Atch 4_Design_DrawingsVol2_091319.pdf

PDF 45 MB Posted

Attached to
UTTR CMCC at Hill AFB, UT Federal contract opportunity
Solicitation number
W91238-19-R-0026
Issued by
Department of the Army Corps of Engineers Engineering District Sacramento

About this file

This document provides details on a federal contract opportunity for construction services. The U.S. Army Corps of Engineers Engineering District Sacramento is soliciting proposals for a firm-fixed price construction contract to build a Consolidated Mission Control Center at Hill Air Force Base in Utah. The project scope involves constructing a new facility to replace outdated air traffic control and mission evaluation facilities at the Utah Test and Training Range. The building is intended to consolidate important functional relationships and adhere to industry standards, applicable codes, and the Hill Air Force Base Design Guide. The estimated value of construction is between $25-100 million. Responses are due under Solicitation Number W91238-19-R-0026. The period of performance is 852 days. A site visit will be scheduled upon release of the solicitation. The small business set-aside aims to award a contract by early 2020.

View the file

Other files for this federal contract opportunity

Other files attached to UTTR CMCC at Hill AFB, UT, newest first.
File Type Posted
CMCC Site Visit Sign In 10-7-2020.pdf PDF
Atch 2_SpecsVol2_101119.pdf PDF
Atch 6_CMCC Site Walk 07OCT2020.pdf PDF
Atch 3_Design_DrawingsVol1_091319.pdf PDF
Atch 7_Utah Resident Office Map.pdf PDF
Atch 1_SpecsVol1_101119.pdf PDF
Atch 5_WDs DB Weber County 8-28-2020.pdf PDF
SF1442 Final W9123819R0026 UTTR CMCC 24SEP2020.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CIVIL / LANDSCAPE

HOWARD LUSK

STRUCTURAL

BRIAN HORSTMANN

ARCHITECTURAL

BRYAN DYSON

INTERIORS

BRIANA ERNSTING

FIRE ALARM /

FIRE SUPPRESSION

JASON FOULK

PLUMBING / MECHANICAL

JAMES MOLER

ELECTRICAL

OSAMA FARES

TELECOMMUNICATIONS

SCOTT HANSBERRY

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

US Army Corps of Engineers ®

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

VOLUME:

M

AR

K D

ES

C

R

IP

TI

O

N

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

JA

C

O

BS

D U

LL

ES

C O

R N

ER

P

AR

K, S U

IT

E

H

ER

N D

O N

, V A

U

TA

H T

ES

T

AN

D

T R

AI

N

IN

G

R

AN

G E

(U

TT

R

C O

N

SO

LI

D

AT

ED

M

IS

SI

O

N C

O N

TR

O

L C

EN

TE

R (C

M C

C)

HI

LL

A

IR

F

O

RC

E

BA

SE

, U

TA

H

S

EP

TE

M

BE

R

P2 #3

W

2P P-

-D

-0

PACKAGE 1

TIRAGGA NO.:

LEGACY NO.:

WORK ORDER NO.:

1022042

KRSM123009

54827

G-000

CO

V E

R

SH

EE

T

E.

B

R O

N

ST

EI

N

N . F

R

EY

M . R

AH

M

AN

K.

H

AR

G

R

EA

VE

S

FI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

SACRAMENTO DISTRICT

P2#333029

W912PP-17-D-0010

13 SEPTEMBER 2019

HILL AIR FORCE BASE, UTAH

UTAH TEST AND TRAINING RANGE (UTTR)

CONSOLIDATED MISSION CONTROL CENTER (CMCC)

CORRECTED FINAL (100%) DESIGN SUBMITTAL

G E N

ER

A L

DRAWING INDEX - VOLUME 1 OF 2

SHEET

NUMBER SHEET NAME

SHEET

NUMBER SHEET NAME

SHEET

NUMBER SHEET NAME

SHEET

NUMBER SHEET NAME

SHEET

NUMBER SHEET NAME

SHEET

NUMBER SHEET NAME

DRAWING INDEX - VOLUME 2 OF 2

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

JA

C

O

BS

D U

LL

ES

C O

R N

ER

P

AR

K, S U

IT

E

H

ER

N D

O N

, V A

U

TA

H

TE

ST

A

N D

T

RA

IN

IN

G R

AN

G

E (U

TT

R)

CO

NS

O

LI

DA

TE

D

M

IS

SI

O

N

CO

NT

RO

L

CE

NT

ER

(C M

CC

HI

LL

A

IR

F O

RC

E

BA

SE

, U

TA

H

S

EP

TE

M

BE

R

P2 #3

W

2P P-

-D

-0

G-001

DR

AW

IN

G

I N

DE

X

E.

B

R O

N

ST

EI

N

N . F

R

EY

M . R

AH

M

AN

K.

H

AR

G

R

EA

VE

S

FI

R

ST

T

IT

LE

SE

C

O N

D T

IT

LE

G E N

ER

A L

BRYAN DYSON

ARCHITECT

LICENSE NO.: ##########

A-612 STOREFRONT AND WINDOW DETAILS

A-613 STOREFRONT AND WINDOW DETAILS

A-614 LOUVER TYPES AND DETAILS

A-701 PARTITION TYPES

A-702 PARTITION TYPES

A-711 PARTITION DETAILS

A-712 PARTITION DETAILS

A-713 PARTITION DETAILS

A-801 SIGNAGE PLAN - OVERALL

A-801a SIGNAGE PLAN - OVERALL - BID OPTION 2 & 3

A-811 SIGNAGE DETAILS

A-812 SIGNAGE TYPES

A-813 SIGNAGE SCHEDULE

INTERIORS

I-101 FINISH FLOOR PLAN - OVERALL

I-101a FINISH FLOOR PLAN - OVERALL - BID OPTION 2 & 3

I-102 FINISH FLOOR PLAN - AREA A

I-102a FINISH FLOOR PLAN - AREA A - BID OPTION 2

I-103 FINISH FLOOR PLAN - AREA B

I-104 FINISH FLOOR PLAN - AREA C

I-104a FINISH FLOOR PLAN - AREA C - BID OPTION 3

I-111 FURNITURE PLAN - OVERALL

I-111a FURNITURE PLAN - OVERALL - BID OPTION 2 & 3

I-112 FURNITURE PLAN - AREA A

I-112a FURNITURE FLOOR PLAN - AREA A - BID OPTION 2

I-113 FURNITURE PLAN - AREA B

I-114 FURNITURE PLAN - AREA C

I-114a FURNITURE FLOOR PLAN - AREA C - BID OPTION 3

SF124 ROOF FRAMING PLAN - AREA C

SF124a ROOF FRAMING PLAN - AREA C - BID OPTION 3

S-201 FRAMING ELEVATIONS

S-202 FRAMING ELEVATIONS

S-203 FRAMING ELEVATIONS

S-204 FRAMING ELEVATIONS

S-205 FRAMING ELEVATIONS

S-501 TYPICAL DETAILS

S-502 TYPICAL DETAILS

S-503 TYPICAL DETAILS

S-504 TYPICAL DETAILS

S-505 TYPICAL DETAILS

S-506 TYPICAL DETAILS

S-507 TYPICAL DETAILS

S-510 SECTIONS & DETAILS

S-521 SECTIONS & DETAILS

S-522 SECTIONS & DETAILS

S-523 SECTIONS & DETAILS

S-524 SECTIONS & DETAILS

ARCHITECTURAL

A-001 GENERAL NOTES

A-101 FLOOR PLAN - OVERALL

A-101a FLOOR PLAN - OVERALL - BID OPTION 2 & 3

A-102 FLOOR PLAN - AREA A

A-102a FLOOR PLAN - AREA A - BID OPTION 2

A-103 FLOOR PLAN - AREA B

A-104 FLOOR PLAN - AREA C

A-104a FLOOR PLAN - AREA C - BID OPTION 3

A-111 REFLECTED CEILING PLAN - OVERALL

A-111a REFLECTED CEILING PLAN - OVERALL - BID OPTION

2 & 3

A-112 REFLECTED CEILING PLAN - AREA A

A-112a REFLECTED CEILING PLAN - AREA A - BID OPTION 2

A-113 REFLECTED CEILING PLAN - AREA B

A-114 REFLECTED CEILING PLAN - AREA C

A-114a REFLECTED CEILING PLAN - AREA C - BID OPTION 3

A-121 ROOF PLAN - OVERALL

A-121a ROOF PLAN - OVERALL - BID OPTION 2 & 3

A-201 EXTERIOR ELEVATIONS - OVERALL

A-201a EXTERIOR ELEVATIONS - OVERALL - BID OPTION 2

& 3

A-202 EXTERIOR ELEVATIONS - PARTIALS - NORTH

A-202a EXTERIOR ELEVATIONS - PARTIALS - NORTH - BID

OPTION 2 & 3

A-203 EXTERIOR ELEVATIONS - PARTIALS - SOUTH

A-203a EXTERIOR ELEVATIONS - PARTIALS - SOUTH - BID

OPTION 2 & 3

A-204 EXTERIOR ELEVATIONS - PARTIALS - EAST & WEST

A-204a EXTERIOR ELEVATIONS - PARTIALS - EAST & WEST

- BID OPTION 2 & 3

A-301 BUILDING SECTIONS

A-301a BUILDING SECTIONS - BID OPTION 2 & 3

A-311 EXTERIOR WALL SECTIONS

A-312 EXTERIOR WALL SECTIONS

A-313 EXTERIOR WALL SECTIONS

A-314 EXTERIOR WALL SECTIONS

A-401 ENLARGED FLOOR PLANS

A-402 INTERIOR ELEVATIONS

A-403 INTERIOR ELEVATIONS

A-411 TOILET ACCESSORIES

A-501 EXTERIOR WALL DETAILS

A-502 EXTERIOR WALL DETAILS

A-503 EXTERIOR WALL DETAILS

A-511 ENLARGED PLAN DETAILS

A-512 ENLARGED PLAN DETAILS

A-513 ENLARGED PLAN DETAILS

A-521 EXTERIOR DETAILS

A-522 EXTERIOR DETAILS

A-531 INTERIOR DETAILS

A-532 INTERIOR DETAILS

A-533 INTERIOR DETAILS

A-534 INTERIOR DETAILS

A-535 INTERIOR DETAILS

A-536 INTERIOR DETAILS

A-537 INTERIOR DETAILS

A-601 ROOM FINISH SCHEDULE

A-602 FINISH MATERIAL LEGENDS

A-603 DOOR SCHEDULE

A-604 DOOR DETAILS

A-605 DOOR DETAILS

A-606 DOOR DETAILS

A-611 STOREFRONT AND WINDOW TYPES

GENERAL

G-000 COVER SHEET

G-001 DRAWING INDEX

G-002 LOCATION MAP / VICINITY MAP

G-003 GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS

G-100 LIFE SAFETY CODE SUMMARY

G-101 LIFE SAFETY PLAN - OVERALL

G-101a LIFE SAFETY PLAN - OVERALL - BID OPTION 2 & 3

G-111 SECURITY ZONE PLAN - OVERALL

G-111a SECURITY ZONE PLAN - OVERALL - BID OPTION 2 &

G-121 AIR BARRIER PLAN AND SECTION

G-121a AIR BARRIER PLAN AND SECTION - BID OPTION 2 &

TOPOGRAPHY

V-100 EXISTING CONDITIONS PLAN

CIVIL

B-001 BORING LOGS

C-001 CIVIL GENERAL NOTES AND LEGEND

C-002 EROSION AND SEDIMENT CONTROL NOTES

C-100 EROSION CONTROL PLAN

C-501 EROSION CONTROL DETAILS

C-900 SITE PHOTOS

CD100 SITE DEMOLITION PLAN

CD101 BUILDINGS 1274 AND 1276 SITE DEMOLITION PLAN

CS100 SITE PLAN - OVERALL

CS101 SITE PLAN - NW

CS102 SITE PLAN - NE

CS103 SITE PLAN - SW

CS104 SITE PLAN - SE

CP100 SIGNING AND MARKING PLAN - OVERALL

CP101 SIGNING AND MARKING PLAN - NW

CP102 SIGNING AND MARKING PLAN - NE

CP103 SIGNING AND MARKING PLAN - SW

CP104 SIGNING AND MARKING PLAN - SE

CP-501 PAVEMENT DETAILS

CP-502 SIGNING AND MARKING DETAILS

CG100 GRADING AND DRAINAGE PLAN OVERALL

CG101 GRADING AND DRAINAGE PLAN - NW

CG102 GRADING AND DRAINAGE PLAN - NE

CG103 GRADING AND DRAINAGE PLAN - SW

CG104 GRADING AND DRAINAGE PLAN - SE

CG105 BUILDING INTERMEDIATE GRADING PLAN

CG-201 STORM SEWER PROFILES

CG-301 SITE SECTIONS

CG-501 STORM DETAILS

CG-502 STORM DETAILS

CU100 OVERALL UTILITY PLAN

CU101 UTILITY PLAN - NW

CU102 UTILITY PLAN - NE

CU104 UTILITY PLAN - SE

CU-201 UTILITY PROFILES

CU-501 UTILITY DETAILS

CU-502 UTILITY DETAILS

LANDSCAPE ARCHITECTURE

LP100 PLANTING PLAN - OVERALL

LP101 ENLARGED PLANTING PLANS

LP501 PLANTING DETAILS

LP502 PLANTING SCHEDULE

STRUCTURAL

S-001 GENERAL NOTES

S-002 GENERAL NOTES

S-003 WIND LOADING DIAGRAM

S-004 SNOW LOADING DIAGRAM

SB101 FOUNDATION PLAN - OVERALL

SB101a FOUNDATION PLAN - OVERALL - BID OPTION 2 & 3

SB102 FOUNDATION PLAN - AREA A

SB102a FOUNDATION PLAN - AREA A - BID OPTION 2

SB103 FOUNDATION PLAN - AREA B

SB104 FOUNDATION PLAN - AREA C

SB104a FOUNDATION PLAN - AREA C - BID OPTION 3

SF121 ROOF FRAMING PLAN - OVERALL

SF121a ROOF FRAMING PLAN - OVERALL - BID OPTION 2 & 3

SF122 ROOF FRAMING PLAN - AREA A

SF122a ROOF FRAMING PLAN - AREA A - BID OPTION 2

SF123 ROOF FRAMING PLAN - AREA B

E-713 PANELBOARD SCHEDULES

E-714 PANELBOARD SCHEDULES

E-715 PANELBOARD SCHEDULES

E-716 PANELBOARD SCHEDULES

E-717 PANELBOARD SCHEDULES

E-718 PANELBOARD SCHEDULES

TELECOMMUNICATIONS

T-001 SYMBOLS, ABBREVIATIONS AND GENERAL NOTES

TS101 TELECOM SITE PLAN

T-100 TELECOM UNDERGROUND CONDUIT PLAN

T-101 TELECOM PLAN - OVERALL

T-101a TELECOM PLAN - OVERALL - BID OPTION 2 & 3

TT102 TELECOM PLAN - AREA A

TT102a TELECOM PLAN - AREA A - BID OPTION 2

TT103 TELECOM PLAN - AREA B

TT104 TELECOM PLAN - AREA C

TT104a TELECOM PLAN - AREA C - BID OPTION 3

TT112 TELECOM BASKET TRAY PLAN - AREA A

TT112a TELECOM BASKET TRAY PLAN - AREA A - BID

OPTION 2

TT113 TELECOM BASKET TRAY PLAN - AREA B

TT114 TELECOM BASKET TRAY PLAN - AREA C

TT122 TELECOM FIBER CABLE TRAY PLAN - AREA A

TT123 TELECOM FIBER CABLE TRAY PLAN - AREA B

TT124 TELECOM FIBER CABLE TRAY PLAN - AREA C

TT133 TELECOM PDS TRAY PLAN - AREA B

TT142 TELECOM UNDERGROUND BLACK CONDUIT PLAN -

AREA A

TT143 TELECOM UNDERGROUND BLACK CONDUIT PLAN -

AREA B

TT144 TELECOM UNDERGROUND BLACK CONDUIT PLAN -

AREA C

TT153 TELECOM UNDERGROUND RED CONDUIT PLAN -

AREA B

TT154 TELECOM UNDERGROUND RED CONDUIT PLAN -

AREA C

TT163 TELECOM UNDERGROUND PDS CONDUIT PLAN -

AREA B

TY102 SECURITY PLAN - AREA A

TY102a SECURITY PLAN - AREA A - BID OPTION 2

TY103 SECURITY PLAN - AREA B

TY104 SECURITY PLAN - AREA C

TY104a SECURITY PLAN - AREA C - BID OPTION 3

T-201 CABINET ELEVATIONS

T-202 CABINET ELEVATIONS

T-203 CABINET ELEVATIONS

T-204 CABINET ELEVATIONS

T-205 CABINET ELEVATIONS

T-206 CABINET ELEVATIONS

T-207 CABINET ELEVATIONS

T-208 CABINET ELEVATIONS

T-209 CABINET ELEVATIONS

T-210 WALL ELEVATIONS

T-211 CABINET CABLE TRAY SECTIONS

T-212 CABINET CABLE TRAY SECTIONS

T-401 ENLARGED TELECOM ROOM PLANS

T-402 ENLARGED TELECOM ROOM PLANS

T-403 ENLARGED TELECOM ROOM PLANS

T-404 ENLARGED TELECOM ROOM PLANS

T-405 ENLARGED TELECOM ROOM PLANS

T-501 SYSTEMS OUTLET DETAILS

T-502 SYSTEMS CABLE TRAY DETAILS

T-503 SYSTEMS CABLE TRAY DETAILS

T-504 GROUNDING DIAGRAM AND DETAILS

TY501 SECURITY DETAILS

TY502 SECURITY EQUIPMENT LIST AND DETAILS

T-601 VOICE AND DATA ONE-LINE DIAGRAM

T-602 3D RED PATHWAY SYSTEM

T-603 3D FIBER PATHWAY SYSTEM

T-604 3D PDS PATHWAY SYSTEM

T-605 3D BLACK PATHWAY SYSTEM

T-606 3D BLACK PATHWAY SYSTEM - BID OPTION 2

P-901 SANITARY WASTE AND VENT ISOMETRIC

P-902 DOMESTIC WATER ISOMETRIC

MECHANICAL

M-001 HVAC LEGEND, ABBREVIATIONS, AND SYMBOLS

M-002 HVAC LEGEND, GENERAL NOTES, AND

ABBREVIATIONS

M-101 HVAC FLOOR PLAN - OVERALL

M-101a HVAC FLOOR PLAN - OVERALL - OPTION 2 & 3

MH102 HVAC FLOOR PLAN - AREA A

MH102a HVAC FLOOR PLAN - AREA A - BID OPTION 2

MH103 HVAC FLOOR PLAN - AREA B

MH104 HVAC FLOOR PLAN - AREA C

MH104a HVAC FLOOR PLAN - AREA C - BID OPTION 3

MP102 HYDRONIC FLOOR PLAN - AREA A

MP102a HYDRONIC FLOOR PLAN - AREA A - BID OPTION 2

MP103 HYDRONIC FLOOR PLAN - AREA B

MP104 HYDRONIC FLOOR PLAN - AREA C

MP104a HYDRONIC FLOOR PLAN - AREA C - BID OPTION 3

M-301 HVAC BUILDING SECTIONS

M-302 HVAC BUILDING SECTIONS

M-401 HVAC ENLARGED PLANS

M-402 HVAC ENLARGED PLANS

M-403 HVAC ENLARGED PLANS

M-501 HVAC DETAILS

M-502 HVAC DETAILS

M-503 HVAC DETAILS

M-601 HVAC SCHEDULES

M-602 HVAC SCHEDULES

M-603 HVAC SCHEDULES

M-701 CHILLED WATER ONE LINE DIAGRAM

M-702 HOT WATER ONE LINE DIAGRAM

M-801 BAS ONE LINE CONTROL DIAGRAMS

M-802 BAS CONTROL DIAGRAMS

M-803 BAS CONTROL DIAGRAMS

M-804 BAS CONTROL DIAGRAMS

M-805 BAS CONTROL DIAGRAMS

M-806 BAS CONTROL POINTS

ELECTRICAL

E-001 GENERAL NOTES AND ABBREVIATIONS

E-002 SYMBOLS

ES101 SITE PLAN

EL101 LIGHTING PLAN - OVERALL

EL101a LIGHTING PLAN - OVERALL - BID OPTION 2 & 3

EL102 LIGHTING PLAN - AREA A

EL102a LIGHTING PLAN - AREA A - BID OPTION 2

EL103 LIGHTING PLAN - AREA B

EL104 LIGHTING PLAN - AREA C

EL104a LIGHTING PLAN - AREA C - BID OPTION 3

EP101 POWER AND EQUIPMENT PLAN - OVERALL

EP101a POWER AND EQUIPMENT PLAN - OVERALL - BID

OPTION 2 & 3

EP102 POWER PLAN - AREA A

EP102a POWER PLAN - AREA A - BID OPTION 2

EP103 POWER PLAN - AREA B

EP104 POWER PLAN - AREA C

EP104a POWER PLAN- AREA C - BID OPTION 3

EP112 EQUIPMENT PLAN - AREA A

EP112a EQUIPMENT PLAN - AREA A - BID OPTION 2

EP113 EQUIPMENT PLAN - AREA B

EP114 EQUIPMENT PLAN - AREA C

EP114a EQUIPMENT PLAN - AREA C - BID OPTION 3

E-201 EQUIPMENT ELEVATIONS

E-401 ENLARGED FLOOR PLANS

E-402 ENLARGED FLOOR PLANS

E-403 ENLARGED FLOOR PLANS

E-501 DETAILS

E-502 DETAILS

E-503 DETAILS

E-504 DETAILS

E-505 DETAILS

E-506 DETAILS

E-601 ONE-LINE DIAGRAM

E-602 ONE-LINE DIAGRAM

E-603 ONE-LINE DIAGRAMS

E-701 LIGHTING SCHEDULES

E-702 LIGHTING SCHEDULES

E-703 EQUIPMENT DATA SCHEDULE

E-704 EQUIPMENT DATA SCHEDULE

E-710 PANELBOARD SCHEDULES

E-711 PANELBOARD SCHEDULES

E-712 PANELBOARD SCHEDULES

FIRE PROTECTION

FS100 FIRE CODE COMPLIANCE SITE PLAN

FIRE ALARM

FA001 GENERAL NOTES, LEGENDS, AND ABBREVIATIONS

FA101 FLOOR PLAN - OVERALL

FA101A FLOOR PLAN - OVERALL BID OPTION 2&3

FA102 FLOOR PLAN - AREA A

FA102A FLOOR PLAN - AREA A - BID OPTION 2

FA103 FLOOR PLAN - AREA B

FA104 FLOOR PLAN - AREA C

FA104A FLOOR PLAN - AREA C - BID OPTION 3

FA501 DETAILS

FA502 DETAILS

FIRE SUPPRESSION

FX001 GENERAL NOTES, LEGENDS, AND ABBREVIATIONS

FX101 FLOOR PLAN - OVERALL

FX101A FLOOR PLAN - OVERALL - BID OPTION 2&3

FX102 FLOOR PLAN - AREA A

FX102A FLOOR PLAN - AREA A - BID OPTION 2

FX103 FLOOR PLAN - AREA B

FX104 FLOOR PLAN - AREA C

FX104A FLOOR PLAN - AREA C - BID OPTION 3

FX501 DETAILS

PLUMBING

P-001 SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES

P-101 FLOOR PLAN - OVERALL

P-101A FLOOR PLAN - OVERALL - BID OPTION 2 & 3

P-102 FLOOR PLAN - AREA A

P-102A FLOOR PLAN - AREA A - BID OPTION 2

P-103 FLOOR PLAN - AREA B

P-104 FLOOR PLAN - AREA C

P-104A FLOOR PLAN - AREA C - BID OPTION 3

P-401 ENLARGED PLAN

P-402 ENLARGED PLAN

P-403 ENLARGED PLAN

P-501 DETAILS

P-601 SCHEDULES

GENERAL

G-000 COVER SHEET

G-001 DRAWING INDEX

CEILING-MOUNTED SPEAKER/STROBE (XX DENOTES CANDELA RATING)

(Y DENOTES LENS COLOR; R=RED, BLANK=CLEAR)

WALL-MOUNTED SPEAKER/STROBE (XX DENOTES CANDELA RATING)

(WP DENOTES WEATHER PROOF DEVICE)

WALL-MOUNTED FIRE ALARM STROBE (XX DENOTES CANDELA RATING)

(WP DENOTES WEATHER PROOF DEVICE)

WALL-MOUNTED SPEAKER (WP DENOTES WEATHER PROOF DEVICE)

H/L

P

WP

FAMN

WP

FIRE ALARM AND MASS NOTIFICATION GENERAL NOTESFIRE ALARM AND MASS NOTIFICATION LEGEND

FIRE ALARM BELL

RADIO ALARM TRANSMITTER

WALL-MOUNTED EXTERIOR WEATHERPROOF SPEAKER

FIRE SERVICE TELEPHONE

HI/LOW AIR PRESSURE SWITCH

PRESSURE SWITCH

SPRINKLER TAMPER SWITCH

SPRINKLER FLOW SWITCH

DUCT SMOKE DETECTOR

PHOTOELECTRIC SMOKE DETECTOR

(P,A INDICATES PREACTION SYSTEM DEVICE)

MANUAL PULL STATION

HEAT DETECTOR

LOCAL OPERATING CONSOLE

NAC EXTENDER PANEL

FIRE ALARM SYSTEM ANNUNCIATOR

FIRE ALARM CONTROL PANEL, COMBINED WITH MASS NOTIFICATION

AUTONOMOUS CONTROL UNIT

AFF

AHJ

AVG

COTR

ELEV

EOL

FPC

MIN

NAC

NIC

NP

NC

SIM

SLC

SQFT

SP

TD

WP WEATHER PROOF

TRAVEL DISTANCE

SMOKE PARTITION

SQUARE FEET

SIGNALING LINE CIRCUIT

SIMILAR

NONCOMBUSTIBLE

NOT PERMITTED

NOT IN CONTRACT

NOTIFICATION APPLIANCE CIRCUIT

MINIMUM

FIRE PUMP CONTROLLER

END OF LINE RESISTOR

ELEVATION

CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE

AVERAGE

ABOVE FINISHED FLOOR

AUTHORITY HAVING JURISDICTION

FIRE ALARM ABBREVIATIONS

CARBON MONOXIDE DETECTORCO

POLE-MOUNTED CONE TYPE EXTERIOR WEATHERPROOF SPEAKER

CIS COMMON INTELLIGIBILITY LEVEL

DOR

AFG ABOVE FINISHED GRADE

DESIGNER OF RECORD

SD SMOKE DAMPER

SMOKE DAMPER

EX EXPLOSION PROOF

FIRE DEPARTMENT KEY LOCK BOX

1. PROVIDE AND INSTALL A COMPLETE COMBINED ADDRESSABLE FIRE ALARM AND MASS NOTIFICATION SYSTEM THROUGHOUT THE FACILITY IN ACCORDANCE WITH NFPA 72 AND AS INDICATED. CIRCUITS USED TO MONITOR AND CONTROL INITIATING DEVICES WILL BE INITIATING DEVICE CIRCUITS (IDC), CLASS B, OR SIGNALING LINE CIRCUITS (SLC), IN ACCORDANCE WITH NFPA 72. NETWORK CIRCUITS BETWEEN FIRE ALARM CONTROL PANELS, SUB PANELS, ANNUNCIATORS, ETC. WILL BE CLASS A IN ACCORDANCE WITH NFPA 72. CIRCUITS USED TO INITIATE OPERATION OF THE NOTIFICATION DEVICES WILL BE NOTIFICATION APPLIANCE CIRCUITS (NAC), CLASS B IN ACCORDANCE WITH NFPA 72. ALL FIRE ALARM CIRCUITS WILL BE MONITORED FOR CIRCUIT INTEGRITY (FAULT, SHORT AND GROUND) BY THE FIRE ALARM CONTROL PANEL. CIRCUIT FAILURE

SIGNALS WILL BE ANNUNCIATED AS TROUBLE SIGNALS.

2. DESIGN, INSTALL AND TEST THE FIRE ALARM/MASS NOTIFICATION SYSTEM IN ACCORDANCE WITH ANGETL 15-01-03, 01 MAY 2015; UFC 1-200-01, 20 JUNE 2016 EDITION; UFC 3-600-01, 10 MAY 2019 WITH CHANGE 3, 25 MARCH 2018; UFC 4-021-01 9 APRIL 2008 WITH CHANGE 1, JANUARY 2010; UFC 4-133-01 01 JUNE 2019 CHANGE 2, DECEMBER 2017, INTERNATIONAL BUILDING CODE, 2015 EDITION; NFPA 1, 2018 EDITION; NFPA 72, 2016 EDITION; NFPA 75, 2017 EDITION; AND NFPA 90A, 2015 EDITION.

3. FOR COMPLETE SYSTEM CONTROL, REFER TO FIRE ALARM LOGIC MATRIX ON SHEET FA501

4. PERFORM ALL ACCEPTANCE AND OPERATIONAL TESTS IN ACCORDANCE WITH NFPA 72.

5. A "RECORD OF COMPLETION", PREPARED IN ACCORDANCE WITH NFPA 72, AND THE FIRE ALARM TEST REPORT TO BE FILED

WITH THE LOCAL FIRE MARSHAL'S OFFICE.

6. THE FLASH RATE OF VISIBLE NOTIFICATION APPLIANCES SHALL NOT EXCEED TWO FLASHES PER SECOND, NOR BE LESS THAN ONE FLASH EVERY SECOND, IN ACCORDANCE WITH NFPA 72. A MAXIMUM PULSE DURATION SHALL BE 0.2 SECONDS WITH A MAXIMUM DUTY CYCLE OF 40 PERCENT, IN ACCORDANCE WITH NFPA 72. VISIBLE NOTIFICATION APPLIANCES SHALL

BE SPACED IN ACCORDANCE WITH NFPA 72 AND AS INDICATED.

7. VISUAL STROBE DEVICES WILL HAVE A MINIMUM 15-CANDELA RATING AND WILL BE LOCATED THROUGHOUT ALL COMMON AREAS OF THE OFFICES SUCH AS LOBBIES AND CORRIDORS. VISUAL DEVICES WILL ALSO BE LOCATED IN ALL TOILET ROOMS, CONFERENCE ROOMS, CLASSROOMS, ASSEMBLY AREAS, BREAK AREAS, ETC., AS REQUIRED FOR COMPLIANCE WITH THE ABA/ADA. CLEAR STROBES MARKED "ALERT" WILL BE USED TO INDICATE FIRE ALARMS AND MASS NOTIFICATION ALARMS IN ACCORDANCE WITH THE REQUIREMENTS OF UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS AND ECB 2018-17.

8. THE SPRINKLER SYSTEM CONTROL VALVE TAMPER AND FLOW SWITCHES SHALL BE CONNECTED TO THE SIGNALING LINE

CIRCUITS. REFER TO FIRE SUPPRESSION DRAWINGS FOR LOCATIONS.

9. OBTAIN APPROVALS FROM THE LOCAL FIRE MARSHAL'S OFFICE PRIOR TO COMMENCING WORK. SUBMIT SHOP DRAWINGS TO THE AHJ FOR APPROVAL. WORK SHALL NOT COMMENCE UNTIL APPROVAL OF THE SHOP DRAWINGS IS RECEIVED FROM THE AHJ. FIRE ALARM SYSTEM SHOP DRAWINGS, AT A MINIMUM, SHALL INCLUDE THE REQUIREMENTS OF NFPA 72, SECTION 7.4, 7.5, AND A.7.4.

10. AUDIBLE FIRE ALARM SOUND LEVEL SHALL BE AT LEAST 15 dBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS, WHICHEVER IS GREATER, MEASURED 5 FEET ABOVE THE FLOOR IN THE OCCUPIABLE AREA, BUT NOT GREATER THAN 120 dBA AT THE MINIMUM HEARING DISTANCE FROM THE AUDIBLE APPLIANCE. PROVIDE ADEQUATE NOTIFICATION APPLIANCES THROUGHOUT THE SPACE TO MEET NFPA

72 REQUIREMENTS.

11. AUDIBLE MASS NOTIFICATION REQUIREMENTS SHALL MEET THE CLARITY LEVELS OF UFC 4-021-01. (0.8 CIS MINIMUM)

12. ANY PENETRATIONS MADE THROUGH FIRE RATED PARTITIONS SHALL BE FIRE STOPPED WITH A U.L. LISTED SYSTEM. SUBMIT

PENETRATION LOCATION TO THE COTR FOR APPROVAL.

13. DUCT SMOKE DETECTORS FOR AIR HANDLING UNITS WILL BE SUPPLIED BY DIVISION 28 AND INSTALLED BY DIVISION 23.

14. FOR MINIMUM MOUNTING HEIGHTS ABOVE FINISHED FLOOR REFER TO DETAIL A1/FA501.

15. COORDINATE ALL FIRE PROTECTION, ELECTRICAL, PLUMBING, MECHANICAL, AND STRUCTURAL WORK WITH CEILING HEIGHTS, FURNITURE LAYOUT, AND ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR COORDINATE FINAL LOCATIONS

WITH ARCHITECT, AHJ, AND FIRE PROTECTION ENGINEER.

16. ALL TERMINATIONS SHALL BE AT A TERMINAL STRIP. ALL DEVICES SHALL HAVE SCREW TERMINALS. IDENTIFY ALL CONDUCTORS INDIVIDUALLY WITH PERMANENT MARKINGS. THE USE OF WIRE NUTS SHALL NOT BE ALLOWED.

17. CONDUCTORS (WIRE) FOR ALL FIRE DETECTION AND ALARM CIRCUITS WILL BE INSTALLED WITHIN ¾-INCH MINIMUM DIAMETER METAL CONDUIT. ALL SIGNALING LINE AND INITIATING DEVICE CIRCUITS SHALL BE MINIMUM 16 GAUGE WIRE.

18. FIRE ALARM SYSTEM COMPONENTS ARE TO BE IDENTIFIED IN ACCORDANCE WITH UFC 3-600-01, 9-18.9.7. ALL CONDUIT, JUNCTION/BACK BOXES, COVERS AND COUPLINGS , WHEN PROVIDED, MUST BE FACTORY PAINTED RED IN UNFURNISHED AREAS (E.G., ABOVE CEILINGS, MECHANICAL ROOMS, ETC.). ALL CONDUIT, JUNCTION/BACK BOXES, COVERS AND COUPLINGS, WHEN PROVIDED, ARE PERMITTED TO BE PAINTED TO MATCH THE ROOM FINISHING IN FINISHED AREAS. THE INSIDE COVER OF THE JUNCTION BOX MUST BE IDENTIFIED AS "FIRE ALARM" AND THE CONDUIT MUST HAVE PAINTED RED BANDS 3/4 -IN. (20 MM) WIDE AT 20 FT (6 M) INTERVALS AND ON BOTH SIDES OF ALL FLOOR, WALL, AND CEILING PENETRATIONS. PROVIDE TYPE THW OR XHHW FOR WIRING IN WET LOCATIONS. TYPE THWN/THHN INSULATED WIRE IS NOT ACCEPTABLE FOR

UNDERGROUND WIRING OF FIRE ALARM CIRCUITS .

19. DRAWINGS INDICATE THE DESIGN INTENT. IT IS THE CONTRACTOR'S RESPONSIBILITY UNDER THE SCOPE OF WORK TO COMPLY WITH ALL CODES / STANDARDS SPECIFIED ABOVE TO ACCOMMODATE SPACE CONFIGURATION FOR NEW CONSTRUCTION INCLUSIVE OF NOTIFICATION COVERAGE, REMOTE MONITORING, CONTROLS, ACCESSORIES, AND ALL ACCEPTANCE TESTS / APPROVALS FOR A COMPLETE, FULLY COMPLIANT, AND FUNCTIONAL SYSTEM. SUBMIT SHOP

DRAWINGS IN COMPLIANCE WITH NFPA 72 TO THE AHJ FOR APPROVAL.

20. THESE DRAWINGS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN LAYOUT TO BE UTILIZED AS GUIDANCE FOR THE PLANNING OF THE FIRE ALARM SYSTEM BY THE CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL BY THE ENGINEER AND AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE IN THE SHOP DRAWINGS AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY, INCLUDING INITIATING DEVICES AND NOTIFICATION APPLIANCES, TO PROVIDE A COMPLETE INSTALLATION AND COMPLY WITH BASE STANDARDS.

21. PROVIDE ADDRESSABLE CONTROL MODULES AT LIGHTING CONTROL PANEL TO ENERGIZE EGRESS LIGHTING CONTROLLED

BY OCCUPANCY SENSORS UPON FIRE ALARM SIGNAL.

22. A CONTROLLED ZONE IS IDENTIFIED FOR USE IN THIS FACILITY AS SHOWN ON DRAWING G-111. THE FIRE ALARM CONTROL PANEL WITHIN THE CONTROLLED ZONE SHALL ONLY BE USED TO SERVE EQUIPMENT IN THAT RESPECTIVE ZONE. UNLESS OTHERWISE NOTED, CONDUITS AND CABLES CROSSING THROUGH CONTROLLED ZONES SHALL CROSS UNDER THE SLAB (FIRST FLOOR) OR GO COMPLETELY AROUND. DO NOT CROSS CONTROLLED ZONES UNLESS SPECIFICALLY IDENTIFIED.

ARCHITECTURAL DRAWINGS IDENTIFY THE STC RATINGS FOR ALL WALLS. CONDUIT AND DEVICE BOX PENETRATIONS IN SOUND RATED WALLS SHALL BE MINIMIZED, AND WHERE REQUIRED, SHALL BE TREATED TO MAINTAIN THE RATING OF THE ASSEMBLY. THOSE DEVICE BOXES MOUNTED ON THE OPPOSITE SIDES OF A RATED WALL SHALL BE STAGGERED AND NOT MOUNTED BACK TO BACK IN ORDER TO MAINTAIN THE PARTITION STC RATING. CONDUITS ENTERING A CONTROLLED ZONE THROUGH A WALL SHALL BE GROUPED TOGETHER AND LOCATED WHERE EASILY ACCESSIBLE ON THE SECURE SIDE OF THE

WALL.

XX

XX

WP

XX

WP

WP

P

GRAPHIC ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

TEMPERATURE SENSOR

CEILING-MOUNTED STROBE (XX DENOTES CANDELA RATING)

(Y DENOTES LENS COLOR; R=RED BLANK=CLEAR)

XX

REMOTE MASS NOTIFICATION LED TEXT DISPLAY

VERY EARLY WARNING SMOKE DETECTION SYSTEM (VEWSD)

EMERGENCY SHOWER/EYEWASH STATION FLOW SWITCH

CONTROL MODULE

MONITOR MODULE

WALL-MOUNTED HORN/STROBE (XX DENOTES CANDELA RATING)

XX

CEILING-MOUNTED SPEAKER

RADIO TRANSMITTER ANTENNA

WALL-MOUNTED SPEAKER/STROBE (XX DENOTES CANDELA RATING)

(XP DENOTES EXPLOSION PROOF DEVICE)

XX

XP

DIGITAL CELLULAR COMMUNICATOR PANEL

WIDE AREA MASS NOTIFICATION REMOTE INTERFACE CONTROLLER

FACP

DCCP

WAMN

FSA

GAN

NAC

LOC

LED

VD

EW

MM

CM

F

K

NOT ALL SYMBOLS USED

SD

RAT

M

M

T

Y

Y

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

J A

C O

B S

D

U L L E

S C

O R

N E

R P

A R

K S

U

IT

E

H E

R N

D O

N V

A

U T

A H

T E

S T

A N

D T

R A

IN

IN

G R

A N

G E

U

T T

R

C O

N S

O L

ID

A

T E

D M

IS

S

IO

N

C O

N T

R O

L C

E N

T E

R

C M

C C

H

IL

L

A

IR

F O

R C

E B

A S

E

U T

A H

S

E P

T E

M B

E R

P

W P

P -1

-D

-0

FA001

G E

N E

R A

L N

O T

E S

L

E G

E N

D S

A

N D

A B

B R

E V

IA

T

IO

N

S

J F

O U

L K

R S

A L L

W A

S S

E R

M R

A H

M A

N

W C

L A

Y

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

F

IR

E A

L A

R M

JASON FOULK

FIRE PROTECTION ENGINEER

LICENSE NO.: ########

X

X

X

IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII

I I

I I I

I I I

I I I

I I I

III

IIIIIIIIIIIIIIIIIIIIIIII

III

III

I I I

I I I

I I I

I I I

I I I

I I I

I I I

I I I

III

III

I I I

I I I

I I I

III

III

I I I

III

III

III

III

III

III

X

X

X

X

X

X

X

X

X

X

X

X

X

W W W W W W W W W W W W W W W W W W W W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

CO

IIIIIIIIIIII

III

I I I

I I I

I I I ss ss ss

12"

8"

8"

+4748.4

+4748.5

WWWWW

FH

FH

FH

FH

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A

R M

Y

C

O R

P

O

F

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

C T

N

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R I P

T I O

N

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

S A

C R

A M

E N

D

I S

T R

I C

T

J

S

T R

E E

T

S

A C

R A

M E

N T

O

C

A

J A

C O

B S

D

U L L E

S

C

O R

N E

R

P

A R

K

S

U I T

E

H E

R N

D O

N

V

A

U T

S

T

A

A

I N

I N

G

R

A N

G

T T

R

C O

N S

O L

I D

A T

M

S

S I O

N

C

O N

T R

L

N

T E

R

C

M C

C

H I L

L

A

R

B

S

E

U

T A

H

S

E P

T E

M B

P

W P

P D

HOWARD LUSK

PROFESSIONAL ENGINEER

LICENSE NO.: 034029

H

L U

S K

H L

J F

M

R

A H

M A

N

J

C

O R

U M

N

KEYED NOTES

GENERAL SHEET NOTES

A. SEE SHEET C-001 FOR PROPOSED NOTES AND LEGEND, V-001 FOR

EXISTING.

B. SEE CU-101 TO CU-104 FOR NEW UTILITIES, REPLACEMENT FIRE

HYDRANTS, FIRE DEPARTMENT CONNECTION

C. THIS SHEET DEMONSTRATES COMPLIANCE WITH THE APPLICABLE

REQUIREMENTS OF UFC 3-600-01 PARAGRAPH 1-7.2.4.2 CODE

COMPLIANCE SITE PLAN.

D. FLOW TEST HYDRANT LOCATIONS:

STATIC PRESSURE TEST HYDRANT IS SHOWN BY CALLOUT ON THIS SHEET.

FLOW TEST FLOW HYDRANT IS LOCATED 298 FEET TO THE SOUTH EAST

ALONG THE UNAMED STREET. BOTH HYDRANTS ARE CONNECTED TO THE

SAME 12" WATER MAIN.

1. FIRE HYDRANT

2. FIRE DEPARTMENT CONNECTION

3. MAIN ENTRANCE TO BUILDING

4. DIESEL POWERED GENERATOR

5. PAD MOUNTED TRANSFORMER

6. NATURAL GAS METER AND SHUTOFF

7. DROP ARM BARRIER

8. INDICATING CONTROL VALVE WITHIN FIRE-RATED ROOM.

9. EXTERIOR ACCESS DOOR LEADING TO FIRE SPRINKLER SYSTEM

INDICATING CONTROL VALVE.

0 40 80 120

1"=40'

FS100

F I R

E

C

O D

E

C

O M

P L

I A

N C

E

S I T

E

P

L A

N

CMCC

U

N

N

A

M

E

D

S

T

R

E

E

T

U

N

N

A

M

E

D

S

T

R

E

E

T

6TH STREET

B

A

L

M

V

E

N

U

E

D

U

L

V

E

N

U

E

R

E

E

T

R

E

E

T

33' AT

STANDOFF

12"W

8"W

8"W

6"W

12"W

12"W

SEE NOTE D

M

Y

C

O R

P

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

D A

T E

M A

R K

D E

S C

R I P

T I O

N

S A

C R

A M

E N

S

T R

I C

T

J

S

T R

E E

T

S

A C

R A

M E

N T

O

C

A

J A

C O

B S

D

U L L E

S

C

O R

N E

R

P

A R

K

S

U I T

E

H E

R N

D O

N

V

A

S

E P

T E

M B

P

W P

P D

H

L U

S K

H L

J F

M

R

A H

M A

N

J

C

O R

M

WP

WP

W P

W P

W P

W P

W P

W P

A

C

D

K

2 3 4

5.3

6 8 9 10

J

B

H

G

F

3.9 5

E

G.8

G.6

6.7 7.47.2

FA102

A1

FA103

A1

FA104

A1

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A B

C

KEYPLAN

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

J A

C O

B S

D

U L L E

S C

O R

N E

R P

A R

K S

U

IT

E

R N

D O

N V

A

U T

A H

T E

S T

A N

D T

R A

IN

IN

G R

A N

G E

U

T T

R

C O

N S

O L

ID

A

T E

D M

IS

S

IO

N

C O

N T

R O

L C

E N

T E

R

C M

C C

H

IL

L

A

IR

F O

R C

E B

A S

E

U T

A H

S

E P

T E

M B

E R

P

W P

P -1

-D

-0

FA101

F L

O O

R P

L A

N

O V

E R

A L

L

J F

O U

L K

R S

A L L

W A

S S

E R

M R

A H

M A

N

W C

L A

Y

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

F

IR

E A

L A

R M

JASON FOULK

FIRE PROTECTION ENGINEER

LICENSE NO.: ########

0 8' 16' 32'

SCALE: 1/16" = 1'-0"

PLAN NORTH

1/16" = 1'-0"A1

FLOOR PLAN - FIRE ALARM OVERALL

GENERAL NOTES

1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT

ACTUAL BUILDING CIRCUITING. REFER TO CONTRACTOR'S

DESIGN DRAWINGS FOR ACTUAL DEVICE LOCATION.

3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED

LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED

POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.

4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.

FINAL QUANTITY AND LAYOUT SHALL BE IN

ACCORDANCE WITH APPLICABLE CODES,

MANUFACTURER'S RECOMMENDATIONS, AND

EQUIPMENT LISTINGS.

5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND

HVAC SYSTEMS.

6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT

SPECIFICATIONS AND NFPA 72.

7. USE CLEAR LENS STROBES MARKED "ALERT" FOR FIRE

ALARM AND MASS NOTIFICATION SYSTEM.

8. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY

TO TEMPORARILY DEACTIVATE THE FIRE ALARM AUDIO

AND VISUAL NOTIFICATION APPLIANCES WHILE

DELIVERING VOICE MESSAGES.

9. MOUNT ALL INTERIOR FA/MNS DEVICES AT 80" TO 96" AFF

AND COORDINATE MOUNTING LOCATION WITH

ARCHITECTURAL DRAWINGS.

10. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND

COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL

DRAWINGS.

11. FIRE ALARM SYSTEM SHALL BE GROUNDED IN

ACCORDANCE WITH ALL APPLICABLE CODES AND

STANDARDS.

KEYED NOTES #

WP

W P

W P

W P

W P

W P

W P

A

C

D

K

1 2 3 4

5.3

6 8 9 10

J

B

H

G

F

3.9 5

E

G.8

G.6

6.7 7.47.2

FA102A

A1

FA104A

A1

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A B

C

KEYPLAN

B

ID

O P

T

IO

N

B

ID

O P

T

IO

N

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

J A

C O

B S

D

U L L E

S C

O R

N E

R P

A R

K S

U

IT

E

R N

D O

N V

A

U T

A H

T E

S T

A N

D T

R A

IN

IN

G R

A N

G E

U

T T

R

C O

N S

O L

ID

A

T E

D M

IS

S

IO

N

C O

N T

R O

L C

E N

T E

R

C M

C C

H

IL

L

A

IR

F O

R C

E B

A S

E

U T

A H

S

E P

T E

M B

E R

P

W P

P -1

-D

-0

FA101A

F L

O O

R P

L A

N

O V

E R

A L

L B

ID

O

P T

IO

N

J F

O U

L K

R S

A L L

W A

S S

E R

M R

A H

M A

N

W C

L A

Y

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

F

IR

E A

L A

R M

JASON FOULK

FIRE PROTECTION ENGINEER

LICENSE NO.: ########

1/16" = 1'-0"A1

FLOOR PLAN - FIRE ALARM OVERALL BID OPTION 2 & 3

0 8' 16' 32'

SCALE: 1/16" = 1'-0"

PLAN NORTH

GENERAL NOTES

1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT

ACTUAL BUILDING CIRCUITING. REFER TO CONTRACTOR'S

DESIGN DRAWINGS FOR ACTUAL DEVICE LOCATION.

3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED

LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED

POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.

4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.

FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE

WITH APPLICABLE CODES, MANUFACTURER'S

RECOMMENDATIONS, AND EQUIPMENT LISTINGS.

5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND

HVAC SYSTEMS.

6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT

SPECIFICATIONS AND NFPA 72.

7. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO

TEMPORARILY DEACTIVATE THE FIRE ALARM AUDIO AND

VISUAL NOTIFICATION APPLIANCES WHILE DELIVERING

VOICE MESSAGES.

8. MOUNT ALL INTERIOR FA/MNS WALL MOUNTED DEVICES

AT 80" TO 96" AFF AND COORDINATE MOUNTING LOCATION

WITH ARCHITECTURAL DRAWINGS.

9. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND

COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL

DRAWINGS.

10. FIRE ALARM SYSTEM SHALL BE GROUNDED IN

ACCORDANCE WITH ALL APPLICABLE CODES AND

KEYED NOTES #

M N

F

L O

C

L O

C F

S A

P

WP

F

F F F

R A

T

CO

CO

30 15

110 110

75 75

75 75

N A

C

LED

LED

LED

N A

C

V D

P

P

VD

W P

W P

W P

W P

M M

MM

MM

MM

MM

MM

CM

CM

CM

MM

MM

CM

MM

CM

CM

F A

M N

CM

CM

C

D

K

2 3 4

5.3

J

H

G

F

3.9 5

E

LOBBY

BREAK ROOM

WOMEN

JAN

MEN

MECHANICAL

ROOM

CLASSROOM /

CONF

SOFT. DEV.

EQUIPMENT

BOILER ROOM

WOMEN

JAN

MEN

ELECTRICAL

UTTR COMM

CORRIDOR

C102

VESTIBULE

UPS ROOM

CORRIDOR

C101

SOFT. DEV.

GOV OFFICE 4

GOV OPEN

OFFICE

JT4 OPEN

OFFICE

VESTIBULE

PACKING

GOV OFFICE 1

GOV OFFICE 2

GOV OFFICE 3

ELECTRICAL

JT4 OFFICE

122A

STAN-EVAL

TESTING

WELLNESS

4(TYP. OF 4)

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

KEYPLAN

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

J A

C O

B S

D

U L L E

S C

O R

N E

R P

A R

K S

U

IT

E

R N

D O

N V

A

U T

A H

T E

S T

A N

D T

R A

IN

IN

G R

A N

G E

U

T T

R

C O

N S

O L

ID

A

T E

D M

IS

S

IO

N

C O

N T

R O

L C

E N

T E

R

C M

C C

H

IL

L

A

IR

F O

R C

E B

A S

E

U T

A H

S

E P

T E

M B

E R

P

W P

P -1

-D

-0

FA102

F L

O O

R P

L A

N

A R

E A

A

J F

O U

L K

R S

A L L

W A

S S

E R

M R

A H

M A

N

W C

L A

Y

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

F

IR

E A

L A

R M

JASON FOULK

FIRE PROTECTION ENGINEER

LICENSE NO.: ########

8'4' 16'0

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL NOTES

1 PROVIDE VERY EARLY WARNING SMOKE DETECTION (VEWSD) FOR IT AREA

IN ACCORDANCE WITH NFPA 75.

2 FIRE ALARM RADIO ANTENNA

3 MONACO BT2-8NB (16/32 ZONE)

4 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH CONTROL VALVE

TAMPER SWITCH TO FIRE ALARM SYSTEM FOR SUPERVISORY FUNCTION.

VERIFY LOCATION WITH SPRINKLER CONTRACTOR.

5 PROVIDE CARBON MONOXIDE DETECTION IN ACCORDANCE WITH UFC

3-600-01, NFPA 720 AND MANUFACTURER'S REQUIREMENTS.

6 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR INTERFACE

WITH SUPPLY SIDE DUCT SMOKE DETECTOR. INSTALL EQUIPMENT AT

MANUFACTURER'S PROVIDED CONTACTS (REFER TO MECHANICAL

DRAWINGS FOR LOCATION). MOUNT DEVICE IN ACCORDANCE WITH

MANUFACTURER'S REQUIREMENTS, NFPA 72, AND NFPA 90A. CONNECTIONS

TO FIRE ALARM SYSTEM SHALL BE PROVIDED BY DIVISION 28.

CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY DIVISION 23.

7 PROVIDE SEPARATE MONITOR MODULES AS NECESSARY FOR MONITORING

OF EACH ALARM, TROUBLE, AND SUPERVISORY FUNCTION OF THE VEWSD

SYSTEM.

8 ADDRESSABLE CONTROL MODULE FOR SHUTDOWN OF CRAC UNIT UPON

VEWSD LEVEL 3 ALARM.

9 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH FLOW SWITCH TO

FIRE ALARM PANEL FOR ALARM FUNCTION.

10 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR INTERFACE

WITH SMOKE DAMPER DUCT SMOKE DETECTOR. MOUNT DEVICE IN

ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS, NFPA 72, AND

NFPA 90A. CONNECTIONS TO FIRE ALARM SYSTEM SHALL BE PROVIDED BY

DIVISION 28. CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY

DIVISION 23.

11 VEWSD MONITORING STATION.

KEYED NOTES #

1/8" = 1'-0"A1

FLOOR PLAN - FIRE ALARM AREA A

1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.

2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT ACTUAL BUILDING

CIRCUITING. REFER TO CONTRACTOR'S DESIGN DRAWINGS FOR ACTUAL

DEVICE LOCATION.

3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED LETTER "FIRE ALARM

CIRCUIT" ON THE DEDICATED POWER CIRCUIT BREAKER AND/OR

DISCONNECT SWITCH.

4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS. FINAL QUANTITY AND

LAYOUT SHALL BE IN ACCORDANCE WITH APPLICABLE CODES,

MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS.

5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND HVAC SYSTEMS.

6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT SPECIFICATIONS AND NFPA

72.

7. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO TEMPORARILY

DEACTIVATE THE FIRE ALARM AUDIO AND VISUAL NOTIFICATION APPLIANCES

WHILE DELIVERING VOICE MESSAGES.

8. REFER TO A1/FA501 FOR MOUNTING HEIGHTS OF ALL INTERIOR FA/MNS WALL

MOUNTED DEVICES AND COORDINATE MOUNTING LOCATION WITH

ARCHITECTURAL DRAWINGS.

9. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND COORDINATE

MOUNTING LOCATION WITH ARCHITECTURAL DRAWINGS.

10. FIRE ALARM SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH ALL

APPLICABLE CODES AND STANDARDS.

M N

F

L O

C

L O

C F

S A

P

WP

F

F F F

R A

T

CO

CO

30 15

110 110

75 75

75 75

N A

C

LED

LED

LED

N A

C

V D

P

P

VD

FLED

W P

W P

W P

W P

M M

MM

MM

MM

MM

MM

CM

CM

CM

MM

MM

CM

MM

CM

CM

F A

M N

CM

CM

C

D

K

1 2 3 4

5.3

J

H

G

F

3.9 5

E

LOBBY

BREAK ROOM

WOMEN

JAN

MEN

MECHANICAL

ROOM

CLASSROOM /

CONF

SOFT. DEV.

EQUIPMENT

124 BOILER ROOM

WOMEN

JAN

MEN

ELECTRICAL

UTTR COMM

VESTIBULE

UPS ROOM

CORRIDOR

C101

GOV OFFICE 6

GOV OFFICE 7

GOV OFFICE 4

JT4 OPEN

OFFICE

GOV OPEN

OFFICE

SOFT. DEV.

GOV OFFICE 3

GOV OFFICE 2

GOV OFFICE 1

PACKING

ELECTRICAL

JT4 OFFICE

122A

STAN-EVAL

TESTING

WELLNESS

157GOV OFFICE 5

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

KEYPLAN

B

ID

O P

T

IO

N

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

J A

C O

B S

D

U L L E

S C

O R

N E

R P

A R

K S

U

IT

E

R N

D O

N V

A

U T

A H

T E

S T

A N

D T

R A

IN

IN

G R

A N

G E

U

T T

R

C O

N S

O L

ID

A

T E

D M

IS

S

IO

N

C O

N T

R O

L C

E N

T E

R

C M

C C

H

IL

L

A

IR

F O

R C

E B

A S

E

U T

A H

S

E P

T E

M B

E R

P

W P

P -1

-D

-0

FA102A

F L

O O

R P

L A

N

A R

E A

A

B

ID

O P

T

IO

N

J F

O U

L K

R S

A L L

W A

S S

E R

M R

A H

M A

N

W C

L A

Y

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

F

IR

E A

L A

R M

JASON FOULK

FIRE PROTECTION ENGINEER

LICENSE NO.: ########

8'4' 16'0

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL NOTES

1 PROVIDE VERY EARLY WARNING SMOKE DETECTION (VEWSD) FOR IT

AREA IN ACCORDANCE WITH NFPA 75.

2 MONACO BT2-8NB (16/32 ZONE)

3 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH CONTROL

VALVE TAMPER SWITCH TO FIRE ALARM SYSTEM FOR SUPERVISORY

FUNCTION. VERIFY LOCATION WITH SPRINKLER CONTRACTOR.

4 PROVIDE CARBON MONOXIDE DETECTION IN ACCORDANCE WITH UFC

3-600-01, NFPA 720 AND MANUFACTURER'S REQUIREMENTS.

5 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR INTERFACE

WITH SUPPLY SIDE DUCT SMOKE DETECTOR. INSTALL EQUIPMENT AT

MANUFACTURER'S PROVIDED CONTACTS (REFER TO MECHANICAL

DRAWINGS FOR LOCATION). MOUNT DEVICE IN ACCORDANCE WITH

MANUFACTURER'S REQUIREMENTS, NFPA 72, AND NFPA 90A.

CONNECTIONS TO FIRE ALARM SYSTEM SHALL BE PROVIDED BY DIVISION

28. CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY

DIVISION 23.

6 PROVIDE SEPARATE MONITOR MODULES AS NECESSARY FOR

MONITORING OF EACH ALARM, TROUBLE, AND SUPERVISORY FUNCTION

OF THE VEWSD SYSTEM.

7 ADDRESSABLE CONTROL MODULE FOR SHUTDOWN OF CRAC UNIT UPON

VEWSD LEVEL 3 ALARM.

8 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH FLOW SWITCH

TO FIRE ALARM PANEL FOR ALARM FUNCTION.

9 FIRE ALARM RADIO ANTENNA

10 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR INTERFACE

WITH SMOKE DAMPER DUCT SMOKE DETECTOR. MOUNT DEVICE IN

ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS, NFPA 72, AND

NFPA 90A. CONNECTIONS TO FIRE ALARM SYSTEM SHALL BE PROVIDED

BY DIVISION 28. CONNECTIONS TO HVAC EQUIPMENT SHALL BE

PROVIDED BY DIVISION 23.

11 VEWSD MONITORING STATION.

KEYED NOTES #

1/8" = 1'-0"A1

FLOOR PLAN - FIRE ALARM AREA A - BID OPTION 2

1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND GENERAL NOTES.

2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT ACTUAL BUILDING

CIRCUITING. REFER TO CONTRACTOR'S DESIGN DRAWINGS FOR ACTUAL

DEVICE LOCATION.

3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED LETTER "FIRE ALARM

CIRCUIT" ON THE DEDICATED POWER CIRCUIT BREAKER AND/OR

DISCONNECT SWITCH.

4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS. FINAL QUANTITY

AND LAYOUT SHALL BE IN ACCORDANCE WITH APPLICABLE CODES,

MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS.

5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND HVAC SYSTEMS.

6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT SPECIFICATIONS AND

NFPA 72.

7. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO TEMPORARILY

DEACTIVATE THE FIRE ALARM AUDIO AND VISUAL NOTIFICATION

APPLIANCES WHILE DELIVERING VOICE MESSAGES.

8. REFER TO A1/FA501 FOR MOUNTING HEIGHTS OF ALL INTERIOR FA/MNS

WALL MOUNTED DEVICES AND COORDINATE MOUNTING LOCATION WITH

ARCHITECTURAL DRAWINGS.

9. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND COORDINATE

MOUNTING LOCATION WITH ARCHITECTURAL DRAWINGS.

10. FIRE ALARM SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH ALL

APPLICABLE CODES AND STANDARDS.

11. HALFTONE INDICATES DEVICES ARE INCLUDED AS PART OF BASE BID.

OTHER DEVICES ARE IN ADDITION TO OR RELOCATED FROM BASE BID AS

PART OF ABI 2.

F F

F

30 30

15 15 15

15 15

L E

D L E

D

LED

VD

VD

V D

V D

V D

V D

W P

MM

M M

M M

M M

M M

M M

CM

MM

CM

MM

CM

MM

MM

CM

MM

CM

MM

PF

A

M N

CM

CM

CM

CM

CM

CM

CMCM

CM

CM

K

6 8 9 10

J

H

G

E

G.8

G.6

6.7 7.47.2

TM1

MCR 1

MCR 1 VIP

VIDEO

SUPPORT

MCR 2

MCR 2 VIP

VIDEO ROOM

ELECTRICAL

TSPI

COMM VAULT

SCR / GUEST

BREAK ROOM

TELEMETRY

(TM1)

TELEMETRY

(TM2)

VIDEO ROOM

TSPI

CONFERENCE

(SECURE)

POST FLIGHT

CORRIDOR

C102

CORRIDOR

C104

TM2

CORRIDOR

C103

VESTIBULE

VESTIBULE

VESTIBULE

RMF

5 5

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

B

KEYPLAN

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

J A

C O

B S

D

U L L E

S C

O R

N E

R P

A R

K S

U

IT

E

R N

D O

N V

A

U T

A H

T E

S T

A N

D T

R A

IN

IN

G R

A N

G E

U

T T

R

C O

N S

O L

ID

A

T E

D M

IS

S

IO

N

C O

N T

R O

L C

E N

T E

R

C M

C C

H

IL

L

A

IR

F O

R C

E B

A S

E

U T

A H

S

E P

T E

M B

E R

P

W P

P -1

-D

-0

FA103

F L

O O

R P

L A

N

A R

E A

B

J F

O U

L K

R S

A L L

W A

S S

E R

M R

A H

M A

N

W C

L A

Y

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

F

IR

E A

L A

R M

JASON FOULK

FIRE PROTECTION ENGINEER

LICENSE NO.: ########

8'4' 16'0

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL NOTES

KEYED NOTES #

1 PROVIDE VERY EARLY WARNING SMOKE DETECTION (VEWSD)

FOR IT AREA IN ACCORDANCE WITH NFPA 75.

2 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH

CONTROL VALVE TAMPER SWITCH TO FIRE ALARM SYSTEM

FOR SUPERVISORY FUNCTION. VERIFY LOCATION WITH

SPRINKLER CONTRACTOR.

3 ADDRESSABLE CONTROL MODULE FOR SHUTDOWN OF CRAC

UNIT UPON VEWSD LEVEL 3 ALARM.

4 PROVIDE SEPARATE MONITOR MODULES AS NECESSARY FOR

MONITORING OF EACH ALARM, TROUBLE, AND SUPERVISORY

FUNCTION OF THE VEWSD SYSTEM.

5 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR

INTERFACE WITH SMOKE DAMPER DUCT SMOKE DETECTOR.

MOUNT DEVICE IN ACCORDANCE WITH MANUFACTURER'S

REQUIREMENTS, NFPA 72, AND NFPA 90A. CONNECTIONS TO

FIRE ALARM SYSTEM SHALL BE PROVIDED BY DIVISION 28.

CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY

DIVISION 23.

6 MOUNT VISUAL NOTIFICATION DEVICE ABOVE EQUIPMENT

PLATFORM.

1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

2. REFER TO FA101 FOR FIRE ALARM OVERALL PLAN.

3. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT

ACTUAL BUILDING CIRCUITING. REFER TO CONTRACTOR'S

DESIGN DRAWINGS FOR ACTUAL DEVICE LOCATION.

4. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED

LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED

POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.

5. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.

FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE

WITH APPLICABLE CODES, MANUFACTURER'S

RECOMMENDATIONS, AND EQUIPMENT LISTINGS.

6. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND

HVAC SYSTEMS.

7. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT

SPECIFICATIONS AND NFPA 72.

8. USE CLEAR LENS STROBES MARKED "ALERT" FOR FIRE

ALARM AND MASS NOTIFICATION SYSTEM.

9. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO

TEMPORARILY DEACTIVATE THE FIRE ALARM AUDIO AND

VISUAL NOTIFICATION APPLIANCES WHILE DELIVERING

VOICE MESSAGES.

10. REFER TO A1/FA501 FOR MOUNTING HEIGHTS OF ALL

INTERIOR FA/MNS WALL MOUNTED DEVICES AND

COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL

DRAWINGS.

11. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND

COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL

DRAWINGS.

12. FIRE ALARM SYSTEM SHALL BE GROUNDED IN

ACCORDANCE WITH ALL APPLICABLE CODES AND

STANDARDS.

1/8" = 1'-0"A1

FLOOR PLAN - FIRE ALARM AREA B

L E

D

R R

R R

W P

VD

VD

MM

M M

MM

CM

MM CM

CM

CM

CM

CM CM

FF

CM

A

C

6 8 9 107

B

AOC OPS

AOC OPS

AOC COMM

HRC

CORRIDOR

C105

LINK 16

5 6

6 6

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C

KEYPLAN

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

J A

C O

B S

D

U L L E

S C

O R

N E

R P

A R

K S

U

IT

E

R N

D O

N V

A

U T

A H

T E

S T

A N

D T

R A

IN

IN

G R

A N

G E

U

T T

R

C O

N S

O L

ID

A

T E

D M

IS

S

IO

N

C O

N T

R O

L C

E N

T E

R

C M

C C

H

IL

L

A

IR

F O

R C

E B

A S

E

U T

A H

S

E P

T E

M B

E R

P

W P

P -1

-D

-0

FA104

F L

O O

R P

L A

N

A R

E A

C

J F

O U

L K

R S

A L L

W A

S S

E R

M R

A H

M A

N

W C

L A

Y

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

F

IR

E A

L A

R M

JASON FOULK

FIRE PROTECTION ENGINEER

LICENSE NO.: ########

8'4' 16'0

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL NOTESGENERAL NOTES

1 INSTALL NOTIFICATION DEVICES WITHIN SPACE IN

ACCORDANCE WITH UFC 4-133-01, 4-2.6.1.

2 PROVIDE VERY EARLY WARNING SMOKE DETECTION (VEWSD)

FOR IT AREA IN ACCORDANCE WITH NFPA 75.

3 ADDRESSABLE CONTROL MODULE FOR SHUTDOWN OF CRAC

UNIT UPON VEWSD LEVEL 3 ALARM.

4 PROVIDE SEPARATE MONITOR MODULES AS NECESSARY FOR

MONITORING OF EACH ALARM, TROUBLE, AND SUPERVISORY

FUNCTION OF THE VEWSD SYSTEM.

5 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH

CONTROL VALVE TAMPER SWITCH TO FIRE ALARM SYSTEM

FOR SUPERVISORY FUNCTION. VERIFY LOCATION WITH

SPRINKLER CONTRACTOR.

6 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR

INTERFACE WITH SMOKE DAMPER DUCT SMOKE DETECTOR.

MOUNT DEVICE IN ACCORDANCE WITH MANUFACTURER'S

REQUIREMENTS, NFPA 72, AND NFPA 90A. CONNECTIONS TO

FIRE ALARM SYSTEM SHALL BE PROVIDED BY DIVISION 28.

CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY

DIVISION 23.

7 PROVIDE FIRE ALARM SYSTEM IN ACCORDANCE WITH UFC

4-133-01, 3-6.7.3.

8 PROVIDE LOCAL AUDIBLE ALARM. LOCAL ALARM TO BE

INITIATED UPON VEWSD SYSTEM LEVEL 1 AND 2 ACTIVATION.

9 ADDRESSABLE CONTROL MODULE FOR ELECTRONIC

EQUIPMENT POWER SHUTDOWN FUNCTION UPON ZERO

DELAY FLOW SWITCH ACTIVATION.

KEYED NOTES #

1/8" = 1'-0"A1

FLOOR PLAN - FIRE ALARM AREA C

1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT

ACTUAL BUILDING CIRCUITING. REFER TO CONTRACTOR'S

DESIGN DRAWINGS FOR ACTUAL DEVICE LOCATION.

3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED

LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED

POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.

4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.

FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE

WITH APPLICABLE CODES, MANUFACTURER'S

RECOMMENDATIONS, AND EQUIPMENT LISTINGS.

5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND

HVAC SYSTEMS.

6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT

SPECIFICATIONS AND NFPA 72.

7. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO

TEMPORARILY DEACTIVATE THE FIRE ALARM AUDIO AND

VISUAL NOTIFICATION APPLIANCES WHILE DELIVERING

VOICE MESSAGES.

8. REFER TO A1/FA501 FOR MOUNTING HEIGHTS OF ALL

INTERIOR FA/MNS WALL MOUNTED DEVICES AND

COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL

DRAWINGS.

9. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND

COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL

DRAWINGS.

10. FIRE ALARM SYSTEM SHALL BE GROUNDED IN

ACCORDANCE WITH ALL APPLICABLE CODES AND

L E

D

R R

R R

W P

VD

VD

MM

M

M

MM

CM

MM CM

CM

CM

CM

CM CM

FF

CM

A

C

6 8 9 107

B

AOC OPS

LINK 16

HRC

AOC COMM

AOC BENCH /

STORAGE

CORRIDOR

C105

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C

KEYPLAN

B

ID

O P

T

IO

N

UNCLASSIFIED / FOR OFFICIAL USE ONLY

UNCLASSIFIED / FOR OFFICIAL USE ONLY

CORRECTED FINAL (100%) DESIGN SUBMITTAL

S A

C R

A M

E N

T O

D

IS

T R

IC

T

J

S T

R E

E T

S A

C R

A M

E N

T O

C

A

J A

C O

B S

D

U L L E

S C

O R

N E

R P

A R

K S

U

IT

E

R N

D O

N V

A

U T

A H

T E

S T

A N

D T

R A

IN

IN

G R

A N

G E

U

T T

R

C O

N S

O L

ID

A

T E

D M

IS

S

IO

N

C O

N T

R O

L C

E N

T E

R

C M

C C

H

IL

L

A

IR

F O

R C

E B

A S

E

U T

A H

S

E P

T E

M B

E R

P

W P

P -1

-D

-0

FA104A

F L

O O

R P

L A

N

A R

E A

C

B

ID

O P

T

IO

N

J F

O U

L K

R S

A L L

W A

S S

E R

M R

A H

M A

N

W C

L A

Y

F

IR

S T

T

IT

L E

S E

C O

N D

T

IT

L E

F

IR

E A

L A

R M

JASON FOULK

FIRE PROTECTION ENGINEER

LICENSE NO.: ########

1/8" = 1'-0"A1

FLOOR PLAN - FIRE ALARM AREA C - BID OPTION 3

8'4' 16'0

SCALE: 1/8"=1'-0"

PLAN NORTH

GENERAL NOTESGENERAL NOTES

1 INSTALL NOTIFICATION DEVICES WITHIN SPACE IN

ACCORDANCE WITH UFC 4-133-01, 4-2.6.1.

2 PROVIDE VERY EARLY WARNING SMOKE DETECTION (VEWSD)

FOR IT AREA IN ACCORDANCE WITH NFPA 75.

3 ADDRESSABLE CONTROL MODULE FOR SHUTDOWN OF CRAC

UNIT UPON VEWSD LEVEL 3 ALARM.

4 PROVIDE SEPARATE MONITOR MODULES AS NECESSARY FOR

MONITORING OF EACH ALARM, TROUBLE, AND SUPERVISORY

FUNCTION OF THE VEWSD SYSTEM.

5 ADDRESSABLE MONITOR MODULE FOR INTERFACE WITH

CONTROL VALVE TAMPER SWITCH TO FIRE ALARM SYSTEM

FOR SUPERVISORY FUNCTION. VERIFY LOCATION WITH

SPRINKLER CONTRACTOR.

6 ADDRESSABLE CONTROL MODULE AT HVAC EQUIPMENT FOR

INTERFACE WITH SMOKE DAMPER DUCT SMOKE DETECTOR.

MOUNT DEVICE IN ACCORDANCE WITH MANUFACTURER'S

REQUIREMENTS, NFPA 72, AND NFPA 90A. CONNECTIONS TO

FIRE ALARM SYSTEM SHALL BE PROVIDED BY DIVISION 28.

CONNECTIONS TO HVAC EQUIPMENT SHALL BE PROVIDED BY

DIVISION 23.

7 PROVIDE FIRE ALARM SYSTEM IN ACCORDANCE WITH UFC

4-133-01, 3-6.7.3.

8 PROVIDE LOCAL AUDIBLE ALARM. LOCAL ALARM TO BE

INITIATED UPON VEWSD SYSTEM LEVEL 1 AND 2 ACTIVATION.

9 ADDRESSABLE CONTROL MODULE FOR ELECTRONIC

EQUIPMENT POWER SHUTDOWN FUNCTION UPON ZERO

DELAY FLOW SWITCH ACTIVATION.

KEYED NOTES #

1. REFER TO FA001 FOR LEGEND, ABBREVIATIONS AND

GENERAL NOTES.

2. DEVICES SHOWN ARE TYPICAL AND DO NOT REFLECT

ACTUAL BUILDING CIRCUITING. REFER TO CONTRACTOR'S

DESIGN DRAWINGS FOR ACTUAL DEVICE LOCATION.

3. FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED

LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED

POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.

4. THE DEVICES ARE SHOWN IN SUGGESTED LOCATIONS.

FINAL QUANTITY AND LAYOUT SHALL BE IN ACCORDANCE

WITH APPLICABLE CODES, MANUFACTURER'S

RECOMMENDATIONS, AND EQUIPMENT LISTINGS.

5. COORDINATE DEVICE LOCATIONS WITH LIGHTING AND

HVAC SYSTEMS.

6. DESIGN SYSTEM IN ACCORDANCE WITH PROJECT

SPECIFICATIONS AND NFPA 72.

7. MASS NOTIFICATION SYSTEM SHALL HAVE THE ABILITY TO

TEMPORARILY DEACTIVATE THE FIRE ALARM AUDIO AND

VISUAL NOTIFICATION APPLIANCES WHILE DELIVERING

VOICE MESSAGES.

8. REFER TO A1/FA501 FOR MOUNTING HEIGHTS OF ALL

INTERIOR FA/MNS WALL MOUNTED DEVICES AND

COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL

DRAWINGS.

9. MOUNT ALL EXTERIOR FA/MNS DEVICES AT 12' AFG AND

COORDINATE MOUNTING LOCATION WITH ARCHITECTURAL

DRAWINGS.

10. FIRE ALARM SYSTEM SHALL BE GROUNDED IN

ACCORDANCE WITH ALL APPLICABLE CODES AND

STANDARDS.

11. HALFTONE INDICATES DEVICES ARE INCLUDED AS PART

OF BASE BID. OTHER DEVICES ARE IN ADDITION TO OR

RELOCATED FROM BASE BID AS PART OF ABI 3.

LOCAL

OPERATING

CONSOLE

1 0

1 1

1 2

1 4

1 5

1 6

1 7

1 8

1 9

2 0

2 1

2 2

2 3

2 4

OK TO

PAGE

MIC

TBL

ALL

CALL

1 1 3

SYSTEM

CONT ROL

SYSTEM

IN

USE

FIRE SYSTEM

ACTIVE

MANUAL PULL STATION ACTIVATION

FIRE ALARM SYSTEM TROUBLE

FIRE ALARM SYSTEM PRIMARY POWER LOSS

OPERATION OF MASS NOTIFICATION SYSTEM

ACTIVATION OF GENERAL CARBON MONOXIDE DETECTOR

VEWSD LEVEL 1 ACTIVATION

VEWSD LEVEL 2 ACTIVATION

VEWSD LEVEL 3 ACTIVATION

NOTIFICATION

SYSTEM OUTPUTSACTIONS

SYSTEM INPUTS A

F A

M N

P A

LA

R

M L

E D

A N

D A

U D

IB

LE

S

IG

N A

L

F A

M N

P S

U P

E R

V

IS

O R

Y L

E D

A N

D A

U D

IB

LE

S

IG

N A

L

F A

M N

P T

R O

U B

LE

L

E D

A N

D A

U D

IB

LE

S

IG

N A

L

A C

T

IV

A T

E M

A S

S N

O T

IF

IC

A T

IO

N

S Y

S T

E M

M E

S S

A G

E

IL

LU

M

IN

A T

E A

S S

O C

IA

T

E D

R E

M O

T E

L E

D

REQUIRED FIRE

SAFETY CONTROL

F A

M N

P M

A S

S N

O T

IF

IC

A T

IO

N

A

LA

R M

L E

D A

N D

A U

D

IB

LE

S

IG

N

A L

S H

U T

D O

W N

A S

S O

C

IA

T E

D H

V A

C U

N

IT

O N

LY

CONTROL UNIT

ANNUNCIATION

F A

M N

P L

C D

M E

S S

A G

E

D E

A C

T

IV

A T

E F

IR

E

A

LA

R M

A U

D

IB

LE

S

IG

N

A L

A N

D P

A F

U N

C T

IO

N

T R

A N

S M

IT

T

R O

U B

LE

S

IG

N

A L

T O

C E

N T

R A

L S

T A

T

IO

N /F

IR

E

D E

P T

T R

A N

S M

IT

S

U P

E R

V

IS

O R

Y S

IG

N

A L

T O

C E

N T

R A

L S

T A

T

IO

N /F

IR

E

D E

P T

T R

A N

S M

IT

F

IR

E

A

LA

R M

S

IG

N A

L T

O C

E N

T R

A L

S T

A T

IO

N

/F

IR

E D

E P

T

A C

T

IV

A T

E F

IR

E

A

LA

R M

E V

A C

U A

T

IO

N A

U D

IB

LE

/V

IS

U A

L A

LA

R

M S

A C

T

IV

A T

E N

O T

IF

IC

A T

IO

N

/T R

A N

S M

IT

C

O S

IG

N

A L

T O

C E

N T

R A

L S

T A

T

IO

N

A C

T

IV

A T

E E

X T

E R

IO

R

E

LE

C T

R

IC

B E

LL

S E

N D

S

IG

N A

L T

O S

H U

T D

O W

N P

O W

E R

T O

C E

R /S

E R

V E

R R

O O

M

INDICATES ACTION WILL CAUSE SPECIFIC RESULTS INDICATES ACTION WILL NOT CAUSE SPECIFIC RESULTS

FIRE ALARM AND MASS NOTIFICATION MATRIX

S E

N D

S

IG

N A

L T

O E

N E

R G

IZ

E

E G

R E

S S

L

IG

H T

IN

G

C O

N T

R O

LL

E

D B

Y O

C C

U P

A N

T S

E N

S O

R S

1 1

B C D E F G H I J K L N O P

AREA SMOKE DETECTOR ACTIVATION2

SPRINKLER WATERFLOW SWITCH ACTIVATION3

SPRINKLER CONTROL VALVE

TAMPER SWITCH ACTIVATION

DUCT SMOKE DETECTOR ACTIVATION5

SYSTEM INPUTS A B C D E F G H I J K L M N O P Q R S T U V W X

Y

D O

O R

H O

LD

R

E

LE

A S

E

Z

OPERATION OF WIDE AREA MASS NOTIFICATION SYSTEM

S M

O K

E D

A M

P E

R A

C T

U A

T

IO

N

Q R S T

FIRE ALARM AC POWER FAILURE

A C

T

IV

A T

E U

N

IQ

U E

C O

D E

T E

C T

IO

N

V O

IC

E

N O

T

IF

IC

A

T

IO

N M

E S

S A

G E

M U

A C

T

IV

A T

E L

O C

A L

A U

D

IB

LE

A

LA

R

M

VEWSD LEVEL 1 ACTIVATION (AOC COMM…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .