This document is a federal contract solicitation from the Department of the Army National Guard for Optometry Equipment. The solicitation is for a firm-fixed-price contract to purchase the following products: Zeiss ATLAS 500 Corneal Topographer or equal, Zeiss PC Workstation with pre-installed ATLAS 500 Operator Software or equal, Zeiss Instrument Table IT 1060.I with Monitor Bracket or equal, and Zeiss Sliding Keyboard Tray or equal. The total quantity required is 1 of each item. This is a small business set-aside solicitation with a North American Industry Classification System (NAICS) code of 334510. Quotes are due by September 13, 2024 at 2:00 pm EST and will be evaluated on price alone. The government reserves the right to evaluate any "equal" products against the provided technical specifications to determine acceptability. Funds are not yet available for this acquisition, so no contract award will be made until appropriated funds become available.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
The ZEISS ATLAS 500 is optimized for integration into the ZEISS medical ecosystem.
The ZEISS FORUM connectivity enables patient data export, including PDF reports, to optimize your workflow.
Digital documentation.
Speed up practice workflow with less manual errors.
ATLAS 9000 data import
Simply import ZEISS ATLAS 9000 data, continue to review past recordings and compare to the latest recordings without having to switch between old and new systems. Upgrading and transitioning your ZEISS corneal topographer has never been easier.
Reports and data export
Store images, videos and reports within the ZEISS ATLAS 500 acquisition and analysis software, or directly send PDF reports to ZEISS FORUM, without the need for manual data transfer.
Multi-modality worklists in FORUM
Link up ZEISS ATLAS 500 with
ZEISS FORUM and schedule patients via modality worklists to speed up patient throughput. If required, patient data can also be entered via the ZEISS ATLAS 500 acquisition and analysis suite and transferred to ZEISS FORUM.
Technical specifications ZEISS ATLAS 500 Corneal Topographer
Key Parameters
Placido rings 24
Measurement points 6144
Topographic covering (in 42.2D) 9.3 mm
Dioptric range up to 95D
Accuracy Type A (ISO 19980 / ANSI Z80.23, ISO 10343)
Measurement head position Straight, +/- 15° swivel-out
Working distance 74 mm
Adjustment range instrument base (W x H x D) 110 mm x 30 mm x 110 mm
Light sources Placido Fluorescence stimulation Pupillometry
White light LED 450-650 nm LED 465 nm LED 950 nm
Dimensions (W x H x D) 319 mm x 504 mm (+/- 15 mm) x 420 mm
Weight of measurement head 12.2 kg
Power supply 100 V to 240 V AC 50/60 Hz
Data transfer USB 3.0
Compatibility with standard DICOM
ATLAS Software – Technical Hardware Requirements
Processor Intel® Core™ i7 6th generation or higher
SSD capacity 250 GB
RAM 16 GB
Recommended HDD capacity 2 TB
Interface 1x USB 3.0 3x USB 2.0 or higher
LAN
Monitor resolution 1,920 x 1,080 pixels (Full-HD) Scaling 100%
Recommended monitor size 22” (15” minimum)
Operating system Windows 10 x 64 Professional or higher
Data export formats PDF (report)
ZEISS PC Workstation - 22" Touch Screen Monitor Including: PC Mouse, PC Keyboard
Dimensions (W x H x D) 546 mm x 351 mm x 66 mm
Weight Approx. 8 kg
Monitor resolution 1,920 x 1,080 pixels LCD touch screen
Processor Intel® Core™ i5/i7 Quad Core Processor
Hard disc 2 TB HDD
RAM 16 GB
Interfaces 4x USB 3.0 2x Isolated Ethernet Port 2x RS-232
1x HDMI and Display Port Audio (Mic-in/Line-out)
Corneal Topography
Views Axial/sagittal curvature Tangential curvature Elevation Gaussian map Keratometry
Refractive power Corneal wavefront Point spread function (PSF) Modular transfer function (MTF)
Pupillometry
Static (photopic, mesopic, low mesopic, scotopic)
Dynamic