Approved for construction Marshall_20261009.pdf

PDF 11 MB Posted

Attached to
Marshall Rd IRA - Bathroom Renovation
Solicitation number
2140346
Issued by
St. Lawrence County, New York

About this file

Summary

This file comprises construction drawings and technical specifications for a bathroom renovation project at the Marshall Road Individualized Residential Alternative (IRA) facility located at 1519 Marshall Road, Waterloo, New York 13165, operated by the New York State Office for People with Developmental Disabilities (OPWDD), Finger Lakes Developmental Disabilities Service Office (DDSO). The project involves comprehensive bathroom renovations classified as a Level 2 Alteration under the 2025 New York State Building Code, including demolition of existing fixtures and finishes, replacement of bathroom fixtures (toilet, vanity sink, shower assembly with trench drain), installation of new wall and ceiling materials with waterproofing and tiling, electrical and plumbing system upgrades, installation of grab bars and accessibility features compliant with ADA standards, and related mechanical systems work. The 90 percent permit set documents include detailed demolition and construction plans with specifications for materials, finishes, and installation methods. A mandatory site visit is required on Thursday, November 19, 2026, at 10:00 AM for all prospective bidders; attendance for the entire duration is mandatory, and late arrival or non-attendance will result in bid disqualification. Bids will not be accepted from vendors who do not attend the site visit.

This is a New York State public works project requiring payment of prevailing wages. Bidders must provide a valid New York State Department of Labor (NYSDOL) registration number and Certificate of Registration at the time of bid submission; failure to provide these credentials will result in automatic disqualification. The NYSDOL estimates approximately 3-4 weeks for processing registration applications. Interested vendors should request an invitation for bid by referencing the project location and title on company letterhead, including current contact information (email or fax), and submit requests to Franchesca Sagen via fax at 585-461-8811 or via email to FL.Purchasing@opwdd.ny.gov. No advance notification of site visit attendance is required.

View the file

Other files

File Type Posted
SOW.pdf PDF
CP-FL-H2581-2026109_Bathroom_Renovation_MARSHALL_ROAD.pdf PDF
FLDDSO - 1519 Marshall Road - 9-18-25.pdf PDF
RFQ.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LIST OF DRAWINGS

T100 TITLE SHEET

G001 GENERAL NOTES

D101 DEMOLITION PLAN

A101 FIRST FLOOR PLAN

A201 DETAILS

BATHROOM RENOVATION

1519 MARSHALL RD

WATERLOO, NY 13165

NEW YORK

STATE OF

OPPORTUNITY

Office for People With Developmental Disabilitis

IRA SITE ADDRESS

MARSHALL RD

FINGER LAKES DDSO

620 WESTFALL RD, ROCHESTER, NY 14620

SCALE: NTS

SITE MAP

SCALE: NTS

LOCATION MAP

SCOPE OF WORKS

BATHROOM RENOVATIONS LOCATED AT BATHROOM A.

N N

HE

C

Pr oj ec t N o.

P

ER

M

IT

S

ET

DA

TE

: 0 9/

/2

M

AR

SH

AL

L

RO

AD

, W

AT

ER

LO

O

, N Y

M

AR

SH

AL

L

RO

AD

IR

A

BA

TH

RO

O

M R

EN

O

VA

TI

O N

O

PW

DD

F

LD

DS

O C

M M

F L2

T100

37-15 73rd St, Room 203 Jackson Heights, NY 11372 wardanj Accepted For Construction

GENERAL NOTES

OCCUPANCY: SINGLE FAMILY RESIDENCE

CONSTRUCTION CLASS: TYPE 5-B

CODE COMPLIANCE: 2025 NYS BUILDING CODE

2025 NYS EXISTING BUILDING CODE

2025 NYS RESIDENTIAL CODE

2025 NYS PLUMBING CODE

NEC 2026 EDITION

14 NYCRR 635-7

OPWDD Design Standards NFPA 101 - Life Safety Code NYS Uniform Code NYS Environmental and Energy Code

CONSTRUCTION TYPE: LEVEL 2 ALTERATION

NFPA LSC: CHAPTER 33 EXISTING BOARD AND

CARE

CODE INFORMATION

1. FL DDSO HAS COMPLETED A LIMITED SURVEY FOR ASBESTOS

AND PCB. COPIES OF THE SURVEY CAN BE OBTAINED FROM

DDSO PROJECT MANAGER.

2. IF SUSPECT MATERIAL, THAT HAVE NOT BEEN TESTED, ARE

ENCOUNTERED, NOTIFY THE FL DDSO PROJECT MANAGER,

WHO WILL ARRANGE FOR ADDITIONAL TESTING AND/OR

PROVIDE DIRECTION. DO NOT DISTURB SUSPECT MATERIALS.

3. CONTRACTOR SHALL PHASE THE SCOPE OF WORK TO

MAINTAIN EXISTING BUILDING EXITS, AS APPROVED BY

FL DDSO FIELD REPRESENTATIVE.

4. THE OWNER WILL REMOVE LOOSE ITEMS AND FURNISHINGS

FROM THE BATHROOM.

5. PROVIDE A DUST ENCLOSURE OF FIRE-RETARDANT

POLYETHYLENE, SEALED WITH TAPE AT THE PERIMETER AND

AT ALL JOINTS. PROVIDE DOUBLE OVERLAPPING

POLYETHYLENE ENTRIES INTO THE DUST ENCLOSURES.

6. DEMOLITION DRAWINGS AND NOTES ARE A GENERAL GUIDE

TO THE EXTENT OF REMOVALS, BUT THEY ARE NOT

COMPREHENSIVE. THE CONTRACTOR SHALL SURVEY THE

WORK PRIOR TO SUBMITTING A PROPOSAL AND DETERMINE

THE FULL EXTENT OF REMOVALS. THE WORK INCLUDES ALL

REMOVALS REQUIRED TO PROPERLY INSTALL THE WORK,

INCLUDING REMOVALS REQUIRED FOR NEW MECHANICAL,

PLUMBING AND ELECTRICAL WORK.

7. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY

PROTECTION FOR THE EXISTING FIRE ALARM AND SPRINKLER

SYSTEM AS REQUIRED DURING DEMOLITION AND

CONSTRUCTION ACTIVITIES. IF THE FIRE ALARM AND/OR

SPRINKLER SYSTEM IS REQUIRED TO BE DISABLED FOR ANY

REASON, THE CONTRACTOR SHALL PROVIDE A WRITTEN

NOTICE TO DDSO FIELD REPRESENTATIVES 72 HOURS PRIOR

TO SHUTDOWN. SHOULD ANY DAMAGE TO THE FIRE ALARM

AND SPRINKLER SYSTEM OCCUR AS A RESULT OF

CONSTRUCTION ACTIVITIES, THE DAMAGE TO THESE

SYSTEMS SHALL BE REPAIRED IMMEDIATELY BY THE

CONTRACTOR AT NO EXPENSE TO THE OWNER.

GENERAL DEMOLITION NOTES:

1. THE CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND

EXISTING CONDITIONS PRIOR TO COMMENCING WORK.

NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES

FROM THESE DOCUMENTS, OF CONDITIONS THAT REQUIRE

DEVIATION FROM THESE DOCUMENTS, AND OF CONDITIONS

THAT REQUIRE WORK ADDITIONAL TO THE WORK IN THESE

DOCUMENTS.

2. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING DAMAGE

TO EXISTING MATERIALS THAT REMAIN WHEN THAT DAMAGE

RESULTS FROM THE EXECUTION OF THE WORK. THE

CONTRACTOR SHALL PROVIDE RECORD PHOTOGRAPHS OF

PRE-EXISTING DAMAGE PRIOR TO COMMENCING WORK.

3. THE BUILDING WILL BE OCCUPIED CONTINUOUSLY. SECURE

AND PROTECT ALL AREAS, INTERIOR AND EXTERIOR, DURING

THE DURATION OF THE WORK. MAINTAIN EXITS AT ALL TIMES.

4. PHASE THE WORK AS REQUIRED FOR THE OWNER TO

CONTINUE OPERATIONS.

5. ALL COLOR SELECTIONS INCLUDING AGGREGATE COLORS TO

BE MADE BY THE OWNER.

6. THE CONTRACTOR SHALL COMPLY WITH OPWDD SAFETY PLAN

AND COORDINATE ALL WORK WITH OPWDD FIELD STAFF.

GENERAL CONSTRUCTION NOTES:

1. ALL WORK SHALL CONFORM TO THE NEC 2026 EDITION.

2. PRIOR TO PERFORMING ANY WORK, A LICENSED ELECTRICIAN

SHALL IDENTIFY ALL CIRCUITS TO THE AREA OF WORK, AND

PROVIDE A REPORT OF THE FINDINGS TO THE DESIGNER OF

RECORD. ALL RECEPTACLE OUTLET AND APPLIANCES SHALL

BE IDENTIFIED BY CIRCUIT NUMBER.

3. ALL CONDUCTORS PROVIDED SHALL BE 3 #12AWG COPPER

MINIMUM.

4. PROVIDE CLEAN UPDATED CIRCUIT DIRECTORIES IN EACH

PANELBOARD AFFECTED BY THE WORK.

5. PROVIDE FIRESTOPPING FOR ALL WALL AND FLOOR

PENETRATIONS TO MAINTAIN EXISTING FIRE RATING

ASSEMBLIES.

6. ALL RECEPTACLE OUTLETS IN THE AREA OF WORK SHALL BE

ARC-FAULT CIRCUIT-INTERRUPTER PROTECTED.

7. ALL RECEPTACLE OUTLETS BEING PROVIDED SHALL BE

TAMPER-RESISTANT TYPE.

8. ALL ELECTRICAL ITEMS PROVIDED BY THE CONTRACT SHALL

BE LISTED FOR THEIR INTENDED PURPOSE.

9. RECEPTACLE OUTLETS MARKED GFI ON THE PLANS SHALL BE

PROTECTED BY EITHER AN INTEGRAL GROUND FAULT CIRCUIT

INTERUPTER OR GROUND FAULT CIRCUIT INTERUPTER AT A

DEVICE AHEAD OF THE RECEPTACLE OUTLET IN THE CIRCUIT

(SUPPLY SIDE).

10. CONFIRM THAT AT A MINIMUM, A DEDICATED 20 AMP BRANCH

CIRCUIT SUPPLIES THE ELECTRICAL DEVICES IN THE

BATHROOM AND THAT NO OTHER OUTLETS ARE SUPPLIED

FROM THIS CIRCUIT AS REQUIRED BY SECTION 210.11(C)(3) OF

THE NEC 2026 EDITION.

GENERAL ELECTRICAL NOTES:

1. PLUMBING WATER PIPING, ASSOCIATED FITTINGS AND

ACCESSORIES SHALL CONFORM WITH NSF/ANSI STANDARD 61.

2. PLUMBING WATER PIPING SHALL BE TYPE L COPPER WITH

WROUGHT COPPER SOLDERED FITTINGS (VERIFY IT MATCHES

EXISTING PIPING MATERIAL). FLUX FOR SOLDERING SHALL BE

WATER SOLUBLE. SOLDERS SHALL BE OATEY 95 /5 TIN

ANTIMONY WIRE SOLDER OR EQUIVALENT.

3. NEW VENT/ SANITARY PIPING SHALL BE SCHEDULE 40 SOLID

CORE PVC WITH PRIMED AND SOLVENT CEMENTED JOINTS AND

FITTINGS, COMPIANT TO ASTM FOR THE APPLICATION. PROVIDE

APPROVED ADAPTOR FITTINGS TO CONNECT EXISTING PIPING.

4. ALL WATER AND DRAIN PIPING SHALL BE SUPPORTED AND

LEAK TESTED IN ACCORDANCE WITH THE NYS RESIDENTIAL

CODE SECTIONS RP2503.1 AND RP2605.1 PRIOR TO THE

ADDITION OF FINAL FINISHES OR CONCEALING MATERIALS.

5. PIPING DEAD ENDS SHALL BE PROHIBITED OR REMOVED.

6. ALL NEW WATER PIPING SHALL BE INSULATED WITH

PRE-FORMED FIBERGLASS INSULATION WITH AN ALL SERVICE

JACKET. MINIMUM R-3 WITH VAPOR BARRIER AT COLD WATER

SUPPLY.

7. DOMESTIC WATER PIPING SHALL BE DISINFECTED PER DOH

RECOMMENDATIONS PRIOR TO NORMAL OPERATION.

8. ALL WATER, SANITARY AND VENT PIPING SHALL BE ADJUSTED

OR EXTENDED AS NECESSARY TO ACCOMMODATE THE NEW

LOCATION OF APPLIANCES AND FIXTURES THAT ARE UNDER

THIS CONTRACT.

9. ANY ALTERATION OF WALLS AND FLOOR DUE TO PLUMBING OR

MECHANICAL WORK SHALL BE FILLED/ PATCHED AS REQUIRED

TO MATCH EXISTING.

10. PROVIDE ACCESSIBLE CLEANOUTS FOR DRAINAGE PIPING AS

REQUIRED BY CODE AND AT EVERY CHANGE OF DIRECTION

HIGHER THAN 45 DEGREE.

11. INSTALL HORIZONTAL DRAINAGE PIPING IN UNIFORM

ALIGNMENT AT UNIFORM SLOPE; NOT LESS THAN 2% FOR

2-1/2” PIPING AND SMALLER AND NOT LESS THAN 1% FOR 3”

PIPING AND BIGGER.

12. DRAINAGE PIPING SHALL NOT BE REDUCED IN SIZE IN THE

DIRECTION OF THE FLOW.

13. VENTS SHALL BE DISCONNECTED FROM SANITARY TO

ACCOMMODATE THE WORK AND RECONNECTED TO NEW

PIPING. ALL FIXTURES SHALL BE VENTED PER CODE.

14. PROVIDE IDENTIFICATION TO DOMESTIC COLD AND HOT

WATER NEW INSULATED PIPING INCLUDING DIRECTION OF

FLOW.

15. PROVIDE SHOWER TESTING IN ACCORDANCE WITH NYSRC

SECTION 2503.6.

GENERAL MECHANICAL AND PLUMBING NOTES:

THESE DOCUMENTS CONTAIN POTENTIALLY SENSITIVE

INFORMATION AND SHAL BE USED FOR THEIR

INTENDED PURPOSE. ONCE THE INTENDED PURPOSE

HAS CEASD, THE DOCUMENTS SHALL BE DSTROYED IN

A SECURE MANNER.

IT IS A VIOLATION OF STATE EDUCATION LAW FOR ANY

PERSON UNLESS UNDER HE DIRECTION OF A LICENSED

ARCHITECT/ENGINEER TO ALTER THIS DOCUMENT IN

ANYWAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED

ALONG WITH A DESRIPTION OF THE ALTERATINS, DATE

AND ARCHITECT'S/ENGINEER'S SIGNATURE.

COPYRIGHT©2026

Consultants:

HUQ ENGINEERING CONSULTANCY, PLLC

37-15 73rd St, Room 203 Jackson Heights, NY 11372

Phone: 646 283 7675

Submissions/Revisions:

Drawing Title:

Marshall Road IRA - Bathroom Design

Job Number:

Drawing Number:

G001 Sheet Number:

xxxx

Project:

GENERAL NOTES

1519 Marshall Rd, Waterloo, NY 13165

Client:

OFFICE FOR PEOPLE WITH

DEVELOPMENTAL DISABILITIES

620 Westfall Rd, Rochester, NY 14620

FINGER LAKES DDSO

09/14/2026

Project Key:

90% Permit Set

DateDescription

SCALE: 1/8" = 1'-0"

FIRST FLOOR PLAN1

D101

RENOVATION AREA

KITCHEN DINING

LIVING

ROOM ACTIVITY

HALLWAY

BATH A

BEDROOM

H

AL

LW

AY

BEDROOM

BEDROOM

BEDROOM

BEDROOM

HALLWAY

BEDROOM

BEDROOM

STYDY

ROOM

BEDROOM

BEDROOM

BATH C

BATH D

GARAGE PANTRY

BATH

A

1. ALL THE EXISTING FIXTURES "TO BE REPLACED" SHALLL BE

REPLACED WITH NEW ONES AS SHOWN IN THE PROPOSED PLAN.

2. THE UNNECESSARY ELECTRICAL OUTLETS AND SWITCHES SHALL

BE REMOVED ALONG WITH ITS WIRING.

3. THE EXHAUST FAN GRATE WILL BE REPLACED AT ITS LOCATION.

4. THE SUB DRAIN LINES WILL BE REMOVED IF NOT REQUIRED.

5. INTERIOR WALL, FLOOR AND CEILING MATERIALS ARE TO BE

REMOVED DOWN TO THE FRAMING AND REPLACED WITH NEW.

6. REPAIR AND REPLACEMENT OF WALL AND FLOOR FRAMING

SHALL BE MADE IF FOUND DEFECTIVE.

7. THE EXISTING TOILET ALONG WITH THE LIGHT FIXTURE OVER IT

WILL BE REMOVED AND NEW ONES SHALL BE INSTALLED AS

SHOWN IN PROPOSED DRAWINGS.

8. THE GRAB BARS WILL BE REMOVED AND NEW BARS WILL BE

INSTALLED AS PER PROPOSED DRAWINGS.

NOT USED

GENERAL DEMOLITION:

REMOVE EXISTING INTERIOR PERIMETER GWB, WALL FINISH,

CURTAIN ROD AND BRACKETS AND HANDRAILS IN THE BATHROOM

ITS ENTIRETY TO EXISTING WALL FRAMING. PREPARE EXISTING WALL

FRAMING FOR NEW GWB INCLUDING REMOVE ALL NAILS AND SCREWS

AS REQUIRED.

NOT USED3

NOT USED4

NOT USED5

REMOVE EXISTING FLOOR FINISH AND SUB-FLOOR TO EXPOSE

EXISTING FLOOR FRAMING. COORDINATE WITH NEW FLOOR PLAN.

REMOVE EXISTING GWB AT CEILING AS REQUIRED TO EXPOSE

EXISTING FRAMING. PREPARE EXISTING FRAMING TO ACCEPT NEW

GWB INCLUDING REMOVAL OF ANY AND ALL PROTRUDING NAILS, AND

SCREWS. PROVIDE 2X BLOCKING @16" O.C. AT ATTIC RAFTER BAYS

WHERE NEW WALLS LAND BETWEEN EXISTING RAFTERS, TYP.

REMOVE ALL GRAB BARS AND TURN OVER TO OWNER.8

CONTRACTOR TO REMOVE THERAPY TUB AND TURN OVER TO

OPWDD. NOT SHOWN FOR CLARITY, TYP.

NOT USED10

NOT USED11

NOT USED12

KEYED DEMOLITION NOTES

DISCONNECT AND REMOVE SWITCH. PROTECT WIRING AND CIRCUIT

FOR REUSE TO CONNECT DEVICE BEING PROVIDED.

ELECTRICAL DEMOLITION:

E1

DISCONNECT AND REMOVE RECEPTACLE OUTLET. PROTECT WIRING

FOR REUSE.

E2

DISCONNECT AND REMOVE EXISTING LIGHTING FIXTURES. PROTECT

WIRING AND CIRCUIT FOR REUSE TO CONNECT LIGHTING FIXTURE

BEING PROVIDED.

E3

DISCONNECT EXISTING LIGHT/VENT/LIGHT ELECTRICAL

CONNECTIONS AS REQUIRED AND TEMPORARILY DECOMMISSION

CIRCUIT FOR REUSE, TYP.

E4

REMOVE EXISTING VANITY SINK

PLUMBING DEMOLITION:

P1

REMOVE EXISTING TOILET FIXTURE AND DISPOSE.P2

REMOVE SHOWER DRAIN AND ASSOCIATED DRAIN PIPING. RELOCATE

DRAIN PIPING AS REQUIRED FOR NEW SHOWER STALL.

P3

NOT USEDP4

NOT USEDP5

REMOVE WASTE PIPING AS REQUIRED.P6

NOT USED

FIRE ALARM AND SPRINKLER:

F1

PROVIDE PROTECTION AS REQUIRED FOR THE EXISTING FIRE

PROTECTION SYSTEMS IN PLACE.

F3

NOT USEDF4

DEMOLITION NOTES:

CONTRACTOR NOTE:

1. DAMAGE TO EXISTING FIRE DETECTION, ALARM, AND OR

EXISTING SPRINKLER SYSTEM AS A RESULT OF DEMOLITION

OR CONSTRUCTION ACTIVITIES SHALL BE REPAIRED BY THE

CONTRACTOR AT NO COST TO THE OWNER. PROVIDE

PROTECTION TO THESE SYSTEMS AS REQUIRED.

LEGEND

DEMOLITION KEYED NOTE

CONSTRUCTION KEYED WORK

DENOTES REMOVAL

(REFER TO KEYED DEMOLITION NOTES)

DENOTES WALL REMOVAL

DENOTES EXISTING WALL

DENOTES VENT/ LIGHT

DENOTES WALL RECEPTACLE OUTLET

DENOTES FLOOR RECEPTACLE OUTLET

DENOTES LIGHT SWITCH

DENOTES SPRINKLER HEAD

RECEPTACLE OUTLET,

GFI = GROUND FAULT CIRCUIT INTERRUPTER.

AFI = ARC FAULT CIRCUIT INTERRUPTER.

S 20A, 120V LIGHT SWITCH

(TIMER SWITCH)

S

1/2"=1-0"

1ST FL BATHROOM DEMOLITION PLAN2

D101

WH

AIR FRESHNER

(TO BE REPLACED)

THERMOSTAT

(TO BE REMOVED)

SWITCHES

(TO REMAIN)

CABINET (TO

BE REMOVED)

GRAB BAR

(TO BE REMOVED)

GRAB BAR (TO

BE REPLACED)

GRAB BAR

(TO BE REPLACED)

TOILET (TO BE

REPLACED)

SINK-MIRROR-LIGHT

(TO BE RELOCATED

ONE FT TOWARDS SW)

SS

ST

ELECTRIC OUTLET

(TO BE REMOVED)

T

2'x2'

2'x2'

DOOR

(TO REMAIN)

CEILING MOUNTED

HEATERS (TO BE

REMOVED)

CEILING MOUNTED

LIGHT FIXTURE

(TO BE REPLACED)

FIRE STROBE

SW NE

NW

SE

2 6 7 8 E1 E2 E3 P1 P2 P3 P6

GRATE (TO BE REMOVED)

E4

THESE DOCUMENTS CONTAIN POTENTIALLY SENSITIVE

INFORMATION AND SHAL BE USED FOR THEIR

INTENDED PURPOSE. ONCE THE INTENDED PURPOSE

HAS CEASD, THE DOCUMENTS SHALL BE DSTROYED IN

A SECURE MANNER.

IT IS A VIOLATION OF STATE EDUCATION LAW FOR ANY

PERSON UNLESS UNDER HE DIRECTION OF A LICENSED

ARCHITECT/ENGINEER TO ALTER THIS DOCUMENT IN

ANYWAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED

ALONG WITH A DESRIPTION OF THE ALTERATINS, DATE

AND ARCHITECT'S/ENGINEER'S SIGNATURE.

COPYRIGHT©2026

Consultants:

HUQ ENGINEERING CONSULTANCY, PLLC

37-15 73rd St, Room 203 Jackson Heights, NY 11372

Phone: 646 283 7675

Submissions/Revisions:

Drawing Title:

Marshall Road IRA - Bathroom Design

Job Number:

Drawing Number:

D101 Sheet Number:

xxxx

Project:

DEMOLITION PLANS

AND NOTES

1519 Marshall Rd, Waterloo, NY 13165

Client:

OFFICE FOR PEOPLE WITH

DEVELOPMENTAL DISABILITIES

620 Westfall Rd, Rochester, NY 14620

FINGER LAKES DDSO

09/14/2026

Project Key:

90% Permit Set

DateDescription

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

NORTH

1/2"=1-0"

PROPOSED BATHROOM FLOOR PLAN

1/2"=1-0"

NW ELEVATION

1/2"=1-0"

NE ELEVATION

1/2"=1-0"

SE ELEVATION

1/2"=1-0"

SW ELEVATION

WH

13'-8"

(VIF)

'-2

/2

(V

IF

SLOPE 1%

4'-0"

CABINET

3'-0"

1' -0

2'-6"

3'-8"

3' -6

3'

-6

1'-0"

6"

2' -1

0" (T

YP

2'-6"

CABINET

8' -0

(V

IF

VANITY LIGHT

(SEE G-002)

TRENCH DRAIN

WITH GRATE (8')

(SEE SPEC)

TRENCH DRAIN

FLOOR DRAIN

6"

2' -1

0"

2' -1

0"

2' -1

0"

3' -3

/2

SS

SS SS

SS

SS

SS

TS

PS

PS

PS

DOOR TO REMAIN

SOLID

BLOCKING

FOR GB

(TYP)

1' -9

2'-11"

3' -4

SEE G-002

FLOOR DRAIN

DOOR TO REMAIN

3' -6

TY

P)

WAINSCOT

OUTSIDE OF

SHOWER AREA,

SEE (14/A201)

(TYP)

TRENCH DRAIN

SW

SW NE

NW

SE

1%

6"

SINK

(ADA)

3' -6

2'

-0

1/2"=1-0"

REFLECTED CEILING PLAN

CO

EXHAUST

FAN

SS

WH

MIRROR

VANITY LIGHT

PS GFI

N

G48

G48

G30

G36

G42

A101

A101

A101

A101

A101

A101

A101

A101

A101

A101

5'-8"

3' -6

TY

P)

TRANSITION

SEE (14/A201)

A

B

FIRE STROBE

(LIGHTING)

2' -8

2'

-8

3'-0" 3'-0"3'-10" 3'-10"

2' -1

0"

G30

LIGHT (E2)

· 2 LAYERS 5/8" MOISTURE, MOLD AND FIRE RESISTANT GYPSUM

BOARD FROM UGS OR EQUIVALENT.

· TAPED, SPACKLED, SANDED, & PAINTED.

GENERAL CONSTRUCTION:

CEILING ASSEMBLY :

· INSTALL 1/2" USG DUROCK ULTRA LIGHT FOAM TILE BACKER

BOARD (OR EQUIVALENT).

· INSTALL 6 MIL POLYETHYLENE VAPOR RETARDER. TAPE SEAMS.

· USE SILICONE ADHESIVE, TYP. PER SOLID SURFACE

MANUFACTURER INSTALLATION INSTRUCTIONS.

· INSTALL 1/4" SOLID SURFACE PANELS PER MANUFACTURER'S

INSTALLATION GUIDE. MEASURE & CUT PANELS TO BETTER

FINISH AND TO MINIMIZE PANEL WASTE. MOUNT LONG DIMENSION

VERTICAL. COLOR AS SELECTED BY DDSO.)

2 WALL ASSEMBLY (AT SHOWER):

· 6 MIL POLYETHYLENE VAPOR RETARDER. TAPE SEAMS.

· 1/2" BACKER BOARD UP TO 42" AFF.

· 1/4" SOLID SURFACE PANELS AND GROUT TO 42" AFF.

· COLOR PER OPWDD SELECTION.

2a WALL ASSEMBLY: (OUTSIDE SHOWER UP TO 42" AFF)

· INSTALL 1/2" TYPE MOISTURE RESISTANT GYPSUM BOARD TAPED,

SPACKLED, SANDED & WIPED FREE OF DUST AND PAINTED

(COLOR AS PER DDSO SELECTION) SEE PAINT NOTE BELOW.

2b WALL ASSEMBLY: (OUTSIDE SHOWER ABOVE 42")

PROVIDE 2x6 BLOCKING AS REQUIRED FOR NEW GRAB BARS. SEE

DETAILS AT (10/A201).

2c

· EXISTING FLOOR JOISTS.

· PROVIDE 2X WOOD BLOCKING TO STIFFEN FLOOR JOISTS AT

SHOWER TO FLOOR TRANSITION.

· 1 LAYER 3/4" CDX PLYWOOD GLUED AND SCREWED TO FLOOR

FRAMING.

· 1 LAYER 1/2" USG DUROCK ULTRA LIGHT FOAM BACKER BOARD

· 6 MIL ELASTICOAT EPOXY WATERPROOFING MEMBRANE WITH

FIBERGLASS TAPE EMBEDDED WITH NO SAG #1 THICKENER ON

PLYWOOD SEAMS.

· PROVIDE FIREBLOCKING AT PIPE PENETRATIONS.

· PROVIDE EPOXY MORTAR, MAX PITCH 1%. OR APPROVED

EQUIVALENT.

· INSTALL DATILE STEPWISE, CALGARY CG40 LEGACY STRAIGHT

JOINT 2X2 STEPWISE MATTE TILE FLOOR FINISH WITH THINSET

AND GROUT.

· USE SILICONE CAULKING AT THE CORNER.

3 FLOOR FINISH ASSEMBLY:

WALLS: SHERWIN WILLIAMS PROMAR 200 ZERO VOC LATEX PRIMER

B28W2600 SHERWIN WILLIAMS PROINDUSTRIAL

PRECATALIZED WATERSHED EPOXY SEMI GLOSS K46 SERIES

(2 COATS)

CEILING: SHERWIN WILLIAMS PROMAR 200 ZERO VOC LATEX PRIMER

B28W2600 SHERWIN WILLIAMS PROINDUSTRIAL

PRECATALIZED WATERSHED EPOXY SEMI GLOSS K46 SERIES

(2 COATS)

COLOR: AS PER OPWDD SELECTION.

PROVIDE THE FOLLOWING PAINT OR EQUIVALENT:

USE THE EXISTING EXHAUST FAN. INSTALL NEW GRATING.M1

MECHANICAL:

PROVIDE DEVICE INDICATED, REUSE EXISTING CIRCUIT. EXTEND AS

REQUIRED WITH 12/2 W/G TYPE NM.

E1

ELECTRICAL:

PROVIDE DAMP/WET LOCATION FIXTURE: NDR RAZOR R CCT 6” WHITE LOW

PROFILE REGRESSED LED DOWNLIGHT, 90 MIN FIRE RATED OR APPROVED

EQUAL. EXTEND WIRING AS REQUIRED, TYP.

E2

PROVIDE VANITY LIGHT: PROGRESS LIGHTING P2991-15. BRUSHED

NICKEL FINISH, TWO 60W LED EQUIVALENT LAMPS OR APPROVED

EQUAL.

E3

PROVIDE 15A TOGGLE SWITCH WITH WHITE FINISH AND CONNECT TO

CEILING FAN. PROVIDE PHENOLIC PLATE LABEL ABOVE SWITCH THAT

READS "TURN SWITCH OFF WHEN SERVICING FAN".

E4

EXTEND HOT, COLD, SANITARY AND VENT LINES TO NEW SHOWER

CONTROLS AND DRAIN. INSULATE HOT AND COLD WATER PIPING.

PROVIDE SHOWER FIXTURE: DELTA T13H153, DELTA MODEL #

10000-UNWS, VACUUM BREAKER, 30"SLIDE BAR, INTEGRAL CHECK

STOPS. MIXING VALVE MAX HEIGHT: 48" AFF. SET SHOWER MIX WATER

TEMPERATURE NOT GREATER THAN 120° PER NYSRP2708.4

P1

PLUMBING:

P2 PROVIDE NEW ACCESSIBLE WATER CLOSET: SLOAN WETS

8009.8010-STG PRESSURE ASSISTED ADA COMPLIANT TOILET OR

APPROVED EQUIVALENT. PROVIDE ADA COMPLIANT OPEN FRONT

SEAT WITH COVER. EXTEND SANITARY, SUPPLY AND VENT LINES AS

REQUIRED. RELOCATE COLD WATER SUPPLY FROM THE FLOOR TO

THE WALL A MINIMUM OF 9" ABOVE THE FINISHED FLOOR AND

BENEATH THE TANK. INSULATE COLD WATER PIPING IN WALL.

P3 PROVIDE FLOOR DRAIN: SIOUX CHIEF SERIES 822 OR EQUIVALENT.

ADJUSTABLE HEAD,CHROME PLATED NICKEL STRAINER,

PVC BODY AND DRAIN PIPING. CONNECT TO EXISTING BATHROOM

SANITARY PIPING IN SUCH A MANNER AS TO MEET THE VENTING

REQUIREMENTS OF THE CODE.

P4

PROVIDE KOHLER K2035-4-0 WALL MOUNTED SINK AND MOUNTING

HARDWARE OR EQUIVALENT.

P6 PROVIDE NEW PVC SANITARY AND FLOOR DRAIN PIPING TO MAIN

SANITARY LINE AS REQUIRED FOR BATHROOM RENOVATION.

(REFER TO MECHANICAL AND PLUMBING GENERAL NOTES).

LEGEND

CONSTRUCTION KEYED WORK

SS SOLID SURFACE

TS TILED SURFACE

PS PAINTED SURFACE

PT PAPER TOWEL

TD TRENCH DRAIN

GB GRAB BAR

SF SHOWER FAUCET

DENOTES FLOOR PITCH TO DRAIN

RECEPTACLE OUTLET,

GFI = GROUND FAULT CIRCUIT INTERRUPTER.

AFI = ARC FAULT CIRCUIT INTERRUPTER.

S 20A, 120V LIGHT SWITCH

(TIMER SWITCH)

EXHAUST FAN

MIRROR: BOBRICK B290 1830

18"x30" 14" GLASS MIRROR WITH 15 YEAR

WARRANTY ON SILVERING; 304 STAINLESS STEEL

WELDED CHANNEL FRAME WITH SATIN FINISH,

GALVANIZED STEEL BACK

A

TOILET ROOM ACCESSORY SCHEDULE

PROVIDE MANUFACTURER & MODEL LISTED, OR

APPROVED EQUIVALENT.

B TOILET TISSUE DISPENSER: BOBRICK B-667

SINGLE ROLL RECESSED DISPENSER,

304 STAINLESS STEEL SATIN FINISH,

WITH CHROME PLATED PLASTIC SPINDLE

C INSTALL HAMPTON 30 IN. W X 12 IN. D X 42 IN. H

ASSEMBLED WALL KITCHEN CABINET IN SATIN

WHITE, OR EQUIVALENT, AS SHOWN IN THE

DRAWING.

D NOT USED

E NOT USED

GRAB BARS: 11/2" DIAMETER, 304 STAINLESS STEEL

TUBING, SATIN FINISH, CONCEALED MOUNTING

FLANGE WITH 31/4" DIAMETER COVER.

INSTALL AT MIN. 33" TO MAX. 36" FROM

FINISH FLR. TO TOP OF GRAB BAR UNLESS

OTHERWISE NOTED.

PROVIDE SOLID 2 X12 WOOD BLOCKING FOR

ALL GRAB BARS AND WALL MOUNTED FIXTURES

AS REQUIRED BY MANUFACTURERS, TYP

G18 BOBRICK B-6806X18"

G36 BOBRICK B-6806X36"

G42 BOBRICK B-6806X42"

G24 BOBRICK B-6803X24"

> ALL FIXTURES SHALL BE NEW.

> ALL PLUMBING FIXTURES SHALL BE ADA COMPLIANT.

> ALL FIXTURES SHALL BE INSTALLED AS PER ICC A117.1.2009

KEYED NOTES:

BLOCKING NOTE:

PROVIDE 2X BLOCKING AT 12" O.C. BETWEEN

EXISTING FLOOR JOISTS AT SHOWER TO BATHROOM FLOOR

TRANSITION, TYP.

CONTRACTOR NOTE:

> WHERE NEW WALL FRAMING LANDS OFFSET FROM FLOOR

JOISTS AND CEILING RAFTERS, PROVIDE 2X BRIDGING AT

16" O.C, TYP.

G

G48 BOBRICK B-6806X48"

PROVIDE SHOWER TRENCH DRAIN: NEODRAIN (OR EQUAL) LINEAR

SHOWR DRAIN WITH QUADRATO PATTERN GRATE, PROFESSIONAL

BRUSHED 304 STAINLESS STEEL RECTANGULAR SHOWER FLOOR

DRAIN MANUFACTURER, FLOOR SHOWER DRAIN WITH LEVELING FEET,

HAIR STRAINER. SIZE: AS PER DRAWING.

P5INSTALL UNFACED ROCK WOOL FIBERGLASS SOUND ATTENUATION

BATTS IN BATHROOM WALLS.

INSTALL ADDITIONAL BATT INSULATION AT ROOF RAFTERS.4a

INSTALL NEW BATT INSULATION AT EXPOSED EXTERIOR WALL.4c

INSTALL BATT INSULATION AT FLOOR JOISTS4b

F NOT USED

THESE DOCUMENTS CONTAIN POTENTIALLY SENSITIVE

INFORMATION AND SHAL BE USED FOR THEIR

INTENDED PURPOSE. ONCE THE INTENDED PURPOSE

HAS CEASD, THE DOCUMENTS SHALL BE DSTROYED IN

A SECURE MANNER.

IT IS A VIOLATION OF STATE EDUCATION LAW FOR ANY

PERSON UNLESS UNDER HE DIRECTION OF A LICENSED

ARCHITECT/ENGINEER TO ALTER THIS DOCUMENT IN

ANYWAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED

ALONG WITH A DESRIPTION OF THE ALTERATINS, DATE

AND ARCHITECT'S/ENGINEER'S SIGNATURE.

COPYRIGHT©2026

Consultants:

HUQ ENGINEERING CONSULTANCY, PLLC

37-15 73rd St, Room 203 Jackson Heights, NY 11372

Phone: 646 283 7675

Drawing Title:

Job Number:

Drawing Number:

A101 Sheet Number:

xxxx

Project:

PROPOSED 1ST FLOOR

BATHROOM PLANS

Client:

OFFICE FOR PEOPLE WITH

DEVELOPMENTAL DISABILITIES

620 Westfall Rd, Rochester, NY 14620

FINGER LAKES DDSO

Project Key:

DateDescription Submissions/Revisions:

Marshall Road IRA - Bathroom Design 1519 Marshall Rd, Waterloo, NY 13165

09/14/202690% Permit Set

SCALE: NOT TO SCALE

KEY PLAN1

A201

WH

CABINET

1'-7"

T

N

13A201

STANDING

BATH AREA

A201

A201

A201

A201

A201

14A201

SCALE: NOT TO SCALE

BLOCKING DETAIL10

A201

PROVIDE NEW

UNFACEDSOUND

BATTS AS INDICATED

ON PLAN, TYP.

PROVIDE INSULATION

AT BACK SIDE OF

BLOCKING AT

EXTERIOR WALL, TYP.

PROVIDE AND INSTALL

2x6 BLOCKING

BETWEEN EXISTING

WALL STUD FRAMING.

FASTENER AS

RECOMMENDED BY

MANUFACTURER

6"EPOXY MORTAR

(TOP LAYER) BACKER BOARD

1ST LAYER OF CDX PLYWOOD - GLUED

& SCREWED TO FLOOR JOISTS

(2) 2x6 WOOD BLOCKING AT

PERIMETER OF NEW PLYWOOD

AND FLOOR OR SHOWER DRAIN, TYP.

PROVIDE 12" SQUARE 1

2" MARINE

GRADE PLYWOOD SHIM, GLUED AND

SCREWED TO BASE PLYWOOD, TYP,

DRAIN BODY, TYP.

TILED FLOOR FINISH.

TERMINATE AT DRAIN W/KEYED EDGE

PROVIDE FLOOR/SHOWER DRAIN:

SIOUX CHIEF SERIES 822 2" DRAIN

WITH ROUND STAINLESS STEEL

VANDAL RESISTANT STRAINER OR

APPROVED EQUIVALENT. PROVIDE

DRAIN BODY EXTENSION AS

REQUIRED TO ACCOMMODATE

FLOOR PITCH, TYP. CONTRACTOR

TO PREPARE STAINLESS STEEL

DRAIN BODY FLANGE AS

REQUIRED FOR MORTAR AND

EPOXY COAT.

SCALE: NOT TO SCALE

FLOOR DRAIN DETAIL11

A201

CONTRACTOR NOTE:

DOOR FRAME, BEYOND

NEW THRESHOLD

EXISTING FLOOR AT HALL

WAY

PROVIDE 2X BLOCKING UNDER

MARBLE DOOR THRESHOLD

EXISTING FLOOR

JOISTS (BATHROOM)

EXISTING PLYWOOD

SUB-FLOOR TO REMAIN

REMOVE PLYWOOD SUB-FLOOR TO

EXPOSE EXISTING FRAMING. REMOVE

ALL NAILS, SCREWS & ADHESIVES

FROM FRAMING.

PITCH 1%

PLYWOOD.

BACKER BOARD

EPOXY MORTAR

PORCELAIN FLOOR TILES

SCALE: NOT TO SCALE

THRESHOLD DETAIL12

A201

EXISTING CEILING

FRAMING TO REMAIN, TYP.

CONTRACTOR NOTE:

2x FURRING @ SHOWER

MIXING VALVE WALL

1/2" GYPSUM BOARD

VAPOR RETARDER, TYP.

OUTSIDE SURFACE FINISH

TO REMAN

ROCKWOOL (OR EQ.)

UNFACED SOUND BATTS AS

INDICATED ON PLAN, TYP.

EXISTING WALL FRAMING TO

REMAIN, TYP.

VAPOR RETARDER AT

BATHROOM INTERIORS, TYP.

1/2" GYPSUM BOARD TYPE MR

AT BATHROOM CEILINGS, TYP.

3/8" SOLID SURFACE PANEL, TYP.

-INSTALL PER MANUFACTURER'S

INSTALLATION INSTRUCTIONS

1/2" USG DUROCK ULTRA LIGHT

FOAM BACKER BOARD (OR

EQUIVALENT), TYP.

SILICONE ADHESIVE, TYP. PER

SOLID SURFACE MANUFACTURER'S

INSTALLATION INSTRUCTIONS

VAPOR RETARDER

EX'G WOOD BASE MOLDING.

EXISTING FLOOR FRAMING

TO REMAIN - 2 ROWS OF

WOOD BLOCKING TO

STIFFEN FLOOR JOISTS

-UNFACED BATT INSULATION

EX'G 2x WOOD BLOCKING AT

EDGES OF PLYWOOD

EXISTING PLYWOOD

SUB-FLOOR TO REMAIN

REMOVE PLYWOOD SUB-FLOOR TO

EXPOSE EXISTING FRAMING. REMOVE

ALL NAILS, SCREWS & ADHESIVES FROM

FRAMING.

PITCH 1% MAX.

1/2" USG DUROCK ULTRA LIGHT

FOAM BACKER BOARD

6 MIL MOISTURE BARRIER MEMBRANE.

EPOXY MORTAR, MAX PITCH 1%.

DALTILE (STEPWISE) PORCELAIN

FLOOR TILES

SHOWER SIDE

SILICONE ADHESIVE, TYP. PER

SOLID SURFACE MANUFACTURER

INSTALLATION INSTRUCTIONS

1/4" SOLID SURFACE PANELS, TYP.

-INSTALL PER MANUFACTURER'S

INSTALLATION GUIDE

SCALE: NOT TO SCALE

WALL DETAIL (IN SHOWER)13

A201

SCALE: NOT TO SCALE

WALL DETAIL (OUTSIDE SHOWER)14

A201

EXISTING PLYWOOD

SUB-FLOOR TO REMAIN

REMOVE PLYWOOD SUB-FLOOR TO EXPOSE

EXISTING FRAMING. REMOVE ALL NAILS,

SCREWS & ADHESIVES FROM FRAMING.

EXISTING FLOOR FRAMING

TO REMAIN

EXISTING FLOOR FINISH,

OUTSIDE, TYP.

EXISTING WALL FRAMING

AND OUTSIDE FINISHES TO

REMAIN, TYP.

VAPOR RETARDER

ROCKWOOL (OR EQ.)

UNFACED SOUND BATTS AS

INDICATED ON PLAN, TYP.

EXISTING CEILING

FRAMING TO REMAIN, TYP.

1/2" GYPSUM BOARD TYPE MR

AT BATHROOM CEILINGS, TYP.

SILICONE SEALANT, TYP.

1/2" MOISTURE RESISTANT

GYPSUM BOARD,TYP.

1/2" TYPE MR GYPSUM BOARD, TYP.

SILICONE ADHESIVE, TYP. PER

SOLID SURFACE MANUFACTURER'S

INSTALLATION INSTRUCTIONS

1/2" USG DUROCK ULTRA LIGHT

FOAM TILE BACKER BOARD

(OR EQUIVALENT), TYP.

3/8" THICK SOLID SURFACE PANELS

INSTALLED PER MANUFACTURERS

INSTALLATION GUIDE. CONSULT DDSO

WITH COLOR SELECTION.

EPOXY MORTAR, MAX PITCH 1%.

3/4" CDX PLYWOOD.

CONTRACTOR TESTING NOTE:CONTRACTOR NOTE:

RP2503.5 DRAIN, WASTE AND VENT SYSTEMS TESTING. ROUGH-IN AND FINISHED

PLUMBING INSTALLATIONS OF DRAIN, WASTE AND VENT SYSTEMS SHALL BE

TESTED INACCORDANCE WITH SECTIONS RP2503.5.1, RP2503.5.2. AND SHALL

CONDUCT THESE TESTS WITH DDSO FIELD REPRESENTATIVE PRESENT.

RP2503.5.1 ROUGH PLUMBING. DWV SYSTEMS SHALL BE TESTED ON COMPLETION

OF THE ROUGH PIPING INSTALLATION BY WATER OR, FOR PIPING SYSTEMS OTHER

THAN PLASTIC, BY AIR, WITHOUT EVIDENCE OF LEAKAGE. EITHER TEST SHALL BE

APPLIED TO THE DRAINAGE SYSTEM IN ITS ENTIRETY OR IN SECTIONS AFTER

ROUGH-IN PIPING HAS BEEN INSTALLED, AS FOLLOWS:

1. WATER TEST. EACH SECTION SHALL BE FILLED WITH WATER TO A POINT NOT

LESS THAN 5 FEET (1524 MM) ABOVE THE HIGHEST FITTING CONNECTION IN

THAT SECTION, OR TO THE HIGHEST POINT IN THE COMPLETED

SYSTEM. WATER SHALL BE HELD IN THE SECTION UNDER TEST FOR A

PERIOD OF 15 MINUTES. THE SYSTEM SHALL PROVE LEAK FREE BY VISUAL

INSPECTION.

2. AIR TEST. THE PORTION UNDER TEST SHALL BE MAINTAINED AT A GAUGE

PRESSURE OF 5 POUNDS PER SQUARE INCH (PSI) (34 KPA) OR 10 INCHES OF

MERCURY COLUMN (34 KPA). THIS PRESSURE SHALL BE HELD WITHOUT

INTRODUCTION OF ADDITIONAL AIR FOR A PERIOD OF 15 MINUTES.

3. RP2503.07 WATER SUPPLY SYSTEM TESTING. UPON COMPLETION

OF THE WATER SUPPLY SYSTEM OR SECTION OF IT, THE SYSTEM OR

PORTION COMPLETED SHALL BE TESTED AND PROVED TIGHT UNDER A

WATER PRESSURE OF NOT LESS THAN THE WORKING PRESSURE OF THE

SYSTEM OR, FOR PIPING SYSTEMS OTHER THAN PLASTIC, BY AN AIR TEST

OF NOT LESS THAN 50 PSI (345 KPA). THIS PRESSURE SHALL BE HELD FOR

NOT LESS THAN 15 MINUTES. THE WATER USED FOR TESTS SHALL BE

OBTAINED FROM A POTABLE WATER SOURCE

1. THE CONTRACTOR SHALL PROVIDE A SHOWER LINER TEST IN ACCORDANCE

WITH NYSRP 2503.6. WHERE SHOWER FLOORS AND RECEPTORS ARE MADE

WATERTIGHT BY THE APPLICATION OF MATERIALS REQUIRED BY SECTION

RP2709.2, THE COMPLETED LINER INSTALLATION SHALL BE TESTED. THE PIPE

FROM THE SHOWER DRAIN SHALL BE PLUGGED WATERTIGHT FOR THE TEST.

THE FLOOR AND RECEPTOR AREA SHALL BE FILLED WITH POTABLE WATER TO

A DEPTH OF NOT LESS THAN 2 INCHES (51 MM) MEASURED AT THE

THRESHOLD. WHERE A THRESHOLD OF NOT LESS THAN 2 INCHES (51 MM) IN

HEIGHT DOES NOT EXIST, A TEMPORARY THRESHOLD SHALL BE

CONSTRUCTED TO RETAIN THE TEST WATER IN THE LINED FLOOR OR

RECEPTOR AREA TO A LEVEL NOT LESS THAN 2 INCHES (51 MM) IN DEPTH

MEASURED AT THE THRESHOLD. THE WATER SHALL BE RETAINED FOR A TEST

PERIOD OF NOT LESS THAN 15 MINUTES AND THERE SHALL NOT BE EVIDENCE

OF LEAKAGE.

2. THE CONTRACTOR SHALL PROVIDE FINISHED PLUMBING TESTS

INACCORDANCE WITH NYSRP 2503.5.2 AFTER THE PLUMBING FIXTURES HAVE

BEEN SET AND THEIR TRAPS FILLED WITH WATER, THEIR CONNECTIONS

SHALL BE TESTED AND PROVED GAS TIGHT OR WATERTIGHT AS FOLLOWS:

3. WATER TIGHTNESS. EACH FIXTURE SHALL BE FILLED AND THEN DRAINED.

TRAPS AND FIXTURE CONNECTIONS SHALL BE PROVEN WATERTIGHT BY

VISUAL INSPECTION.

4. GAS TIGHTNESS. WHERE REQUIRED BY THE LOCAL ADMINISTRATIVE

AUTHORITY, A FINAL TEST FOR GAS TIGHTNESS OF THE DWV SYSTEM SHALL

BE MADE BY THE SMOKE OR PEPPERMINT TEST. ALL TESTING SHALL BE

CONDU

5. ALL TESTING SHALL BE CONDUCTED WITH DDSO FIELD REPRESENTATIVE

PRESENT

6. PROVIDE 2X BLOCKING AS REQUIRED AT ALL HAND RAIL MOUNTING POINTS

PITCH 1% MAX

PER/FT

1. REFER TO MANUFACTURERS

SURFACE PREP GUIDELINES.

2. PROVIDE 2x8 BRIDGING AT 12"

O.C. BETWEEN FLOOR JOISTS AND

SHIM UNDER EXISTING WALL

FRAMING WHERE WALL IS

PARALLEL TO EXISTING FLOOR

FRAMING

3/4" CDX PLYWOOD.

SILICONE ADHESIVE, TYP. PER

SOLID SURFACE MANUFACTURER'S

INSTALLATION INSTRUCTIONS

1/2" USG DUROCK ULTRA LIGHT

FOAM TILE BACKER BOARD

DALTILE (STEPWISE) PORCELAIN

FLOOR TILES

SILICONE ADHESIVE, TYP.

EXISTING FLOOR

JOISTS (HALLWAY)

TILES

GRAB BAR

1/2" PVC BULL NOSE TILE EDGE TRIM

EXISTING FLOOR

SUBSTRATE

NOTE:

ONLY INSIDE SURFACES OF THE BATHROOM WILL BE

DEMOLISHED AND RECONSTRUCTED. THE OUTSIDE

SURFACES WILL REMAIN AS IS.

EX'G 2x WOOD

BLOCKING AT EDGES

OF PLYWOOD

THESE DOCUMENTS CONTAIN POTENTIALLY SENSITIVE

INFORMATION AND SHAL BE USED FOR THEIR

INTENDED PURPOSE. ONCE THE INTENDED PURPOSE

HAS CEASD, THE DOCUMENTS SHALL BE DSTROYED IN

A SECURE MANNER.

IT IS A VIOLATION OF STATE EDUCATION LAW FOR ANY

PERSON UNLESS UNDER HE DIRECTION OF A LICENSED

ARCHITECT/ENGINEER TO ALTER THIS DOCUMENT IN

ANYWAY. ALTERATIONS MUST HAVE THE SEAL AFFIXED

ALONG WITH A DESRIPTION OF THE ALTERATINS, DATE

AND ARCHITECT'S/ENGINEER'S SIGNATURE.

COPYRIGHT©2026

Consultants:

HUQ ENGINEERING CONSULTANCY, PLLC

37-15 73rd St, Room 203 Jackson Heights, NY 11372

Phone: 646 283 7675

Drawing Title:

Job Number:

Drawing Number:

A201 Sheet Number:

xxxx

Project:

DETAILS

Client:

OFFICE FOR PEOPLE WITH

DEVELOPMENTAL DISABILITIES

620 Westfall Rd, Rochester, NY 14620

FINGER LAKES DDSO

Project Key:

DateDescription Submissions/Revisions:

Marshall Road IRA - Bathroom Design 1519 Marshall Rd, Waterloo, NY 13165

09/14/202690% Permit Set

T-100.pdf
Sheets and Views
T-100
G-001
Sheets and Views
G-001
D-101
Sheets and Views
D-101
A-101
Sheets and Views
A-101
A-201
Sheets and Views
A-201

File details come from the government source that posted it. Updated .