Atlas_MLIs.pdf
PDF 4 MB Posted
- Attached to
- NCAO Bearing Oil Indicator
- Solicitation number
- 140R2024Q0078
About this file
This document is a product bulletin for Orion Instruments' Magnetic Level Indicator (MLI), the Atlas model. It provides detailed technical specifications and configuration options for this high-performance magnetic level indicator, which is designed as an alternative to sight gauge devices.
The Atlas MLI is available in a range of chamber sizes, process connection types, and materials of construction, including exotic alloys and plastics. It can be equipped with various level transmitters, switches, and indicators to provide comprehensive level monitoring and control capabilities. The bulletin covers key features such as the robust float design, custom scale options, and temperature/pressure ratings up to 538°C (1,000°F) and 310 bar (4,500 psig). It also details insulation options for high-temperature and cryogenic applications, as well as accessories like magnetic particle traps and heat tracing. The information provided suggests this MLI product line would be suitable for the oil level indicator requirements outlined in the related federal contract opportunity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140R2024Q0078.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Designed as an alternative and upgrade to sight gauge devices, Magnetic Level Indicators (MLI) from Orion Instruments® are manufactured to reliably and continuously provide accurate liquid level in a wide range of applications. Our MLI product line—manufactured globally at multiple facilities—requires minimum maintenance and eliminates vapor or liquid emission problems, which are common with sight glass. Orion Instruments specializes in precision-engineered excellence and offers highly-customized configurations and options for process environments, including those with extreme temperatures and pressures.
The Atlas™ is the standard high-performance magnetic level indicator from Orion Instruments®. Atlas is a single-chamber design with either a 2”, 21⁄2”, or 3” chamber diameter, as required by the application. There are several configuration styles including top mount models. Consult factory for options not listed in this bulletin.
The Atlas MLI is produced in a wide range of materials, including exotic alloys and plastics. Orion offers the most complete selection of process connection types and sizes in the industry.
Atlas can be equipped with a variety of level transmitters and switches as well as flag and shuttle indicators with or without stainless steel scales. This enables the MLI to be a complete level and monitoring control.
APPLICATIONS
• Feedwater heaters
• Industrial boilers
• Oil/water separators
• Flash drums
• Surge tanks
• Gas chillers
• Deaerators
• Blowdown flash tanks
• Hot wells
• Vacuum tower bottoms
• Alkylation units
• Boiler drums
• Propane vessels
• Storage tanks
Atlas™ Magnetic Level Indicator
FEATURES
• Numerous chamber styles (or configurations) are available for each design. Consult factory for options not listed in this bulletin.
• Complete range of level switches and level transmitters
• Fabricated, non-magnetic chamber assembly produced in a wide range of metal and plastic materials
• A wide range of process connections is available
• Precision manufactured float with internal magnets and magnetic flux ring
• ASME and EN 1092-1 process connections available
• Flag or shuttle type indicator with stainless steel scale to measure height or percentage of level, volume or content
• Standard float stop springs at top and bottom of chamber
• Exceptional code qualified welding
The patented REVEAL™ indicator incorporates a positive-stop design which limits the rotation of each flag to a half-turn. This eliminates “over-flipping” which commonly occurs on other indicator designs.
Scale Options:
• Inches / Feet
• Running Inches
• Millimeters / Meters
• Centimeters / Meters
• Percent (5% increments)
• Gallons
• Liters
Si ng le S ca le
Du al
S ca le
Standard flag and shuttle offering. Custom colors available.Each flag contains a high-strength magnet
InstaSeal™ valve allows for an effective vacuum seal
Double custom D-ring end plug ensures a reliable seal that keeps moisture out
All-metal high contrast powder coated or anodized flags are wider to enhance overall visibility
Robust 316 stainless steel enclosure designed to face the elements
Extruded shatter-resistant viewing window enhances visibility and allows the flags to position closely to the float, enhancing the magnetic coupling
+ 60 m (200 �.)
viewing angle 140°
The float’s 360° magnet assembly produces a strong and consistent flux array allowing visual indication through chambers as thick as schedule 160.
ORION FLOAT TECHNOLOGY
CAPABILITIES
Weld Ring: Secures float cap to main body
Flux Ring: Absorbs magnetic energy and directs it outward
Magnets: A full array surrounds the float with a strong and consistent magnetic field
OPTIONS
• Process pressures up to 310 bar (4,500 psig) �
• Process Temperatures up to 538 °C (1,000 °F) �
• Total level specific gravities as low as 0.25 �
• Interface float designs available for liquid specific gravity differentials as little as 0.1
• Adequate buoyancy to operate effectively and freely in many viscous liquids, including crude oil
Support Ring: Provides reinforcement for the main float body
Float Body: Robust and durable construction delivers many years of reliable operation
• Teflon-S® PTFE and PFA slip-assistant coating
• Special coatings for abrasion and chemical resistance
• Float retrieval hook
• Float Projection Curve: If the liquid density changes, a float curve will reveal the offset
Float Projection Curve
The float contained within the magnetic level indicator is perhaps the most important element of the instrument. Its structural design, volume displacement, weight, and buoyancy force are all carefully considered when a float is specified for a particular application.
Orion engineers have designed and tested hundreds of floats to gather the most accurate data available. We have designs for thousands of unique applications around the world, including high pressure, high temperature, and interface.
Maximum capabilities can vary depending on combination of pressure, temperature, and media specific gravity.
MAGNETIC LEVEL INDICATOR SPECIFICATIONS
Design Single chamber
Materials of construction – Chamber Metal alloys: see selection table digit 5
– Rail & window 316 stainless steel (Reveal™) rail with polycarbonate window
Aluminum rail with polycarbonate or glass window
– Float 316 stainless steel and titanium (exotic alloys available); varies depending on process conditions
Construction options ASME B31.1, ASME B31.3, ASME code Stamp [U,Um,S], PED and NACE
Approvals Industrial, Industrial PED: ATEX II 1 G c T6 (non-electrical equipment)
Certified material test report (CMTR) Available upon request
Pressure class ratings ASME 150#, 300#, 600#, 900#, 1500#, 2500#
EN PN16, PN25, PN40, PN63, PN100, PN160, PN250, PN320
Process connection sizes 1⁄2" to 6" / DN 15 to DN 150
Process connection types Refer to page 10 for detail
Measuring range 30 to 1524 cm (12 to 600 inches)
Temperature range -196 to +538 °C (-320 to +1000 °F)
Pressure range Full vacuum to 310 bar (4500 psi)
Specific gravity range Min. 0.25
Visual Indicators Magnetically actuated flag assembly in contrasting orange/black, yellow/black, red/white colors, or high visibility shuttle follower (custom colors available)
REVEAL™ flag assembly seal Vacuum and sealed with double D-ring & InstaSeal™ valve
REVEAL™ visual indicator Visible from 60 m (200’)
Ratings of REVEAL visual indicator IP 68
Aluminum visual indicator Visible from 30 m (100’)
Scale options Etched stainless steel with either height or percentage units (custom markings available)
Switch options Electric microswitch
Electric reed switch
Transmitter options Model JM4 Jupiter magnetostrictive (refer to Orion bulletin ORI-150)
Analog reed chain transmitter
High temperature options Electric or steam tracing with or without special high temperature insulation
High temperature insulation Fiberglass material
Low temperature options Cryogenic insulation with special polymeric frost extension
Top Mount Atlas
Vent Connection
Broad range of alloy and plastic chambers
Wide range of process connections
Welded end cap or flange top
Flag or shuttle style indicators
316 SS scale for a variety of units:
feet/inches meters/cm percent % volume custom
Insta-Seal™ valve
Dome cap or flange bottom
Top float stop spring (standard)
High level switch (optional)
Drain Connection
Low level switch (optional)
Bottom float stop spring (standard)
ASME code construction available:
B31.1 B31.3
NACE Construction available:
MR0103
MR0175
Anodized aluminum or 316 SS indicator housing
Atlas™ MLI
HIGH-TEMPERATURE INSULATION
Orion specializes in custom fiberglass insulation blankets for MLIs of all shapes and sizes. They are constructed with high-quality materials capable of constant contact with temperatures up to 538 °C (1000 °F). This insulation is available as personnel protection or with heat tracing options for freeze protection or process temperature maintenance.
CRYOGENIC INSULATION & FROST EXTENSION
To facilitate operation where the product is kept cold via chillers, refrigerants, and condensers, cryogenic insulation is provided. By insulating the MLI with a specialized cryogenic jacket, process temperatures can be maintained in the liquid state down to -196 °C (-320 °F).
A frost extension option is available to prevent ice from collecting on the visual indicator, thereby decreasing the visibility. The extension is constructed of durable acrylic plastic and is provided standard with all cryogenic insulation.
MAGNETIC PARTICLE TRAP
Magnetic Particle Traps, or magtraps, provide protection for Orion’s line of Magnetic Level Indicators. Particles composed mostly of ferrite, often from car-bon steel piping, are widespread throughout process piping. These particles enter the MLI via the process connections during normal fill and drain opera-tions. The magnetic float located inside the MLI attracts these particles over time. Eventually, the buildup will be enough to cause the float to become stuck inside the chamber. This results in the MLI either reading inaccurately or not at all. The trap collects the particles which can be cleaned periodically to ensure continued operation of the magnetic level indicator.
HEAT TRACING: ELECTRIC & STEAM
For applications where process freeze protection or temperature maintenance is required, heat tracing will allow the MLI to operate uninterrupted through-out harsh, cold conditions.
Electric Heat Tracing is available in self-regulating, constant wattage, and min-eral insulated varieties. Contact the factory for more information.
JUPITER MODEL JM4 MAGNETOSTRICTIVE TRANSMITTER SPECIFICATIONS
Jupiter® Model JM4 on Atlas™
OCT REED CHAIN TRANSMITTER SPECIFICATIONS
OCT
on Atlas™
Measuring Range: 15 to 503 cm (6 to 198 inches)
Resolution: 13 mm (±0.50 inches)
Repeatability: <6 mm (0.25 inches)
Non-Linearity: <0.4% full span averaged over span
Upper Transition Zone: 10.2 cm (4 inches)
Lower Transition Zone: 10.2 cm (4 inches)
Power Input: 12 to 36 VDC (2-wire)
Signal Output: 4 to 20 mA
Housing Type: NEMA 4X, IP66
Housing Material: Cast Aluminum or 316 SS
Area Classifications: FM/CSA
EP
Process Temperature: No insulation: -40 to +93 °C (-40 to +200 °F) Requiring insulation: up to +260 °C (+500 °F)
Ambient Temperature at Electronics: -40 to +70 °C (-40 to +158 °F)
Mounting Arrangement: External mount probe with integral top or bottom mounted electronics
Measuring Range: 15 to 999 cm (6 to 400 inches)
Resolution: .4 mm (.014")
Repeatability: ±0.005% of full span or 0.356 mm (0.014 inches) (whichever is greater)
Linearity: 0.8 mm (0.030 inches) or 0.01% of probe length (whichever is greater)
Upper Dead Zone: less than 7.6 cm (3 inches) when bottom mounted electronics
Lower Dead Zone: less than 7.6 cm (3 inches) when top mounted electronics
Damping: 0 – 10 seconds; adjustable
Power (at terminals) 2-wire:
HART®: 16 to 36 VDC FOUNDATION fieldbus™ Explosion Proof: 9 to 17.5 VDC FISCO/FNICO: 9 to 32 VDC
Signal Output: 4-20 mA with HART®: 3.8 to 20.5 mA usable FOUNDATION fieldbus™: H1 (ITK Ver. 6.1.1)
Display: Graphic liquid crystal display
Housing Material: IP67/die-cast aluminum A413 (<0.4% copper);
optional stainless steel
Area Classifications: USA/Canada/ATEX/IECEx/INMETRO/Korea XP, IS, NI, DIP (see specific product literature for more detail)
Safety Integrity Level: SIL rating pending
Process Temperature:
External Mount: -195 to +454 °C (-320 to +850 °F) No insulation -40 to +79 °C (-40 to +175 °F) Requiring insulation up to +454 °C (+850 °F)
Ambient Temperature at Electronics:
-40 to +80 °C (-40 to +175 °F) LCD: -20 to +70 °C (-5 to +160 °F)
ELECTRONIC SWITCH SPECIFICATIONS
Model: OES ORS
Description: DPDT magnetically actuated, bi-stable cam drive snap action switch Hermetically sealed bi-stable reed switch
Supply Voltage: 10.1 amp; 125-250 VAC 250VAC/150VDC max Maximum Dead Band: ±0.75" float travel ±0.50" float travel
Temperature Range: No insulation -50 to +121 °C (-58 to +250 °F) Requiring insulation up to +260 °C (+500 °F)
No insulation -50 to +121 °C (-58 to +250 °F) Requiring insulation up to +260 °C (+500 °F)
Enclosure Material: Cast aluminum (standard) Stainless steel
Model OES Model ORS
Consult factory for pneumatic switch specifications.
Consult the individual MLI accessory catalogs for their respective hazardous location approvals.
MOUNTING TO ATLAS – MODEL ORS
WIRING – MODEL ORS
Position the ORS switch on the MLI body so that the centerline of the stainless steel tube which houses the switch is at the desired switch point level. The switch should be oriented so that the green grounding screw is closest to the top of the MLI. Install the clamps around the MLI and over the mounting tabs of the switch. Tighten the clamps until the switch is firmly secured to the MLI. If required, place the insulation between the MLI body and the ORS switch before securing the clamps.
The switch leads are color coded as follows:
white = common black = normally closed (float below switch) red = normally open The wiring diagram shows both conditions of the switch relative to the float.
FLOAT ABOVE SWITCH
FLOAT BELOW SWITCH
1 (RED)
C (WHITE)
C (WHITE)
2 (BLACK)
1 (RED)
2 (BLACK)
MOUNTING TO ATLAS – MODEL OES
WIRING – MODEL OES
FLOAT BELOW SWITCH
Position the OES switch on the MLI body so that the centerline of the switch housing is at the desired switch point level. Remove the housing cover and ensure that the switch is ori-ented so that the arrow on the internal mechanism is pointing toward the top of the MLI.
Install the clamps around the MLI and over the mounting brackets on the top and bottom of the housing. Tighten the clamps until the switch is firmly secured to the MLI. Replace the housing cover. If required, place the insulation between the MLI body and the OES switch before securing the clamps.
The lower cable entry is protected with a plastic plug. The upper opening is sealed with a steel plug. If it is preferable to wire through the upper cable entry, the steel plug may be moved to the lower opening. The DPDT switch has two sets of contacts. Refer to the wiring diagram or label on the mechanism itself.
ORION INSTRUMENTS
OES ELECTRIC SWITCH
INSTALL WITH ARROW POINTING UP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
1 Atlas™ Magnetic Level Indicator
1 PRODUCT NAME
E English (inches) M Metric (cm)
2 UNIT OF MEASUREMENT
Connection orientation Chamber top Chamber bottom 1 Side / Side Welded end cap Flange 2 Side / Side Flange Welded end cap 3 Side / Side Flange Flange 5 Top / Bottom* Flange Flange 7 Top / Side Welded end cap with process connection Flange 9 Side / Bottom Flange Welded end cap with process connection
3 MOUNTING CONFIGURATION & CHAMBER CONSTRUCTION
Model:
Digit:
X = product with a specific customer requirement
Option 7 Option 1 with three process connections Option 9
Option 1 Option 5Option 2 Option 3
MODEL NUMBER - ATLAS
Model:
Digit:
X = product with a specific customer requirement
ASME
A 150#
B 300#
C 600#
D 900#
E 1500#
F 2500#
EN 1092-1
1 PN 16
2 PN 25
3 PN 40
4 PN 63
5 PN 100
6 PN 160
7 PN 250
8 PN 320
4 CHAMBER/FLANGE RATING
Metallic
A 316/316L stainless steel chamber
B 316/316L stainless steel chamber with carbon steel fittings & flanges
C 304/304L stainless steel chamber
D 304/304L stainless steel chamber with carbon steel fittings & flanges
G 321 stainless steel
H 347 stainless steel
J 904L stainless steel
N Titanium
P Monel®
Q Hastelloy C-276
R Alloy 20
S Inconel® 625
T Incoloy® 825
U 254 SMO
5 MATERIAL OF CONSTRUCTION
Metallic construction – PED
D NACE MR0175/MR0103
E ASME B31.3 & NACE MR0175/MR0103 �
J Industrial
Z ASME B31.3 �
ASME flanges A RF slip-on (standard for digit 4 = A, B, C) B RF weld neck C RF Socketweld Flange (digit 4 = A or B) J RTJ weld neck (standard for digit 4 = D, E, F)
EN 1092-1 flanges 6 Weld neck (Type 11) EN 1092-1 Type A 7 Weld neck (Type 11) EN 1092-1 Type B2 (standard for digit 4 = 4, 5, 6, 7, 8) 8 Weld neck (Type 11) EN 1092-1 Type B1 (standard for digit 4 = 1, 2, 3) N No chamber flange
CONSTRUCTION GRADE
CHAMBER FLANGE(S) TYPE
Chamber flanges
Metallic construction – Non-PED
1 Industrial Grade (standard)
2 ASME B31.1 for Power Piping Standard
3 ASME B31.3 for Process Piping Standard �
4 Industrial Grade with NACE MR0175/0103
6 ASME B31.3 and NACE MR0103/0175 �
8 Industrial Grade (extruded outlet)
9 ASME B31.3 (extruded outlet) �
➀ Consult factory if ASME B31.3 certification is required on carbon steel constructions with design temperatures below -17 °C (0 °F).
Digit:
X = product with a specific customer requirement
Threaded or Welded
M Threaded NPT-M (male)
P Pipe nipple plain end
R Pipe nipple butt weld end
N Threaded NPT-F (female) ➀
Q Socket weld ➀
W Threadolet™ ➁
T Sockolet™ ➁
S Weldolet™ ➁
ASME ➃
A RF slip-on flange ➂
B RF weld neck flange
C RF socketweld flange
J RJ weld neck flange
EN 1092-1 ➃
6 Weld neck (Type 11) EN 1092-1 Type A
7 Weld neck (Type 11) EN 1092-1 Type B2
8 Weld neck (Type 11) EN 1092-1 Type B1
8 PROCESS CONNECTION TYPE
Threaded NPT-M, option M
Threaded NPT-F, option N
Threadolet NPT-F, option W
Socket weld, option Q
Sockolet, option T
Weldolet, option S
Slip-on flange, option A (process connection size < chamber size)
Machined flange, option A (process connection size ≥ chamber size)
Weld neck flange, option B, J, 8, 7, 6 (process connection size < chamber size)
Weld neck flange, option B, J, 8, 7, 6 (process connection size ≥ chamber size)
Pipe nipple plain end, option P
Pipe nipple butt weld end, option R
ASME
A 1⁄2"
B 3⁄4"
C 1"
D 11⁄2"
E 2"
F 21⁄2"
G 3"
H 4"
J 6"
EN 1092-1
1 DN 15
2 DN 20
3 DN 25
4 DN 40
5 DN 50
6 DN 65
7 DN 80
8 DN 100
9 DN 150
9 PROCESS CONNECTION SIZE
➀ Only available in combination with digit 9 = A, B or C.
➁ Consult factory for sizes > 1”.
➂ Machined flange (to smaller pipe size) if process connection size ≥ chamber size (e.g., 2”/DN50 process connection and 2” chamber).
➃ Pressure ratings for flanges are by default the same as selected in Digit 4
Gaskets for metallic flanges
A Flexible graphite fiber ➀
B Spiral wound with graphite filler and carbon steel outer ring ➁
C Spiral wound with graphite filler, inner ring included matching chamber material, and carbon steel or stainless steel outer ring based on chamber material ➁
D RTJ oval ring ➃
E RTJ octagonal ring ➂ ➃
10 GASKET STYLE FOR CHAMBER FLANGE(S)
N None (if mating flanges are not supplied)
➀ Standard gasket for RF flanges with rating up to 300# / PN 63.
➁ Standard gasket options for RF flanges with rating > 300# / PN 63. Winding material matches chamber material.
➂ Standard ring joint for RJ ANSI flanges (digit 7 = J).
➃ Ring joint material matches flange material.
Digit:
X = product with a specific customer requirement
A 304 Stainless steel class 2 A193 Gr. B8 Class 2 / A194 Gr. 8
C 316 stainless steel class 2 A-193 Gr B8M class 2 / A-194 Gr 8M
D 316 stainless steel class 2 with PTFE coating A-193 Gr B8M class 2 / A-194 Gr 8M
G 316 stainless steel class 2 + NACE A-193 Gr B8M class 2 / A-194 Gr 8MA
S Alloy steel with zinc plating (+210 °C (+390 °F) is maximum temp for zinc-plated bolting) A-193 Gr B7 / A-194 Gr 2H
T Alloy steel with zinc plating + NACE (+210 °C (+390 °F) is maximum temp for zinc-plated bolting) A-193 Gr B7M / A-194 Gr 2HM
M Alloy steel ➀ A-193 Gr B7 / A-194 Gr 2H
P Alloy steel + NACE ➀ A-193 Gr B7M / A-194 Gr 2HM
12 13
CHAMBER BOLTING MATERIAL
VENT SIZE VENT TYPE
N None (if mating flanges are not supplied)
➀ Available only in combination with digit 5 = B or D.
Pressure class of vent flange is as selected in digit 4.➀
ASME
1 1⁄2"
2 3⁄4"
3 1"
4 11⁄2"
5 2"
ASME
1 Threaded NPT-F (female) with plug
2 Socket weld
3 Threaded NPT-M (male)
4 Pipe nipple plain end
5 Pipe nipple butt weld end
6 RF slip-on flange ➀
7 RF weld neck flange ➀
9 RJ weld neck flange ➀
EN 1092-1
A DN 15
B DN 20
C DN 25
D DN 40
E DN 50
EN 1092-1
R Weld neck (Type 11) EN 1092-1 Type A ➀
S Weld neck (Type 11) EN 1092-1 Type B2 ➀
T Weld neck (Type 11) EN 1092-1 Type B1 ➀
Valves
A Ball Valve, FNPT × FNPT
B Ball Valve, SW × SW
C Ball Valve, SW × FNPT
D Gate Valve, FNPT × FNPT
E Gate Valve, SW × SW
F Gate Valve, SW × FNPT
G RF Flange Ball Valve w/spool
H RF Flange Gate Valve w/spool
N None N None
ANSI
1 1⁄2"
2 3⁄4"
3 1"
4 11⁄2"
5 2"
EN (DIN)
A DN 15
B DN 20
C DN 25
D DN 40
E DN 50
14 DRAIN SIZE
N None
15 DRAIN TYPE
ASME
1 Threaded NPT-F (female) with plug
2 Socket weld
3 Threaded NPT-M (male)
4 Pipe nipple plain end
5 Pipe nipple butt weld end
6 RF slip-on flange ➀
7 RF weld neck flange ➀
9 RJ weld neck flange ➀
N None
Pressure class of drain flange is as selected in digit 4.➀
EN 1092-1
R Weld neck (Type 11) EN 1092-1 Type A ➀
S Weld neck (Type 11) EN 1092-1 Type B2 ➀
T Weld neck (Type 11) EN 1092-1 Type B1 ➀
Valves
A Ball Valve, FNPT × FNPT
B Ball Valve, SW × SW
C Ball Valve, SW × FNPT
D Gate Valve, FNPT × FNPT
E Gate Valve, SW × SW
F Gate Valve, SW × FNPT
G RF Flange Ball Valve w/spool
H RF Flange Gate Valve w/spool
Digit:
X = product with a specific customer requirement
16 CHAMBER MODIFICATION FOR MOUNTING OF OPTIONAL SWITCHES AND/OR TRANSMITTER
ATLAS can be combined with various externally mounted accessories, including switches and transmitters. In these cases minor changes to the chamber and float design may be required.
For digit 16, match up the MLI product with the appropriate transmitter, switch or combination of both.
For OES/ORS switch, refer to the switch selection data for temperature limitations and insulation options. Match up the switch model code digit 7 with the MLI model codes 16 and 17.
For OCT transmitter, refer to OCT information for temperature limitations and match up the OCT model code with the MLI model codes 16 and 17.
For Jupiter transmitter, refer to JM4 information for temperature limitations and possible mounting configurations.
Match up the Jupiter model code with the MLI model codes 16 and 17.
All transmitters and switches must be ordered separately.
Switch only (no transmitter)
Y OES or ORS switch(es) clamp mounted to chamber
Z OES or ORS switch(es) attached to switch mount rod
Jupiter magnetostrictive transmitter with at least one OES or ORS switch
Mounting of Jupiter
Mounting of switches clamp mounted to chamber attached to switch mount rod
Top mount without offset ➀ A ➁ L ➂ ➃
Top mount offset, with or without high temperature bend B M ➃
Bottom mount offset, with or without high temperature bend C P ➃
OCT reed chain transmitter (no switches)
8 Top mount
9 Bottom mount
N No switch or transmitter added
➀ Available only in combination with digit 3 = 1 and digit 13 = N or 1
➁ Jupiter: max. 79 to 454 °C (175 to 850 °F) with insulation
➂ Jupiter: max. 79 to 454 °C (175 to 850 °F) with insulation (digit 17 = A, C)
➃ Available when digit 17 = A, B, C or D
Jupiter magnetostrictive transmitter only (no switches)
1 Top mount without offset ➀
2 Top mount offset, with or without high temperature design
3 Bottom mount offset, with or without high temperature design
➀ It is recommended to not fully enclose the MLI indicator in boiler / steam drum applications ➁ Matches external mount Jupiter with digit 3 = E, F, H ➂ Matches external mount Jupiter with digit 3 = K, L, M ➃ With maximum temperature up to +260 °C (+500 °F); consult factory for application temperature higher than +260 °C (+500 °F).
Insulation pad for indicator and transmitter
E Indicator only digit 16 = N, Y 121 °C (250 °F) < T ≤ 260 °C (500 °F)
F Indicator only digit 16 = N 261 °C (501 °F) < T ≤ 537 °C (1000 °F)
U Transmitter only digit 16 = 1, 2, 3, A, B, C ➁ digit 16 = 8, 9 79 °C (175 °F) < T ≤ 260 °C (500 °F) 93 °C (200 °F) < T ≤ 260 °C (500 °F)
R Indicator & transmitter digit 16 = 1, 2, 3, A, B, C ➁ digit 16 = 8, 9 121 °C (250 °F) < T ≤ 260 °C (500 °F) 121 °C (250 °F) < T ≤ 260 °C (500 °F)
K Transmitter only digit 16 = 1, 2, 3, A, B, C ➂ & digit 18 = N 261 °C (501 °F) < T ≤ 454 °C (850 °F)
V Indicator & transmitter digit 16 = 1, 2, 3, A, B, C ➁ 261 °C (501 °F) < T ≤ 454 °C (850 °F)
17 INSULATION OPTIONS
Insulation blanket for personnel protection
A Chamber pipe only up to 260 °C (500 °F)
B Chamber pipe only 261 to 538 °C (501 to 1000 °F)
C Chamber and flanges up to 260 °C (500 °F)
D Chamber and flanges 261 to 538 °C (501 to 1000 °F)
Cryogenic insulation
L Process temperature down to -100 °C (-150 °F)
P Process temperature down to -196 °C (-320 °F)
Other options for temperature maintenance or freeze protection
H Electric heat tracing ➃
S Steam tracing (3⁄8" tubing) ➃
J Steam jacket (1⁄2" NPT inlet/outlet) ➃
N None ➀ Indicator: max. 121 °C (250 °F) OCT transmitter: max. 93 °C (200 °F) Jupiter transmitter: max. 79 °C (175 °F)
Digit:
X = product with a specific customer requirement
Total level
1 Orange / black metal flags
2 Yellow / black metal flags
3 Red / white metal flags (standard)
4 Red / silver metal flags +371 °C (+700 °F) and above
Interface level
5 Orange / black metal flags
6 Yellow / black metal flags
7 Red / white metal flags (standard)
8 Red / silver metal flags +371 °C (+700 °F) and above
A Orange / black metal flags with yellow float diagnostics ➀
B Yellow / black metal flags with orange float diagnostics ➀
C Red / white metal flags with yellow float diagnostics ➀
D Red / silver metal flags with black float diagnostics ➀ +371 °C (+700 °F) and above
F Orange / black metal flags with yellow float diagnostics ➀
G Yellow / black metal flags with orange float diagnostics ➀
H Red / white metal flags with yellow float diagnostics ➀
J Red / silver metal flags with black float diagnostics ➀ +371 °C (+700 °F) and above
S Fluorescent orange shuttle / follower ➁ Maximum Temperature +120 °C (+249 °F)
T Fluorescent orange shuttle / follower ➁ Maximum Temperature +120 °C (+249 °F)
N No indicator (For external use of external Jupiter mount only)
18 MEASUREMENT TYPE & INDICATION STYLE
Float diagnostics is a safety feature which indicates a contrasting color on the visual indicator when the float has fallen below the lowest measurable point on the scale. This can occur when the specific gravity of the liquid drastically decreases or the float collapses due to a pressure spike.
Only available with stainless steel indicator, refer to digit 19.➀ ➁
CHAMBER CODE
INDICATOR HOUSING MATERIAL & MEASURING SCALE ➀
1 2" S10 digit 21 = 2, B, D
2 2" S40
3 21⁄2" S10
4 21⁄2" S40
5 21⁄2" S80
A 3" S10
B 3" S40
C 3" S80
Codes listed are valid for metallic construction (refer to digit 5).
Wide View Stainless Steel indicator
A Foot / Inch Measurement
M Meter / Centimeter Measurement
C Running Inch Measurement
D Percent (0 - 100%) Measurement
E Gallon Measurement
G Meter / Millimeter Measurement
H Foot / Inch with Percent (Dual Scale)
J Meter / Millimeter with Percent (Dual Scale)
F Liter Measurement
P No scale
Anodized Aluminum Housing
1 Foot / Inch Measurement
3 Running Inch Measurement
4 Percent (0 - 100%) Measurement
5 Gallon Measurement
6 Liter Measurement
7 Meter / Millimeter Measurement
8 Meter / Centimeter Measurement
N No scale
Aluminum indicator with glass window is required if the process operating temperature exceeds 800 F (427 C)
21-22 FLOAT CODE
Codes listed are valid for metallic construction (refer to digit 5).
Total level measurement Consult factory for operating S.G. and/or pressure/temperature rating not covered by the table and graphs.
Float types 2 and B (digit 21) cover full 150 # and PN 16 rating of carbon steel and 316/316L SST flanges up to 315 °C (600 °F).
Float type D (digit 21) covers full 300 # rating of 316/316L SST flanges up to 315 °C (600 °F) and of carbon steel flanges up to 200 °C (400 °F).
Float type D (digit 21) covers full PN 25 and PN 40 rating of carbon steel and 316/316L SST flanges up to 315 °C (600 °F).
Pressure rating of floats (see graphs for full pressure drop details):
type 2: max. 23.0 bar @ 40 °C (333 psi @ 100 °F), max. 18.6 bar @ 315 °C (270 psi @ 600 °F);
hydrotest pressure: 27.6 bar @ 40 °C (400 psi @ 100 °F).
type B: max. 34.5 bar @ 40 °C (500 psi @ 100 °F), max. 15.1 bar @ 315 °C (219 psi @ 600 °F);
hydrotest pressure: 41.4 bar @ 40 °C (600 psi @ 100 °F).
type D: max. 74.7 bar @ 40 °C (1083 psi @ 100 °F), max. 32.6 bar @ 315 °C (473 psi @ 600 °F);
hydrotest pressure: 89.6 bar @ 40 °C (1300 psi @ 100 °F).
Chamber rating 150 #, PN 16, PN 25 ➀ 300 #, 600 #, PN 25, PN 40, PN 63, PN 100
Float mat. 316 SST Ti ➁ Ti ➁
Oper. S.G. Code ➂ Code ➂ Code ➂
0,55 - 0,64 — BE -
0,65 - 0,74 — BE DE
0,75 - 0,84 2C BB DC
0,84 - 0,94 2B BB DB
0,95 - 1,04 2B BB DB
➀ Float types 2 and B (digit 21) do not cover full PN 25 rating of flanges in some cases; check the application data (pressure/temperature) with the float graphs before selecting one of these floats.
➁ Titanium float is factory default
➂ Code 99 is used for special float. Depending on the application a factory assigned code different from the listed ones is possible.
Interface level measurement 99 Special float
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Model:
Digit:
X = product with a specific customer requirement
Digit:
X = product with a specific customer requirement
23-25 VISUAL INDICATION LENGTH
Process temperature: °C (°F)
Float type 2
Process temperature: °C (°F)
Float type D
Process temperature: °C (°F)
Float type B
Pr oc es s p re ss ur e:
b ar
(p sig
Pr oc es s p re ss ur e:
b ar
(p sig
Pr oc es s p re ss ur e:
b ar
(p sig
X X X Specify in INCHES (maximum = 212) when model code 2 is E
Specify in CENTIMETERS (maximum = 538) when model code 2 is M
Example #1: Center-to-Center is 84 inches. Enter as 084. (model digit 2 must be “E”)
Example #2: Center-to-Center is 124 centimeters. Enter as 124. (model digit 2 must be “M”)
Example #3: Center-to-Center is 124.25 inches. Enter as 124 inches and X the model for 124.25 inches. Consult factory for assistance.
Example #4: Center-to-Center is 724 millimeters. Enter as 072 centimeters and X the model for 724 millimeters. Consult factory for assistance.
1 2
T 3 4 5 6
N
A 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
1 Top Mount Atlas™ Magnetic Level Indicator
1 PRODUCT NAME
E English (inches) M Metric (cm)
2 UNIT OF MEASUREMENT
Connection orientation Chamber top Chamber bottom T Top Mount Threaded cap Flanged process connection
3 MOUNTING CONFIGURATION & CHAMBER CONSTRUCTION
Model:
Digit:
X = product with a specific customer requirement
MODEL NUMBER - TOP MOUNT ATLAS
A
B C
A
B
A
B
A
B
Face to Face
C
C
Visual Indication Range
B
Center-to-Face
Visual Indication Range
Visual Indication Range
Visual Indication Range
Visual Indication Range
Visual Indication Range
Face to Face
Center to
Center
Center to
Center
Center to
Center
Visual Indication Range
B
Center-to-Face
A
Center to Face
Visual Indication Range
A
Center to Face
Visual Indication Range
BATON ROUGE, LA
PHONE 1-225-906-2343
F AX 1-225-906-2344
WWW.ORIONINSTRUMENTS.COM
A
B
C C
C
C
C C
A
B C
Visual Indication Range
1/2 Indication Range
1/2 Indication Range
BATON ROUGE, LA
PHONE 1-225-906-2343
F AX 1-225-906-2344
WWW.ORIONINSTRUMENTS.COM
Top Mount
A 150# ASME
B 300# ASME
C 600# ASME
D 900# ASME
E 1500# ASME
F 2500# ASME
4 CHAMBER/FLANGE RATING
A 316/316L stainless steel chamber
B 316/316L stainless steel chamber with carbon steel fittings & flanges
Q Hastelloy C-276
5 MATERIAL OF CONSTRUCTION
N No chamber flange
7 CHAMBER FLANGE(S) TYPE
6 CONSTRUCTION GRADE
Metallic construction – Non-PED
1 Industrial Grade (standard)
2 ASME B31.1 for Power Piping Standard
3 ASME B31.3 for Process Piping Standard �
4 Industrial Grade with NACE MR0175/0103
6 ASME B31.3 and NACE MR0103/0175 �
Metallic construction – PED
D NACE MR0175/MR0103
E ASME B31.3 & NACE MR0175/MR0103 �
J Industrial
Z ASME B31.3 �
A ASME RF slip-on flange (machined)
8 PROCESS CONNECTION TYPE
➀ Consult factory if ASME B31.3 certification is required on carbon steel constructions with design temperatures below -17 °C (0 °F).
1 2 3 4 5 6 7 8 9
N
N
N
N
N
N 15 16 17 18 19 20 21 22 23 24 25
Model:
Digit:
X = product with a specific customer requirement
1 2” S10
2 2” S40
A 3” S10
B 3” S40
C 3” S80
D 3” S160
E 4” S10
F 4” S40
G 4” S80
H 4” S160
9 CUSTOMER NOZZLE SIZE
N None
10 GASKET STYLE
N None
13 VENT TYPE
11 CHAMBER BOLTING MATERIAL
N None
14 DRAIN SIZE
N None
12 VENT SIZE
N None
15 DRAIN TYPE
N None
16 CHAMBER MODIFICATION FOR MOUNTING OF OPTIONAL SWITCHES AND/OR TRANSMITTER
ATLAS can be combined with various externally mounted accessories, including switches and transmitters. In these cases minor changes to the chamber and float design may be required.
For digit 16, match up the MLI product with the appropriate transmitter, switch or combination of both.
For OES/ORS switch, refer to the switch selection data for temperature limitations and insulation options. Match up the switch model code digit 7 with the MLI model codes 16 and 17.
For OCT transmitter, refer to OCT information for temperature limitations and match up the OCT model code with the MLI model codes 16 and 17.
For Jupiter transmitter, refer to JM4 information for temperature limitations and possible mounting configurations.
Match up the Jupiter model code with the MLI model codes 16 and 17.
All transmitters and switches must be ordered separately.
Switch only (no transmitter)
Y OES or ORS switch(es) clamp mounted to chamber
Z OES or ORS switch(es) attached to switch mount rod
Jupiter magnetostrictive transmitter with at least one OES or ORS switch
Mounting of Jupiter
Mounting of switches clamp mounted to chamber attached to switch mount rod
Top mount without offset A ➀ L ➁ ➂
Top mount offset, with or without high temperature bend B M ➂
Bottom mount offset, with or without high temperature bend C P ➂
OCT reed chain transmitter (no switches)
8 Top mount
9 Bottom mount
N No switch or transmitter added
➀ Jupiter: max. 79 to 454 °C (175 to 850 °F) with insulation
➁ Jupiter: max. 79 to 454 °C (175 to 850 °F) with insulation (digit 17 = A, C)
➂ Available when digit 17 = A, B, C or D
Jupiter magnetostrictive transmitter only (no switches)
1 Top mount without offset
2 Top mount offset, with or without high temperature design
3 Bottom mount offset, with or without high temperature design
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Digit:
X = product with a specific customer requirement
➀ Matches external mount Jupiter with digit 3 = E, F, H ➁ Matches external mount Jupiter with digit 3 = K, L, M
Insulation pad for indicator and transmitter
E Indicator only digit 16 = N, Y 121 °C (250 °F) < T ≤ 260 °C (500 °F)
F Indicator only digit 16 = N 261 °C (501 °F) < T ≤ 537 °C (1000 °F)
U Transmitter only digit 16 = 1, 2, 3, A, B, C ➀ digit 16 = 8, 9 79 °C (175 °F) < T ≤ 260 °C (500 °F) 93 °C (200 °F) < T ≤ 260 °C (500 °F)
R Indicator & transmitter digit 16 = 1, 2, 3, A, B, C ➀ digit 16 = 8, 9 121 °C (250 °F) < T ≤ 260 °C (500 °F) 121 °C (250 °F) < T ≤ 260 °C (500 °F)
K Transmitter only digit 16 = 1, 2, 3, A, B, C ➁ & digit 18 = N 261 °C (501 °F) < T ≤ 454 °C (850 °F)
V Indicator & transmitter digit 16 = 1, 2, 3, A, B, C ➁ 261 °C (501 °F) < T ≤ 454 °C (850 °F)
17 INSULATION OPTIONS
N None Indicator: max. 121 °C (250 °F) OCT transmitter: max. 93 °C (200 °F) Jupiter transmitter: max. 79 °C (175 °F)
Total level
1 Orange / black metal flags
2 Yellow / black metal flags
3 Red / white metal flags (standard)
4 Red / silver metal flags +371 °C (+700 °F) and above
N No indicator (For external use of external Jupiter mount only)
18 MEASUREMENT TYPE & INDICATION STYLE
19 INDICATOR HOUSING MATERIAL & MEASURING SCALE ➀
Wide View Stainless Steel indicator
A Foot / Inch Measurement
M Meter / Centimeter Measurement
C Running Inch Measurement
D Percent (0 – 100%) Measurement
P No scale
Anodized Aluminum Housing
1 Foot / Inch Measurement
8 Meter / Centimeter Measurement
N No scale
� Aluminum indicator with glass window is required if the process operating temperature exceeds +800° F (+427° C).
➀ Stilling well is recommended for indicator length of 122 cm (48") or greater
➁ Not available when digit 5 = B or digit 9 = 1, 2
➂ Not available when digit 9 = 1, 2
➃ Not available when digit 5 = B or digit 9 = 1, 2, C, D
➄ Not available when digit 9 = 1, 2, C, D
➅ Not available when digit 5 = B or digit 9 = 1, 2, A, B, C, D, H
➆ Not available when digit 9 = 1, 2, A, B, C, D, H
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Model:
Digit:
X = product with a specific customer requirement
20 STILLING WELL SIZE �
1 2" S10 �
2 2" S40 �
3 21⁄2" S10 �
4 21⁄2" S40 �
A 3" S10 �
B 3" S40 �
N None
23-25 VISUAL INDICATION LENGTH
X X X Specify in INCHES (maximum = 212) when model code 2 is E
Specify in CENTIMETERS (maximum = 538) when model code 2 is M
Example #1: Center-to-Center is 84 inches. Enter as 084. (model digit 2 must be “E”)
Example #2: Center-to-Center is 124 centimeters. Enter as 124. (model digit 2 must be “M”)
Example #3: Center-to-Center is 124.25 inches. Enter as 124 inches and X the model for 124.25 inches. Consult factory for assistance.
Example #4: Center-to-Center is 724 millimeters. Enter as 072 centimeters and X the model for 724 millimeters. Consult factory for assistance.
21 22FLOAT DIAMETER (Consult Factory) FLOAT LENGTH (Consult Factory)
9 Custom
D 2"
8 21⁄4"
K 21⁄2"
L 3"
9 Custom
A 6"
B 8"
C 10"
D 12"
E 14"
6 Plastic Atlas™ Magnetic Level Indicator
1 PRODUCT NAME
E English (inches) M Metric (cm)
2 UNIT OF MEASUREMENT
Connection orientation Chamber top Chamber bottom 1 Side / Side End Cap Flange 2 Side / Side Flange End Cap 3 Side / Side Flange Flange
3 MOUNTING CONFIGURATION & CHAMBER CONSTRUCTION
Model:
Digit:
X = product with a specific customer requirement
MODEL NUMBER - PLASTIC ATLAS
A 150#
4 CHAMBER/FLANGE RATING
1 PVC
2 CPVC
3 KYNAR
4 POLYPROPYLENE
5 FIBERGLASS
5 MATERIAL OF CONSTRUCTION CHAMBER FLANGE(S) TYPE
6 CONSTRUCTION GRADE
1 Industrial Grade (standard)
P Full Face Socket Flange ➀
Q Serrated Face Socket Flange ➁
➀ Available when 5th digit = 1, 2, 3, 4 ➁ Available when 5th digit = 5
Table 1
Maximum Design Pressure: PSI [Bar] vs Temperature
Design Temperature
°F (°C)
Digit 5
1 2 3 4
PVC CPVC KYNAR PP
73 (23) 150 [10.34] 150 [10.34] 140 [9.65] 20 [1.38]
80 (27) 150 [10.34] 150 [10.34] 133 [9.17] 19 [1.31]
90 (32) 150 [10.34] 150 [10.34] 122 [8.41] 18 [1.24]
100 (38) 124 [8.55] 124 [8.55] 112 [7.72] 17 [1.17]
110 (43) 100 [6.89] 100 [6.89] 105 [7.24] 16 [1.10]
115 (46) 90 [6.21] 90 [6.21] 99 [6.83] 15 [1.03]
120 (49) 80 [5.52] 80 [5.52] 95 [6.55] 15 [1.03]
125 (52) 70 [4.83] 70 [4.83] 92 [6.34] 14 [.97]
130 (54) 60 [4.14] 60 [4.14] 87 [6.00] 14 [.97]
140 (60) 44 [3.03] 44 [3.03] 81 [5.58] 13 [.90]
150 (66) N.R. N.R. 73 [5.03] 11 [.76]
160 (71) N.R. N.R. 69 [4.78] 10 [.69]
170 (77) N.R. N.R. 63 [4.34] 5 [.34]
180 (82) N.R. N.R. 59 [4.07] N.R.
200 (93) N.R. N.R. 50 [3.45] N.R.
210 (99) N.R. N.R. 46 [3.17] N.R.
240 (116) N.R. N.R. 35 [2.41] N.R.
280 (138) N.R. N.R. 25 [1.72] N.R.
N.R. = Not Recommended
- Interpolation is permitted
- Fiberglass ratings not listed since they are application specific
1 Van Stone Socket Flange ➀
2 Full Face Socket Flange ➁
3 Serrated Face Socket Flange ➂
8 PROCESS CONNECTION TYPE
➀ Available when 5th digit = 1, 2 ➁ Available when 5th digit = 1, 2, 3, 4 ➂ Available when 5th digit = 5
A 1⁄2" Flange
B 3⁄4" Flange
C 1" Flange
D 11⁄2" Flange
E 2" Flange
9 PROCESS CONNECTION SIZE
N None (if mating flanges are not supplied)
P EPDM Rubber (+93 °C / +200 °F maximum) ➀
Q Neoprene Rubber (+121 °C / +250 °F maximum) ➀
R Buna-N Nitrile Rubber (+121 °C / +250 °F maximum) ➀
S ePTFE soft ring (+232 °C / +450 °F maximum) ➀
T VITON® (+149 °C / +300 °F maximum) ➀
10 GASKET STYLE FOR CHAMBER FLANGE(S)
➀ Temperature limitations are primarily based on plastic construction.
Digit:
X = product with a specific customer requirement
N None
A 304 Stainless steel class 2 A193 Gr. B8 Class 2 / A194 Gr. 8
S Zinc-plated Alloy Steel (+210 °C (+390 °F)) A193 Gr B7 / A194 Gr 2H
11 CHAMBER BOLTING MATERIAL
12 VENT SIZE
N None
1 1⁄2" ➀
2 3⁄4" ➀
13 VENT TYPE
N None
1 Threaded NPT-F (female) with plug
➀ Not Available when 5th digit = 3, 4
14 DRAIN SIZE
N None
1 1⁄2" ➀
2 3⁄4" ➀
15 DRAIN TYPE
N None
1 Threaded NPT-F (female) with plug
16 CHAMBER MODIFICATION FOR MOUNTING OF OPTIONAL SWITCHES AND/OR TRANSMITTER
Atlas can be combined with various externally mounted accessories, including switches and transmitters. In these cases minor changes to the chamber and float design may be required.
For digit 16, match up the MLI product with the appropriate transmitter, switch or combination of both.
For OES/ORS switch, refer to the switch selection data for temperature limitations and insulation options. Match up the switch model code digit 7 with the MLI model codes 16 and 17.
For OCT transmitter, refer to OCT information for temperature limitations and match up the OCT model code with the MLI model codes 16 and 17.
For Jupiter transmitter, refer to JM4 information for temperature limitations and possible mounting configurations.
Match up the Jupiter model code with the MLI model codes 16 and 17.
All transmitters and switches must be ordered separately.
Switch only (no transmitter)
Y OES or ORS switch(es) clamp mounted to chamber
Jupiter magnetostrictive transmitter with at least one OES or ORS switch
Mounting of Jupiter Mounting of switches -clamp mounted to chamber
Top mount without offset ➀ A
Top mount offset, with or without high temperature bend B
Bottom mount offset, with or without high temperature bend C
OCT reed chain transmitter (no switches)
8 Top mount
9 Bottom mount
N No switch or transmitter added
➀ Available only in combination with digit 3 = 1 and digit 13 = N or 1
Jupiter magnetostrictive transmitter only (no switches)
1 Top mount without offset ➀
2 Top mount offset, with or without high temperature design
3 Bottom mount offset, with or without high temperature design
17 INSULATION OPTIONS – See Plastic Temperature Limitations
N None
1 Orange / Black flags
2 Yellow / Black flags
3 Red / White flags
18 MEASUREMENT TYPE & INDICATION STYLE
Digit:
X = product with a specific customer requirement
20 CHAMBER CODE
8 2" S80
19 INDICATOR HOUSING MATERIAL & MEASURING SCALE
Wide View Stainless Steel
A Foot / Inch Measurement
M Meter / Centimeter Measurement
C Running Inch Measurement
D Percent (0 - 100%) Measurement
P No scale
Anodized Aluminum
N No scale
1 Foot / Inch Measurement
8 Meter / Centimeter Measurement
23-25 VISUAL INDICATION LENGTH
X X X Specify in INCHES (maximum = 212) when model code 2 is E
Specify in CENTIMETERS (maximum = 538) when model code 2 is M
Example #1: Center-to-Center is 84 inches. Enter as 084. (model digit 2 must be “E”)
Example #2: Center-to-Center is 124 centimeters. Enter as 124. (model digit 2 must be “M”)
Example #3: Center-to-Center is 124.25 inches. Enter as 124 inches and X the model for 124.25 inches. Consult factory for assistance.
Example #4: Center-to-Center is 724 millimeters. Enter as 072 centimeters and X the model for 724 millimeters. Consult factory for assistance.
21 FLOAT DIAMETER
1 1 7⁄8"
9 Custom
22 FLOAT LENGTH
B 8" Minimum S.G.: 1.11
C 10" Minimum S.G.: 0.89
D 12" Minimum S.G.: 0.74
9 Custom
OPTIONAL EXTERNAL MOUNT LEVEL TRANSMITTERS
The Jupiter transmitter is a magnetostrictive level transmitter while the OCT transmitter is a reed chain level transmitter.
Both types are mounted to the MLI via clamps.
Jupiter Model JM4 magnetostrictive transmitter
SELECTION DATA
9 HOUSING
1 Aluminum, Dual-Compartment
2 316 SS, Dual-Compartment
10 CONDUIT CONNECTION & SUNSHADE OPTION
0 1⁄2” NPT
1 M20
2 1/2” NPT with Sunshade
3 M20 with Sunshade
0 None required for FOUNDATION fieldbus™
1 SIL 2 Hardware �
6 SAFETY OPTIONS
7 ACCESSORIES/MOUNTING
0 No Digital Display and Keypad- Integral
1 No Digital Display and Keypad - Remote 36” (0.91m) �
2 No Digital Display and Keypad - Remote 144” (3.6m) �
A Digital Display and Keypad - Integral
B Digital Display and Keypad - Remote 36” (0.91m) �
C Digital Display and Keypad - Remote 144” (3.6m) �
5 SIGNAL OUTPUT
1 4-20 mA with HART
2 Foundation fieldbus™ Communications
8 AREA CLASSIFICATION
0 General Purpose, Weatherproof (IP 67)
1 Intrinsically Safe / FISCO (cFMus)
3 Explosion-Proof / FNICO (cFMus)
A Intrinsically Safe (ATEX & IEC)
B Flame-Proof (ATEX & IEC)
C Ex n (ATEX & IEC)
D Dust Ex (ATEX & IEC)
1 FISCO Field Device (cFMus)
3 Explosion-Proof & FNICO Field Device (cFMus)
� 3rd Party FMEDA report available � Remote-mount transmitter not available with XP / Flame Proof approvals
FLOAT
Probe mounting positions on Aurora® MLI Probe proximity to the float is critical
Probe mounting positions on Atlas™, Vector™, and Gemini™ Magnetic Level Indicators
J
M
4 5 6 7 8 9 10
Model:
Digit:
E STANDARD Top Mount suitable for process temperatures -40 to +260 °C
(-40 to +500 °F) F STANDARD Top Mount Offset
H STANDARD Bottom Mount Offset
R CRYOGENIC Top Mount suitable for process temperatures -196 to +66 °C
(-320 to +150 °F) S CRYOGENIC Top Mount Offset
T CRYOGENIC Bottom Mount Offset
K HIGH-TEMP Top Mount suitable for process temperatures +501 to +850 °F
(+261 to +454 °C) L HIGH-TEMP Top Mount Offset
M HIGH-TEMP Bottom Mount Offset
3 CONFIGURATION
2 MEASUREMENT SYSTEM
A English Probe length to be provided in inches
C Metric Probe length to be provided in centimeters
4–5 MOUNTING SIDE
00 Left-Side MLI Mount
01 Right-side MLI Mount
6 PROBE MATERIAL OF CONSTRUCTION
A Powder-Coated Aluminum Sensor Enclosure with 316 SS Probe (Available only with Digit 3, Options F, H, L, M)
1 316 SS Sensor Enclosure with 316 SS Probe
7 PROBE OPTIONS
N None
V Vibration-resistant probe mounting
9 UNUSED
0 None
8 CHAMBER SIZE (FOR MOUNTING HARDWARE)
Select these options if chamber DOES NOT contain high-temp insulation
1 2" (or if digit 20 of MLI model code is 1, 2, or 7)
2 21⁄2" or if digit 20 of MLI model code is 3, 4, 5, or 6)
3 3" (or if digit 20 of MLI model code is A, B, C, or D)
4 4" (or if digit 20 of MLI model code is E, F, G, H, or J)
5 3⁄4" (for Atlas Top Mount Configuration only)
0 None. No mounting clamps required.
Select these options if chamber DOES contain high-temp insulation
E 2" (or if digit 20 of MLI model code is 1, 2, or 7)
F 21⁄2" or if digit 20 of MLI model code is 3, 4, 5, or 6)
G 3" (or if digit 20 of MLI model code is A, B, C, or D)
H 4" (or if digit 20 of MLI model code is E, F, G, H, or J)
J 3⁄4" (for Atlas Top Mount Configuration only)
0 None. No mounting clamps required.
00 None
11–12 UNUSED
10 LEVEL/INTERFACE MEASUREMENT PREFERENCE
1 Measure Only the Total Liquid Level
2 Measure Only the Interface Level
3 Measure Both Total and Interface Level
Note: Maximum Probe Length = 400 inches (999 cm)
13–15 PROBE LENGTH
Specify required insertion length (see below)
XXX
Example: 87 inches = 087 Code 2 must be "A"
Example: 120 centimeters = 120 Code 2 must be “C”
Top Mount Configuration Probe Length = Center-to-Center + 8 in. (20 cm)
Top/Bottom Mount Offset Configuration Probe Length = Center-to-Center + 6 in. (15 cm)
Jupiter Model JM4 magnetostrictive external mount probe
SELECTION DATA
1 2 3 4
5 11
6 127 8 13
9 1410 15
Model:
Digit:
OPTIONAL EXTERNAL MOUNT LEVEL TRANSMITTERS
OCT reed chain transmitter The OCT analog transmitter mounts directly to the side of the MLI and provides a continuous 4–20 mA output signal proportional to the liquid level. Using simple and reliable reed switches surface mounted to a printed circuit board, the unit provides a resolution of ± 13 mm (0.50"). Activated by the magnetic field of the float, the transmitter is totally non-invasive.
SELECTION DATA
O
C
T 3 4 5 6 7 8 9 10
Model:
Digit:
X = product with a specific customer requirement
1-3 BASIC MODEL NUMBER
OCT Reed chain transmittter (FM/CSA explosion proof)
4 HOUSING / CABLE ENTRY
A IP 66, cast aluminum, 1⁄2" NPT-F cable entry
S IP 66, 316 stainless steel, 3⁄4" NPT-F cable entry
5 MOUNTING POSITION
A Top mount, right hand
B Top mount, left hand
C Bottom mount, right hand
D Bottom mount, left hand
7 UNIT OF MEASUREMENT
M Metric (cm)
E English (inches)
6 CHAMBER MOUNTING CODE
No insulation present on MLI (MLI model code digit 17 = N)
1 MLI model code digit 20 = 1, 2 MLI model code digit 3 ≠ T
2 MLI model code digit 20 = 3, 4, 5, 6 MLI model code digit 3 ≠ T
3 MLI model code digit 20 = A, B, C, D MLI model code digit 3 ≠ T
4 MLI model code digit 20 = E, F, G, H, J MLI model code digit 3 ≠ T
5 MLI is a top mount design MLI model code digit 3 = T
MLI with high temperature insulation (MLI model code digit 17 = U, R)
E MLI model code digit 20 = 1, 2 MLI model code digit 3 ≠ T
F MLI model code digit 20 = 3, 4, 5, 6 MLI model code digit 3 ≠ T
G MLI model code digit 20 = A, B, C, D MLI model code digit 3 ≠ T
H MLI model code digit 20 = E, F, G, H, J MLI model code digit 3 ≠ T
J MLI is a top mount design MLI model code digit 3 = T
8-10 MEASURING LENGTH -
specify per cm (0.39") increment
030 Min 30 cm (12")
500 503 cm (198") FM approval
500 503 cm (198") CSA approval
Match measuring length with visual indication length of MLI.
Sensor length = measuring length + 20 cm (8").
DIMENSIONS mm (inches) dead zone 100 (4.00) dead zone 100 (4.00)
(5.30)
(4.50)
(4.50)
(5.80)
Measuring length (active span)
Aluminum housing Stainless steel housing
OES bi-stable DPDT microswitch The OES level switch is actuated by simple magnetic coupling. As the liquid level moves, the MLI float (with its internal magnets and flux rings) follows. When the float moves into the proximity of the microswitch, the switch magnet interacts with the float’s magnetic field actuating the switch. The bi-stable design of the switch ensures that it will not reset until the float passes the switch in the opposite direction.
SELECTION DATA
OPTIONAL POINT LEVEL SWITCHES
The OES level switch is a cam-operated microswitch while the ORS level switch is a hermetically sealed reed switch. Both types can be mounted to the MLI either via clamps or attached to a switch mount rod and are field adjustable. Simply loosen the mounting clamps and position at the desired location. Ensure that the switch always remains in close proximity to the internal float.
A switch mount rod is an available alternative method for mounting the switch to an MLI when chamber insulation blanket is present. The rod assembly, which is welded to the MLI chamber, allows the switch to slide along the full length. When the desired position is selected, simply tighten it in place.
OES switch attached to switch mount rod ORS switch attached to switch mount rod
FLOAT
FLOAT
O
E
S 3 4 5 6 7
Model:
Digit:
X = product with a specific customer requirement
DIMENSIONS
mm (inches)
(3.00)
(5.50)
(8.45)
1-3 BASIC MODEL NUMBER
O E S DPDT microswitch
4 HOUSING / CABLE ENTRY
A IP66, cast aluminum, 3⁄4" NPT-F cable entry (2 entries - 1 plugged)
S IP66, 316 stainless steel, 3⁄4" NPT-F cable entry (2 entries - 1 plugged)
5 APPROVAL
N Weatherproof
1 FM/CSA explosion proof
6 CHAMBER MOUNTING CODE
N No mounting clamps
1 MLI model code digit 20 = 1 or 2 (2" chamber)
2 MLI model code digit 20 = 3, 4, 5 or 6 (21⁄2" chamber)
3 MLI model code digit 20 = A, B, C or D (3" chamber)
4 MLI model code digit 20 = E, F, G, H or J (4" chamber)
5 MLI model code digit 3 = T (top mount design (3⁄4" chamber))
7 MOUNTING
C Clamp mounted to chamber T ≤ 121 °C (250 °F)
P Clamp mounted to chamber with insulation pad 121 °C (250 °F) < T ≤ 260 °C (500 °F)
R Attached to switch mount rod T ≤ 260 °C (500 °F)
When Digit 7 = R
W…
This is the start of the file's text. The full file is on GovTribe.