This document appears to be a technical drawing labeled "3HE_5-SAMPLE_PLATE" related to a federal contract opportunity for a Dilution Refrigerator System. The drawing provides detailed specifications for a sample plate component, including dimensions, hole patterns, material requirements, and manufacturing instructions.

The related federal contract opportunity is for the fabrication and delivery of a cryogen-free, bottom-loaded Dilution Refrigerator System for use at the High Flux Isotope Reactor (HFIR) facility. The system must be capable of continuous operation with a base temperature less than 50 mK and a cooling power of more than 200 mW at 100 mK. The solicitation is being issued by the Department of Energy, with a requirement to deliver the system by April 24, 2023. No other details about the contract, such as pricing terms, set asides, or incumbent contractors, are provided in the given information.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

C

B

5 X . 4 38

.219

A

___ J_ __ _ I

I

:: :: : : I : :� ,:: : I : : :: ::

: : I::

f i , !, ··i, : ___ j !, -----· ,,._,. __,:,,_:: _: ----i L__:�i-- i

I I I I I

NEXT USED ASSEMBLY

6 X ¢.177 THRU

ON 1.575 B.C.D.

.600 y:

i ''

. 4

¢ 3. 50 10 X R.25

¢I. 20 i ' ' I

¢ 2. 00

I , I I '

----L-+--- - I '

' l

- ,,.. ·-f o X R . 2 5

6 X 6 0 . 0

5 X 1/4-28 UNF - 2B TAP

THRU ON 3.0 B.C.D.

5 X 7 2 . 0

2 1 NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE

FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.

THIS DRAWING IS THE PROPERTY OF OAK RIDGE NATIONAL LABORATORY.

APPROVAL BLOCK

REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE

0 ORIGINAL ISSUE PER XXXXXXXXX-XXXXXX

NOTES:

I. PLEASE MAKE 2 BY APRIL 24, 2023

MALCOLM COCHRAN

865-368-0814

COCHRANMJ@ORNL.GOV

101 COPPER

UNITS: INCHES

MATERIAL

DEFAULT TOLERANCES

X.XX ±.01

x.xxx ±.005

ANGULAR ±.5

BREAK ALL SHARP EDGES

EXCEPT AS NOTED: .060 MAX

SURFACE

ROUGHNESS: 125 U.N.O.

DRAWING NUMBER

ASTM B187

SPECIFICATION

HIGH FLUX

ISOTOPE

REACTOR

PROJECT NAME

WBS AREA

START PART, INCH

DRAFTING STD: ASME Y14.100

D & T: ASME Y14.5 3HE _5-SAMPLE-PLA TE

THIRD

ANGLE

PROJECTION

SIZE SCALE

C 1/1

WEIGHT

0.27 LB

SPALLATION

NEUTRON

SOURCE

REV

SHEET

D

C

B

A

Sheet 1
Views
FRONT
TOP
RIGHT
DWG_ISO
bottom_5
Zones
D4
D3
D2
D1
C4
C3
C2
C1
B4
B3
B2
B1
A4
A3
A2
A1