| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1010 | MA-1010-01-007-AV | 1000 / 0003 | Low | Chicago | b641 | 3/4 | Slop sink with AV located in janitor's closet north of old gymnasium |
| 1010 | MA-1010-01-008-AV | 1000 / 0595 | Low | Watts | NF 8 | 3/4" | Hose bibb in womens locker room, near jacuzzi |
| 1010 | MA-1010-01-009-AV | 1000 / 0596 | Low | Arrowhead | #58 ABP | 3/4" | Hose bibb in womens locker room |
| 1010 | MA-1010-OO-001-AV | 1000 / 0004 | Low | Watts | NF 8 | 3/4 | Hand hydrant with AV located northeast of building and southeast of running track |
| 1010 | MA-1010-OO-002-AV | 1000 / 0005 | Low | Watts | NF 8 | 3/4 | Hand hydrant with AV located east of running track |
| 1010 | MA-1010-OO-003-AV | 1000 / 0006 | Low | Watts | NF 8 | 3/4 | Hand hydrant with AV located northeast of running track |
| 1010 | MA-1010-01-004-AV | 1000 / 0007 | Low | Arrowhead | #58 ABP | 3/4 | Hose bibb with AV on main water supply located on east wall near entrance |
| 1010 | MA-1010-01-005-RP | 1000 / 0008 | High | Watts | 909 MOD QT | 1 | 1" RP on make-up water to steam boiler located in east end of room |
| 1010 | MA-1010-01-006-RP | 1000 / 0009 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on make-up water supply lines to steam boiler in west end of room, chiller, and both gymnasium Low Temperature Heating |
| 1012 | MA-1012-01-001-DC | 1000 / 0805 | Low | Watts | 709 | 4 | Used for main water supply, located in Mech Room |
| 1012 | MA-1012-01-002-DC | 1000 / 0806 | Low | Ames | 200 | 4 | Backflow used on the main fire suppression system, for the gym, located just inside the Mech Room on the left. |
| 102 | MA-102-OO-001-RP | 1000 / 0010 | High | Watts | 9 | 3 | 3" RP on water supply line to irrigation located in park, west of building in concrete block enclosure |
| 1062 | MA-1062-01-005-AV | 1000 / 0011 | Low | T&S | b969 | 3/4 | Slop sink with AV located in janitor's closet |
| 1062 | MA-1062-OO-001-AV | 1000 / 0012 | Low | Arrowhead | #58 ABP | 3/4 | Hose bibb with AV located on north wall outside north mechanical room door |
| 1062 | MA-1062-03-007-AV | 1000 / 0013 | Low | T&S | b969 | 3/4 | Slop sink with AV located in janitor's closet |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1062 | MA-1062-02-006-AV | 1000 / 0014 | Low | T&S | B969 | 3/4 | Slop sink with AV located in janitor's closet |
| 1062 | MA-1062-01-002-DC | 1000 / 0015 | Low | Ames | 2000 SS | 3 | 3" DC on water supply line to fire suppression system located on west wall |
| 1062 | MA-1062-01-003-RP | 1000 / 0016 | High | Watts | 009 M2 QT | 1.5 | 1.5" RP on water supply line to irrigation located on east end of north wall (bottom assembly) |
| 1062 | MA-1062-01-004-RP | 1000 / 0017 | High | Wilkins Zurn | 975 XL | 3/4 | 3/4" RP on make-up water supply lines to both chiller and heating systems located on east end of north wall (top assembly) |
| 1075 | MA-1075-01-008-AV | 1000 / 0018 | Low | Watts | 288A | 1/2 | 1/2" AV on water supply line to dishwasher on top of machine (south device) located on east wall |
| 1075 | MA-1075-01-001-AV | 1000 / 0029 | Low | Watts | 288A | 1/2 | 1/2" AV on water supply line to disposal unit located on north wall |
| 1075 | MA-1075-01-016-AV | 1000 / 0020 | Low | Chicago | B641 | 3/4 | Sink faucet with AV located in southeast corner |
| 1075 | MA-1075-01-014-AV | 1000 / 0021 | Low | Chicago | b641 | 3/4 | Slop sink with AV on west wall in janitor's closet, south of east dining room |
| 1075 | MA-1075-01-011-AV | 1000 / 0022 | Low | Arrowhead | No. 58 abp | 3/4 | Hose bibb with AV located on south end of west wall adjacent to hand wash sink |
| 1075 | MA-1075-01-010-AV | 1000 / 0023 | Low | Arrowhead | No. 58 abp | 3/4 | Hose bibb with AV located south of triple basin sink on west wall |
| 1075 | MA-1075-01-009-AV | 1000 / 0024 | Low | Watts | 288A | 1/2 | 1/2" AV on water supply line to disposal unit located south of dishwashing machine |
| 1075 | MA-1075-01-007-AV | 1000 / 0025 | Low | Watts | 288A | 3/4 | 3/4" AV on water supply line to dishwasher on top of machine (north device) located on east wall |
| 1075 | MA-1075-01-006-AV | 1000 / 0026 | Low | Watts | 288A | 1/2 | 1/2" AV on water supply line to disposal unit located on west wall of dishwasher room |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1075 | MA-1075-01-005-AV | 1000 / 0027 | Low | Watts | 288A | 1/2 | 1/2" AV on water supply line to disposal unit located on north wall |
| 1075 | MA-1075-01-004-AV | 1000 / 0030 | Low | T&S | B969 | 3/4 | Slop sink with AV in card board eater room |
| 1075 | MA-1075-01-002-AV | 1000 / 0019 | Low | Watts | 288A | 1/2 | 1/2" AV on water supply to kettle pot fill station located on east end (south device) |
| 1075 | MA-1075-01-003-AV | 1000 / 0028 | Low | Watts | 288A | 1/2 | 1/2" AV on water supply to kettle pot fill station located on east end (north device) |
| 1075 | MA-1075-01-012-DC | 1000 / 0031 | Low | Ames | 2000 SS | 6 | 6" DC on water supply line to fire suppression system located in northeast corner janitor's closet, south of east dining room |
| 1075 | MA-1075-01-013-RP | 1000 / 0032 | High | Watts | 009 M2 QT | 1.5 | 1.5" RP on water supply line to irrigation located on south wall in janitor's closet, south of east dining room |
| 1075 | MA-1075-01-017-RP | 1000 / 0033 | High | Watts | 909M1QT | 1.5" | 1 1/2" RP on make-up water to steam boiler located next to water softener approx. 5' high. |
| 1075 | MA-1075-02-015-RP | 1000 / 0034 | High | Watts | 009 M2 QT | 3/4 | 3/4" RP on water supply line to hose bibb with AV located adjacent to chemical feed/make-up water tank for chiller system and w |
| 1082 | MA-1082-OO-006-AV | 1000 / 0035 | Low | Watts | NF8 | 3/4 | Hand hydrant with AV located in grassy area east of building and adjacent to Goddard Drive |
| 1082 | MA-1082-OO-002-AV | 1000 / 0036 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west wall between mechanical room doors |
| 1082 | MA-1082-01-005-AV | 1000 / 0037 | Low | Chicago | B641 | 3/4 | Slop sink with AV located in janitor's closet |
| 1082 | MA-1082-OO-001-PV | 1000 / 0038 | High | Wilkins | 720 A | 1 | 1" PV on water supply line to irrigation located on southeast corner just outside mechanical room |
| 1082 | MA-1082-01-003-RP | 1000 / 0039 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on make-up water supply line to steam boiler located in southeast corner |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1082 | MA-1082-01-004-RP | 1000 / 0040 | High | Watts | 909 MOD HW 210 | 3/4 | 3/4" RP on make-up water supply line Low Temperature Heating System located on west end near ceiling above package chiller |
| 1084 | MA-1084-01-001-AV | 1000 / 0041 | Low | Chicago | b641 | 3/4 | Slop sink with AV located in janitor's closet |
| 1145 | MA-1145-OO-002-AV | 1000 / 0043 | Low | Watts | NF8 | 3/4 | Hand hydrant with AV located east of north end of building in grassy area adjacent to Goddard Drive |
| 1145 | MA-1145-OO-003-AV | 1000 / 0044 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south wall adjacent to southwest mechanical room door |
| 1145 | MA-1145-OO-001-AV | 1000 / 0042 | Low | Watts | NF8 | 3/4 | Hand hydrant with AV located east of center of building in grassy area adjacent to Goddard Drive |
| 1145 | MA-1145-OO-005-AV | 1000 / 0045 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of west wall |
| 1145 | MA-1145-01-006-DC | 1000 / 0644 | Low | Ames | Maxim 200 | 4 | 4" DC on fire suppression system located in mechanical room (southwest corner). |
| 1145 | MA-1145-01-004-RP | 1000 / 0046 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located in center of room |
| 1150 | MA-1150-OO-009-AV | 1000 / 0049 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south end of east wall |
| 1150 | MA-1150-OO-006-AV | 1000 / 0056 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of south wall adjacent to AC cooling fans |
| 1150 | MA-1150-OO-010-AV | 1000 / 0047 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located south of main entrance on east wall |
| 1150 | MA-1150-00-012-DC | 1000 / 0645 | Low | Ames | Maxim 200 | 6" | 6" DC on fire suppression system located in rear mechanical room. |
| 1150 | MA-1150-OO-008-AV | 1000 / 0050 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south wall in corner |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1150 | MA-1150-OO-007-AV | 1000 / 0051 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south end of west wall adjacent to break area and picnic table |
| 1150 | MA-1150-OO-003-AV | 1000 / 0053 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north end of west wall |
| 1150 | MA-1150-OO-002-AV | 1000 / 0054 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located east of shoppette entranceon center of north wall |
| 1150 | MA-1150-OO-001-AV | 1000 / 0055 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east end of north wall |
| 1150 | MA-1150-OO-004-AV | 1000 / 0052 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south end of west wall |
| 1150 | MA-1150-OO-011-AV | 1000 / 0048 | Low | Watts | NF8 | 3/4 | Hand hydrant with AV located east of main entrance in grassy area adjacent to Goddard Drive |
| 1150 | MA-1150-01-005-RP | 1000 / 0057 | High | Watts | 009 MOD CW | 1 | 1" RP on make-up water supply lines to chiller and Low Temperature Heating System located in northwest corner |
| 1150 | MA-1150-01-001-PV | 1000 / 0597 | High | Wilkens | 720A | 2" | Irrigation system in Grassy area along Goddard Ave. |
| 1152 | MA-1152-OO-001-AV | 1000 / 0058 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of west wall |
| 1152 | MA-1152-OO-002-AV | 1000 / 0059 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south end of east wall near mechanical room door |
| 1152 | MA-1152-01-003-RP | 1000 / 0062 | High | Watts | 009 MQT | 2 | 2" RP on main water supply line to building located approximately 12' high on the south wall |
| 1152 | MA-1152-01-004-RP | 1000 / 0060 | High | Watts | 800 M4 | 1.5 | 1.5" RP on water supply line to irrigation approximately 12' high above entrance door and ventilation ductwork |
| 1152 | MA-1152-01-005-RP | 1000 / 0061 | High | Watts | 909 QT | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located on north wall |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1154 | MA-1154-OO-003-AV | 1000 / 0064 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of north wall |
| 1154 | MA-1154-OO-002-AV | 1000 / 0065 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east end of north wall |
| 1154 | MA-1154-01-004-DC | 1000 / 0066 | Low | Ames | 2000 SS | 3 | 3" DC on water supply line to fire suppression system located in northeast corner of building |
| 1154 | MA-1154-01-001-RP | 1000 / 0067 | High | Watts | 909 MOD CW | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located on south wall |
| 1156 | MA-1156-01-003-AV | 1000 / 0068 | Low | T&S | b969 | 3/4 | Slop sink with AV located in janitor's closet |
| 1156 | MA-1156-01-004-AV | 1000 / 0069 | Low | T&S | b969 | 3/4 | Slop sink with AV in concession storage room |
| 1156 | MA-1156-01-005-DC | 1000 / 0070 | Low | Ames | HB-0892 | 4" | DC on Fire System in Mech room, south side wall |
| 1180 | MA-1180-01-001-DC | 1000/0822 | Low | Watts | 757 | 3" | DC on water supply line located in mechanical room along west wall. |
| MA-1180-01-002-DC | 1000/0823 | Low | Ames | 2000 SS | 6" | DC on Fire System in Mech room, south side wall | |
| MA-1180-01-003-RP | 1000/0824 | High | Watts | 009 | 1/2 inch | Located on boiler makeup line in center of mechanical room. | |
| 1191 | MA-1191-OO-003-AV | 1000 / 0072 | Low | Watts | NF8 | 3/4 | Hand hydrant with AV located northwest of building on west side of parking lot |
| 1191 | MA-1191-OO-004-AV | 1000 / 0073 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV on standpipe located southeast of building, east of sidewalk, and south of display rocket |
| 1191 | MA-1191-OO-002-PV | 1000 / 0074 | High | Wilkins | 720 A | 2 | 2" PV on water supply line to irrigation located on north side of building near mechanical room |
| 1191 | MA-1191-01-001-RP | 1000 / 0075 | High | Watts | 909 MOD CW | 1 | 1" RP on make-up water supply line to Low Temperature Heating System located west of center of room |
| 1192 | MA-1192-OO-003-AV | 1000 / 0076 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east end of south wall |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1192 | MA-1192-01-001-RP | 1000 / 0078 | High | Watts | 909 MOD CW | 3/4 | 3/4" RP on make-up water supply line to chiller located approximately 8' high in southeast corner on south wall |
| 1192 | MA-1192-01-002-RP | 1000 / 0079 | High | Watts | 909 MOD CW | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located in middle of room |
| 1199 | MA-1199-OO-001-AV | 1000 / 0080 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of north wall |
| 1199 | MA-1199-OO-004-AV | 1000 / 0081 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north end of west wall |
| 1199 | MA-1199-BM-002-RP | 1000 / 0082 | High | Watts | 009 M2 QT | 2 | 2" RP on water supply line to irrigation located in northeast corner |
| 1199 | MA-1199-BM-003-RP | 1000 / 0083 | High | Watts | 909 MOD CW | 3/4 | 3/4" RP on make-up water supply line to chiller located in southwest corner of room behind pumps and heat exchanger |
| 120 | MA-120-01-001-RP | 1000 / 0598 | High | Watts | 909QT RPZ | 3/4 | 3/4" RP On water supply line to boiler make-up Located in Janitors closet along East wall. |
| 1199 | MA-1199-BM-005-RP | 1000 / 0084 | High | Wilkins Zurn | 975 XL | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located on west wall behind air handler |
| 1203 | MA-1203-OO-002-AV | 1000 / 0085 | Low | Watts | NF8 | 3/4 | H.H. w/ AV located at N.E. corner of restroom facility 1201 at sun plaza park |
| 1203 | MA-1202-OO-001-PV | 1000 / 0086 | High | Wilkins | 720 A | 2 | 2" PV on water supply line to irrigation located southeast of gazebo 1202 |
| 1222 | MA-1222-01-005-AV | 1000 / 0087 | Low | Watts | 288A | 3/4 | 3/4" AV on water supply line to domestic hot water heater located in northwest corner |
| 1222 | MA-1222-01-004-AV | 1000 / 0088 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south wall, west of entrance and adjacent to fire suppression system water supply |
| 1222 | MA-1222-01-001-DC | 1000 / 0089 | Low | Ames | 2000 SS | 4 | 4" DC on water supply line to fire suppression system located on south wall |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1222 | MA-1222-01-003-RP | 1000 / 0090 | High | Watts | 909 | 3/4 | 3/4" RP on make-up water supply line to boiler located near west wall approximately 15' high |
| 1222 | MA-1222-01-002-RP | 1000 / 0091 | High | Watts | 909 | 2 | 2" RP on main water supply line to building located in southwest corner approximately 15' high |
| 1240 | MA-1240-OO-003-AV | 1000 / 0092 | High | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located below grade in dirt immediately northeast of main entrance |
| 1240 | MA-1240-01-001-AV | 1000 / 0093 | High | Watts | 288A | 1 | 1" AV on water supply line to irrigation located in northwest corner |
| 1240 | MA-1240-01-004-AV | 1000 / 0094 | Low | T&S | b969 | 3/4 | Slop sink with AV located in janitor's closet in southeast corner of building |
| 1240 | MA-1240-01-005-AV | 1000 / 0095 | Low | T&S | b969 | 3/4 | Slop sink with AV in men's room |
| 1240 | MA-1240-01-002-RP | 1000 / 0096 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on make-up water supply line to boiler located in northeast corner adjacent to boiler |
| 1246 | MA-1246-01-003-AV | 1000 / 0097 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north end of west wall |
| 1246 | MA-1246-01-004-OT | 1000 / 0098 | High | Watts | 9D | 3/4 | 3/4" BPD with atmospheric vent located on water supply line to water heater for concrete bay floors |
| 1246 | MA-1246-OO-001-PV | 1000 / 0099 | High | Watts | 800 M4FR | 1 | 1" PV on water supply line to irrigation located on north end of east wall near mechanical room door |
| 1246 | MA-1246-01-002-RP | 1000 / 0100 | High | Watts | 009 M2 QT | 2 | 2" RP on main water supply line to building located in southwest corner |
| 1248 | MA-1248-01-007-AV | 1000 / 0101 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV on roof support pole located on west end of service bay |
| 1248 | MA-1248-OO-013-AV | 1000 / 0110 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of south wall |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1248 | MA-1248-OO-012-AV | 1000 / 0102 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of north wall |
| 1248 | MA-1248-01-014 - PV | 1000 / 762 | High | Watts | 800M4 | 1.5" | 1 1/2" PVB for irrigation located on west side of building on the exterior side of kiln room emergency exit. |
| 1248 | MA-1248-OO-002-AV | 1000 / 0103 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north end of east wall |
| 1248 | MA-1248-OO-001-AV | 1000 / 0104 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south end of east wall |
| 1248 | MA-1248-01-008-AV | 1000 / 0105 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east wall in southeast corner |
| 1248 | MA-1248-01-006-AV | 1000 / 0106 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV on roof support pole located on west end of service bay |
| 1248 | MA-1248-01-005-AV | 1000 / 0107 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV on roof support pole located on east end of service bay |
| 1248 | MA-1248-01-004-AV | 1000 / 0108 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV on roof support pole located on east end of service bay |
| 1248 | MA-1248-01-003-AV | 1000 / 0109 | Low | Chicago | B641 | 3/4 | Slop sink with AV in janitor's closet |
| 1248 | MA-1248-01-009-DC | 1000 / 0111 | Low | Ames | 2000 SS | 4 | 4" DC on water supply line to fire suppression system located on west wall |
| 1248 | MA-1248-01-010-RP | 1000 / 0112 | High | Febco | 825 Y | 2 | 2" RP on main water supply line to building located on west wall |
| 1248 | MA-1248-01-011-RP | 1000 / 0113 | High | Febco | 825 Y | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located approximately 12' high on the northwest end of r |
| 130 | MA-130-OO-004-AV | 1000 / 0114 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north wall west of mechanical room door |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 130 | MA-130-01-002-AV | 1000 / 0116 | Low | T&S | b969 | 3/4 | Slop sink with AV in janitor's closet |
| 130 | MA-130-01-003-RP | 1000 / 0117 | High | Watts | 009M2QT | 1.25 | 1.25" RP on water supply line to irrigation located on west wall |
| 1320 | MA-1320-OO-004-AV | 1000 / 0131 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east end of south wall |
| 1320 | MA-1320-OO-012-AV | 1000 / 0119 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north end of east wall |
| 1320 | MA-1320-OO-011-AV | 1000 / 0120 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east end of north wall |
| 1320 | MA-1320-OO-010-AV | 1000 / 0121 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of north wall |
| 1320 | MA-1320-OO-009-AV | 1000 / 0122 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north end of west wall, north of cardboard compactor |
| 1320 | MA-1320-01-026-DC | 1000 / 0646 | Low | Ames | Maxim 200 | 8 | 8" DC on fire suppression system located in rear of warehouse near loading docks. |
| 1320 | MA-1320-OO-008-AV | 1000 / 0123 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of west wall, north of electrical mechanical room |
| 1320 | MA-1320-OO-007-AV | 1000 / 0124 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south end of west wall between loading dock bay doors |
| 1320 | MA-1320-OO-005-AV | 1000 / 0125 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of south wall |
| 1320 | MA-1320-OO-003-AV | 1000 / 0126 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south end of east wall |
| 1320 | MA-1320-OO-002-AV | 1000 / 0118 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of east wall, south of building exit |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1320 | MA-1320-OO-001-AV | 1000 / 0127 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of east wall, north of building exit |
| 1320 | MA-1320-01-015-AV | 1000 / 0132 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south wall near steel sink |
| 1320 | MA-1320-01-014-AV | 1000 / 0140 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west wall of women's room |
| 1320 | MA-1320-01-024-AV | 1000 / 0128 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south wall in men's room near break room |
| 1320 | MA-1320-01-016-AV | 1000 / 0129 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north wall near steel sink |
| 1320 | MA-1320-01-017-AV | 1000 / 0134 | Low | Watts | 288A | 1/2 | 1/2" AV on water line located in southwest corner |
| 1320 | MA-1320-01-018-AV | 1000 / 0135 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV in restroom located between the meat and produce departments |
| 1320 | MA-1320-01-019-AV | 1000 / 0136 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV (hot and cold water) located north end of east wall |
| 1320 | MA-1320-01-021-AV | 1000 / 0138 | Low | Chicago | B641 | 3/4 | Slop sink with AV in janitor's closet located on northwest end of warehouse |
| 1320 | MA-1320-01-022-AV | 1000 / 0139 | Low | Chicago | B641 | 3/4 | Slop sink with AV in janitor's closet located east of warehouse |
| 1320 | MA-1320-01-023-AV | 1000 / 0133 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on north wall under sinks in women's room near break room |
| 1320 | MA-1320-01-020-AV | 1000 / 0137 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV attached to double basin steel sink |
| 1320 | MA-1320-01-013-AV | 1000 / 0130 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on north wall of men's room |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1320 | MA-1320-OO-006-RP | 1000 / 0141 | High | Watts | 909 M1 QT | 2 | 2" RP on water supply line to irrigation located in grassy area southwest of building |
| 1439 | MA-1439-01-014-AV | 1000 / 0145 | Low | T&S | b969 | 3/4 | Slop sink with AV located in janitor's closet in southwest corner of building |
| 1439 | MA-1439-01-010-AV | 1000 / 0149 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of north wall of southeast bay |
| 1439 | MA-1439-01-009-AV | 1000 / 0153 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located near eyewash station |
| 1439 | MA-1439-01-008-AV | 1000 / 0143 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south end of west wall |
| 1439 | MA-1439-01-007-AV | 1000 / 0144 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west wall near slop sink |
| 1439 | MA-1439-01-006-AV | 1000 / 0150 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south wall |
| 1439 | MA-1439-01-005-AV | 1000 / 0151 | Low | T&S | b969 | 3/4 | Slop sink with AV |
| 1439 | MA-1439-01-013-AV | 1000 / 0146 | Low | T&S | b969 | 3/4 | Hose bibb with AV located on south end of east wall |
| 1439 | MA-1439-01-004-AV | 1000 / 0152 | Low | T&S | b969 | 3/4 | Slop sink with AV |
| 1439 | MA-1439-01-011-AV | 1000 / 0148 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of south wall of southeast bay |
| 1439 | MA-1439-01-012-AV | 1000 / 0147 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north end of east wall |
| 1439 | MA-1439-01-003-DC | 1000 / 0154 | Low | Hersey | No. 2 | 8 | 8" DC on water supply line to fire suppression system located on north end of west wall |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1439 | MA-1439-01-002-PV | 1000 / 0155 | Low | Watts | 800M4 | 2 | 2" PV on water supply line to hot potable water system located in southeast corner |
| 1439 | MA-1439-01-001-RP | 1000 / 0156 | High | Watts | 909 MOD CW | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located on center of east wall |
| 1440 | MA-1440-01-012-AV | 1000 / 0176 | Low | Watts | 388a | 2 | 2" AV on 2" potable cold hose bib located on center of east wall approximately 15' high |
| 1440 | MA-1440-01-026-AV | 1000 / 0157 | Low | T&S | b969 | 3/4 | Slop sink with AV located on west wall |
| 1440 | MA-1440-01-025-AV | 1000 / 0164 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on center of west wall |
| 1440 | MA-1440-01-024-AV | 1000 / 0166 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on north end of west wall |
| 1440 | MA-1440-01-023-AV | 1000 / 0162 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on north end of east wall |
| 1440 | MA-1440-01-022-AV | 1000 / 0161 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on center of east wall |
| 1440 | MA-1440-01-020-AV | 1000 / 0160 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located near main water supply on south wall |
| 1440 | MA-1440-OO-001-AV | 1000 / 0159 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on north end of west wall |
| 1440 | MA-1440-OO-021-AV | 1000 / 0158 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on east wall |
| 1440 | MA-1440-01-013-AV | 1000 / 0163 | Low | Watts | 388a | 2 | 2" AV on 2" potable hot hose bib located on center of east wall approximately 15' high |
| 1440 | MA-1440-01-011-AV | 1000 / 0167 | Low | Watts | 388a | 2 | 2" AV on 2" potable hot hose bib located on north end of east wall approximately 15' high |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1440 | MA-1440-01-010-AV | 1000 / 0165 | Low | Watts | 388a | 2 | 2" AV on 2" potable cold hose bib located on north end of east wall approximately 15' high |
| 1440 | MA-1440-01-009-AV | 1000 / 0169 | Low | Watts | 388a | 2 | 2" AV on 2" potable hot hose bib located on north of west wall approximately 15' high |
| 1440 | MA-1440-01-008-AV | 1000 / 0170 | Low | Watts | 388a | 2 | 2" AV on 2" potable cold hose bib located on north end of west wall approximately 15' high |
| 1440 | MA-1440-01-007-AV | 1000 / 0171 | Low | Watts | 388a | 2 | 2" AV on 2" potable hot hose bib located on center of west wall approximately 15' high |
| 1440 | MA-1440-01-006-AV | 1000 / 0172 | Low | Watts | 388a | 2 | 2" AV on 2" potable cold hose bib located on center of west wall approximately 15' high |
| 1440 | MA-1440-01-005-AV | 1000 / 0173 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on center of east wall |
| 1440 | MA-1440-01-003-AV | 1000 / 0174 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on west wall |
| 1440 | MA-1440-01-002-AV | 1000 / 0175 | Low | Nidel | 34 hd | 3/4 | Hose bibb with AV located on west end of south wall |
| 1440 | MA-1440-01-015-AV | 1000 / 0168 | Low | T&S | b969 | 3/4 | Slop sink with AV in janitor's closet located on east wall of west bay |
| 1440 | MA-1440-01-019-PV | 1000 / 0177 | Low | Watts | 800 M4 QT | 2 | 2" PV on potable hot water supply line located above water heater (heat exchanger) where potable hot exits |
| 1440 | MA-1440-02-014-RP | 1000 / 0178 | High | Watts | 909 MOD CW | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located on second floor mezzanine mechanical area |
| 1440 | MA-1440-02-027-RP | 1000 / 0179 | High | Watts | 909 MOD | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located on second floor mezzanine mechanical area |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1440 | MA-1440-02-004-RP | 1000 / 0180 | High | Watts | 909 MOD CW | 3/4 | 3/4" RP on make-up water to Low Temperature Heating System located on east wall of second floor mezzanine mechanical area |
| 1440 | MA-1440-01-017-RP | 1000 / 0183 | High | Watts | 909 MOD QT | 2.5 | 2.5" RP on water supply line to potable hot water system located approximately 15' high in center of room |
| 1440 | MA-1440-01-016-RP | 1000 / 0182 | High | Watts | 909 MOD CW | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located in southeast corner of room |
| 1440 | MA-1440-01-018-RP | 1000 / 0181 | High | Watts | 909 | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located center of east end of room |
| 1441 | MA-1441-01-001-DC | 1000 / 0182 | Low | AMES | 2000SS | 6" | 6" AMES DC for Fire Suppression System |
| 1441 | MA-1441-01-002-DC | 1000 / 798 | Low | Watts | 007M | 3/4" | 3/4" DC on bypass line of Fire Suppression System |
| 1441 | MA-1441-01-003-DC | 1000 / 799 | Low | Watts | 709 | 2" | 2" DC located on main water feed to facility. |
| 1447 | MA-1447-OO-002-AV | 1000 / 0187 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north end of west wall |
| 1447 | MA-1447-OO-001-AV | 1000 / 0184 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south end of west wall |
| 1447 | MA-1447-01-003-AV | 1000 / 0185 | Low | Arrowhead | No.58 ABP | 3/4 | Slop sink with AV located in janitor's closet off break room |
| 1447 | MA-1447-01-004-AV | 1000 / 0186 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV under steel sink located on north wall |
| 1447 | MA-1447-01-005-DC | 1000 / 0188 | Low | Ames | 2000 SS | 6 | 6" DC on water supply line to fire suppression system located on east wall |
| 1447 | MA-1447-01-006-RP | 1000 / 0189 | High | Watts | 9 | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located on east wall |
| 1447 | MA-1447-01-007-RP | 1000 / 0190 | High | Watts | 909 MOD CW | 1 | 1" RP on make-up water supply line to steam boiler located in west area of mechanical room |
| 1448 | MA-1448-01-001-AV | 1000 / 0191 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of east wall |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1448 | MA-1448-01-004-DC | 1000 / 0647 | Low | Ames | Maxim 200 | 6" | 6" DC on fire suppression system located next to north walk-in entrance. |
| 1448 | MA-1448-01-002-RP | 1000 / 0192 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located in center of room adjacent to heat exchanger |
| 1448 | MA-1448-01-003-RP | 1000 / 0193 | High | Watts | 009 RP | 1 | 1" RP on main water supply line to washrack located approximately 12' high on center of south wall |
| 145 | MA-145-01-004-RP | 1000 / 763 | High | Watts | 009 RP | 3 | 3" RP Located in center of mechanical room on main water supply line for entire facility. |
| 145 | MA-145-01-003-RP | 1000 / 764 | High | Watts | 909M2QT | 2 | 2" RP for irrigation system. Located in center of mechanical room on Goddard side of building. |
| 145 | MA-145-01-002-AG | 1000 / 0194 | High | Potable water feed to chemical tank. | |||
| 145 | MA-145-01-001-RP | 1000 / 0195 | High | Watts | 909 | 3/4 | 3/4" RP on make up water supply line to Low Temperature Heating System |
| 1450 | MA-1450-01-011-AV | 1000 / 0198 | Low | Watts | 388a | 2 | 2" AV on 2" potable cold hose bib located on center of east wall approximately 15' high |
| 1450 | MA-1450-01-016-AV | 1000 / 0197 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV on main water supply located on east end of south wall |
| 1450 | MA-1450-01-012-AV | 1000 / 0204 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west wall |
| 1450 | MA-1450-01-010-AV | 1000 / 0196 | Low | Watts | 388a | 2 | 2" AV on 2" potable hot hose bib located on center of east wall approximately 15' high |
| 1450 | MA-1450-01-009-AV | 1000 / 0199 | Low | Watts | 388a | 2 | 2" AV on 2" potable cold hose bib located in southeast corner approximately 15' high |
| 1450 | MA-1450-01-002-AV | 1000 / 0206 | Low | Watts | 388a | 2 | 2" AV on 2" potable cold hose bib located on center of west wall approximately 15' high |
| 1450 | MA-1450-01-001-AV | 1000 / 0201 | Low | chicago | b641 | 3/4 | Slop sink with AV located in janitor's closet |
| 1450 | MA-1450-01-008-AV | 1000 / 0200 | Low | Watts | 388a | 2 | 2" AV on 2" potable hot hose bib located in southeast corner approximately 15' high |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1450 | MA-1450-01-003-AV | 1000 / 0205 | Low | Watts | 388a | 2 | 2" AV on 2" potable hot hose bib located on center of west wall approximately 15' high |
| 1450 | MA-1450-01-004-AV | 1000 / 0203 | Low | Chicago | b641 | 3/4 | Slop sink with AV located on west side of main bay inside small building |
| 1450 | MA-1450-01-006-AV | 1000 / 0207 | Low | Watts | 388a | 2 | 2" AV on 2" potable cold hose bib located on southwest end approximately 15' high |
| 1450 | MA-1450-01-005-AV | 1000 / 0202 | Low | Watts | 388a | 2 | 2" AV on 2" potable hot hose bib located on southwest end approximately 15' high |
| 1450 | MA-1450-01-015-PV | 1000 / 0208 | Low | Watts | 800 M4 QT | 2 | 2" PV on water supply line to potable hot water heater located on west side of heater |
| 1450 | MA-1450-01-014-RP | 1000 / 0211 | High | Watts | MOD QT RPZ | 3/4 | 3/4" RP on make-up water supply line to GHS/GHR system located west end of north wall |
| 1450 | MA-1450-01-007-RP | 1000 / 0209 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on water supply line to aqueous parts washer located in southeast corner |
| 1450 | MA-1450-01-013-RP | 1000 / 0210 | High | Watts | 909 MOD CW | 1 | 1" RP on make-up water supply line to Low Temperature Heating System located on south end of east wall |
| 1459 | MA-1459-01-001-AV | 1000 / 0212 | Low | Nidel | 34 HD | 3/4 | Hose bibb with AV on main water supply located in northwest corner |
| 1459 | MA-1459-OO-002-RP | 1000 / 0214 | Low | Watts | 909 M1 | 10 | 10" RP on main water supply line to fire pump house located northwest of building. 1 of 2 devices in parallel, west device |
| 1459 | MA-1459-OO-003-RP | 1000 / 0213 | Low | Watts | 909 M1 | 10 | 10" RP on main water supply line to fire pump house located northwest of building. 1 of 2 devices in parallel, east device |
| 1460 | MA-1460-01-002-AV | 1000 / 0216 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located at end of hallway, west of center of main bay |
| 1460 | MA-1460-01-003-AV | 1000 / 0217 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located in middle of bay and east of center |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1460 | MA-1460-01-004-AV | 1000 / 0218 | Low | T&S | b969 | 3/4 | Slop sink with AV in janitor's closet located east of center of bay |
| 1460 | MA-1460-01-006-AV | 1000 / 0219 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV on water supply line to domestic hot water heater located on south end of room |
| 1460 | MA-1460-01-001-AV | 1000 / 0215 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of west wall near entrance |
| 1460 | MA-1460-01-008-DC | 1000 / 0220 | High | Hersey | No. 2 | 8 | 8" DC on water supply line to AFFF fire suppression system located on east wall |
| 1460 | MA-1460-01-009-OT | 1000 / 0599 | High | Watts | 9D | 3/4 | 3/4" BPD with atmospheric vent on make-up water supply line to Low Temperature Heating System located approximately 15' high in |
| 1460 | MA-1460-01-007-OT | 1000 / 0222 | Low | Watts | 9D | 3/4 | 3/4" BPD with atmospheric vent on water supply line to humidifier located near ceiling above south end of boiler |
| 1460 | MA-1460-01-010-OT | 1000 / 0221 | Low | Watts | 9D | 3/4 | 3/4" BPD with atmospheric vent on water supply line to humidifier located approximately 15' high in southwest corner |
| 1460 | MA-1460-01-005-RP | 1000 / 0224 | High | Watts | 909 MOD CW | 1 | 1" RP on make-up water supply line to steam boiler and condensate return located in center of room adjacent to boiler |
| 1463 | MA-1463-01-002-AV | 1000 / 0225 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of west wall |
| 1463 | MA-1463-01-001-RP | 1000 / 0226 | High | Watts | 909 MOD | 3 | 3" RP on main water supply line to building located on south end of west wall |
| 1464 | MA-1464-01-001-AV | 1000 / 0227 | Low | nidel | 34 hd | 3/4 | Hose bibb with AV located in northwest corner |
| 1464 | MA-1464-01-002-AV | 1000 / 0228 | Low | chicago | b641 | 3/4 | Slop sink with AV in janitor's closet |
| 1464 | MA-1464-01-006-AV | 1000 / 0229 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of south wall |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1464 | MA-1464-02-005-AV | 1000 / 0230 | Low | Watts | 344 a | 1.5 | 1.5" AV on water supply line to hot potable water heater located approximately 15' high on west wall |
| 1464 | MA-1464-02-003-RP | 1000 / 0231 | High | Watts | 909 | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located on east wall (north RP) |
| 1464 | MA-1464-02-004-RP | 1000 / 0232 | High | Watts | Illegible | 3/4 | 3/4" RP on make-up water supply line to the GHS/GHR heating system located on east wall (south RP) |
| 1465 | MA-1465-OO-001-AV | 1000 / 0236 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of north wall |
| 1465 | MA-1465-OO-002-AV | 1000 / 0235 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east end of north wall |
| 1465 | MA-1465-OO-003-AV | 1000 / 0234 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of south wall |
| 1465 | MA-1465-01-005-AV | 1000 / 0237 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of east wall |
| 1465 | MA-1465-01-004-AV | 1000 / 0233 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east end of north wall |
| 1465 | MA-1465-01-006-AV | 1000 / 0238 | Low | chicago | B641 | 3/4 | Slop sink with AV in janitor's closet |
| 1465 | MA-1465-01-007-DC | 1000 / 0239 | Low | Ames | 2000 SS | 4 | 4" DC on water supply line to fire suppression system located on south wall |
| 1466 | MA-1466-OO-001-AV | 1000 / 0240 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east end of north wall |
| 1466 | MA-1466-OO-002-AV | 1000 / 0243 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on center of east wall |
| 1466 | MA-1466-01-003-AV | 1000 / 0241 | Low | chicago | B641 | 3/4 | Slop sink with AV located in southeast corner |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1466 | MA-1466-OO-007-AV | 1000 / 0242 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of south wall |
| 1466 | MA-1466-01-004-DC | 1000 / 0244 | Low | Ames | 2000 SS | 4 | 4" DC on water supply line to fire suppression system located in southwest corner |
| 1466 | MA-1466-01-005-PV | 1000 / 0245 | High | Watts | 800M4 | 1.5 | 1.5" PV on water supply line to irrigation located approximately 15' high on east wall above domestic hot water heater |
| 1466 | MA-1466-01-006-RP | 1000 / 0246 | High | Watts | 909 MOD CW | 1 | 1" RP on make-up water supply line to Low Temperature Heating System located approximately 10' high on east wall |
| 1467 | MA-1467-01-001-RP | 1000 / 0247 | Low | Ames | 4000 SS | 4 | 4" RP on water supply line to fire suppression system located in northwest corner |
| 1467 | MA-1467-01-002-RP | 1000 / 0248 | High | Watts | 909 MOD CW | 2 | 2" RP on main water supply line to washrack located approximately 10' high on the west end |
| 1469 | MA-1469-01-003-AV | 1000 / 0252 | Low | T&S | B969 | 3/4 | Slop sink with AV located in locker room |
| 1469 | MA-1469-01-004-AV | 1000 / 0251 | Low | T&S | B969 | 3/4 | Slop sink with AV located in janitor's closet |
| 1469 | MA-1469-OO-002-AV | 1000 / 0249 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west wall |
| 1469 | MA-1469-OO-005-AV | 1000 / 0250 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east wall |
| 1469 | MA-1469-OO-001-PV | 1000 / 0253 | High | Wilkins | 720 A | 1 | 1" PV on water supply line to irrigation located on northwest corner |
| 1469 | MA-1469-01-006-RP | 1000 / 0254 | High | Watts | 909 MOD CW | 3/4 | 3/4" RP on make-up water supply line Low Temperature Heating System located in northwest corner |
| 1482 | MA-1482-01-001-RP | 1000 / 0255 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located approximately 10' high on west end |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 152 | MA-152-OO-001-AV | 1000 / 0256 | Low | Watts | NF 8 | 3/4 | Hand hydrant with AV located southeast of building |
| 1535 | MA-1535-01-001-DC | 1000 / 0257 | Low | Ames | 2000 SS | 6 | 6" DC on water supply line to fire suppression system located on east side of building |
| 1590 | MA-1590-OO-001-PV | 1000 / 0258 | High | Watts | 800 M4 | 1.5 | 1.5" PV on water supply line to irrigation located at the T intersection of Aspen and Cedar |
| 160 | MA-160-OO-004-AV | 1000 / 0259 | Low | Watts | NF 8 | 3/4 | Hand hydrant with AV located south of building in center of lawn |
| 160 | MA-160-OO-001-AV | 1000 / 0260 | Low | Watts | NF 8 | 3/4 | Hand hydrant with AV located north of building in grassy area |
| 160 | MA-160-01-002-RP | 1000 / 0261 | High | Watts | 909 QT | 3/4 | 3/4" RP on make-up water to boiler and Low Temperature Heating System located in center of room just above boiler |
| 160 | MA-160-01-003-RP | 1000 / 0262 | High | Watts | 909MODCW | 3/4 | 3/4" RP on make-up water to Low Temperature Heating System located on north side of room and east of heat exchanger |
| 1600 | MA-1600-01-006-AV | 1000 / 0266 | Low | Watts | 388A | 3/4 | 3/4" AV on water supply line to dishwasher located on top of machine on north wall |
| 1600 | MA-1600-01-005-AV | 1000 / 0265 | Low | Watts | 288A | 1/2 | 1/2" AV on water supply line to dishwasher machine located on top of machine on north wall |
| 1600 | MA-1600-OO-002-AV | 1000 / 0267 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on south end of east wall |
| 1600 | MA-1600-01-004-AV | 1000 / 0264 | Low | Watts | 188A | 1/4 | 1/4" AV on water supply line to soap dispenser located on dishwasher on east end of north wall |
| 1600 | MA-1600-01-003-AV | 1000 / 0263 | Low | chicago | B641 | 3/4 | Slop sink with AV |
| 1600 | MA-1600-BM-001-RP | 1000 / 0268 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located in center of room on west end |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1620 | MA-1620-OO-001-AV | 1000 / 0273 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of north wall |
| 1620 | MA-1620-OO-007-AV | 1000 / 0272 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west end of south wall |
| 1620 | MA-1620-OO-008-AV | 1000 / 0271 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east end of south wall |
| 1620 | MA-1620-OO-002-AV | 1000 / 0274 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east end of north wall |
| 1620 | MA-1620-02-004-AV | 1000 / 0269 | Low | chicago | B641 | 3/4 | Slop sink with AV located in janitor's closet |
| 1620 | MA-1620-01-003-AV | 1000 / 0270 | Low | chicago | b641 | 3/4 | Slop sink with AV located in janitor's closet |
| 1620 | MA-1620-BM-006-RP | 1000 / 0276 | High | Watts | 909QT | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located in center of room |
| 1620 | MA-1620-BM-005-RP | 1000 / 0275 | High | Wilkins Zurn | 975 XL | 1.5 | 1.5" RP on water supply line to irrigation located in southeast corner |
| 165 | MA-165-OO-004-AV | 1000 / 0279 | Low | Watts | NF 8 | 3/4 | Hand hydrant located north of building in grassy area |
| 165 | MA-165-01-001-AV | 1000 / 0278 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north end of west wall |
| 165 | MA-165-01-003-AV | 1000 / 0277 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on north end of east wall |
| 165 | MA-165-01-006-OT | 1000 / 0280 | High | Watts | 9D | 3/4 | 3/4" non-testable DC on water supply line to chemical feed tank located on north end of east wall |
| 165 | MA-165-01-002-OT | 1000 / 0281 | High | Watts | No. 7 702-2 | 3/4 | 3/4" non-testable DC on water supply to hose bibb used to make-up water to chiller |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 165 | MA-165-01-005-RP | 1000 / 0282 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on make-up water supply line to boiler located on east end of north wall |
| 1680 | MA-1680-OO-002-AV | 1000 / 0284 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of east wall |
| 1680 | MA-1680-OO-003-AV | 1000 / 0285 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on west wall |
| 1680 | MA-1680-OO-004-AV | 1000 / 0286 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on north wall |
| 1680 | MA-1680-BM-005-DC | 1000 / 0648 | Low | Ames | Maxim 200 | 4 | 4" DC on fire suppression system located in lower mechanical room on south side of building. |
| 1680 | MA-1680-OO-001-AV | 1000 / 0283 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of south wall |
| 1681 | MA-1681-OO-005-AV | 1000 / 0289 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of south wall |
| 1681 | MA-1681-01-002-AV | 1000 / 0287 | Low | chicago | B969 | 3/4 | Slop sink with AV |
| 1681 | MA-1681-OO-003-AV | 1000 / 0291 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of north wall |
| 1681 | MA-1681-OO-006-AV | 1000 / 0288 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of west wall |
| 1681 | MA-1681-OO-004-AV | 1000 / 0290 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of east wall |
| 1681 | MA-1681-01-007-RP | 1000 / 0293 | High | Wilkins Zurn | 975 XL | 2 | 2" RP on water supply line to irrigation located on east wall |
| 1681 | MA-1681-01-001-RP | 1000 / 0292 | Low | Febco | 825 Y | 1.5 | 1.5" RP on water supply line to fire suppression system located on north end of building |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1682 | MA-1682-01-002-AV | 1000 / 0295 | Low | T&S | B969 | 3/4 | Slop sink with AV |
| 1682 | MA-1682-OO-003-AV | 1000 / 0296 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of east wall |
| 1682 | MA-1682-OO-004-AV | 1000 / 0298 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of south wall |
| 1682 | MA-1682-OO-005-AV | 1000 / 0297 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of west wall |
| 1682 | MA-1682-OO-006-AV | 1000 / 0294 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of north wall |
| 1682 | MA-1682-01-001-RP | 1000 / 0299 | Low | Febco | 825 Y | 1.25 | 1.25" RP on water supply line to fire suppression system located on east end of building |
| 1683 | MA-1683-01-002-AV | 1000 / 0304 | Low | T&S | B969 | 3/4 | Slop sink with AV |
| 1683 | MA-1683-OO-006-AV | 1000 / 0301 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of west wall |
| 1683 | MA-1683-OO-005-AV | 1000 / 0300 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of south wall |
| 1683 | MA-1683-OO-003-AV | 1000 / 0303 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of north wall |
| 1683 | MA-1683-OO-004-AV | 1000 / 0302 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on center of east wall |
| 1683 | MA-1683-01-001-RP | 1000 / 0306 | Low | Febco | 825 Y | 1.25 | 1.25" RP on water supply line to fire suppression system located on north end of building |
| 1683 | MA-1683-01-007-RP | 1000 / 0305 | High | Wilkins Zurn | 975 XL | 2 | 2" RP on water supply line to irrigation located on east wall (IRRIGATION) |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1684 | MA-1684-OO-001-AV | 1000 / 0308 | Low | Zurn | Z-1321 | 3/4 | Hose bibb with AV located on south wall |
| 1684 | MA-1684-01-003-AV | 1000 / 0307 | Low | T&S | 3/4 | Slop sink with AV in janitor's closet | |
| 1684 | MA-1684-01-002-RP | 1000 / 0310 | Low | Ames | 2000 SS | 3 | 3" RP on water supply line to fire suppression system located near east wall |
| 1684 | MA-1684-01-004-RP | 1000 / 0309 | High | Watts | 909 M1 QT | 2 | 2" RP on main water supply line to the building located in northeast corner |
| 1702 | MA-1702-01-001-AV | 1000 / 0313 | Low | T&S | B969 | 1/2 | Slop sink with AV in janitor's closet |
| 1705 | MA-1705-01-001-RP | 1000 / 0315 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on make-up water supply line to boiler located in northeast corner |
| 1708 | MA-1708-01-001-RP | 1000 / 603 | HIGH | Watts | 909 MOD CW | 3/4 | 3/4" RP on make up water supply line to low temp heating system--- located west of heat exchanger in center of room. |
| 1835 | MA-1835-01-001-RP | 1000 / 605 | HIGH | Wilkens Zurn | 975 xl | 3/4 | Upper Device --- 3/4" RP on water supply line to heating system --- Located along West wall in Mechanical room next to water heater. |
| 1835 | MA-1835-01-002-RP | 1000 / 606 | HIGH | Wilkens Zurn | 975 xl | 3/4 | Lower Device --- 3/4" RP on water supply line to heating system --- Located along west wall in mechanical room next to water heater. |
| 1840 | MA-1840-01-001-RP | 1000 / 0316 | HIGH | Watts | 909 MODQT | 2 | 2" RP on make-up water supply line to low temp heating system --- Located in #2 Equip Room along east wall next to transformer. |
| 1840 | MA-1840-01-002-RP | 1000 / 607 | HIGH | Watts | 909 MODQT | 3/4 | 3/4" RP on make-up water supply line --- Located above boiler in center of Equipment Room #3. |
| 1844 | MA-1844-01-001-DC | 1000 / 0781 | High | Watts | 007M1QT | 1" | 1" DC located on North Wall of Mechanical Room |
| 1845 | MA-1845-01-001-RP | 1000 / 0782 | Low | Watts | 909 MODQT | 2" | 2" RP Located on fire system line in fire mechainical room on east wall. |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 1867 | MA-1867-01-001-RP | 1000 / 608 | HIGH | Watts | 909 MODQT | 3/4 | REMOVED |
| 1869 | MA-1869-01-001-RP | 1000 / 0317 | High | Watts | 909 MODQT | 3/4 | 3/4" RP on water supply line to heating system --- Located on North wall in Mechanical room. |
| 1879 | MA-1879-01-001-RP | 1000 / 0318 | High | Watts | 909 MOD QT | 3/4 | 3/4" RP on make-up water supply line to boiler located in southwest corner |
| 1890 | MA-1890-01-001-DC | 1000/0783 | LOW | AMES | 2000 SS | 8" | 8" Double check on Fire Suppression System located in fire protection room in nw corner of bldg. |
| 192 | MA-192-01-001-AV | 1000 / 0319 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located in southwest corner |
| 192 | MA-192-01-002-AV | 1000 / 0320 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west wall |
| 192 | MA-192-OO-003-AV | 1000 / 0321 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on west wall |
| 192 | MA-192-OO-004-PV | 1000 / 0322 | High | Wilkins | 720A | 1.5 | 1.5" PV on water supply line to irrigation located on west end of south wall |
| 1996 | MA-1996-BM-001-RP | 1000 / 0323 | High | Watts | 909 MOD CW | 3/4 | 3/4" RP on main water supply line to building located on south end of west wall |
| 200 | MA-200-01-001-AV | 1000 / 0324 | Low | Arrowhead | No.58 ABP | 3/4 | Hose bibb with AV located on east wall just north of battery shops |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 219 | MA-219-01-006-AV | 1000 / 0354 | Low | chicago | B641 | 3/4 | Slop sink with AV located on east wall |
| 219 | MA-219-01-007-AV | 1000 / 0355 | Low | Watts | 288a | 3/4 | Hose reel with AV located on east wall |
| 219 | MA-219-01-005-AV | 1000 / 0353 | Low | Watts | 288a | 3/4 | Hose reel with AV located on west wall |
| 219 | MA-219-01-004-AV | 1000 / 0356 | Low | Watts | 288a | 3/4 | Hose reel with AV located on east wall |
| 219 | MA-219-01-003-AV | 1000 / 0352 | Low | chicago | b641 | 3/4 | Slop sink with AV located in janitor's closet |
| 219 | MA-219-01-002-RP | 1000 / 0358 | Low | Hersey | 6C-M | 6 | Removed under Project Nzas-200007. (April, 2005) |
| 219 | MA-219-01-008-RP | 1000 / 800 | High | Wilkens / Zurn | 975 XL | 1" | 1" RP located next to W/H on mezzinine in mechanical room. |
| 219 | MA-219-01-001-DC | 1000 / 0357 | Low | Ames | Maxim 200 | 6 | 6" DC on water supply line to fire suppression system located in Security Forces hangar behind offices. |
| 220 | MA-220-01-006-DC | 1000 / 0634 | Low | Ames | Maxim 200 | 4" | 4" RP on water supply line to fire suppression system located in tool room on Utility Shop Side of building. |
| 220 | MA-220-02-004-AV | 1000 / 0360 | Low | Watts | 288a | 3/4 | Hose bibb with AV located on north wall |
| 220 | MA-220-OO-002-AV | 1000 / 0361 | Low | Nidel | 34a | 3/4 | Hose bibb with AV located on east end of north wall |
| 220 | MA-220-01-003-AV | 1000 / 0359 | Low | T&S | B969 | 3/4 | Slop sink with AV located in janitor's closet |
| 220 | MA-220-01-005-OT | 1000 / 0362 | High | Watts | 9D | 3/4 | 3/4" non-testable backflow preventer on make-up water supply line to Low Temperature Heating System located approximately 10' h |
| 220 | MA-220-01-007-RP | 1000/0825 | High | Watts | 909M1QT | 2" | 2' RP on water supply line to fill stand and backflow system trainers. Located in Tool room along north wall on WFSM side of bldg. |
| 220 | MA-220-OO-001-PV | 1000 / 0363 | High | Watts | 800M4 | 1 | 1" PV on water supply line to irrigation located southeast of building and west of side parking lot |
| Building Number | BPD ID Full | RWP Equipment Type / Number | Hazard Rank | Manufacturer | Model | Size | Point of Use |
| 226 | MA-226-01-001-DC | 1000 / 0780 | Low | Ames | Maxim 200 | 6" | 6" DC on fire suppression system located on Utility Shop side of building along west wall. |
| 250 | MA-250-BM-001-AV | 1000 / 0364 | High | Nidel | 34 hd | 3/4 | Hose bibb with AV located on east wall used to manually make up water to chiller |
| 250 | MA-250-BM-002-DC | 1000 / 0367 | Low | Ames | Maxim 200 | 4 | 4" DC on water supply line to fire suppression system located on center of north wall |
| 250 | MA-250-BM-005-DC | 1000 / 0365 | High | Watts | 009M2QT RP | 2 | 2" DC on water supply line to irrigation located approximately 14' high in center of north side of room |
| 250 | MA-250-BM-004-RP | 1000 / 0366 | High | Watts | 909 OT RP2 | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located approximately 3' high on south side of room |
| 250 | MA-250-BM-003-RP | 1000 / 0368 | High | Watts | 909 OT RP2 | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located near center wall next to stairs |
| 295 | MA-295-01-002-AV | 1000 / 0369 | Low | T&S | b969 | 3/4 | Slop sink with AV located in laundry room |
| 295 | MA-295-01-001-RP | 1000 / 0370 | High | Watts | 909MODQT | 3/4 | 3/4" RP on make-up water supply line to Low Temperature Heating System located in center of room |