollect, bag and dispose of bulk materials1EA$ - 0$ - 0
0080AHWindow Frames1SF$ - 0$ - 0

0081 BONDING FOR PROJECTS EXCEEDING $35k

Grand Total $ - 0

OPT YEAR 1

MAINTENANCE AND REPAIR OF BUILDINGS
FACILITIES AND STUCTURES AT JOINT BASE MCGUIRE-DIX-LAKEHURST (JB MDL)
PERFORMANCE PERIOD OPTION YEAR 1
CLIN#Description
1001The Contractor shall furnish all plant, labor, equipment, tools, supplies and materials and perform all work necessary to perform maintenance and repair of buildings, facilities and structures at JB MDL , NJ in accordance with Statement of Work for period of performance: 23 JUL 2024 through 23 JUL 2029.
QTYUNITCOSTCOST TOTAL
DOORS & WINDOWS
1002WOOD DOORS - INTERIOR
1002AAReplace and paint wood interior, flush solid door 3'-0" X 6'-8" thru 7'-3"10EA$ - 0$ - 0
1003WOOD DOOR FRAMES/MOLDINGS
1003AAReplace / paint single wood door frame, including casing and stops as applicable (maximum size 4'-0" X 8'-0")5EA$ - 0$ - 0
1003ABReplace / paint double wood door frame, including casing and stops as applicable (maximum size 8' - 0" X 8' - 0")5EA$ - 0$ - 0
1003ACReplace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 4'-0" x 8'-0"5EA$ - 0$ - 0
1003ADReplace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 8'-0" x 8'-0"5EA$ - 0$ - 0
1003AEReplace and paint wood door stops complete set for single wood door maximum size 4'-0"x 8'-0"5EA$ - 0$ - 0
1003AFReplace and paint wood door stops complete set for double wood door maximum size 8'-0"x 8'-0"5EA$ - 0$ - 0
1004METAL DOORS - INTERIOR
1004AAReplace and paint metal interior door 3'-0" width x up to 8'-0" height3EA$ - 0$ - 0
1004ABADD - B Label fire (90 min) rated door to metal door3EA$ - 0$ - 0
1005METAL DOORS - EXTERIOR
1005AAReplace and paint metal exterior door 3'-0" x up to 8'-0" height25EA$ - 0$ - 0
1005ABADD - B Label fire (90 min) rated door to metal door15EA$ - 0$ - 0
1006METAL DOOR FRAMES
1006AAReplace/paint single metal door frame, interior and exterior, B label fire (90min) rated maximum size 4'-0" x 8'-0"2EA$ - 0$ - 0
1006ABReplace/paint double metal door frame, interior and exterior, B label fire (90min) rated maximum size 8'-0" x 8'-0"2EA$ - 0$ - 0
1007REFIT/ADJUST EXISTING DOORS
1007AARefit wood single door and adjust hardware for proper operation1EA$ - 0$ - 0
1007ABRefit wood double doors and adjust hardware for proper operation1EA$ - 0$ - 0
1008DOOR LOUVERS
1008AAReplace and paint wood door louvers Maximum 6 SF1EA$ - 0$ - 0
1008ABReplace and paint metal door louvers Maximum 6 SF1EA$ - 0$ - 0
1009EXTERIOR WINDOW REPLACEMENT
1009AARemove/Replace impact resistant window in accordance with UFC 4-010-01450SF$ - 0$ - 0
1010ALLUMINUM STORE FRONT ENTRANCE DOORS
1010AAEntrance front doors 3'-0" x 7'-0" Entrance Door Full1EA$ - 0$ - 0
1010ABEntrance front doors 6'-0" x 7'-0" 1/2 Entrance Door Full1EA$ - 0$ - 0
1010ACEntrance front doors 5'-0" x 7'-0" 1/2 Entrance Door Full1EA$ - 0$ - 0
1010ADADD Tinted Glass1SF$ - 0$ - 0
1011MORTISE TYPE DOOR LOCKSET
1011AAMedium Duty type Mortise Lockset1EA$ - 0$ - 0
1011ABHeavy Duty type Mortise Lockset1EA$ - 0$ - 0
1012CYLINDER TYPE DOOR LOCKSET
1012AAReplace cylindrical type latch set passage SFIC (seven pin)20EA$ - 0$ - 0
1012ABReplace cylindrical type latch set Knob SFIC (seven pin)20EA$ - 0$ - 0
1012ACReplace cylindrical type latch set Lever SFIC (seven pin)20EA$ - 0$ - 0
1013ALUMINUM THRESHOLD
1013AAUp to 36" length2EA$ - 0$ - 0
1013AB>36" up to 72" length2EA$ - 0$ - 0
1014EXIT DEVICES
1014AAReplace exit or panic device stainless steel or bronze as specified - Single Door complete rim exit bolt includes pull with thumb piece and cylinder lock10EA$ - 0$ - 0
1014ABReplace surface mounted door closer as required with regular arm Interior and exterior, wood or metal doors10EA$ - 0$ - 0
1014ACReplace full mortise hinges, ball bearing, extra heavy weight, non rising pin, size up and including 5" x 5" with steel pins, complete including screws steel pins20EA$ - 0$ - 0
1014ADRemove existing hinges and install anodized aluminum geared continuous hinge, thrust bearing, heavy weight, unhandled with finish as required (half surface)20EA$ - 0$ - 0
1015DOOR ACCESSORIES
1015AAReplace astragal strip on double doors metal or wood (as applicable)1EA$ - 0$ - 0
1015ABReplace threshold weather stripping door sweep, extruded aluminum slotted holes, with screws1EA$ - 0$ - 0
1015ACReplace door holder - Floor Mounted1EA$ - 0$ - 0
1015ADReplace door holder - Door Mounted1EA$ - 0$ - 0
1015AEReplace surface mounted foot bolt zinc plated steel bolt, maximum length 6"1EA$ - 0$ - 0
1015AFReplace surface mounted chain bolt zinc plated steel bolt, maximum length 6"1EA$ - 0$ - 0
1015AGReplace/install floor mounted door stop, Aluminum1EA$ - 0$ - 0
1015AHReplace/install kick plate, size 10" x 30" thru 38" Aluminum1EA$ - 0$ - 0
1015AIReplace/install kick plate, size 10" x 30" thru 38" Stainless Steel1EA$ - 0$ - 0
1015AJReplace/install kick plate, size 10" x 30" thru 38" Plastic1EA$ - 0$ - 0
1015AKReplace/install push plate on doors 4" x 16" Aluminum1EA$ - 0$ - 0
1015ALReplace/install combination push-pull plate on doors 4" x 16" Bronze1EA$ - 0$ - 0
1015AMReplace/install combination push-pull plate on doors 4" x 16" Aluminum1EA$ - 0$ - 0
1015ANReplace/install combination push-pull plate on doors 4" x 16" Stainless Steel1EA$ - 0$ - 0
1015AOReplace Safety Glass in door maximum 12 SF1SF$ - 0$ - 0
1015APReplace Padlock Hasp1EA$ - 0$ - 0
1015AQReplace double glass window/door replace double strength glass in windows or doors maximum 9 SF1SF$ - 0$ - 0
1015ARGlazing Compound - Replace deteriorated glazing compound on metal or wood window sash1LF$ - 0$ - 0
CARPENTRY
1016REPLACE and PAINT GYPSUM WALL BOARD
1016AAReplace and Paint Gypsum wall board including finish taping, three coat of spackling, one coat of primer paint and two finish coats of paint - minimum 16 SF20,000SF$ - 0$ - 0
1016ABADD - Wall Board with Fire rating of 1 hour1SF$ - 0$ - 0

FAZIO, CHRISTOPHER R GS-09 USAF AMC 87 CES/CEOES: FAZIO, CHRISTOPHER R GS-09 USAF AMC 87 CES/CEOES:

price for fire rating and mold resistance is in the SF price. Word this line to include the two lower lines and that should be good enough right? Then I can remove 18AB,AC?

1016ACReplace and Paint Paperless moisture and mold resistant wall board 1/2" x 4' x 8' DensAmor Plus or Equivalent (minimum 16 SF)1SF$ - 0$ - 0
1017INTERIOR WOOD WALL BASE
1017AAWood Base Replace & paint 1" x 6" wood base minimum 5 LF500LF$ - 0$ - 0
1017ABShoe Molding Replace & paint or finish shoe molding as required to match existing Minimum 5 LF500LF$ - 0$ - 0
1018EXTERIOR LUMBER
1018AAReplace & paint 1" x 4" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
1018ABReplace & paint 1" x 6" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
1018ACReplace & paint 2" x 4" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
1018ADReplace & paint 2" x 6" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
1018AEReplace & paint 2" x 8" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
1018AFReplace & paint 2" x 10" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
1018AGReplace & paint 2" x 12" exposed exterior lumber (minimum 5 LF)1LF$ - 0$ - 0
1019EXTERIOR WOOD SIDING
1019AAReplace & paint exterior vertical wood siding to match existing (minimum 8 SF ) nominal size 1" x 8"1SF$ - 0$ - 0
1019ABPlywood - 5/8" T 111 Exterior Siding in compliance with section 09550 of the specification1SF$ - 0$ - 0
1020PLYWOOD
1020AAReplace Plywood 1/4"500SF$ - 0$ - 0
1020ABReplace Plywood 1/2"1SF$ - 0$ - 0
1020ACReplace plywood 3/4"1SF$ - 0$ - 0
1021KITCHEN/BATHROOM CABINETS & COUNTERTOPS
1021AACabinet / Kitchen Wall Cabinets - remove and replace upper kitchen cabinets with new wood cabinet to conform with existing configuration.1LF$ - 0$ - 0
1021ABCabinet / Kitchen Base Cabinets - remove and replace base kitchen cabinets with new wood cabinets to conform with existing configuration1LF$ - 0$ - 0
1021ACCountertop - replace complete countertop with Solid Surface top1SF$ - 0$ - 0
1021ADcutout for sink kithchen to include faucet holes1EA$ - 0$ - 0
1021AEcut out for vaniaty to include faucet holes1EA$ - 0$ - 0
1021AFBacksplash - Solid Surface - Up to 6" high1LF$ - 0$ - 0
1022MEDICINE CABINETS
1022AACabinet / Medicine - replace to match existing size in compliance with section 10800 of the specification1EA$ - 0$ - 0
1022ABCabinet / Medicine With LED Lights - replace to match existing size in compliance with section 10800 of the specification1EA$ - 0$ - 0
FLOORING
1023FLOOR PREPARATION
1023AAPatch concrete floor surfaces with Portland cement max size 6" thick x 2 SF1EA$ - 0$ - 0
1023ABReplace rubber stair tread 13" wide x 48" 5/16 (Length typical)100EA$ - 0$ - 0
1023ACReplace Aluminum Safety Tread100EA$ - 0$ - 0
1024RUBBER or VINYL WALL BASE
1024AAReplace 4" high (all colors)40,000LF$ - 0$ - 0
1024ABReplace 6" high (all colors)10,000LF$ - 0$ - 0
1025VCT FLOORING (VINYL COMPOSITION TILE)
1025AARemove / Replace existing VCT with New VCT size 12" x 12" x 1/8 minimum 100 SF100,000SF$ - 0$ - 0
1025ABReplace aluminum edge strips60LF$ - 0$ - 0
1025ACReplace vinyl plastic edge strips60LF$ - 0$ - 0
1026SHEET FLOORING
1026AAFlooring / Replace Sheet Linoleum - installation shall be done in a fashion that will minimize floor seams all seams must conform to manufacturer's specification in compliance with section 09950 of the specification3,750SF$ - 0$ - 0
1026ABLinoleum Heat Weld Seaming1,000LF$ - 0$ - 0
1026ACIntegral Cove Base1,000LF$ - 0$ - 0
1027CERAMIC/QUARRY TILE
1027AAReplace quarry tile - Maximum size tile 6" x 6" x 3/4"1SF$ - 0$ - 0
1027ABReplace quarry tile cove base 2" to 5" high 3/4" maximum thick1SF$ - 0$ - 0
1027ACReplace quarry tile bull nose trim maximum 6" x 6" x 3/4" thick1LF$ - 0$ - 0
1027ADReplace ceramic tile maximum size tile 12" x12" x 3/4"1SF$ - 0$ - 0
1027AEReplace ceramic tile cove base maximum 6" high1SF$ - 0$ - 0
1027AFReplace ceramic tile bull nose trim maximum 6" x 12"1LF$ - 0$ - 0
1027AGRe-grout existing ceramic or quarry tile match existing minimum up to 3/8" wide1LF$ - 0$ - 0
1027AHThreshold / Marble - replace marble threshold up to 36"1EA$ - 0$ - 0
1028POURED EPOXY FLOORING
1028AAFurnish and Apply 250-375 mils thickness Poured Epoxy Floor1SF$ - 0$ - 0
1028ABADD Multi Colored Flakes1SF$ - 0$ - 0
1029CARPET
1029AAReplace Carpet with Broadloom Carpet2,000SY$ - 0$ - 0
1029ABReplace Carpet with Carpet Tiles (24" x 24")20,000SY$ - 0$ - 0
CEILINGS
1030SUSPENDED CEILINGS - TILES
1030AAReplace mineral fiber acoustical lay-in-panels in existing suspension systems maximum 3/4" thick patterns vary10,000SF$ - 0$ - 0
1030ABRemove and reinstall existing insulation when new grid system is installed1SF$ - 0$ - 0
1030ACReplace foil faced, fiber glass insulation over suspended ceiling or between framing members. Distance between members to determine width of insulation 3 1/2" thru 6" full thick, 11" thru 15" wide R11 thru R191SF$ - 0$ - 0
1031SUSPENDED CEILING SYSTEM
1031AAReplace suspension system for exposed grid acoustical lay in panels T-bar for exposed grid, painted white, does not include tile - 2' x 2' grid1SF$ - 0$ - 0
1032CEILING ACCESSORIES
1032AAReplace Suspended Ceiling HVAC diffusers, 2' x 2'15EA$ - 0$ - 0
1033INTERIOR MISCELLANEOUS ITEMS
1033AAHVAC Wall Register/Return - Up to 2 SF1EA$ - 0$ - 0
1033ABHVAC Wall Register/Return - Above 2 SF to Maximum 6 SF1EA$ - 0$ - 0
ELECTRICAL
1034ELECTRICAL RECEPTACLES/SWITCHES/BOXES
1034AAReceptacle / Wall, 125 Volt Duplex with ground - replacement to include new plate. In compliance with section 16415 of the specification1EA$ - 0$ - 0
1034ABReceptacle / 220 Volt for Range, Air Conditioner or Dryer replacement to include new plate in compliance with section 16415 of the specification1EA$ - 0$ - 0
1034ACReceptacle / Ground Fault Circuit Interrupter - replace to include new plate in compliance with section 16415 of the specification1EA$ - 0$ - 0
1034ADSwitch / Single Pole - replace to include new plate. In compliance with section 16415 of the specification1EA$ - 0$ - 0
1034AESwitch / Three Way - replace to include new plate. In compliance with section 16415 of the specifications1EA$ - 0$ - 0
1034AFSwitch / Dimmer - replace to include new plate. In compliance with section 16415 of the specification1EA$ - 0$ - 0
1034AGBox, Electrical / Switch, Receptacle, Work or Junction. In compliance with section 16415 of the specification1EA$ - 0$ - 0
1034AHPlate / Wall, Plastic - Replace Single, Double, Triple, combo or jumbo for GFI, Duplex receptacle or switch in compliance with section 16415 of the specification50EA$ - 0$ - 0
1035CEILING SURFACE MOUNT LIGHT FIXTURES

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .