Approved for construction Marshall_20261009.pdf
PDF 11 MB Posted
- Attached to
- Marshall Rd IRA - Bathroom Renovation
- Solicitation number
- 2140346
- Issued by
- St. Lawrence County, New York
About this file
Summary
This file comprises construction drawings and technical specifications for a bathroom renovation project at the Marshall Road Individualized Residential Alternative (IRA) facility located at 1519 Marshall Road, Waterloo, New York 13165, operated by the New York State Office for People with Developmental Disabilities (OPWDD), Finger Lakes Developmental Disabilities Service Office (DDSO). The project involves comprehensive bathroom renovations classified as a Level 2 Alteration under the 2025 New York State Building Code, including demolition of existing fixtures and finishes, replacement of bathroom fixtures (toilet, vanity sink, shower assembly with trench drain), installation of new wall and ceiling materials with waterproofing and tiling, electrical and plumbing system upgrades, installation of grab bars and accessibility features compliant with ADA standards, and related mechanical systems work. The 90 percent permit set documents include detailed demolition and construction plans with specifications for materials, finishes, and installation methods. A mandatory site visit is required on Thursday, November 19, 2026, at 10:00 AM for all prospective bidders; attendance for the entire duration is mandatory, and late arrival or non-attendance will result in bid disqualification. Bids will not be accepted from vendors who do not attend the site visit.
This is a New York State public works project requiring payment of prevailing wages. Bidders must provide a valid New York State Department of Labor (NYSDOL) registration number and Certificate of Registration at the time of bid submission; failure to provide these credentials will result in automatic disqualification. The NYSDOL estimates approximately 3-4 weeks for processing registration applications. Interested vendors should request an invitation for bid by referencing the project location and title on company letterhead, including current contact information (email or fax), and submit requests to Franchesca Sagen via fax at 585-461-8811 or via email to FL.Purchasing@opwdd.ny.gov. No advance notification of site visit attendance is required.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SOW.pdf | ||
| CP-FL-H2581-2026109_Bathroom_Renovation_MARSHALL_ROAD.pdf | ||
| FLDDSO - 1519 Marshall Road - 9-18-25.pdf | ||
| RFQ.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIST OF DRAWINGS
T100 TITLE SHEET
G001 GENERAL NOTES
D101 DEMOLITION PLAN
A101 FIRST FLOOR PLAN
A201 DETAILS
BATHROOM RENOVATION
1519 MARSHALL RD
WATERLOO, NY 13165
NEW YORK
STATE OF
OPPORTUNITY
Office for People With Developmental Disabilitis
IRA SITE ADDRESS
MARSHALL RD
FINGER LAKES DDSO
620 WESTFALL RD, ROCHESTER, NY 14620
SCALE: NTS
SITE MAP
SCALE: NTS
LOCATION MAP
SCOPE OF WORKS
BATHROOM RENOVATIONS LOCATED AT BATHROOM A.
N N
HE
C
Pr oj ec t N o.
P
ER
M
IT
S
ET
DA
TE
: 0 9/
/2
M
AR
SH
AL
L
RO
AD
, W
AT
ER
LO
O
, N Y
M
AR
SH
AL
L
RO
AD
IR
A
BA
TH
RO
O
M R
EN
O
VA
TI
O N
O
PW
DD
F
LD
DS
O C
M M
F L2
T100
37-15 73rd St, Room 203 Jackson Heights, NY 11372 wardanj Accepted For Construction
GENERAL NOTES
OCCUPANCY: SINGLE FAMILY RESIDENCE
CONSTRUCTION CLASS: TYPE 5-B
CODE COMPLIANCE: 2025 NYS BUILDING CODE
2025 NYS EXISTING BUILDING CODE
2025 NYS RESIDENTIAL CODE
2025 NYS PLUMBING CODE
NEC 2026 EDITION
14 NYCRR 635-7
OPWDD Design Standards NFPA 101 - Life Safety Code NYS Uniform Code NYS Environmental and Energy Code
CONSTRUCTION TYPE: LEVEL 2 ALTERATION
NFPA LSC: CHAPTER 33 EXISTING BOARD AND
CARE
CODE INFORMATION
1. FL DDSO HAS COMPLETED A LIMITED SURVEY FOR ASBESTOS
AND PCB. COPIES OF THE SURVEY CAN BE OBTAINED FROM
DDSO PROJECT MANAGER.
2. IF SUSPECT MATERIAL, THAT HAVE NOT BEEN TESTED, ARE
ENCOUNTERED, NOTIFY THE FL DDSO PROJECT MANAGER,
WHO WILL ARRANGE FOR ADDITIONAL TESTING AND/OR
PROVIDE DIRECTION. DO NOT DISTURB SUSPECT MATERIALS.
3. CONTRACTOR SHALL PHASE THE SCOPE OF WORK TO
MAINTAIN EXISTING BUILDING EXITS, AS APPROVED BY
FL DDSO FIELD REPRESENTATIVE.
4. THE OWNER WILL REMOVE LOOSE ITEMS AND FURNISHINGS
FROM THE BATHROOM.
5. PROVIDE A DUST ENCLOSURE OF FIRE-RETARDANT
POLYETHYLENE, SEALED WITH TAPE AT THE PERIMETER AND
AT ALL JOINTS. PROVIDE DOUBLE OVERLAPPING
POLYETHYLENE ENTRIES INTO THE DUST ENCLOSURES.
6. DEMOLITION DRAWINGS AND NOTES ARE A GENERAL GUIDE
TO THE EXTENT OF REMOVALS, BUT THEY ARE NOT
COMPREHENSIVE. THE CONTRACTOR SHALL SURVEY THE
WORK PRIOR TO SUBMITTING A PROPOSAL AND DETERMINE
THE FULL EXTENT OF REMOVALS. THE WORK INCLUDES ALL
REMOVALS REQUIRED TO PROPERLY INSTALL THE WORK,
INCLUDING REMOVALS REQUIRED FOR NEW MECHANICAL,
PLUMBING AND ELECTRICAL WORK.
7. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY
PROTECTION FOR THE EXISTING FIRE ALARM AND SPRINKLER
SYSTEM AS REQUIRED DURING DEMOLITION AND
CONSTRUCTION ACTIVITIES. IF THE FIRE ALARM AND/OR
SPRINKLER SYSTEM IS REQUIRED TO BE DISABLED FOR ANY
REASON, THE CONTRACTOR SHALL PROVIDE A WRITTEN
NOTICE TO DDSO FIELD REPRESENTATIVES 72 HOURS PRIOR
TO SHUTDOWN. SHOULD ANY DAMAGE TO THE FIRE ALARM
AND SPRINKLER SYSTEM OCCUR AS A RESULT OF
CONSTRUCTION ACTIVITIES, THE DAMAGE TO THESE
SYSTEMS SHALL BE REPAIRED IMMEDIATELY BY THE
CONTRACTOR AT NO EXPENSE TO THE OWNER.
GENERAL DEMOLITION NOTES:
1. THE CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND
EXISTING CONDITIONS PRIOR TO COMMENCING WORK.
NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES
FROM THESE DOCUMENTS, OF CONDITIONS THAT REQUIRE
DEVIATION FROM THESE DOCUMENTS, AND OF CONDITIONS
THAT REQUIRE WORK ADDITIONAL TO THE WORK IN THESE
DOCUMENTS.
2. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING DAMAGE
TO EXISTING MATERIALS THAT REMAIN WHEN THAT DAMAGE
RESULTS FROM THE EXECUTION OF THE WORK. THE
CONTRACTOR SHALL PROVIDE RECORD PHOTOGRAPHS OF
PRE-EXISTING DAMAGE PRIOR TO COMMENCING WORK.
3. THE BUILDING WILL BE OCCUPIED CONTINUOUSLY. SECURE
AND PROTECT ALL AREAS, INTERIOR AND EXTERIOR, DURING
THE DURATION OF THE WORK. MAINTAIN EXITS AT ALL TIMES.
4. PHASE THE WORK AS REQUIRED FOR THE OWNER TO
CONTINUE OPERATIONS.
5. ALL COLOR SELECTIONS INCLUDING AGGREGATE COLORS TO
BE MADE BY THE OWNER.
6. THE CONTRACTOR SHALL COMPLY WITH OPWDD SAFETY PLAN
AND COORDINATE ALL WORK WITH OPWDD FIELD STAFF.
GENERAL CONSTRUCTION NOTES:
1. ALL WORK SHALL CONFORM TO THE NEC 2026 EDITION.
2. PRIOR TO PERFORMING ANY WORK, A LICENSED ELECTRICIAN
SHALL IDENTIFY ALL CIRCUITS TO THE AREA OF WORK, AND
PROVIDE A REPORT OF THE FINDINGS TO THE DESIGNER OF
RECORD. ALL RECEPTACLE OUTLET AND APPLIANCES SHALL
BE IDENTIFIED BY CIRCUIT NUMBER.
3. ALL CONDUCTORS PROVIDED SHALL BE 3 #12AWG COPPER
MINIMUM.
4. PROVIDE CLEAN UPDATED CIRCUIT DIRECTORIES IN EACH
PANELBOARD AFFECTED BY THE WORK.
5. PROVIDE FIRESTOPPING FOR ALL WALL AND FLOOR
PENETRATIONS TO MAINTAIN EXISTING FIRE RATING
ASSEMBLIES.
6. ALL RECEPTACLE OUTLETS IN THE AREA OF WORK SHALL BE
ARC-FAULT CIRCUIT-INTERRUPTER PROTECTED.
7. ALL RECEPTACLE OUTLETS BEING PROVIDED SHALL BE
TAMPER-RESISTANT TYPE.
8. ALL ELECTRICAL ITEMS PROVIDED BY THE CONTRACT SHALL
BE LISTED FOR THEIR INTENDED PURPOSE.
9. RECEPTACLE OUTLETS MARKED GFI ON THE PLANS SHALL BE
PROTECTED BY EITHER AN INTEGRAL GROUND FAULT CIRCUIT
INTERUPTER OR GROUND FAULT CIRCUIT INTERUPTER AT A
DEVICE AHEAD OF THE RECEPTACLE OUTLET IN THE CIRCUIT
(SUPPLY SIDE).
10. CONFIRM THAT AT A MINIMUM, A DEDICATED 20 AMP BRANCH
CIRCUIT SUPPLIES THE ELECTRICAL DEVICES IN THE
BATHROOM AND THAT NO OTHER OUTLETS ARE SUPPLIED
FROM THIS CIRCUIT AS REQUIRED BY SECTION 210.11(C)(3) OF
THE NEC 2026 EDITION.
GENERAL ELECTRICAL NOTES:
1. PLUMBING WATER PIPING, ASSOCIATED FITTINGS AND
ACCESSORIES SHALL CONFORM WITH NSF/ANSI STANDARD 61.
2. PLUMBING WATER PIPING SHALL BE TYPE L COPPER WITH
WROUGHT COPPER SOLDERED FITTINGS (VERIFY IT MATCHES
EXISTING PIPING MATERIAL). FLUX FOR SOLDERING SHALL BE
WATER SOLUBLE. SOLDERS SHALL BE OATEY 95 /5 TIN
ANTIMONY WIRE SOLDER OR EQUIVALENT.
3. NEW VENT/ SANITARY PIPING SHALL BE SCHEDULE 40 SOLID
CORE PVC WITH PRIMED AND SOLVENT CEMENTED JOINTS AND
FITTINGS, COMPIANT TO ASTM FOR THE APPLICATION. PROVIDE
APPROVED ADAPTOR FITTINGS TO CONNECT EXISTING PIPING.
4. ALL WATER AND DRAIN PIPING SHALL BE SUPPORTED AND
LEAK TESTED IN ACCORDANCE WITH THE NYS RESIDENTIAL
CODE SECTIONS RP2503.1 AND RP2605.1 PRIOR TO THE
ADDITION OF FINAL FINISHES OR CONCEALING MATERIALS.
5. PIPING DEAD ENDS SHALL BE PROHIBITED OR REMOVED.
6. ALL NEW WATER PIPING SHALL BE INSULATED WITH
PRE-FORMED FIBERGLASS INSULATION WITH AN ALL SERVICE
JACKET. MINIMUM R-3 WITH VAPOR BARRIER AT COLD WATER
SUPPLY.
7. DOMESTIC WATER PIPING SHALL BE DISINFECTED PER DOH
RECOMMENDATIONS PRIOR TO NORMAL OPERATION.
8. ALL WATER, SANITARY AND VENT PIPING SHALL BE ADJUSTED
OR EXTENDED AS NECESSARY TO ACCOMMODATE THE NEW
LOCATION OF APPLIANCES AND FIXTURES THAT ARE UNDER
THIS CONTRACT.
9. ANY ALTERATION OF WALLS AND FLOOR DUE TO PLUMBING OR
MECHANICAL WORK SHALL BE FILLED/ PATCHED AS REQUIRED
TO MATCH EXISTING.
10. PROVIDE ACCESSIBLE CLEANOUTS FOR DRAINAGE PIPING AS
REQUIRED BY CODE AND AT EVERY CHANGE OF DIRECTION
HIGHER THAN 45 DEGREE.
11. INSTALL HORIZONTAL DRAINAGE PIPING IN UNIFORM
ALIGNMENT AT UNIFORM SLOPE; NOT LESS THAN 2% FOR
2-1/2” PIPING AND SMALLER AND NOT LESS THAN 1% FOR 3”
PIPING AND BIGGER.
12. DRAINAGE PIPING SHALL NOT BE REDUCED IN SIZE IN THE
DIRECTION OF THE FLOW.
13. VENTS SHALL BE DISCONNECTED FROM SANITARY TO
ACCOMMODATE THE WORK AND RECONNECTED TO NEW
PIPING. ALL FIXTURES SHALL BE VENTED PER CODE.
14. PROVIDE IDENTIFICATION TO DOMESTIC COLD AND HOT
WATER NEW INSULATED PIPING INCLUDING DIRECTION OF
FLOW.
15. PROVIDE SHOWER TESTING IN ACCORDANCE WITH NYSRC
SECTION 2503.6.
GENERAL MECHANICAL AND PLUMBING NOTES:
THESE DOCUMENTS CONTAIN POTENTIALLY SENSITIVE
INFORMATION AND SHAL BE USED FOR THEIR
INTENDED PURPOSE. ONCE THE INTENDED PURPOSE
HAS CEASD, THE DOCUMENTS SHALL BE DSTROYED IN
A SECURE MANNER.
IT IS A VIOLATION OF STATE EDUCATION LAW FOR ANY
PERSON UNLESS UNDER HE DIRECTION OF A LICENSED
ARCHITECT/ENGINEER TO ALTER THIS DOCUMENT IN
ANYWAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH A DESRIPTION OF THE ALTERATINS, DATE
AND ARCHITECT'S/ENGINEER'S SIGNATURE.
COPYRIGHT©2026
Consultants:
HUQ ENGINEERING CONSULTANCY, PLLC
37-15 73rd St, Room 203 Jackson Heights, NY 11372
Phone: 646 283 7675
Submissions/Revisions:
Drawing Title:
Marshall Road IRA - Bathroom Design
Job Number:
Drawing Number:
G001 Sheet Number:
xxxx
Project:
GENERAL NOTES
1519 Marshall Rd, Waterloo, NY 13165
Client:
OFFICE FOR PEOPLE WITH
DEVELOPMENTAL DISABILITIES
620 Westfall Rd, Rochester, NY 14620
FINGER LAKES DDSO
09/14/2026
Project Key:
90% Permit Set
DateDescription
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLAN1
D101
RENOVATION AREA
KITCHEN DINING
LIVING
ROOM ACTIVITY
HALLWAY
BATH A
BEDROOM
H
AL
LW
AY
BEDROOM
BEDROOM
BEDROOM
BEDROOM
HALLWAY
BEDROOM
BEDROOM
STYDY
ROOM
BEDROOM
BEDROOM
BATH C
BATH D
GARAGE PANTRY
BATH
A
1. ALL THE EXISTING FIXTURES "TO BE REPLACED" SHALLL BE
REPLACED WITH NEW ONES AS SHOWN IN THE PROPOSED PLAN.
2. THE UNNECESSARY ELECTRICAL OUTLETS AND SWITCHES SHALL
BE REMOVED ALONG WITH ITS WIRING.
3. THE EXHAUST FAN GRATE WILL BE REPLACED AT ITS LOCATION.
4. THE SUB DRAIN LINES WILL BE REMOVED IF NOT REQUIRED.
5. INTERIOR WALL, FLOOR AND CEILING MATERIALS ARE TO BE
REMOVED DOWN TO THE FRAMING AND REPLACED WITH NEW.
6. REPAIR AND REPLACEMENT OF WALL AND FLOOR FRAMING
SHALL BE MADE IF FOUND DEFECTIVE.
7. THE EXISTING TOILET ALONG WITH THE LIGHT FIXTURE OVER IT
WILL BE REMOVED AND NEW ONES SHALL BE INSTALLED AS
SHOWN IN PROPOSED DRAWINGS.
8. THE GRAB BARS WILL BE REMOVED AND NEW BARS WILL BE
INSTALLED AS PER PROPOSED DRAWINGS.
NOT USED
GENERAL DEMOLITION:
REMOVE EXISTING INTERIOR PERIMETER GWB, WALL FINISH,
CURTAIN ROD AND BRACKETS AND HANDRAILS IN THE BATHROOM
ITS ENTIRETY TO EXISTING WALL FRAMING. PREPARE EXISTING WALL
FRAMING FOR NEW GWB INCLUDING REMOVE ALL NAILS AND SCREWS
AS REQUIRED.
NOT USED3
NOT USED4
NOT USED5
REMOVE EXISTING FLOOR FINISH AND SUB-FLOOR TO EXPOSE
EXISTING FLOOR FRAMING. COORDINATE WITH NEW FLOOR PLAN.
REMOVE EXISTING GWB AT CEILING AS REQUIRED TO EXPOSE
EXISTING FRAMING. PREPARE EXISTING FRAMING TO ACCEPT NEW
GWB INCLUDING REMOVAL OF ANY AND ALL PROTRUDING NAILS, AND
SCREWS. PROVIDE 2X BLOCKING @16" O.C. AT ATTIC RAFTER BAYS
WHERE NEW WALLS LAND BETWEEN EXISTING RAFTERS, TYP.
REMOVE ALL GRAB BARS AND TURN OVER TO OWNER.8
CONTRACTOR TO REMOVE THERAPY TUB AND TURN OVER TO
OPWDD. NOT SHOWN FOR CLARITY, TYP.
NOT USED10
NOT USED11
NOT USED12
KEYED DEMOLITION NOTES
DISCONNECT AND REMOVE SWITCH. PROTECT WIRING AND CIRCUIT
FOR REUSE TO CONNECT DEVICE BEING PROVIDED.
ELECTRICAL DEMOLITION:
E1
DISCONNECT AND REMOVE RECEPTACLE OUTLET. PROTECT WIRING
FOR REUSE.
E2
DISCONNECT AND REMOVE EXISTING LIGHTING FIXTURES. PROTECT
WIRING AND CIRCUIT FOR REUSE TO CONNECT LIGHTING FIXTURE
BEING PROVIDED.
E3
DISCONNECT EXISTING LIGHT/VENT/LIGHT ELECTRICAL
CONNECTIONS AS REQUIRED AND TEMPORARILY DECOMMISSION
CIRCUIT FOR REUSE, TYP.
E4
REMOVE EXISTING VANITY SINK
PLUMBING DEMOLITION:
P1
REMOVE EXISTING TOILET FIXTURE AND DISPOSE.P2
REMOVE SHOWER DRAIN AND ASSOCIATED DRAIN PIPING. RELOCATE
DRAIN PIPING AS REQUIRED FOR NEW SHOWER STALL.
P3
NOT USEDP4
NOT USEDP5
REMOVE WASTE PIPING AS REQUIRED.P6
NOT USED
FIRE ALARM AND SPRINKLER:
F1
PROVIDE PROTECTION AS REQUIRED FOR THE EXISTING FIRE
PROTECTION SYSTEMS IN PLACE.
F3
NOT USEDF4
DEMOLITION NOTES:
CONTRACTOR NOTE:
1. DAMAGE TO EXISTING FIRE DETECTION, ALARM, AND OR
EXISTING SPRINKLER SYSTEM AS A RESULT OF DEMOLITION
OR CONSTRUCTION ACTIVITIES SHALL BE REPAIRED BY THE
CONTRACTOR AT NO COST TO THE OWNER. PROVIDE
PROTECTION TO THESE SYSTEMS AS REQUIRED.
LEGEND
DEMOLITION KEYED NOTE
CONSTRUCTION KEYED WORK
DENOTES REMOVAL
(REFER TO KEYED DEMOLITION NOTES)
DENOTES WALL REMOVAL
DENOTES EXISTING WALL
DENOTES VENT/ LIGHT
DENOTES WALL RECEPTACLE OUTLET
DENOTES FLOOR RECEPTACLE OUTLET
DENOTES LIGHT SWITCH
DENOTES SPRINKLER HEAD
RECEPTACLE OUTLET,
GFI = GROUND FAULT CIRCUIT INTERRUPTER.
AFI = ARC FAULT CIRCUIT INTERRUPTER.
S 20A, 120V LIGHT SWITCH
(TIMER SWITCH)
S
1/2"=1-0"
1ST FL BATHROOM DEMOLITION PLAN2
D101
WH
AIR FRESHNER
(TO BE REPLACED)
THERMOSTAT
(TO BE REMOVED)
SWITCHES
(TO REMAIN)
CABINET (TO
BE REMOVED)
GRAB BAR
(TO BE REMOVED)
GRAB BAR (TO
BE REPLACED)
GRAB BAR
(TO BE REPLACED)
TOILET (TO BE
REPLACED)
SINK-MIRROR-LIGHT
(TO BE RELOCATED
ONE FT TOWARDS SW)
SS
ST
ELECTRIC OUTLET
(TO BE REMOVED)
T
2'x2'
2'x2'
DOOR
(TO REMAIN)
CEILING MOUNTED
HEATERS (TO BE
REMOVED)
CEILING MOUNTED
LIGHT FIXTURE
(TO BE REPLACED)
FIRE STROBE
SW NE
NW
SE
2 6 7 8 E1 E2 E3 P1 P2 P3 P6
GRATE (TO BE REMOVED)
E4
THESE DOCUMENTS CONTAIN POTENTIALLY SENSITIVE
INFORMATION AND SHAL BE USED FOR THEIR
INTENDED PURPOSE. ONCE THE INTENDED PURPOSE
HAS CEASD, THE DOCUMENTS SHALL BE DSTROYED IN
A SECURE MANNER.
IT IS A VIOLATION OF STATE EDUCATION LAW FOR ANY
PERSON UNLESS UNDER HE DIRECTION OF A LICENSED
ARCHITECT/ENGINEER TO ALTER THIS DOCUMENT IN
ANYWAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH A DESRIPTION OF THE ALTERATINS, DATE
AND ARCHITECT'S/ENGINEER'S SIGNATURE.
COPYRIGHT©2026
Consultants:
HUQ ENGINEERING CONSULTANCY, PLLC
37-15 73rd St, Room 203 Jackson Heights, NY 11372
Phone: 646 283 7675
Submissions/Revisions:
Drawing Title:
Marshall Road IRA - Bathroom Design
Job Number:
Drawing Number:
D101 Sheet Number:
xxxx
Project:
DEMOLITION PLANS
AND NOTES
1519 Marshall Rd, Waterloo, NY 13165
Client:
OFFICE FOR PEOPLE WITH
DEVELOPMENTAL DISABILITIES
620 Westfall Rd, Rochester, NY 14620
FINGER LAKES DDSO
09/14/2026
Project Key:
90% Permit Set
DateDescription
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NORTH
1/2"=1-0"
PROPOSED BATHROOM FLOOR PLAN
1/2"=1-0"
NW ELEVATION
1/2"=1-0"
NE ELEVATION
1/2"=1-0"
SE ELEVATION
1/2"=1-0"
SW ELEVATION
WH
13'-8"
(VIF)
'-2
/2
(V
IF
SLOPE 1%
4'-0"
CABINET
3'-0"
1' -0
2'-6"
3'-8"
3' -6
3'
-6
1'-0"
6"
2' -1
0" (T
YP
2'-6"
CABINET
8' -0
(V
IF
VANITY LIGHT
(SEE G-002)
TRENCH DRAIN
WITH GRATE (8')
(SEE SPEC)
TRENCH DRAIN
FLOOR DRAIN
6"
2' -1
0"
2' -1
0"
2' -1
0"
3' -3
/2
SS
SS SS
SS
SS
SS
TS
PS
PS
PS
DOOR TO REMAIN
SOLID
BLOCKING
FOR GB
(TYP)
1' -9
2'-11"
3' -4
SEE G-002
FLOOR DRAIN
DOOR TO REMAIN
3' -6
TY
P)
WAINSCOT
OUTSIDE OF
SHOWER AREA,
SEE (14/A201)
(TYP)
TRENCH DRAIN
SW
SW NE
NW
SE
1%
6"
SINK
(ADA)
3' -6
2'
-0
1/2"=1-0"
REFLECTED CEILING PLAN
CO
EXHAUST
FAN
SS
WH
MIRROR
VANITY LIGHT
PS GFI
N
G48
G48
G30
G36
G42
A101
A101
A101
A101
A101
A101
A101
A101
A101
A101
5'-8"
3' -6
TY
P)
TRANSITION
SEE (14/A201)
A
B
FIRE STROBE
(LIGHTING)
2' -8
2'
-8
3'-0" 3'-0"3'-10" 3'-10"
2' -1
0"
G30
LIGHT (E2)
· 2 LAYERS 5/8" MOISTURE, MOLD AND FIRE RESISTANT GYPSUM
BOARD FROM UGS OR EQUIVALENT.
· TAPED, SPACKLED, SANDED, & PAINTED.
GENERAL CONSTRUCTION:
CEILING ASSEMBLY :
· INSTALL 1/2" USG DUROCK ULTRA LIGHT FOAM TILE BACKER
BOARD (OR EQUIVALENT).
· INSTALL 6 MIL POLYETHYLENE VAPOR RETARDER. TAPE SEAMS.
· USE SILICONE ADHESIVE, TYP. PER SOLID SURFACE
MANUFACTURER INSTALLATION INSTRUCTIONS.
· INSTALL 1/4" SOLID SURFACE PANELS PER MANUFACTURER'S
INSTALLATION GUIDE. MEASURE & CUT PANELS TO BETTER
FINISH AND TO MINIMIZE PANEL WASTE. MOUNT LONG DIMENSION
VERTICAL. COLOR AS SELECTED BY DDSO.)
2 WALL ASSEMBLY (AT SHOWER):
· 6 MIL POLYETHYLENE VAPOR RETARDER. TAPE SEAMS.
· 1/2" BACKER BOARD UP TO 42" AFF.
· 1/4" SOLID SURFACE PANELS AND GROUT TO 42" AFF.
· COLOR PER OPWDD SELECTION.
2a WALL ASSEMBLY: (OUTSIDE SHOWER UP TO 42" AFF)
· INSTALL 1/2" TYPE MOISTURE RESISTANT GYPSUM BOARD TAPED,
SPACKLED, SANDED & WIPED FREE OF DUST AND PAINTED
(COLOR AS PER DDSO SELECTION) SEE PAINT NOTE BELOW.
2b WALL ASSEMBLY: (OUTSIDE SHOWER ABOVE 42")
PROVIDE 2x6 BLOCKING AS REQUIRED FOR NEW GRAB BARS. SEE
DETAILS AT (10/A201).
2c
· EXISTING FLOOR JOISTS.
· PROVIDE 2X WOOD BLOCKING TO STIFFEN FLOOR JOISTS AT
SHOWER TO FLOOR TRANSITION.
· 1 LAYER 3/4" CDX PLYWOOD GLUED AND SCREWED TO FLOOR
FRAMING.
· 1 LAYER 1/2" USG DUROCK ULTRA LIGHT FOAM BACKER BOARD
· 6 MIL ELASTICOAT EPOXY WATERPROOFING MEMBRANE WITH
FIBERGLASS TAPE EMBEDDED WITH NO SAG #1 THICKENER ON
PLYWOOD SEAMS.
· PROVIDE FIREBLOCKING AT PIPE PENETRATIONS.
· PROVIDE EPOXY MORTAR, MAX PITCH 1%. OR APPROVED
EQUIVALENT.
· INSTALL DATILE STEPWISE, CALGARY CG40 LEGACY STRAIGHT
JOINT 2X2 STEPWISE MATTE TILE FLOOR FINISH WITH THINSET
AND GROUT.
· USE SILICONE CAULKING AT THE CORNER.
3 FLOOR FINISH ASSEMBLY:
WALLS: SHERWIN WILLIAMS PROMAR 200 ZERO VOC LATEX PRIMER
B28W2600 SHERWIN WILLIAMS PROINDUSTRIAL
PRECATALIZED WATERSHED EPOXY SEMI GLOSS K46 SERIES
(2 COATS)
CEILING: SHERWIN WILLIAMS PROMAR 200 ZERO VOC LATEX PRIMER
B28W2600 SHERWIN WILLIAMS PROINDUSTRIAL
PRECATALIZED WATERSHED EPOXY SEMI GLOSS K46 SERIES
(2 COATS)
COLOR: AS PER OPWDD SELECTION.
PROVIDE THE FOLLOWING PAINT OR EQUIVALENT:
USE THE EXISTING EXHAUST FAN. INSTALL NEW GRATING.M1
MECHANICAL:
PROVIDE DEVICE INDICATED, REUSE EXISTING CIRCUIT. EXTEND AS
REQUIRED WITH 12/2 W/G TYPE NM.
E1
ELECTRICAL:
PROVIDE DAMP/WET LOCATION FIXTURE: NDR RAZOR R CCT 6” WHITE LOW
PROFILE REGRESSED LED DOWNLIGHT, 90 MIN FIRE RATED OR APPROVED
EQUAL. EXTEND WIRING AS REQUIRED, TYP.
E2
PROVIDE VANITY LIGHT: PROGRESS LIGHTING P2991-15. BRUSHED
NICKEL FINISH, TWO 60W LED EQUIVALENT LAMPS OR APPROVED
EQUAL.
E3
PROVIDE 15A TOGGLE SWITCH WITH WHITE FINISH AND CONNECT TO
CEILING FAN. PROVIDE PHENOLIC PLATE LABEL ABOVE SWITCH THAT
READS "TURN SWITCH OFF WHEN SERVICING FAN".
E4
EXTEND HOT, COLD, SANITARY AND VENT LINES TO NEW SHOWER
CONTROLS AND DRAIN. INSULATE HOT AND COLD WATER PIPING.
PROVIDE SHOWER FIXTURE: DELTA T13H153, DELTA MODEL #
10000-UNWS, VACUUM BREAKER, 30"SLIDE BAR, INTEGRAL CHECK
STOPS. MIXING VALVE MAX HEIGHT: 48" AFF. SET SHOWER MIX WATER
TEMPERATURE NOT GREATER THAN 120° PER NYSRP2708.4
P1
PLUMBING:
P2 PROVIDE NEW ACCESSIBLE WATER CLOSET: SLOAN WETS
8009.8010-STG PRESSURE ASSISTED ADA COMPLIANT TOILET OR
APPROVED EQUIVALENT. PROVIDE ADA COMPLIANT OPEN FRONT
SEAT WITH COVER. EXTEND SANITARY, SUPPLY AND VENT LINES AS
REQUIRED. RELOCATE COLD WATER SUPPLY FROM THE FLOOR TO
THE WALL A MINIMUM OF 9" ABOVE THE FINISHED FLOOR AND
BENEATH THE TANK. INSULATE COLD WATER PIPING IN WALL.
P3 PROVIDE FLOOR DRAIN: SIOUX CHIEF SERIES 822 OR EQUIVALENT.
ADJUSTABLE HEAD,CHROME PLATED NICKEL STRAINER,
PVC BODY AND DRAIN PIPING. CONNECT TO EXISTING BATHROOM
SANITARY PIPING IN SUCH A MANNER AS TO MEET THE VENTING
REQUIREMENTS OF THE CODE.
P4
PROVIDE KOHLER K2035-4-0 WALL MOUNTED SINK AND MOUNTING
HARDWARE OR EQUIVALENT.
P6 PROVIDE NEW PVC SANITARY AND FLOOR DRAIN PIPING TO MAIN
SANITARY LINE AS REQUIRED FOR BATHROOM RENOVATION.
(REFER TO MECHANICAL AND PLUMBING GENERAL NOTES).
LEGEND
CONSTRUCTION KEYED WORK
SS SOLID SURFACE
TS TILED SURFACE
PS PAINTED SURFACE
PT PAPER TOWEL
TD TRENCH DRAIN
GB GRAB BAR
SF SHOWER FAUCET
DENOTES FLOOR PITCH TO DRAIN
RECEPTACLE OUTLET,
GFI = GROUND FAULT CIRCUIT INTERRUPTER.
AFI = ARC FAULT CIRCUIT INTERRUPTER.
S 20A, 120V LIGHT SWITCH
(TIMER SWITCH)
EXHAUST FAN
MIRROR: BOBRICK B290 1830
18"x30" 14" GLASS MIRROR WITH 15 YEAR
WARRANTY ON SILVERING; 304 STAINLESS STEEL
WELDED CHANNEL FRAME WITH SATIN FINISH,
GALVANIZED STEEL BACK
A
TOILET ROOM ACCESSORY SCHEDULE
PROVIDE MANUFACTURER & MODEL LISTED, OR
APPROVED EQUIVALENT.
B TOILET TISSUE DISPENSER: BOBRICK B-667
SINGLE ROLL RECESSED DISPENSER,
304 STAINLESS STEEL SATIN FINISH,
WITH CHROME PLATED PLASTIC SPINDLE
C INSTALL HAMPTON 30 IN. W X 12 IN. D X 42 IN. H
ASSEMBLED WALL KITCHEN CABINET IN SATIN
WHITE, OR EQUIVALENT, AS SHOWN IN THE
DRAWING.
D NOT USED
E NOT USED
GRAB BARS: 11/2" DIAMETER, 304 STAINLESS STEEL
TUBING, SATIN FINISH, CONCEALED MOUNTING
FLANGE WITH 31/4" DIAMETER COVER.
INSTALL AT MIN. 33" TO MAX. 36" FROM
FINISH FLR. TO TOP OF GRAB BAR UNLESS
OTHERWISE NOTED.
PROVIDE SOLID 2 X12 WOOD BLOCKING FOR
ALL GRAB BARS AND WALL MOUNTED FIXTURES
AS REQUIRED BY MANUFACTURERS, TYP
G18 BOBRICK B-6806X18"
G36 BOBRICK B-6806X36"
G42 BOBRICK B-6806X42"
G24 BOBRICK B-6803X24"
> ALL FIXTURES SHALL BE NEW.
> ALL PLUMBING FIXTURES SHALL BE ADA COMPLIANT.
> ALL FIXTURES SHALL BE INSTALLED AS PER ICC A117.1.2009
KEYED NOTES:
BLOCKING NOTE:
PROVIDE 2X BLOCKING AT 12" O.C. BETWEEN
EXISTING FLOOR JOISTS AT SHOWER TO BATHROOM FLOOR
TRANSITION, TYP.
CONTRACTOR NOTE:
> WHERE NEW WALL FRAMING LANDS OFFSET FROM FLOOR
JOISTS AND CEILING RAFTERS, PROVIDE 2X BRIDGING AT
16" O.C, TYP.
G
G48 BOBRICK B-6806X48"
PROVIDE SHOWER TRENCH DRAIN: NEODRAIN (OR EQUAL) LINEAR
SHOWR DRAIN WITH QUADRATO PATTERN GRATE, PROFESSIONAL
BRUSHED 304 STAINLESS STEEL RECTANGULAR SHOWER FLOOR
DRAIN MANUFACTURER, FLOOR SHOWER DRAIN WITH LEVELING FEET,
HAIR STRAINER. SIZE: AS PER DRAWING.
P5INSTALL UNFACED ROCK WOOL FIBERGLASS SOUND ATTENUATION
BATTS IN BATHROOM WALLS.
INSTALL ADDITIONAL BATT INSULATION AT ROOF RAFTERS.4a
INSTALL NEW BATT INSULATION AT EXPOSED EXTERIOR WALL.4c
INSTALL BATT INSULATION AT FLOOR JOISTS4b
F NOT USED
THESE DOCUMENTS CONTAIN POTENTIALLY SENSITIVE
INFORMATION AND SHAL BE USED FOR THEIR
INTENDED PURPOSE. ONCE THE INTENDED PURPOSE
HAS CEASD, THE DOCUMENTS SHALL BE DSTROYED IN
A SECURE MANNER.
IT IS A VIOLATION OF STATE EDUCATION LAW FOR ANY
PERSON UNLESS UNDER HE DIRECTION OF A LICENSED
ARCHITECT/ENGINEER TO ALTER THIS DOCUMENT IN
ANYWAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH A DESRIPTION OF THE ALTERATINS, DATE
AND ARCHITECT'S/ENGINEER'S SIGNATURE.
COPYRIGHT©2026
Consultants:
HUQ ENGINEERING CONSULTANCY, PLLC
37-15 73rd St, Room 203 Jackson Heights, NY 11372
Phone: 646 283 7675
Drawing Title:
Job Number:
Drawing Number:
A101 Sheet Number:
xxxx
Project:
PROPOSED 1ST FLOOR
BATHROOM PLANS
Client:
OFFICE FOR PEOPLE WITH
DEVELOPMENTAL DISABILITIES
620 Westfall Rd, Rochester, NY 14620
FINGER LAKES DDSO
Project Key:
DateDescription Submissions/Revisions:
Marshall Road IRA - Bathroom Design 1519 Marshall Rd, Waterloo, NY 13165
09/14/202690% Permit Set
SCALE: NOT TO SCALE
KEY PLAN1
A201
WH
CABINET
1'-7"
T
N
13A201
STANDING
BATH AREA
A201
A201
A201
A201
A201
14A201
SCALE: NOT TO SCALE
BLOCKING DETAIL10
A201
PROVIDE NEW
UNFACEDSOUND
BATTS AS INDICATED
ON PLAN, TYP.
PROVIDE INSULATION
AT BACK SIDE OF
BLOCKING AT
EXTERIOR WALL, TYP.
PROVIDE AND INSTALL
2x6 BLOCKING
BETWEEN EXISTING
WALL STUD FRAMING.
FASTENER AS
RECOMMENDED BY
MANUFACTURER
6"EPOXY MORTAR
(TOP LAYER) BACKER BOARD
1ST LAYER OF CDX PLYWOOD - GLUED
& SCREWED TO FLOOR JOISTS
(2) 2x6 WOOD BLOCKING AT
PERIMETER OF NEW PLYWOOD
AND FLOOR OR SHOWER DRAIN, TYP.
PROVIDE 12" SQUARE 1
2" MARINE
GRADE PLYWOOD SHIM, GLUED AND
SCREWED TO BASE PLYWOOD, TYP,
DRAIN BODY, TYP.
TILED FLOOR FINISH.
TERMINATE AT DRAIN W/KEYED EDGE
PROVIDE FLOOR/SHOWER DRAIN:
SIOUX CHIEF SERIES 822 2" DRAIN
WITH ROUND STAINLESS STEEL
VANDAL RESISTANT STRAINER OR
APPROVED EQUIVALENT. PROVIDE
DRAIN BODY EXTENSION AS
REQUIRED TO ACCOMMODATE
FLOOR PITCH, TYP. CONTRACTOR
TO PREPARE STAINLESS STEEL
DRAIN BODY FLANGE AS
REQUIRED FOR MORTAR AND
EPOXY COAT.
SCALE: NOT TO SCALE
FLOOR DRAIN DETAIL11
A201
CONTRACTOR NOTE:
DOOR FRAME, BEYOND
NEW THRESHOLD
EXISTING FLOOR AT HALL
WAY
PROVIDE 2X BLOCKING UNDER
MARBLE DOOR THRESHOLD
EXISTING FLOOR
JOISTS (BATHROOM)
EXISTING PLYWOOD
SUB-FLOOR TO REMAIN
REMOVE PLYWOOD SUB-FLOOR TO
EXPOSE EXISTING FRAMING. REMOVE
ALL NAILS, SCREWS & ADHESIVES
FROM FRAMING.
PITCH 1%
PLYWOOD.
BACKER BOARD
EPOXY MORTAR
PORCELAIN FLOOR TILES
SCALE: NOT TO SCALE
THRESHOLD DETAIL12
A201
EXISTING CEILING
FRAMING TO REMAIN, TYP.
CONTRACTOR NOTE:
2x FURRING @ SHOWER
MIXING VALVE WALL
1/2" GYPSUM BOARD
VAPOR RETARDER, TYP.
OUTSIDE SURFACE FINISH
TO REMAN
ROCKWOOL (OR EQ.)
UNFACED SOUND BATTS AS
INDICATED ON PLAN, TYP.
EXISTING WALL FRAMING TO
REMAIN, TYP.
VAPOR RETARDER AT
BATHROOM INTERIORS, TYP.
1/2" GYPSUM BOARD TYPE MR
AT BATHROOM CEILINGS, TYP.
3/8" SOLID SURFACE PANEL, TYP.
-INSTALL PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
1/2" USG DUROCK ULTRA LIGHT
FOAM BACKER BOARD (OR
EQUIVALENT), TYP.
SILICONE ADHESIVE, TYP. PER
SOLID SURFACE MANUFACTURER'S
INSTALLATION INSTRUCTIONS
VAPOR RETARDER
EX'G WOOD BASE MOLDING.
EXISTING FLOOR FRAMING
TO REMAIN - 2 ROWS OF
WOOD BLOCKING TO
STIFFEN FLOOR JOISTS
-UNFACED BATT INSULATION
EX'G 2x WOOD BLOCKING AT
EDGES OF PLYWOOD
EXISTING PLYWOOD
SUB-FLOOR TO REMAIN
REMOVE PLYWOOD SUB-FLOOR TO
EXPOSE EXISTING FRAMING. REMOVE
ALL NAILS, SCREWS & ADHESIVES FROM
FRAMING.
PITCH 1% MAX.
1/2" USG DUROCK ULTRA LIGHT
FOAM BACKER BOARD
6 MIL MOISTURE BARRIER MEMBRANE.
EPOXY MORTAR, MAX PITCH 1%.
DALTILE (STEPWISE) PORCELAIN
FLOOR TILES
SHOWER SIDE
SILICONE ADHESIVE, TYP. PER
SOLID SURFACE MANUFACTURER
INSTALLATION INSTRUCTIONS
1/4" SOLID SURFACE PANELS, TYP.
-INSTALL PER MANUFACTURER'S
INSTALLATION GUIDE
SCALE: NOT TO SCALE
WALL DETAIL (IN SHOWER)13
A201
SCALE: NOT TO SCALE
WALL DETAIL (OUTSIDE SHOWER)14
A201
EXISTING PLYWOOD
SUB-FLOOR TO REMAIN
REMOVE PLYWOOD SUB-FLOOR TO EXPOSE
EXISTING FRAMING. REMOVE ALL NAILS,
SCREWS & ADHESIVES FROM FRAMING.
EXISTING FLOOR FRAMING
TO REMAIN
EXISTING FLOOR FINISH,
OUTSIDE, TYP.
EXISTING WALL FRAMING
AND OUTSIDE FINISHES TO
REMAIN, TYP.
VAPOR RETARDER
ROCKWOOL (OR EQ.)
UNFACED SOUND BATTS AS
INDICATED ON PLAN, TYP.
EXISTING CEILING
FRAMING TO REMAIN, TYP.
1/2" GYPSUM BOARD TYPE MR
AT BATHROOM CEILINGS, TYP.
SILICONE SEALANT, TYP.
1/2" MOISTURE RESISTANT
GYPSUM BOARD,TYP.
1/2" TYPE MR GYPSUM BOARD, TYP.
SILICONE ADHESIVE, TYP. PER
SOLID SURFACE MANUFACTURER'S
INSTALLATION INSTRUCTIONS
1/2" USG DUROCK ULTRA LIGHT
FOAM TILE BACKER BOARD
(OR EQUIVALENT), TYP.
3/8" THICK SOLID SURFACE PANELS
INSTALLED PER MANUFACTURERS
INSTALLATION GUIDE. CONSULT DDSO
WITH COLOR SELECTION.
EPOXY MORTAR, MAX PITCH 1%.
3/4" CDX PLYWOOD.
CONTRACTOR TESTING NOTE:CONTRACTOR NOTE:
RP2503.5 DRAIN, WASTE AND VENT SYSTEMS TESTING. ROUGH-IN AND FINISHED
PLUMBING INSTALLATIONS OF DRAIN, WASTE AND VENT SYSTEMS SHALL BE
TESTED INACCORDANCE WITH SECTIONS RP2503.5.1, RP2503.5.2. AND SHALL
CONDUCT THESE TESTS WITH DDSO FIELD REPRESENTATIVE PRESENT.
RP2503.5.1 ROUGH PLUMBING. DWV SYSTEMS SHALL BE TESTED ON COMPLETION
OF THE ROUGH PIPING INSTALLATION BY WATER OR, FOR PIPING SYSTEMS OTHER
THAN PLASTIC, BY AIR, WITHOUT EVIDENCE OF LEAKAGE. EITHER TEST SHALL BE
APPLIED TO THE DRAINAGE SYSTEM IN ITS ENTIRETY OR IN SECTIONS AFTER
ROUGH-IN PIPING HAS BEEN INSTALLED, AS FOLLOWS:
1. WATER TEST. EACH SECTION SHALL BE FILLED WITH WATER TO A POINT NOT
LESS THAN 5 FEET (1524 MM) ABOVE THE HIGHEST FITTING CONNECTION IN
THAT SECTION, OR TO THE HIGHEST POINT IN THE COMPLETED
SYSTEM. WATER SHALL BE HELD IN THE SECTION UNDER TEST FOR A
PERIOD OF 15 MINUTES. THE SYSTEM SHALL PROVE LEAK FREE BY VISUAL
INSPECTION.
2. AIR TEST. THE PORTION UNDER TEST SHALL BE MAINTAINED AT A GAUGE
PRESSURE OF 5 POUNDS PER SQUARE INCH (PSI) (34 KPA) OR 10 INCHES OF
MERCURY COLUMN (34 KPA). THIS PRESSURE SHALL BE HELD WITHOUT
INTRODUCTION OF ADDITIONAL AIR FOR A PERIOD OF 15 MINUTES.
3. RP2503.07 WATER SUPPLY SYSTEM TESTING. UPON COMPLETION
OF THE WATER SUPPLY SYSTEM OR SECTION OF IT, THE SYSTEM OR
PORTION COMPLETED SHALL BE TESTED AND PROVED TIGHT UNDER A
WATER PRESSURE OF NOT LESS THAN THE WORKING PRESSURE OF THE
SYSTEM OR, FOR PIPING SYSTEMS OTHER THAN PLASTIC, BY AN AIR TEST
OF NOT LESS THAN 50 PSI (345 KPA). THIS PRESSURE SHALL BE HELD FOR
NOT LESS THAN 15 MINUTES. THE WATER USED FOR TESTS SHALL BE
OBTAINED FROM A POTABLE WATER SOURCE
1. THE CONTRACTOR SHALL PROVIDE A SHOWER LINER TEST IN ACCORDANCE
WITH NYSRP 2503.6. WHERE SHOWER FLOORS AND RECEPTORS ARE MADE
WATERTIGHT BY THE APPLICATION OF MATERIALS REQUIRED BY SECTION
RP2709.2, THE COMPLETED LINER INSTALLATION SHALL BE TESTED. THE PIPE
FROM THE SHOWER DRAIN SHALL BE PLUGGED WATERTIGHT FOR THE TEST.
THE FLOOR AND RECEPTOR AREA SHALL BE FILLED WITH POTABLE WATER TO
A DEPTH OF NOT LESS THAN 2 INCHES (51 MM) MEASURED AT THE
THRESHOLD. WHERE A THRESHOLD OF NOT LESS THAN 2 INCHES (51 MM) IN
HEIGHT DOES NOT EXIST, A TEMPORARY THRESHOLD SHALL BE
CONSTRUCTED TO RETAIN THE TEST WATER IN THE LINED FLOOR OR
RECEPTOR AREA TO A LEVEL NOT LESS THAN 2 INCHES (51 MM) IN DEPTH
MEASURED AT THE THRESHOLD. THE WATER SHALL BE RETAINED FOR A TEST
PERIOD OF NOT LESS THAN 15 MINUTES AND THERE SHALL NOT BE EVIDENCE
OF LEAKAGE.
2. THE CONTRACTOR SHALL PROVIDE FINISHED PLUMBING TESTS
INACCORDANCE WITH NYSRP 2503.5.2 AFTER THE PLUMBING FIXTURES HAVE
BEEN SET AND THEIR TRAPS FILLED WITH WATER, THEIR CONNECTIONS
SHALL BE TESTED AND PROVED GAS TIGHT OR WATERTIGHT AS FOLLOWS:
3. WATER TIGHTNESS. EACH FIXTURE SHALL BE FILLED AND THEN DRAINED.
TRAPS AND FIXTURE CONNECTIONS SHALL BE PROVEN WATERTIGHT BY
VISUAL INSPECTION.
4. GAS TIGHTNESS. WHERE REQUIRED BY THE LOCAL ADMINISTRATIVE
AUTHORITY, A FINAL TEST FOR GAS TIGHTNESS OF THE DWV SYSTEM SHALL
BE MADE BY THE SMOKE OR PEPPERMINT TEST. ALL TESTING SHALL BE
CONDU
5. ALL TESTING SHALL BE CONDUCTED WITH DDSO FIELD REPRESENTATIVE
PRESENT
6. PROVIDE 2X BLOCKING AS REQUIRED AT ALL HAND RAIL MOUNTING POINTS
PITCH 1% MAX
PER/FT
1. REFER TO MANUFACTURERS
SURFACE PREP GUIDELINES.
2. PROVIDE 2x8 BRIDGING AT 12"
O.C. BETWEEN FLOOR JOISTS AND
SHIM UNDER EXISTING WALL
FRAMING WHERE WALL IS
PARALLEL TO EXISTING FLOOR
FRAMING
3/4" CDX PLYWOOD.
SILICONE ADHESIVE, TYP. PER
SOLID SURFACE MANUFACTURER'S
INSTALLATION INSTRUCTIONS
1/2" USG DUROCK ULTRA LIGHT
FOAM TILE BACKER BOARD
DALTILE (STEPWISE) PORCELAIN
FLOOR TILES
SILICONE ADHESIVE, TYP.
EXISTING FLOOR
JOISTS (HALLWAY)
TILES
GRAB BAR
1/2" PVC BULL NOSE TILE EDGE TRIM
EXISTING FLOOR
SUBSTRATE
NOTE:
ONLY INSIDE SURFACES OF THE BATHROOM WILL BE
DEMOLISHED AND RECONSTRUCTED. THE OUTSIDE
SURFACES WILL REMAIN AS IS.
EX'G 2x WOOD
BLOCKING AT EDGES
OF PLYWOOD
THESE DOCUMENTS CONTAIN POTENTIALLY SENSITIVE
INFORMATION AND SHAL BE USED FOR THEIR
INTENDED PURPOSE. ONCE THE INTENDED PURPOSE
HAS CEASD, THE DOCUMENTS SHALL BE DSTROYED IN
A SECURE MANNER.
IT IS A VIOLATION OF STATE EDUCATION LAW FOR ANY
PERSON UNLESS UNDER HE DIRECTION OF A LICENSED
ARCHITECT/ENGINEER TO ALTER THIS DOCUMENT IN
ANYWAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH A DESRIPTION OF THE ALTERATINS, DATE
AND ARCHITECT'S/ENGINEER'S SIGNATURE.
COPYRIGHT©2026
Consultants:
HUQ ENGINEERING CONSULTANCY, PLLC
37-15 73rd St, Room 203 Jackson Heights, NY 11372
Phone: 646 283 7675
Drawing Title:
Job Number:
Drawing Number:
A201 Sheet Number:
xxxx
Project:
DETAILS
Client:
OFFICE FOR PEOPLE WITH
DEVELOPMENTAL DISABILITIES
620 Westfall Rd, Rochester, NY 14620
FINGER LAKES DDSO
Project Key:
DateDescription Submissions/Revisions:
Marshall Road IRA - Bathroom Design 1519 Marshall Rd, Waterloo, NY 13165
09/14/202690% Permit Set
| T-100.pdf |
| Sheets and Views |
| T-100 |
| G-001 |
| Sheets and Views |
| G-001 |
| D-101 |
| Sheets and Views |
| D-101 |
| A-101 |
| Sheets and Views |
| A-101 |
| A-201 |
| Sheets and Views |
| A-201 |
File details come from the government source that posted it. Updated .