This document is a detailed requirements description for specific cables needed by the U.S. Army Aberdeen Test Center (ATC) for data acquisition purposes. The requirements specify four distinct cable types with precise manufacturer specifications: 1) Omega temperature cable (50,000 feet/year, yellow polyvinyl jacket, 4 pair, 20AWG, 1000 feet per spool), 2) Belden computer cable (150,000 feet/year, grey PVC jacket, 4 pair twisted, 24 AWG stranded, 1000 feet per spool), 3) Belden audio control cable (10,000 feet/year, grey PVC jacket, 3 pair twisted, 20 AWG stranded, 500 feet per spool), and 4) Belden 50ohm Triax Cable (20,000 feet/year, yellow PVC jacket, analog video cable, 500 feet per spool). No substitutions are permitted due to specific frequency response and electrical specifications requirements. Delivery is expected within 90 days after order receipt to the U.S. Army Aberdeen Test Center at Aberdeen Proving Ground, MD 21005-5059.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATC Cables Requirements 30 March 2025
1. Background
The U.S. Army Aberdeen Test Center (ATC) frequently uses these four cables for data acquisition purposes. To support these efforts, ATC is looking to precure (4) different types of cable.
2. Cable List
The following are the specific cable models and brand names that must be supplied. No substitutions are acceptable.
* Omega temperature cable: 50,000 feet per year
-Multipair extension cable
-Manufacturer part # 4KX20PPSH
-Yellow polyvinyl jacket, 4 pair cable 20AWG
-1000 feet per spool
* Belden computer cable: 150,000 feet per year
-Computer EIA RS-232/422 Cable
-Manufacturer part # 8104 0601000
-Grey PVC jacket, 4 pair twisted cable, 24 AWG stranded
-1000 feet per spool
* Belden audio control cable: 10,000 feet per year
-Multipair extension cable
-Manufacturer part # 9873 060
-Grey PVC jacket, 3 pair twisted cable, 20 AWG stranded
-500 feet per spool
* Belden 50ohm Triax Cable: 20,000 feet per year
-Analog video cable
-50 Ohm Triax RG-58A/U Type, 20 AWG stranded
-Manufacturer part # 9222 004500
-Yellow PVC jacket
-500 feet per spool
3. Delivery Address
U.S. Army Aberdeen Test Center
Aberdeen Proving Ground MD 21005-5059
4. Expected Delivery Date
Within 90 days after receipt of order