Atch 4_Design_DrawingsVol2_091319.pdf
PDF 45 MB Posted
- Attached to
- UTTR CMCC at Hill AFB, UT Federal contract opportunity
- Solicitation number
- W91238-19-R-0026
About this file
This document provides details on a federal contract opportunity for construction services. The U.S. Army Corps of Engineers Engineering District Sacramento is soliciting proposals for a firm-fixed price construction contract to build a Consolidated Mission Control Center at Hill Air Force Base in Utah. The project scope involves constructing a new facility to replace outdated air traffic control and mission evaluation facilities at the Utah Test and Training Range. The building is intended to consolidate important functional relationships and adhere to industry standards, applicable codes, and the Hill Air Force Base Design Guide. The estimated value of construction is between $25-100 million. Responses are due under Solicitation Number W91238-19-R-0026. The period of performance is 852 days. A site visit will be scheduled upon release of the solicitation. The small business set-aside aims to award a contract by early 2020.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| CMCC Site Visit Sign In 10-7-2020.pdf | ||
| Atch 2_SpecsVol2_101119.pdf | ||
| Atch 6_CMCC Site Walk 07OCT2020.pdf | ||
| Atch 3_Design_DrawingsVol1_091319.pdf | ||
| Atch 7_Utah Resident Office Map.pdf | ||
| Atch 1_SpecsVol1_101119.pdf | ||
| Atch 5_WDs DB Weber County 8-28-2020.pdf | ||
| SF1442 Final W9123819R0026 UTTR CMCC 24SEP2020.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CIVIL / LANDSCAPE
HOWARD LUSK
STRUCTURAL
BRIAN HORSTMANN
ARCHITECTURAL
BRYAN DYSON
INTERIORS
BRIANA ERNSTING
FIRE ALARM /
FIRE SUPPRESSION
JASON FOULK
PLUMBING / MECHANICAL
JAMES MOLER
ELECTRICAL
OSAMA FARES
TELECOMMUNICATIONS
SCOTT HANSBERRY
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M
AR
K D
ES
C
R
IP
TI
O
N
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
SA
C
R
AM
EN
TO
D
IS
TR
IC
T
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
JA
C
O
BS
D U
LL
ES
C O
R N
ER
P
AR
K, S U
IT
E
H
ER
N D
O N
, V A
U
TA
H T
ES
T
AN
D
T R
AI
N
IN
G
R
AN
G E
(U
TT
R
C O
N
SO
LI
D
AT
ED
M
IS
SI
O
N C
O N
TR
O
L C
EN
TE
R (C
M C
C)
HI
LL
A
IR
F
O
RC
E
BA
SE
, U
TA
H
S
EP
TE
M
BE
R
P2 #3
W
2P P-
-D
-0
PACKAGE 1
TIRAGGA NO.:
LEGACY NO.:
WORK ORDER NO.:
1022042
KRSM123009
54827
G-000
CO
V E
R
SH
EE
T
E.
B
R O
N
ST
EI
N
N . F
R
EY
M . R
AH
M
AN
K.
H
AR
G
R
EA
VE
S
FI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
SACRAMENTO DISTRICT
P2#333029
W912PP-17-D-0010
13 SEPTEMBER 2019
HILL AIR FORCE BASE, UTAH
UTAH TEST AND TRAINING RANGE (UTTR)
CONSOLIDATED MISSION CONTROL CENTER (CMCC)
CORRECTED FINAL (100%) DESIGN SUBMITTAL
G E N
ER
A L
DRAWING INDEX - VOLUME 1 OF 2
SHEET
NUMBER SHEET NAME
SHEET
NUMBER SHEET NAME
SHEET
NUMBER SHEET NAME
SHEET
NUMBER SHEET NAME
SHEET
NUMBER SHEET NAME
SHEET
NUMBER SHEET NAME
DRAWING INDEX - VOLUME 2 OF 2
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
SA
C
R
AM
EN
TO
D
IS
TR
IC
T
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
JA
C
O
BS
D U
LL
ES
C O
R N
ER
P
AR
K, S U
IT
E
H
ER
N D
O N
, V A
U
TA
H
TE
ST
A
N D
T
RA
IN
IN
G R
AN
G
E (U
TT
R)
CO
NS
O
LI
DA
TE
D
M
IS
SI
O
N
CO
NT
RO
L
CE
NT
ER
(C M
CC
HI
LL
A
IR
F O
RC
E
BA
SE
, U
TA
H
S
EP
TE
M
BE
R
P2 #3
W
2P P-
-D
-0
G-001
DR
AW
IN
G
I N
DE
X
E.
B
R O
N
ST
EI
N
N . F
R
EY
M . R
AH
M
AN
K.
H
AR
G
R
EA
VE
S
FI
R
ST
T
IT
LE
SE
C
O N
D T
IT
LE
G E N
ER
A L
BRYAN DYSON
ARCHITECT
LICENSE NO.: ##########
A-612 STOREFRONT AND WINDOW DETAILS
A-613 STOREFRONT AND WINDOW DETAILS
A-614 LOUVER TYPES AND DETAILS
A-701 PARTITION TYPES
A-702 PARTITION TYPES
A-711 PARTITION DETAILS
A-712 PARTITION DETAILS
A-713 PARTITION DETAILS
A-801 SIGNAGE PLAN - OVERALL
A-801a SIGNAGE PLAN - OVERALL - BID OPTION 2 & 3
A-811 SIGNAGE DETAILS
A-812 SIGNAGE TYPES
A-813 SIGNAGE SCHEDULE
INTERIORS
I-101 FINISH FLOOR PLAN - OVERALL
I-101a FINISH FLOOR PLAN - OVERALL - BID OPTION 2 & 3
I-102 FINISH FLOOR PLAN - AREA A
I-102a FINISH FLOOR PLAN - AREA A - BID OPTION 2
I-103 FINISH FLOOR PLAN - AREA B
I-104 FINISH FLOOR PLAN - AREA C
I-104a FINISH FLOOR PLAN - AREA C - BID OPTION 3
I-111 FURNITURE PLAN - OVERALL
I-111a FURNITURE PLAN - OVERALL - BID OPTION 2 & 3
I-112 FURNITURE PLAN - AREA A
I-112a FURNITURE FLOOR PLAN - AREA A - BID OPTION 2
I-113 FURNITURE PLAN - AREA B
I-114 FURNITURE PLAN - AREA C
I-114a FURNITURE FLOOR PLAN - AREA C - BID OPTION 3
SF124 ROOF FRAMING PLAN - AREA C
SF124a ROOF FRAMING PLAN - AREA C - BID OPTION 3
S-201 FRAMING ELEVATIONS
S-202 FRAMING ELEVATIONS
S-203 FRAMING ELEVATIONS
S-204 FRAMING ELEVATIONS
S-205 FRAMING ELEVATIONS
S-501 TYPICAL DETAILS
S-502 TYPICAL DETAILS
S-503 TYPICAL DETAILS
S-504 TYPICAL DETAILS
S-505 TYPICAL DETAILS
S-506 TYPICAL DETAILS
S-507 TYPICAL DETAILS
S-510 SECTIONS & DETAILS
S-521 SECTIONS & DETAILS
S-522 SECTIONS & DETAILS
S-523 SECTIONS & DETAILS
S-524 SECTIONS & DETAILS
ARCHITECTURAL
A-001 GENERAL NOTES
A-101 FLOOR PLAN - OVERALL
A-101a FLOOR PLAN - OVERALL - BID OPTION 2 & 3
A-102 FLOOR PLAN - AREA A
A-102a FLOOR PLAN - AREA A - BID OPTION 2
A-103 FLOOR PLAN - AREA B
A-104 FLOOR PLAN - AREA C
A-104a FLOOR PLAN - AREA C - BID OPTION 3
A-111 REFLECTED CEILING PLAN - OVERALL
A-111a REFLECTED CEILING PLAN - OVERALL - BID OPTION
2 & 3
A-112 REFLECTED CEILING PLAN - AREA A
A-112a REFLECTED CEILING PLAN - AREA A - BID OPTION 2
A-113 REFLECTED CEILING PLAN - AREA B
A-114 REFLECTED CEILING PLAN - AREA C
A-114a REFLECTED CEILING PLAN - AREA C - BID OPTION 3
A-121 ROOF PLAN - OVERALL
A-121a ROOF PLAN - OVERALL - BID OPTION 2 & 3
A-201 EXTERIOR ELEVATIONS - OVERALL
A-201a EXTERIOR ELEVATIONS - OVERALL - BID OPTION 2
& 3
A-202 EXTERIOR ELEVATIONS - PARTIALS - NORTH
A-202a EXTERIOR ELEVATIONS - PARTIALS - NORTH - BID
OPTION 2 & 3
A-203 EXTERIOR ELEVATIONS - PARTIALS - SOUTH
A-203a EXTERIOR ELEVATIONS - PARTIALS - SOUTH - BID
OPTION 2 & 3
A-204 EXTERIOR ELEVATIONS - PARTIALS - EAST & WEST
A-204a EXTERIOR ELEVATIONS - PARTIALS - EAST & WEST
- BID OPTION 2 & 3
A-301 BUILDING SECTIONS
A-301a BUILDING SECTIONS - BID OPTION 2 & 3
A-311 EXTERIOR WALL SECTIONS
A-312 EXTERIOR WALL SECTIONS
A-313 EXTERIOR WALL SECTIONS
A-314 EXTERIOR WALL SECTIONS
A-401 ENLARGED FLOOR PLANS
A-402 INTERIOR ELEVATIONS
A-403 INTERIOR ELEVATIONS
A-411 TOILET ACCESSORIES
A-501 EXTERIOR WALL DETAILS
A-502 EXTERIOR WALL DETAILS
A-503 EXTERIOR WALL DETAILS
A-511 ENLARGED PLAN DETAILS
A-512 ENLARGED PLAN DETAILS
A-513 ENLARGED PLAN DETAILS
A-521 EXTERIOR DETAILS
A-522 EXTERIOR DETAILS
A-531 INTERIOR DETAILS
A-532 INTERIOR DETAILS
A-533 INTERIOR DETAILS
A-534 INTERIOR DETAILS
A-535 INTERIOR DETAILS
A-536 INTERIOR DETAILS
A-537 INTERIOR DETAILS
A-601 ROOM FINISH SCHEDULE
A-602 FINISH MATERIAL LEGENDS
A-603 DOOR SCHEDULE
A-604 DOOR DETAILS
A-605 DOOR DETAILS
A-606 DOOR DETAILS
A-611 STOREFRONT AND WINDOW TYPES
GENERAL
G-000 COVER SHEET
G-001 DRAWING INDEX
G-002 LOCATION MAP / VICINITY MAP
G-003 GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS
G-100 LIFE SAFETY CODE SUMMARY
G-101 LIFE SAFETY PLAN - OVERALL
G-101a LIFE SAFETY PLAN - OVERALL - BID OPTION 2 & 3
G-111 SECURITY ZONE PLAN - OVERALL
G-111a SECURITY ZONE PLAN - OVERALL - BID OPTION 2 &
G-121 AIR BARRIER PLAN AND SECTION
G-121a AIR BARRIER PLAN AND SECTION - BID OPTION 2 &
TOPOGRAPHY
V-100 EXISTING CONDITIONS PLAN
CIVIL
B-001 BORING LOGS
C-001 CIVIL GENERAL NOTES AND LEGEND
C-002 EROSION AND SEDIMENT CONTROL NOTES
C-100 EROSION CONTROL PLAN
C-501 EROSION CONTROL DETAILS
C-900 SITE PHOTOS
CD100 SITE DEMOLITION PLAN
CD101 BUILDINGS 1274 AND 1276 SITE DEMOLITION PLAN
CS100 SITE PLAN - OVERALL
CS101 SITE PLAN - NW
CS102 SITE PLAN - NE
CS103 SITE PLAN - SW
CS104 SITE PLAN - SE
CP100 SIGNING AND MARKING PLAN - OVERALL
CP101 SIGNING AND MARKING PLAN - NW
CP102 SIGNING AND MARKING PLAN - NE
CP103 SIGNING AND MARKING PLAN - SW
CP104 SIGNING AND MARKING PLAN - SE
CP-501 PAVEMENT DETAILS
CP-502 SIGNING AND MARKING DETAILS
CG100 GRADING AND DRAINAGE PLAN OVERALL
CG101 GRADING AND DRAINAGE PLAN - NW
CG102 GRADING AND DRAINAGE PLAN - NE
CG103 GRADING AND DRAINAGE PLAN - SW
CG104 GRADING AND DRAINAGE PLAN - SE
CG105 BUILDING INTERMEDIATE GRADING PLAN
CG-201 STORM SEWER PROFILES
CG-301 SITE SECTIONS
CG-501 STORM DETAILS
CG-502 STORM DETAILS
CU100 OVERALL UTILITY PLAN
CU101 UTILITY PLAN - NW
CU102 UTILITY PLAN - NE
CU104 UTILITY PLAN - SE
CU-201 UTILITY PROFILES
CU-501 UTILITY DETAILS
CU-502 UTILITY DETAILS
LANDSCAPE ARCHITECTURE
LP100 PLANTING PLAN - OVERALL
LP101 ENLARGED PLANTING PLANS
LP501 PLANTING DETAILS
LP502 PLANTING SCHEDULE
STRUCTURAL
S-001 GENERAL NOTES
S-002 GENERAL NOTES
S-003 WIND LOADING DIAGRAM
S-004 SNOW LOADING DIAGRAM
SB101 FOUNDATION PLAN - OVERALL
SB101a FOUNDATION PLAN - OVERALL - BID OPTION 2 & 3
SB102 FOUNDATION PLAN - AREA A
SB102a FOUNDATION PLAN - AREA A - BID OPTION 2
SB103 FOUNDATION PLAN - AREA B
SB104 FOUNDATION PLAN - AREA C
SB104a FOUNDATION PLAN - AREA C - BID OPTION 3
SF121 ROOF FRAMING PLAN - OVERALL
SF121a ROOF FRAMING PLAN - OVERALL - BID OPTION 2 & 3
SF122 ROOF FRAMING PLAN - AREA A
SF122a ROOF FRAMING PLAN - AREA A - BID OPTION 2
SF123 ROOF FRAMING PLAN - AREA B
E-713 PANELBOARD SCHEDULES
E-714 PANELBOARD SCHEDULES
E-715 PANELBOARD SCHEDULES
E-716 PANELBOARD SCHEDULES
E-717 PANELBOARD SCHEDULES
E-718 PANELBOARD SCHEDULES
TELECOMMUNICATIONS
T-001 SYMBOLS, ABBREVIATIONS AND GENERAL NOTES
TS101 TELECOM SITE PLAN
T-100 TELECOM UNDERGROUND CONDUIT PLAN
T-101 TELECOM PLAN - OVERALL
T-101a TELECOM PLAN - OVERALL - BID OPTION 2 & 3
TT102 TELECOM PLAN - AREA A
TT102a TELECOM PLAN - AREA A - BID OPTION 2
TT103 TELECOM PLAN - AREA B
TT104 TELECOM PLAN - AREA C
TT104a TELECOM PLAN - AREA C - BID OPTION 3
TT112 TELECOM BASKET TRAY PLAN - AREA A
TT112a TELECOM BASKET TRAY PLAN - AREA A - BID
OPTION 2
TT113 TELECOM BASKET TRAY PLAN - AREA B
TT114 TELECOM BASKET TRAY PLAN - AREA C
TT122 TELECOM FIBER CABLE TRAY PLAN - AREA A
TT123 TELECOM FIBER CABLE TRAY PLAN - AREA B
TT124 TELECOM FIBER CABLE TRAY PLAN - AREA C
TT133 TELECOM PDS TRAY PLAN - AREA B
TT142 TELECOM UNDERGROUND BLACK CONDUIT PLAN -
AREA A
TT143 TELECOM UNDERGROUND BLACK CONDUIT PLAN -
AREA B
TT144 TELECOM UNDERGROUND BLACK CONDUIT PLAN -
AREA C
TT153 TELECOM UNDERGROUND RED CONDUIT PLAN -
AREA B
TT154 TELECOM UNDERGROUND RED CONDUIT PLAN -
AREA C
TT163 TELECOM UNDERGROUND PDS CONDUIT PLAN -
AREA B
TY102 SECURITY PLAN - AREA A
TY102a SECURITY PLAN - AREA A - BID OPTION 2
TY103 SECURITY PLAN - AREA B
TY104 SECURITY PLAN - AREA C
TY104a SECURITY PLAN - AREA C - BID OPTION 3
T-201 CABINET ELEVATIONS
T-202 CABINET ELEVATIONS
T-203 CABINET ELEVATIONS
T-204 CABINET ELEVATIONS
T-205 CABINET ELEVATIONS
T-206 CABINET ELEVATIONS
T-207 CABINET ELEVATIONS
T-208 CABINET ELEVATIONS
T-209 CABINET ELEVATIONS
T-210 WALL ELEVATIONS
T-211 CABINET CABLE TRAY SECTIONS
T-212 CABINET CABLE TRAY SECTIONS
T-401 ENLARGED TELECOM ROOM PLANS
T-402 ENLARGED TELECOM ROOM PLANS
T-403 ENLARGED TELECOM ROOM PLANS
T-404 ENLARGED TELECOM ROOM PLANS
T-405 ENLARGED TELECOM ROOM PLANS
T-501 SYSTEMS OUTLET DETAILS
T-502 SYSTEMS CABLE TRAY DETAILS
T-503 SYSTEMS CABLE TRAY DETAILS
T-504 GROUNDING DIAGRAM AND DETAILS
TY501 SECURITY DETAILS
TY502 SECURITY EQUIPMENT LIST AND DETAILS
T-601 VOICE AND DATA ONE-LINE DIAGRAM
T-602 3D RED PATHWAY SYSTEM
T-603 3D FIBER PATHWAY SYSTEM
T-604 3D PDS PATHWAY SYSTEM
T-605 3D BLACK PATHWAY SYSTEM
T-606 3D BLACK PATHWAY SYSTEM - BID OPTION 2
P-901 SANITARY WASTE AND VENT ISOMETRIC
P-902 DOMESTIC WATER ISOMETRIC
MECHANICAL
M-001 HVAC LEGEND, ABBREVIATIONS, AND SYMBOLS
M-002 HVAC LEGEND, GENERAL NOTES, AND
ABBREVIATIONS
M-101 HVAC FLOOR PLAN - OVERALL
M-101a HVAC FLOOR PLAN - OVERALL - OPTION 2 & 3
MH102 HVAC FLOOR PLAN - AREA A
MH102a HVAC FLOOR PLAN - AREA A - BID OPTION 2
MH103 HVAC FLOOR PLAN - AREA B
MH104 HVAC FLOOR PLAN - AREA C
MH104a HVAC FLOOR PLAN - AREA C - BID OPTION 3
MP102 HYDRONIC FLOOR PLAN - AREA A
MP102a HYDRONIC FLOOR PLAN - AREA A - BID OPTION 2
MP103 HYDRONIC FLOOR PLAN - AREA B
MP104 HYDRONIC FLOOR PLAN - AREA C
MP104a HYDRONIC FLOOR PLAN - AREA C - BID OPTION 3
M-301 HVAC BUILDING SECTIONS
M-302 HVAC BUILDING SECTIONS
M-401 HVAC ENLARGED PLANS
M-402 HVAC ENLARGED PLANS
M-403 HVAC ENLARGED PLANS
M-501 HVAC DETAILS
M-502 HVAC DETAILS
M-503 HVAC DETAILS
M-601 HVAC SCHEDULES
M-602 HVAC SCHEDULES
M-603 HVAC SCHEDULES
M-701 CHILLED WATER ONE LINE DIAGRAM
M-702 HOT WATER ONE LINE DIAGRAM
M-801 BAS ONE LINE CONTROL DIAGRAMS
M-802 BAS CONTROL DIAGRAMS
M-803 BAS CONTROL DIAGRAMS
M-804 BAS CONTROL DIAGRAMS
M-805 BAS CONTROL DIAGRAMS
M-806 BAS CONTROL POINTS
ELECTRICAL
E-001 GENERAL NOTES AND ABBREVIATIONS
E-002 SYMBOLS
ES101 SITE PLAN
EL101 LIGHTING PLAN - OVERALL
EL101a LIGHTING PLAN - OVERALL - BID OPTION 2 & 3
EL102 LIGHTING PLAN - AREA A
EL102a LIGHTING PLAN - AREA A - BID OPTION 2
EL103 LIGHTING PLAN - AREA B
EL104 LIGHTING PLAN - AREA C
EL104a LIGHTING PLAN - AREA C - BID OPTION 3
EP101 POWER AND EQUIPMENT PLAN - OVERALL
EP101a POWER AND EQUIPMENT PLAN - OVERALL - BID
OPTION 2 & 3
EP102 POWER PLAN - AREA A
EP102a POWER PLAN - AREA A - BID OPTION 2
EP103 POWER PLAN - AREA B
EP104 POWER PLAN - AREA C
EP104a POWER PLAN- AREA C - BID OPTION 3
EP112 EQUIPMENT PLAN - AREA A
EP112a EQUIPMENT PLAN - AREA A - BID OPTION 2
EP113 EQUIPMENT PLAN - AREA B
EP114 EQUIPMENT PLAN - AREA C
EP114a EQUIPMENT PLAN - AREA C - BID OPTION 3
E-201 EQUIPMENT ELEVATIONS
E-401 ENLARGED FLOOR PLANS
E-402 ENLARGED FLOOR PLANS
E-403 ENLARGED FLOOR PLANS
E-501 DETAILS
E-502 DETAILS
E-503 DETAILS
E-504 DETAILS
E-505 DETAILS
E-506 DETAILS
E-601 ONE-LINE DIAGRAM
E-602 ONE-LINE DIAGRAM
E-603 ONE-LINE DIAGRAMS
E-701 LIGHTING SCHEDULES
E-702 LIGHTING SCHEDULES
E-703 EQUIPMENT DATA SCHEDULE
E-704 EQUIPMENT DATA SCHEDULE
E-710 PANELBOARD SCHEDULES
E-711 PANELBOARD SCHEDULES
E-712 PANELBOARD SCHEDULES
FIRE PROTECTION
FS100 FIRE CODE COMPLIANCE SITE PLAN
FIRE ALARM
FA001 GENERAL NOTES, LEGENDS, AND ABBREVIATIONS
FA101 FLOOR PLAN - OVERALL
FA101A FLOOR PLAN - OVERALL BID OPTION 2&3
FA102 FLOOR PLAN - AREA A
FA102A FLOOR PLAN - AREA A - BID OPTION 2
FA103 FLOOR PLAN - AREA B
FA104 FLOOR PLAN - AREA C
FA104A FLOOR PLAN - AREA C - BID OPTION 3
FA501 DETAILS
FA502 DETAILS
FIRE SUPPRESSION
FX001 GENERAL NOTES, LEGENDS, AND ABBREVIATIONS
FX101 FLOOR PLAN - OVERALL
FX101A FLOOR PLAN - OVERALL - BID OPTION 2&3
FX102 FLOOR PLAN - AREA A
FX102A FLOOR PLAN - AREA A - BID OPTION 2
FX103 FLOOR PLAN - AREA B
FX104 FLOOR PLAN - AREA C
FX104A FLOOR PLAN - AREA C - BID OPTION 3
FX501 DETAILS
PLUMBING
P-001 SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES
P-101 FLOOR PLAN - OVERALL
P-101A FLOOR PLAN - OVERALL - BID OPTION 2 & 3
P-102 FLOOR PLAN - AREA A
P-102A FLOOR PLAN - AREA A - BID OPTION 2
P-103 FLOOR PLAN - AREA B
P-104 FLOOR PLAN - AREA C
P-104A FLOOR PLAN - AREA C - BID OPTION 3
P-401 ENLARGED PLAN
P-402 ENLARGED PLAN
P-403 ENLARGED PLAN
P-501 DETAILS
P-601 SCHEDULES
GENERAL
G-000 COVER SHEET
G-001 DRAWING INDEX
CEILING-MOUNTED SPEAKER/STROBE (XX DENOTES CANDELA RATING)
(Y DENOTES LENS COLOR; R=RED, BLANK=CLEAR)
WALL-MOUNTED SPEAKER/STROBE (XX DENOTES CANDELA RATING)
(WP DENOTES WEATHER PROOF DEVICE)
WALL-MOUNTED FIRE ALARM STROBE (XX DENOTES CANDELA RATING)
(WP DENOTES WEATHER PROOF DEVICE)
WALL-MOUNTED SPEAKER (WP DENOTES WEATHER PROOF DEVICE)
H/L
P
WP
FAMN
WP
FIRE ALARM AND MASS NOTIFICATION GENERAL NOTESFIRE ALARM AND MASS NOTIFICATION LEGEND
FIRE ALARM BELL
RADIO ALARM TRANSMITTER
WALL-MOUNTED EXTERIOR WEATHERPROOF SPEAKER
FIRE SERVICE TELEPHONE
HI/LOW AIR PRESSURE SWITCH
PRESSURE SWITCH
SPRINKLER TAMPER SWITCH
SPRINKLER FLOW SWITCH
DUCT SMOKE DETECTOR
PHOTOELECTRIC SMOKE DETECTOR
(P,A INDICATES PREACTION SYSTEM DEVICE)
MANUAL PULL STATION
HEAT DETECTOR
LOCAL OPERATING CONSOLE
NAC EXTENDER PANEL
FIRE ALARM SYSTEM ANNUNCIATOR
FIRE ALARM CONTROL PANEL, COMBINED WITH MASS NOTIFICATION
AUTONOMOUS CONTROL UNIT
AFF
AHJ
AVG
COTR
ELEV
EOL
FPC
MIN
NAC
NIC
NP
NC
SIM
SLC
SQFT
SP
TD
WP WEATHER PROOF
TRAVEL DISTANCE
SMOKE PARTITION
SQUARE FEET
SIGNALING LINE CIRCUIT
SIMILAR
NONCOMBUSTIBLE
NOT PERMITTED
NOT IN CONTRACT
NOTIFICATION APPLIANCE CIRCUIT
MINIMUM
FIRE PUMP CONTROLLER
END OF LINE RESISTOR
ELEVATION
CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE
AVERAGE
ABOVE FINISHED FLOOR
AUTHORITY HAVING JURISDICTION
FIRE ALARM ABBREVIATIONS
CARBON MONOXIDE DETECTORCO
POLE-MOUNTED CONE TYPE EXTERIOR WEATHERPROOF SPEAKER
CIS COMMON INTELLIGIBILITY LEVEL
DOR
AFG ABOVE FINISHED GRADE
DESIGNER OF RECORD
SD SMOKE DAMPER
SMOKE DAMPER
EX EXPLOSION PROOF
FIRE DEPARTMENT KEY LOCK BOX
1. PROVIDE AND INSTALL A COMPLETE COMBINED ADDRESSABLE FIRE ALARM AND MASS NOTIFICATION SYSTEM THROUGHOUT THE FACILITY IN ACCORDANCE WITH NFPA 72 AND AS INDICATED. CIRCUITS USED TO MONITOR AND CONTROL INITIATING DEVICES WILL BE INITIATING DEVICE CIRCUITS (IDC), CLASS B, OR SIGNALING LINE CIRCUITS (SLC), IN ACCORDANCE WITH NFPA 72. NETWORK CIRCUITS BETWEEN FIRE ALARM CONTROL PANELS, SUB PANELS, ANNUNCIATORS, ETC. WILL BE CLASS A IN ACCORDANCE WITH NFPA 72. CIRCUITS USED TO INITIATE OPERATION OF THE NOTIFICATION DEVICES WILL BE NOTIFICATION APPLIANCE CIRCUITS (NAC), CLASS B IN ACCORDANCE WITH NFPA 72. ALL FIRE ALARM CIRCUITS WILL BE MONITORED FOR CIRCUIT INTEGRITY (FAULT, SHORT AND GROUND) BY THE FIRE ALARM CONTROL PANEL. CIRCUIT FAILURE
SIGNALS WILL BE ANNUNCIATED AS TROUBLE SIGNALS.
2. DESIGN, INSTALL AND TEST THE FIRE ALARM/MASS NOTIFICATION SYSTEM IN ACCORDANCE WITH ANGETL 15-01-03, 01 MAY 2015; UFC 1-200-01, 20 JUNE 2016 EDITION; UFC 3-600-01, 10 MAY 2019 WITH CHANGE 3, 25 MARCH 2018; UFC 4-021-01 9 APRIL 2008 WITH CHANGE 1, JANUARY 2010; UFC 4-133-01 01 JUNE 2019 CHANGE 2, DECEMBER 2017, INTERNATIONAL BUILDING CODE, 2015 EDITION; NFPA 1, 2018 EDITION; NFPA 72, 2016 EDITION; NFPA 75, 2017 EDITION; AND NFPA 90A, 2015 EDITION.
3. FOR COMPLETE SYSTEM CONTROL, REFER TO FIRE ALARM LOGIC MATRIX ON SHEET FA501
4. PERFORM ALL ACCEPTANCE AND OPERATIONAL TESTS IN ACCORDANCE WITH NFPA 72.
5. A "RECORD OF COMPLETION", PREPARED IN ACCORDANCE WITH NFPA 72, AND THE FIRE ALARM TEST REPORT TO BE FILED
WITH THE LOCAL FIRE MARSHAL'S OFFICE.
6. THE FLASH RATE OF VISIBLE NOTIFICATION APPLIANCES SHALL NOT EXCEED TWO FLASHES PER SECOND, NOR BE LESS THAN ONE FLASH EVERY SECOND, IN ACCORDANCE WITH NFPA 72. A MAXIMUM PULSE DURATION SHALL BE 0.2 SECONDS WITH A MAXIMUM DUTY CYCLE OF 40 PERCENT, IN ACCORDANCE WITH NFPA 72. VISIBLE NOTIFICATION APPLIANCES SHALL
BE SPACED IN ACCORDANCE WITH NFPA 72 AND AS INDICATED.
7. VISUAL STROBE DEVICES WILL HAVE A MINIMUM 15-CANDELA RATING AND WILL BE LOCATED THROUGHOUT ALL COMMON AREAS OF THE OFFICES SUCH AS LOBBIES AND CORRIDORS. VISUAL DEVICES WILL ALSO BE LOCATED IN ALL TOILET ROOMS, CONFERENCE ROOMS, CLASSROOMS, ASSEMBLY AREAS, BREAK AREAS, ETC., AS REQUIRED FOR COMPLIANCE WITH THE ABA/ADA. CLEAR STROBES MARKED "ALERT" WILL BE USED TO INDICATE FIRE ALARMS AND MASS NOTIFICATION ALARMS IN ACCORDANCE WITH THE REQUIREMENTS OF UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS AND ECB 2018-17.
8. THE SPRINKLER SYSTEM CONTROL VALVE TAMPER AND FLOW SWITCHES SHALL BE CONNECTED TO THE SIGNALING LINE
CIRCUITS. REFER TO FIRE SUPPRESSION DRAWINGS FOR LOCATIONS.
9. OBTAIN APPROVALS FROM THE LOCAL FIRE MARSHAL'S OFFICE PRIOR TO COMMENCING WORK. SUBMIT SHOP DRAWINGS TO THE AHJ FOR APPROVAL. WORK SHALL NOT COMMENCE UNTIL APPROVAL OF THE SHOP DRAWINGS IS RECEIVED FROM THE AHJ. FIRE ALARM SYSTEM SHOP DRAWINGS, AT A MINIMUM, SHALL INCLUDE THE REQUIREMENTS OF NFPA 72, SECTION 7.4, 7.5, AND A.7.4.
10. AUDIBLE FIRE ALARM SOUND LEVEL SHALL BE AT LEAST 15 dBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS, WHICHEVER IS GREATER, MEASURED 5 FEET ABOVE THE FLOOR IN THE OCCUPIABLE AREA, BUT NOT GREATER THAN 120 dBA AT THE MINIMUM HEARING DISTANCE FROM THE AUDIBLE APPLIANCE. PROVIDE ADEQUATE NOTIFICATION APPLIANCES THROUGHOUT THE SPACE TO MEET NFPA
72 REQUIREMENTS.
11. AUDIBLE MASS NOTIFICATION REQUIREMENTS SHALL MEET THE CLARITY LEVELS OF UFC 4-021-01. (0.8 CIS MINIMUM)
12. ANY PENETRATIONS MADE THROUGH FIRE RATED PARTITIONS SHALL BE FIRE STOPPED WITH A U.L. LISTED SYSTEM. SUBMIT
PENETRATION LOCATION TO THE COTR FOR APPROVAL.
13. DUCT SMOKE DETECTORS FOR AIR HANDLING UNITS WILL BE SUPPLIED BY DIVISION 28 AND INSTALLED BY DIVISION 23.
14. FOR MINIMUM MOUNTING HEIGHTS ABOVE FINISHED FLOOR REFER TO DETAIL A1/FA501.
15. COORDINATE ALL FIRE PROTECTION, ELECTRICAL, PLUMBING, MECHANICAL, AND STRUCTURAL WORK WITH CEILING HEIGHTS, FURNITURE LAYOUT, AND ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR COORDINATE FINAL LOCATIONS
WITH ARCHITECT, AHJ, AND FIRE PROTECTION ENGINEER.
16. ALL TERMINATIONS SHALL BE AT A TERMINAL STRIP. ALL DEVICES SHALL HAVE SCREW TERMINALS. IDENTIFY ALL CONDUCTORS INDIVIDUALLY WITH PERMANENT MARKINGS. THE USE OF WIRE NUTS SHALL NOT BE ALLOWED.
17. CONDUCTORS (WIRE) FOR ALL FIRE DETECTION AND ALARM CIRCUITS WILL BE INSTALLED WITHIN ¾-INCH MINIMUM DIAMETER METAL CONDUIT. ALL SIGNALING LINE AND INITIATING DEVICE CIRCUITS SHALL BE MINIMUM 16 GAUGE WIRE.
18. FIRE ALARM SYSTEM COMPONENTS ARE TO BE IDENTIFIED IN ACCORDANCE WITH UFC 3-600-01, 9-18.9.7. ALL CONDUIT, JUNCTION/BACK BOXES, COVERS AND COUPLINGS , WHEN PROVIDED, MUST BE FACTORY PAINTED RED IN UNFURNISHED AREAS (E.G., ABOVE CEILINGS, MECHANICAL ROOMS, ETC.). ALL CONDUIT, JUNCTION/BACK BOXES, COVERS AND COUPLINGS, WHEN PROVIDED, ARE PERMITTED TO BE PAINTED TO MATCH THE ROOM FINISHING IN FINISHED AREAS. THE INSIDE COVER OF THE JUNCTION BOX MUST BE IDENTIFIED AS "FIRE ALARM" AND THE CONDUIT MUST HAVE PAINTED RED BANDS 3/4 -IN. (20 MM) WIDE AT 20 FT (6 M) INTERVALS AND ON BOTH SIDES OF ALL FLOOR, WALL, AND CEILING PENETRATIONS. PROVIDE TYPE THW OR XHHW FOR WIRING IN WET LOCATIONS. TYPE THWN/THHN INSULATED WIRE IS NOT ACCEPTABLE FOR
UNDERGROUND WIRING OF FIRE ALARM CIRCUITS .
19. DRAWINGS INDICATE THE DESIGN INTENT. IT IS THE CONTRACTOR'S RESPONSIBILITY UNDER THE SCOPE OF WORK TO COMPLY WITH ALL CODES / STANDARDS SPECIFIED ABOVE TO ACCOMMODATE SPACE CONFIGURATION FOR NEW CONSTRUCTION INCLUSIVE OF NOTIFICATION COVERAGE, REMOTE MONITORING, CONTROLS, ACCESSORIES, AND ALL ACCEPTANCE TESTS / APPROVALS FOR A COMPLETE, FULLY COMPLIANT, AND FUNCTIONAL SYSTEM. SUBMIT SHOP
DRAWINGS IN COMPLIANCE WITH NFPA 72 TO THE AHJ FOR APPROVAL.
20. THESE DRAWINGS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN LAYOUT TO BE UTILIZED AS GUIDANCE FOR THE PLANNING OF THE FIRE ALARM SYSTEM BY THE CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL BY THE ENGINEER AND AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE IN THE SHOP DRAWINGS AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY, INCLUDING INITIATING DEVICES AND NOTIFICATION APPLIANCES, TO PROVIDE A COMPLETE INSTALLATION AND COMPLY WITH BASE STANDARDS.
21. PROVIDE ADDRESSABLE CONTROL MODULES AT LIGHTING CONTROL PANEL TO ENERGIZE EGRESS LIGHTING CONTROLLED
BY OCCUPANCY SENSORS UPON FIRE ALARM SIGNAL.
22. A CONTROLLED ZONE IS IDENTIFIED FOR USE IN THIS FACILITY AS SHOWN ON DRAWING G-111. THE FIRE ALARM CONTROL PANEL WITHIN THE CONTROLLED ZONE SHALL ONLY BE USED TO SERVE EQUIPMENT IN THAT RESPECTIVE ZONE. UNLESS OTHERWISE NOTED, CONDUITS AND CABLES CROSSING THROUGH CONTROLLED ZONES SHALL CROSS UNDER THE SLAB (FIRST FLOOR) OR GO COMPLETELY AROUND. DO NOT CROSS CONTROLLED ZONES UNLESS SPECIFICALLY IDENTIFIED.
ARCHITECTURAL DRAWINGS IDENTIFY THE STC RATINGS FOR ALL WALLS. CONDUIT AND DEVICE BOX PENETRATIONS IN SOUND RATED WALLS SHALL BE MINIMIZED, AND WHERE REQUIRED, SHALL BE TREATED TO MAINTAIN THE RATING OF THE ASSEMBLY. THOSE DEVICE BOXES MOUNTED ON THE OPPOSITE SIDES OF A RATED WALL SHALL BE STAGGERED AND NOT MOUNTED BACK TO BACK IN ORDER TO MAINTAIN THE PARTITION STC RATING. CONDUITS ENTERING A CONTROLLED ZONE THROUGH A WALL SHALL BE GROUPED TOGETHER AND LOCATED WHERE EASILY ACCESSIBLE ON THE SECURE SIDE OF THE
WALL.
XX
XX
WP
XX
WP
WP
P
GRAPHIC ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
TEMPERATURE SENSOR
CEILING-MOUNTED STROBE (XX DENOTES CANDELA RATING)
(Y DENOTES LENS COLOR; R=RED BLANK=CLEAR)
XX
REMOTE MASS NOTIFICATION LED TEXT DISPLAY
VERY EARLY WARNING SMOKE DETECTION SYSTEM (VEWSD)
EMERGENCY SHOWER/EYEWASH STATION FLOW SWITCH
CONTROL MODULE
MONITOR MODULE
WALL-MOUNTED HORN/STROBE (XX DENOTES CANDELA RATING)
XX
CEILING-MOUNTED SPEAKER
RADIO TRANSMITTER ANTENNA
WALL-MOUNTED SPEAKER/STROBE (XX DENOTES CANDELA RATING)
(XP DENOTES EXPLOSION PROOF DEVICE)
XX
XP
DIGITAL CELLULAR COMMUNICATOR PANEL
WIDE AREA MASS NOTIFICATION REMOTE INTERFACE CONTROLLER
FACP
DCCP
WAMN
FSA
GAN
NAC
LOC
LED
VD
EW
MM
CM
F
K
NOT ALL SYMBOLS USED
SD
RAT
M
M
T
Y
Y
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
S A
C R
A M
E N
T O
D
IS
T R
IC
T
J
S T
R E
E T
S A
C R
A M
E N
T O
C
A
J A
C O
B S
D
U L L E
S C
O R
N E
R P
A R
K S
U
IT
E
H E
R N
D O
N V
A
U T
A H
T E
S T
A N
D T
R A
IN
IN
G R
A N
G E
U
T T
R
C O
N S
O L
ID
A
T E
D M
IS
S
IO
N
C O
N T
R O
L C
E N
T E
R
C M
C C
H
IL
L
A
IR
F O
R C
E B
A S
E
U T
A H
S
E P
T E
M B
E R
P
W P
P -1
-D
-0
FA001
G E
N E
R A
L N
O T
E S
L
E G
E N
D S
A
N D
A B
B R
E V
IA
T
IO
N
S
J F
O U
L K
R S
A L L
W A
S S
E R
M R
A H
M A
N
W C
L A
Y
F
IR
S T
T
IT
L E
S E
C O
N D
T
IT
L E
F
IR
E A
L A
R M
JASON FOULK
FIRE PROTECTION ENGINEER
LICENSE NO.: ########
X
X
X
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
I I
I I I
I I I
I I I
I I I
III
IIIIIIIIIIIIIIIIIIIIIIII
III
III
I I I
I I I
I I I
I I I
I I I
I I I
I I I
I I I
III
III
I I I
I I I
I I I
III
III
I I I
III
III
III
III
III
III
X
X
X
X
X
X
X
X
X
X
X
X
X
W W W W W W W W W W W W W W W W W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
CO
IIIIIIIIIIII
III
I I I
I I I
I I I ss ss ss
12"
8"
8"
+4748.4
+4748.5
WWWWW
FH
FH
FH
FH
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A
R M
Y
C
O R
P
O
F
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
C T
N
S O
L I C
I T
A T
I O
N
N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R I P
T I O
N
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
S A
C R
A M
E N
D
I S
T R
I C
T
J
S
T R
E E
T
S
A C
R A
M E
N T
O
C
A
J A
C O
B S
D
U L L E
S
C
O R
N E
R
P
A R
K
S
U I T
E
H E
R N
D O
N
V
A
U T
S
T
A
A
I N
I N
G
R
A N
G
T T
R
C O
N S
O L
I D
A T
M
S
S I O
N
C
O N
T R
L
N
T E
R
C
M C
C
H I L
L
A
R
B
S
E
U
T A
H
S
E P
T E
M B
P
W P
P D
HOWARD LUSK
PROFESSIONAL ENGINEER
LICENSE NO.: 034029
H
L U
S K
H L
J F
M
R
A H
M A
N
J
C
O R
U M
N
KEYED NOTES
GENERAL SHEET NOTES
A. SEE SHEET C-001 FOR PROPOSED NOTES AND LEGEND, V-001 FOR
EXISTING.
B. SEE CU-101 TO CU-104 FOR NEW UTILITIES, REPLACEMENT FIRE
HYDRANTS, FIRE DEPARTMENT CONNECTION
C. THIS SHEET DEMONSTRATES COMPLIANCE WITH THE APPLICABLE
REQUIREMENTS OF UFC 3-600-01 PARAGRAPH 1-7.2.4.2 CODE
COMPLIANCE SITE PLAN.
D. FLOW TEST HYDRANT LOCATIONS:
STATIC PRESSURE TEST HYDRANT IS SHOWN BY CALLOUT ON THIS SHEET.
FLOW TEST FLOW HYDRANT IS LOCATED 298 FEET TO THE SOUTH EAST
ALONG THE UNAMED STREET. BOTH HYDRANTS ARE CONNECTED TO THE
SAME 12" WATER MAIN.
1. FIRE HYDRANT
2. FIRE DEPARTMENT CONNECTION
3. MAIN ENTRANCE TO BUILDING
4. DIESEL POWERED GENERATOR
5. PAD MOUNTED TRANSFORMER
6. NATURAL GAS METER AND SHUTOFF
7. DROP ARM BARRIER
8. INDICATING CONTROL VALVE WITHIN FIRE-RATED ROOM.
9. EXTERIOR ACCESS DOOR LEADING TO FIRE SPRINKLER SYSTEM
INDICATING CONTROL VALVE.
0 40 80 120
1"=40'
FS100
F I R
E
C
O D
E
C
O M
P L
I A
N C
E
S I T
E
P
L A
N
CMCC
U
N
N
A
M
E
D
S
T
R
E
E
T
U
N
N
A
M
E
D
S
T
R
E
E
T
6TH STREET
B
A
L
M
V
E
N
U
E
D
U
L
V
E
N
U
E
R
E
E
T
R
E
E
T
33' AT
STANDOFF
12"W
8"W
8"W
6"W
12"W
12"W
SEE NOTE D
M
Y
C
O R
P
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
D A
T E
M A
R K
D E
S C
R I P
T I O
N
S A
C R
A M
E N
S
T R
I C
T
J
S
T R
E E
T
S
A C
R A
M E
N T
O
C
A
J A
C O
B S
D
U L L E
S
C
O R
N E
R
P
A R
K
S
U I T
E
H E
R N
D O
N
V
A
S
E P
T E
M B
P
W P
P D
H
L U
S K
H L
J F
M
R
A H
M A
N
J
C
O R
M
WP
WP
W P
W P
W P
W P
W P
W P
A
C
D
K
2 3 4
5.3
6 8 9 10
J
B
H
G
F
3.9 5
E
G.8
G.6
6.7 7.47.2
FA102
A1
FA103
A1
FA104
A1
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A B
C
KEYPLAN
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
S A
C R
A M
E N
T O
D
IS
T R
IC
T
J
S T
R E
E T
S A
C R
A M
E N
T O
C
A
J A
C O
B S
D
U L L E
S C
O R
N E
R P
A R
K S
U
IT
E
R N
D O
N V
A
U T
A H
T E
S T
A N
D T
R A
IN
IN
G R
A N
G E
U
T T
R
C O
N S
O L
ID
A
T E
D M
IS
S
IO
N
C O
N T
R O
L C
E N
T E
R
C M
C C
H
IL
L
A
IR
F O
R C
E B
A S
E
U T
A H
S
E P
T E
M B
E R
P
W P
P -1
-D
-0
FA101
F L
O O
R P
L A
N
O V
E R
A L
L
J F
O U
L K
R S
A L L
W A
S S
E R
M R
A H
M A
N
W C
L A
Y
F
IR
S T
T
IT
L E
S E
C O
N D
T
IT
L E
F
IR
E A
L A
R M
JASON FOULK
FIRE PROTECTION ENGINEER
LICENSE NO.: ########
0 8' 16' 32'
SCALE: 1/16" = 1'-0"
PLAN NORTH
1/16" = 1'-0"A1
FLOOR PLAN - FIRE ALARM OVERALL
GENERAL NOTES
1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT
ACTUAL BUILDING CIRCUITING. REFER TO CONTRACTOR'S
DESIGN DRAWINGS FOR ACTUAL DEVICE LOCATION.
3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED
LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED
POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.
4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.
FINAL QUANTITY AND LAYOUT SHALL BE IN
ACCORDANCE WITH APPLICABLE CODES,
MANUFACTURER'S RECOMMENDATIONS, AND
EQUIPMENT LISTINGS.
5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND
HVAC SYSTEMS.
6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT
SPECIFICATIONS AND NFPA 72.
7. USE CLEAR LENS STROBES MARKED "ALERT" FOR FIRE
ALARM AND MASS NOTIFICATION SYSTEM.
8. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY
TO TEMPORARILY DEACTIVATE THE FIRE ALARM AUDIO
AND VISUAL NOTIFICATION APPLIANCES WHILE
DELIVERING VOICE MESSAGES.
9. MOUNT ALL INTERIOR FA/MNS DEVICES AT 80" TO 96" AFF
AND COORDINATE MOUNTING LOCATION WITH
ARCHITECTURAL DRAWINGS.
10. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND
COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL
DRAWINGS.
11. FIRE ALARM SYSTEM SHALL BE GROUNDED IN
ACCORDANCE WITH ALL APPLICABLE CODES AND
STANDARDS.
KEYED NOTES #
WP
W P
W P
W P
W P
W P
W P
A
C
D
K
1 2 3 4
5.3
6 8 9 10
J
B
H
G
F
3.9 5
E
G.8
G.6
6.7 7.47.2
FA102A
A1
FA104A
A1
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A B
C
KEYPLAN
B
ID
O P
T
IO
N
B
ID
O P
T
IO
N
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
S A
C R
A M
E N
T O
D
IS
T R
IC
T
J
S T
R E
E T
S A
C R
A M
E N
T O
C
A
J A
C O
B S
D
U L L E
S C
O R
N E
R P
A R
K S
U
IT
E
R N
D O
N V
A
U T
A H
T E
S T
A N
D T
R A
IN
IN
G R
A N
G E
U
T T
R
C O
N S
O L
ID
A
T E
D M
IS
S
IO
N
C O
N T
R O
L C
E N
T E
R
C M
C C
H
IL
L
A
IR
F O
R C
E B
A S
E
U T
A H
S
E P
T E
M B
E R
P
W P
P -1
-D
-0
FA101A
F L
O O
R P
L A
N
O V
E R
A L
L B
ID
O
P T
IO
N
J F
O U
L K
R S
A L L
W A
S S
E R
M R
A H
M A
N
W C
L A
Y
F
IR
S T
T
IT
L E
S E
C O
N D
T
IT
L E
F
IR
E A
L A
R M
JASON FOULK
FIRE PROTECTION ENGINEER
LICENSE NO.: ########
1/16" = 1'-0"A1
FLOOR PLAN - FIRE ALARM OVERALL BID OPTION 2 & 3
0 8' 16' 32'
SCALE: 1/16" = 1'-0"
PLAN NORTH
GENERAL NOTES
1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT
ACTUAL BUILDING CIRCUITING. REFER TO CONTRACTOR'S
DESIGN DRAWINGS FOR ACTUAL DEVICE LOCATION.
3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED
LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED
POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.
4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.
FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE
WITH APPLICABLE CODES, MANUFACTURER'S
RECOMMENDATIONS, AND EQUIPMENT LISTINGS.
5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND
HVAC SYSTEMS.
6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT
SPECIFICATIONS AND NFPA 72.
7. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO
TEMPORARILY DEACTIVATE THE FIRE ALARM AUDIO AND
VISUAL NOTIFICATION APPLIANCES WHILE DELIVERING
VOICE MESSAGES.
8. MOUNT ALL INTERIOR FA/MNS WALL MOUNTED DEVICES
AT 80" TO 96" AFF AND COORDINATE MOUNTING LOCATION
WITH ARCHITECTURAL DRAWINGS.
9. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND
COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL
DRAWINGS.
10. FIRE ALARM SYSTEM SHALL BE GROUNDED IN
ACCORDANCE WITH ALL APPLICABLE CODES AND
KEYED NOTES #
M N
F
L O
C
L O
C F
S A
P
WP
F
F F F
R A
T
CO
CO
30 15
110 110
75 75
75 75
N A
C
LED
LED
LED
N A
C
V D
P
P
VD
W P
W P
W P
W P
M M
MM
MM
MM
MM
MM
CM
CM
CM
MM
MM
CM
MM
CM
CM
F A
M N
CM
CM
C
D
K
2 3 4
5.3
J
H
G
F
3.9 5
E
LOBBY
BREAK ROOM
WOMEN
JAN
MEN
MECHANICAL
ROOM
CLASSROOM /
CONF
SOFT. DEV.
EQUIPMENT
BOILER ROOM
WOMEN
JAN
MEN
ELECTRICAL
UTTR COMM
CORRIDOR
C102
VESTIBULE
UPS ROOM
CORRIDOR
C101
SOFT. DEV.
GOV OFFICE 4
GOV OPEN
OFFICE
JT4 OPEN
OFFICE
VESTIBULE
PACKING
GOV OFFICE 1
GOV OFFICE 2
GOV OFFICE 3
ELECTRICAL
JT4 OFFICE
122A
STAN-EVAL
TESTING
WELLNESS
4(TYP. OF 4)
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
KEYPLAN
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
S A
C R
A M
E N
T O
D
IS
T R
IC
T
J
S T
R E
E T
S A
C R
A M
E N
T O
C
A
J A
C O
B S
D
U L L E
S C
O R
N E
R P
A R
K S
U
IT
E
R N
D O
N V
A
U T
A H
T E
S T
A N
D T
R A
IN
IN
G R
A N
G E
U
T T
R
C O
N S
O L
ID
A
T E
D M
IS
S
IO
N
C O
N T
R O
L C
E N
T E
R
C M
C C
H
IL
L
A
IR
F O
R C
E B
A S
E
U T
A H
S
E P
T E
M B
E R
P
W P
P -1
-D
-0
FA102
F L
O O
R P
L A
N
A R
E A
A
J F
O U
L K
R S
A L L
W A
S S
E R
M R
A H
M A
N
W C
L A
Y
F
IR
S T
T
IT
L E
S E
C O
N D
T
IT
L E
F
IR
E A
L A
R M
JASON FOULK
FIRE PROTECTION ENGINEER
LICENSE NO.: ########
8'4' 16'0
SCALE: 1/8"=1'-0"
PLAN NORTH
GENERAL NOTES
1 PROVIDE VERY EARLY WARNING SMOKE DETECTION (VEWSD) FOR IT AREA
IN ACCORDANCE WITH NFPA 75.
2 FIRE ALARM RADIO ANTENNA
3 MONACO BT2-8NB (16/32 ZONE)
4 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH CONTROL VALVE
TAMPER SWITCH TO FIRE ALARM SYSTEM FOR SUPERVISORY FUNCTION.
VERIFY LOCATION WITH SPRINKLER CONTRACTOR.
5 PROVIDE CARBON MONOXIDE DETECTION IN ACCORDANCE WITH UFC
3-600-01, NFPA 720 AND MANUFACTURER'S REQUIREMENTS.
6 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR INTERFACE
WITH SUPPLY SIDE DUCT SMOKE DETECTOR. INSTALL EQUIPMENT AT
MANUFACTURER'S PROVIDED CONTACTS (REFER TO MECHANICAL
DRAWINGS FOR LOCATION). MOUNT DEVICE IN ACCORDANCE WITH
MANUFACTURER'S REQUIREMENTS, NFPA 72, AND NFPA 90A. CONNECTIONS
TO FIRE ALARM SYSTEM SHALL BE PROVIDED BY DIVISION 28.
CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY DIVISION 23.
7 PROVIDE SEPARATE MONITOR MODULES AS NECESSARY FOR MONITORING
OF EACH ALARM, TROUBLE, AND SUPERVISORY FUNCTION OF THE VEWSD
SYSTEM.
8 ADDRESSABLE CONTROL MODULE FOR SHUTDOWN OF CRAC UNIT UPON
VEWSD LEVEL 3 ALARM.
9 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH FLOW SWITCH TO
FIRE ALARM PANEL FOR ALARM FUNCTION.
10 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR INTERFACE
WITH SMOKE DAMPER DUCT SMOKE DETECTOR. MOUNT DEVICE IN
ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS, NFPA 72, AND
NFPA 90A. CONNECTIONS TO FIRE ALARM SYSTEM SHALL BE PROVIDED BY
DIVISION 28. CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY
DIVISION 23.
11 VEWSD MONITORING STATION.
KEYED NOTES #
1/8" = 1'-0"A1
FLOOR PLAN - FIRE ALARM AREA A
1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT ACTUAL BUILDING
CIRCUITING. REFER TO CONTRACTOR'S DESIGN DRAWINGS FOR ACTUAL
DEVICE LOCATION.
3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED LETTER "FIRE ALARM
CIRCUIT" ON THE DEDICATED POWER CIRCUIT BREAKER AND/OR
DISCONNECT SWITCH.
4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS. FINAL QUANTITY AND
LAYOUT SHALL BE IN ACCORDANCE WITH APPLICABLE CODES,
MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS.
5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND HVAC SYSTEMS.
6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT SPECIFICATIONS AND NFPA
72.
7. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO TEMPORARILY
DEACTIVATE THE FIRE ALARM AUDIO AND VISUAL NOTIFICATION APPLIANCES
WHILE DELIVERING VOICE MESSAGES.
8. REFER TO A1/FA501 FOR MOUNTING HEIGHTS OF ALL INTERIOR FA/MNS WALL
MOUNTED DEVICES AND COORDINATE MOUNTING LOCATION WITH
ARCHITECTURAL DRAWINGS.
9. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND COORDINATE
MOUNTING LOCATION WITH ARCHITECTURAL DRAWINGS.
10. FIRE ALARM SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH ALL
APPLICABLE CODES AND STANDARDS.
M N
F
L O
C
L O
C F
S A
P
WP
F
F F F
R A
T
CO
CO
30 15
110 110
75 75
75 75
N A
C
LED
LED
LED
N A
C
V D
P
P
VD
FLED
W P
W P
W P
W P
M M
MM
MM
MM
MM
MM
CM
CM
CM
MM
MM
CM
MM
CM
CM
F A
M N
CM
CM
C
D
K
1 2 3 4
5.3
J
H
G
F
3.9 5
E
LOBBY
BREAK ROOM
WOMEN
JAN
MEN
MECHANICAL
ROOM
CLASSROOM /
CONF
SOFT. DEV.
EQUIPMENT
124 BOILER ROOM
WOMEN
JAN
MEN
ELECTRICAL
UTTR COMM
VESTIBULE
UPS ROOM
CORRIDOR
C101
GOV OFFICE 6
GOV OFFICE 7
GOV OFFICE 4
JT4 OPEN
OFFICE
GOV OPEN
OFFICE
SOFT. DEV.
GOV OFFICE 3
GOV OFFICE 2
GOV OFFICE 1
PACKING
ELECTRICAL
JT4 OFFICE
122A
STAN-EVAL
TESTING
WELLNESS
157GOV OFFICE 5
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
KEYPLAN
B
ID
O P
T
IO
N
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
S A
C R
A M
E N
T O
D
IS
T R
IC
T
J
S T
R E
E T
S A
C R
A M
E N
T O
C
A
J A
C O
B S
D
U L L E
S C
O R
N E
R P
A R
K S
U
IT
E
R N
D O
N V
A
U T
A H
T E
S T
A N
D T
R A
IN
IN
G R
A N
G E
U
T T
R
C O
N S
O L
ID
A
T E
D M
IS
S
IO
N
C O
N T
R O
L C
E N
T E
R
C M
C C
H
IL
L
A
IR
F O
R C
E B
A S
E
U T
A H
S
E P
T E
M B
E R
P
W P
P -1
-D
-0
FA102A
F L
O O
R P
L A
N
A R
E A
A
B
ID
O P
T
IO
N
J F
O U
L K
R S
A L L
W A
S S
E R
M R
A H
M A
N
W C
L A
Y
F
IR
S T
T
IT
L E
S E
C O
N D
T
IT
L E
F
IR
E A
L A
R M
JASON FOULK
FIRE PROTECTION ENGINEER
LICENSE NO.: ########
8'4' 16'0
SCALE: 1/8"=1'-0"
PLAN NORTH
GENERAL NOTES
1 PROVIDE VERY EARLY WARNING SMOKE DETECTION (VEWSD) FOR IT
AREA IN ACCORDANCE WITH NFPA 75.
2 MONACO BT2-8NB (16/32 ZONE)
3 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH CONTROL
VALVE TAMPER SWITCH TO FIRE ALARM SYSTEM FOR SUPERVISORY
FUNCTION. VERIFY LOCATION WITH SPRINKLER CONTRACTOR.
4 PROVIDE CARBON MONOXIDE DETECTION IN ACCORDANCE WITH UFC
3-600-01, NFPA 720 AND MANUFACTURER'S REQUIREMENTS.
5 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR INTERFACE
WITH SUPPLY SIDE DUCT SMOKE DETECTOR. INSTALL EQUIPMENT AT
MANUFACTURER'S PROVIDED CONTACTS (REFER TO MECHANICAL
DRAWINGS FOR LOCATION). MOUNT DEVICE IN ACCORDANCE WITH
MANUFACTURER'S REQUIREMENTS, NFPA 72, AND NFPA 90A.
CONNECTIONS TO FIRE ALARM SYSTEM SHALL BE PROVIDED BY DIVISION
28. CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY
DIVISION 23.
6 PROVIDE SEPARATE MONITOR MODULES AS NECESSARY FOR
MONITORING OF EACH ALARM, TROUBLE, AND SUPERVISORY FUNCTION
OF THE VEWSD SYSTEM.
7 ADDRESSABLE CONTROL MODULE FOR SHUTDOWN OF CRAC UNIT UPON
VEWSD LEVEL 3 ALARM.
8 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH FLOW SWITCH
TO FIRE ALARM PANEL FOR ALARM FUNCTION.
9 FIRE ALARM RADIO ANTENNA
10 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR INTERFACE
WITH SMOKE DAMPER DUCT SMOKE DETECTOR. MOUNT DEVICE IN
ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS, NFPA 72, AND
NFPA 90A. CONNECTIONS TO FIRE ALARM SYSTEM SHALL BE PROVIDED
BY DIVISION 28. CONNECTIONS TO HVAC EQUIPMENT SHALL BE
PROVIDED BY DIVISION 23.
11 VEWSD MONITORING STATION.
KEYED NOTES #
1/8" = 1'-0"A1
FLOOR PLAN - FIRE ALARM AREA A - BID OPTION 2
1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.
2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT ACTUAL BUILDING
CIRCUITING. REFER TO CONTRACTOR'S DESIGN DRAWINGS FOR ACTUAL
DEVICE LOCATION.
3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED LETTER "FIRE ALARM
CIRCUIT" ON THE DEDICATED POWER CIRCUIT BREAKER AND/OR
DISCONNECT SWITCH.
4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS. FINAL QUANTITY
AND LAYOUT SHALL BE IN ACCORDANCE WITH APPLICABLE CODES,
MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS.
5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND HVAC SYSTEMS.
6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT SPECIFICATIONS AND
NFPA 72.
7. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO TEMPORARILY
DEACTIVATE THE FIRE ALARM AUDIO AND VISUAL NOTIFICATION
APPLIANCES WHILE DELIVERING VOICE MESSAGES.
8. REFER TO A1/FA501 FOR MOUNTING HEIGHTS OF ALL INTERIOR FA/MNS
WALL MOUNTED DEVICES AND COORDINATE MOUNTING LOCATION WITH
ARCHITECTURAL DRAWINGS.
9. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND COORDINATE
MOUNTING LOCATION WITH ARCHITECTURAL DRAWINGS.
10. FIRE ALARM SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH ALL
APPLICABLE CODES AND STANDARDS.
11. HALFTONE INDICATES DEVICES ARE INCLUDED AS PART OF BASE BID.
OTHER DEVICES ARE IN ADDITION TO OR RELOCATED FROM BASE BID AS
PART OF ABI 2.
F F
F
30 30
15 15 15
15 15
L E
D L E
D
LED
VD
VD
V D
V D
V D
V D
W P
MM
M M
M M
M M
M M
M M
CM
MM
CM
MM
CM
MM
MM
CM
MM
CM
MM
PF
A
M N
CM
CM
CM
CM
CM
CM
CMCM
CM
CM
K
6 8 9 10
J
H
G
E
G.8
G.6
6.7 7.47.2
TM1
MCR 1
MCR 1 VIP
VIDEO
SUPPORT
MCR 2
MCR 2 VIP
VIDEO ROOM
ELECTRICAL
TSPI
COMM VAULT
SCR / GUEST
BREAK ROOM
TELEMETRY
(TM1)
TELEMETRY
(TM2)
VIDEO ROOM
TSPI
CONFERENCE
(SECURE)
POST FLIGHT
CORRIDOR
C102
CORRIDOR
C104
TM2
CORRIDOR
C103
VESTIBULE
VESTIBULE
VESTIBULE
RMF
5 5
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
B
KEYPLAN
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
S A
C R
A M
E N
T O
D
IS
T R
IC
T
J
S T
R E
E T
S A
C R
A M
E N
T O
C
A
J A
C O
B S
D
U L L E
S C
O R
N E
R P
A R
K S
U
IT
E
R N
D O
N V
A
U T
A H
T E
S T
A N
D T
R A
IN
IN
G R
A N
G E
U
T T
R
C O
N S
O L
ID
A
T E
D M
IS
S
IO
N
C O
N T
R O
L C
E N
T E
R
C M
C C
H
IL
L
A
IR
F O
R C
E B
A S
E
U T
A H
S
E P
T E
M B
E R
P
W P
P -1
-D
-0
FA103
F L
O O
R P
L A
N
A R
E A
B
J F
O U
L K
R S
A L L
W A
S S
E R
M R
A H
M A
N
W C
L A
Y
F
IR
S T
T
IT
L E
S E
C O
N D
T
IT
L E
F
IR
E A
L A
R M
JASON FOULK
FIRE PROTECTION ENGINEER
LICENSE NO.: ########
8'4' 16'0
SCALE: 1/8"=1'-0"
PLAN NORTH
GENERAL NOTES
KEYED NOTES #
1 PROVIDE VERY EARLY WARNING SMOKE DETECTION (VEWSD)
FOR IT AREA IN ACCORDANCE WITH NFPA 75.
2 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH
CONTROL VALVE TAMPER SWITCH TO FIRE ALARM SYSTEM
FOR SUPERVISORY FUNCTION. VERIFY LOCATION WITH
SPRINKLER CONTRACTOR.
3 ADDRESSABLE CONTROL MODULE FOR SHUTDOWN OF CRAC
UNIT UPON VEWSD LEVEL 3 ALARM.
4 PROVIDE SEPARATE MONITOR MODULES AS NECESSARY FOR
MONITORING OF EACH ALARM, TROUBLE, AND SUPERVISORY
FUNCTION OF THE VEWSD SYSTEM.
5 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR
INTERFACE WITH SMOKE DAMPER DUCT SMOKE DETECTOR.
MOUNT DEVICE IN ACCORDANCE WITH MANUFACTURER'S
REQUIREMENTS, NFPA 72, AND NFPA 90A. CONNECTIONS TO
FIRE ALARM SYSTEM SHALL BE PROVIDED BY DIVISION 28.
CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY
DIVISION 23.
6 MOUNT VISUAL NOTIFICATION DEVICE ABOVE EQUIPMENT
PLATFORM.
1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
2. REFER TO FA101 FOR FIRE ALARM OVERALL PLAN.
3. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT
ACTUAL BUILDING CIRCUITING. REFER TO CONTRACTOR'S
DESIGN DRAWINGS FOR ACTUAL DEVICE LOCATION.
4. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED
LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED
POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.
5. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.
FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE
WITH APPLICABLE CODES, MANUFACTURER'S
RECOMMENDATIONS, AND EQUIPMENT LISTINGS.
6. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND
HVAC SYSTEMS.
7. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT
SPECIFICATIONS AND NFPA 72.
8. USE CLEAR LENS STROBES MARKED "ALERT" FOR FIRE
ALARM AND MASS NOTIFICATION SYSTEM.
9. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO
TEMPORARILY DEACTIVATE THE FIRE ALARM AUDIO AND
VISUAL NOTIFICATION APPLIANCES WHILE DELIVERING
VOICE MESSAGES.
10. REFER TO A1/FA501 FOR MOUNTING HEIGHTS OF ALL
INTERIOR FA/MNS WALL MOUNTED DEVICES AND
COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL
DRAWINGS.
11. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND
COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL
DRAWINGS.
12. FIRE ALARM SYSTEM SHALL BE GROUNDED IN
ACCORDANCE WITH ALL APPLICABLE CODES AND
STANDARDS.
1/8" = 1'-0"A1
FLOOR PLAN - FIRE ALARM AREA B
L E
D
R R
R R
W P
VD
VD
MM
M M
MM
CM
MM CM
CM
CM
CM
CM CM
FF
CM
A
C
6 8 9 107
B
AOC OPS
AOC OPS
AOC COMM
HRC
CORRIDOR
C105
LINK 16
5 6
6 6
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C
KEYPLAN
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
S A
C R
A M
E N
T O
D
IS
T R
IC
T
J
S T
R E
E T
S A
C R
A M
E N
T O
C
A
J A
C O
B S
D
U L L E
S C
O R
N E
R P
A R
K S
U
IT
E
R N
D O
N V
A
U T
A H
T E
S T
A N
D T
R A
IN
IN
G R
A N
G E
U
T T
R
C O
N S
O L
ID
A
T E
D M
IS
S
IO
N
C O
N T
R O
L C
E N
T E
R
C M
C C
H
IL
L
A
IR
F O
R C
E B
A S
E
U T
A H
S
E P
T E
M B
E R
P
W P
P -1
-D
-0
FA104
F L
O O
R P
L A
N
A R
E A
C
J F
O U
L K
R S
A L L
W A
S S
E R
M R
A H
M A
N
W C
L A
Y
F
IR
S T
T
IT
L E
S E
C O
N D
T
IT
L E
F
IR
E A
L A
R M
JASON FOULK
FIRE PROTECTION ENGINEER
LICENSE NO.: ########
8'4' 16'0
SCALE: 1/8"=1'-0"
PLAN NORTH
GENERAL NOTESGENERAL NOTES
1 INSTALL NOTIFICATION DEVICES WITHIN SPACE IN
ACCORDANCE WITH UFC 4-133-01, 4-2.6.1.
2 PROVIDE VERY EARLY WARNING SMOKE DETECTION (VEWSD)
FOR IT AREA IN ACCORDANCE WITH NFPA 75.
3 ADDRESSABLE CONTROL MODULE FOR SHUTDOWN OF CRAC
UNIT UPON VEWSD LEVEL 3 ALARM.
4 PROVIDE SEPARATE MONITOR MODULES AS NECESSARY FOR
MONITORING OF EACH ALARM, TROUBLE, AND SUPERVISORY
FUNCTION OF THE VEWSD SYSTEM.
5 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH
CONTROL VALVE TAMPER SWITCH TO FIRE ALARM SYSTEM
FOR SUPERVISORY FUNCTION. VERIFY LOCATION WITH
SPRINKLER CONTRACTOR.
6 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR
INTERFACE WITH SMOKE DAMPER DUCT SMOKE DETECTOR.
MOUNT DEVICE IN ACCORDANCE WITH MANUFACTURER'S
REQUIREMENTS, NFPA 72, AND NFPA 90A. CONNECTIONS TO
FIRE ALARM SYSTEM SHALL BE PROVIDED BY DIVISION 28.
CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY
DIVISION 23.
7 PROVIDE FIRE ALARM SYSTEM IN ACCORDANCE WITH UFC
4-133-01, 3-6.7.3.
8 PROVIDE LOCAL AUDIBLE ALARM. LOCAL ALARM TO BE
INITIATED UPON VEWSD SYSTEM LEVEL 1 AND 2 ACTIVATION.
9 ADDRESSABLE CONTROL MODULE FOR ELECTRONIC
EQUIPMENT POWER SHUTDOWN FUNCTION UPON ZERO
DELAY FLOW SWITCH ACTIVATION.
KEYED NOTES #
1/8" = 1'-0"A1
FLOOR PLAN - FIRE ALARM AREA C
1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT
ACTUAL BUILDING CIRCUITING. REFER TO CONTRACTOR'S
DESIGN DRAWINGS FOR ACTUAL DEVICE LOCATION.
3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED
LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED
POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.
4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.
FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE
WITH APPLICABLE CODES, MANUFACTURER'S
RECOMMENDATIONS, AND EQUIPMENT LISTINGS.
5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND
HVAC SYSTEMS.
6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT
SPECIFICATIONS AND NFPA 72.
7. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO
TEMPORARILY DEACTIVATE THE FIRE ALARM AUDIO AND
VISUAL NOTIFICATION APPLIANCES WHILE DELIVERING
VOICE MESSAGES.
8. REFER TO A1/FA501 FOR MOUNTING HEIGHTS OF ALL
INTERIOR FA/MNS WALL MOUNTED DEVICES AND
COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL
DRAWINGS.
9. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND
COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL
DRAWINGS.
10. FIRE ALARM SYSTEM SHALL BE GROUNDED IN
ACCORDANCE WITH ALL APPLICABLE CODES AND
L E
D
R R
R R
W P
VD
VD
MM
M
M
MM
CM
MM CM
CM
CM
CM
CM CM
FF
CM
A
C
6 8 9 107
B
AOC OPS
LINK 16
HRC
AOC COMM
AOC BENCH /
STORAGE
CORRIDOR
C105
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C
KEYPLAN
B
ID
O P
T
IO
N
UNCLASSIFIED / FOR OFFICIAL USE ONLY
UNCLASSIFIED / FOR OFFICIAL USE ONLY
CORRECTED FINAL (100%) DESIGN SUBMITTAL
S A
C R
A M
E N
T O
D
IS
T R
IC
T
J
S T
R E
E T
S A
C R
A M
E N
T O
C
A
J A
C O
B S
D
U L L E
S C
O R
N E
R P
A R
K S
U
IT
E
R N
D O
N V
A
U T
A H
T E
S T
A N
D T
R A
IN
IN
G R
A N
G E
U
T T
R
C O
N S
O L
ID
A
T E
D M
IS
S
IO
N
C O
N T
R O
L C
E N
T E
R
C M
C C
H
IL
L
A
IR
F O
R C
E B
A S
E
U T
A H
S
E P
T E
M B
E R
P
W P
P -1
-D
-0
FA104A
F L
O O
R P
L A
N
A R
E A
C
B
ID
O P
T
IO
N
J F
O U
L K
R S
A L L
W A
S S
E R
M R
A H
M A
N
W C
L A
Y
F
IR
S T
T
IT
L E
S E
C O
N D
T
IT
L E
F
IR
E A
L A
R M
JASON FOULK
FIRE PROTECTION ENGINEER
LICENSE NO.: ########
1/8" = 1'-0"A1
FLOOR PLAN - FIRE ALARM AREA C - BID OPTION 3
8'4' 16'0
SCALE: 1/8"=1'-0"
PLAN NORTH
GENERAL NOTESGENERAL NOTES
1 INSTALL NOTIFICATION DEVICES WITHIN SPACE IN
ACCORDANCE WITH UFC 4-133-01, 4-2.6.1.
2 PROVIDE VERY EARLY WARNING SMOKE DETECTION (VEWSD)
FOR IT AREA IN ACCORDANCE WITH NFPA 75.
3 ADDRESSABLE CONTROL MODULE FOR SHUTDOWN OF CRAC
UNIT UPON VEWSD LEVEL 3 ALARM.
4 PROVIDE SEPARATE MONITOR MODULES AS NECESSARY FOR
MONITORING OF EACH ALARM, TROUBLE, AND SUPERVISORY
FUNCTION OF THE VEWSD SYSTEM.
5 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH
CONTROL VALVE TAMPER SWITCH TO FIRE ALARM SYSTEM
FOR SUPERVISORY FUNCTION. VERIFY LOCATION WITH
SPRINKLER CONTRACTOR.
6 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR
INTERFACE WITH SMOKE DAMPER DUCT SMOKE DETECTOR.
MOUNT DEVICE IN ACCORDANCE WITH MANUFACTURER'S
REQUIREMENTS, NFPA 72, AND NFPA 90A. CONNECTIONS TO
FIRE ALARM SYSTEM SHALL BE PROVIDED BY DIVISION 28.
CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY
DIVISION 23.
7 PROVIDE FIRE ALARM SYSTEM IN ACCORDANCE WITH UFC
4-133-01, 3-6.7.3.
8 PROVIDE LOCAL AUDIBLE ALARM. LOCAL ALARM TO BE
INITIATED UPON VEWSD SYSTEM LEVEL 1 AND 2 ACTIVATION.
9 ADDRESSABLE CONTROL MODULE FOR ELECTRONIC
EQUIPMENT POWER SHUTDOWN FUNCTION UPON ZERO
DELAY FLOW SWITCH ACTIVATION.
KEYED NOTES #
1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND
GENERAL NOTES.
2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT
ACTUAL BUILDING CIRCUITING. REFER TO CONTRACTOR'S
DESIGN DRAWINGS FOR ACTUAL DEVICE LOCATION.
3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED
LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED
POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.
4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.
FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE
WITH APPLICABLE CODES, MANUFACTURER'S
RECOMMENDATIONS, AND EQUIPMENT LISTINGS.
5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND
HVAC SYSTEMS.
6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT
SPECIFICATIONS AND NFPA 72.
7. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO
TEMPORARILY DEACTIVATE THE FIRE ALARM AUDIO AND
VISUAL NOTIFICATION APPLIANCES WHILE DELIVERING
VOICE MESSAGES.
8. REFER TO A1/FA501 FOR MOUNTING HEIGHTS OF ALL
INTERIOR FA/MNS WALL MOUNTED DEVICES AND
COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL
DRAWINGS.
9. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND
COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL
DRAWINGS.
10. FIRE ALARM SYSTEM SHALL BE GROUNDED IN
ACCORDANCE WITH ALL APPLICABLE CODES AND
STANDARDS.
11. HALFTONE INDICATES DEVICES ARE INCLUDED AS PART
OF BASE BID. OTHER DEVICES ARE IN ADDITION TO OR
RELOCATED FROM BASE BID AS PART OF ABI 3.
LOCAL
OPERATING
CONSOLE
1 0
1 1
1 2
1 4
1 5
1 6
1 7
1 8
1 9
2 0
2 1
2 2
2 3
2 4
OK TO
PAGE
MIC
TBL
ALL
CALL
1 1 3
SYSTEM
CONT ROL
SYSTEM
IN
USE
FIRE SYSTEM
ACTIVE
MANUAL PULL STATION ACTIVATION
FIRE ALARM SYSTEM TROUBLE
FIRE ALARM SYSTEM PRIMARY POWER LOSS
OPERATION OF MASS NOTIFICATION SYSTEM
ACTIVATION OF GENERAL CARBON MONOXIDE DETECTOR
VEWSD LEVEL 1 ACTIVATION
VEWSD LEVEL 2 ACTIVATION
VEWSD LEVEL 3 ACTIVATION
NOTIFICATION
SYSTEM OUTPUTSACTIONS
SYSTEM INPUTS A
F A
M N
P A
LA
R
M L
E D
A N
D A
U D
IB
LE
S
IG
N A
L
F A
M N
P S
U P
E R
V
IS
O R
Y L
E D
A N
D A
U D
IB
LE
S
IG
N A
L
F A
M N
P T
R O
U B
LE
L
E D
A N
D A
U D
IB
LE
S
IG
N A
L
A C
T
IV
A T
E M
A S
S N
O T
IF
IC
A T
IO
N
S Y
S T
E M
M E
S S
A G
E
IL
LU
M
IN
A T
E A
S S
O C
IA
T
E D
R E
M O
T E
L E
D
REQUIRED FIRE
SAFETY CONTROL
F A
M N
P M
A S
S N
O T
IF
IC
A T
IO
N
A
LA
R M
L E
D A
N D
A U
D
IB
LE
S
IG
N
A L
S H
U T
D O
W N
A S
S O
C
IA
T E
D H
V A
C U
N
IT
O N
LY
CONTROL UNIT
ANNUNCIATION
F A
M N
P L
C D
M E
S S
A G
E
D E
A C
T
IV
A T
E F
IR
E
A
LA
R M
A U
D
IB
LE
S
IG
N
A L
A N
D P
A F
U N
C T
IO
N
T R
A N
S M
IT
T
R O
U B
LE
S
IG
N
A L
T O
C E
N T
R A
L S
T A
T
IO
N /F
IR
E
D E
P T
T R
A N
S M
IT
S
U P
E R
V
IS
O R
Y S
IG
N
A L
T O
C E
N T
R A
L S
T A
T
IO
N /F
IR
E
D E
P T
T R
A N
S M
IT
F
IR
E
A
LA
R M
S
IG
N A
L T
O C
E N
T R
A L
S T
A T
IO
N
/F
IR
E D
E P
T
A C
T
IV
A T
E F
IR
E
A
LA
R M
E V
A C
U A
T
IO
N A
U D
IB
LE
/V
IS
U A
L A
LA
R
M S
A C
T
IV
A T
E N
O T
IF
IC
A T
IO
N
/T R
A N
S M
IT
C
O S
IG
N
A L
T O
C E
N T
R A
L S
T A
T
IO
N
A C
T
IV
A T
E E
X T
E R
IO
R
E
LE
C T
R
IC
B E
LL
S E
N D
S
IG
N A
L T
O S
H U
T D
O W
N P
O W
E R
T O
C E
R /S
E R
V E
R R
O O
M
INDICATES ACTION WILL CAUSE SPECIFIC RESULTS INDICATES ACTION WILL NOT CAUSE SPECIFIC RESULTS
FIRE ALARM AND MASS NOTIFICATION MATRIX
S E
N D
S
IG
N A
L T
O E
N E
R G
IZ
E
E G
R E
S S
L
IG
H T
IN
G
C O
N T
R O
LL
E
D B
Y O
C C
U P
A N
T S
E N
S O
R S
1 1
B C D E F G H I J K L N O P
AREA SMOKE DETECTOR ACTIVATION2
SPRINKLER WATERFLOW SWITCH ACTIVATION3
SPRINKLER CONTROL VALVE
TAMPER SWITCH ACTIVATION
DUCT SMOKE DETECTOR ACTIVATION5
SYSTEM INPUTS A B C D E F G H I J K L M N O P Q R S T U V W X
Y
D O
O R
H O
LD
R
E
LE
A S
E
Z
OPERATION OF WIDE AREA MASS NOTIFICATION SYSTEM
S M
O K
E D
A M
P E
R A
C T
U A
T
IO
N
Q R S T
FIRE ALARM AC POWER FAILURE
A C
T
IV
A T
E U
N
IQ
U E
C O
D E
T E
C T
IO
N
V O
IC
E
N O
T
IF
IC
A
T
IO
N M
E S
S A
G E
M U
A C
T
IV
A T
E L
O C
A L
A U
D
IB
LE
A
LA
R
M
VEWSD LEVEL 1 ACTIVATION (AOC COMM…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .