Appendix A.pdf

PDF 3 MB Posted

Attached to
Procure and Replace Log Boom at North Hartland Lake, North Hartland, VT
Solicitation number
W912WJ25Q0007
Issued by

About this file

This document is an appendix containing maps and informational photos related to a federal contract opportunity for the procurement and replacement of a log boom at North Hartland Lake in Vermont. The key details are:

The solicitation is for the U.S. Army Corps of Engineers - New England District to procure and replace a log boom at North Hartland Lake. The work includes furnishing labor, materials, and equipment to replace approximately 2,300 feet of 1-inch diameter galvanized wire rope, 20 twenty-foot long boom logs, 40 log boom chains, 12 one-inch rope clamps, and 2 one-inch thimbles. The contractor shall also remove and properly dispose of the existing deteriorated equipment. The Government may exercise an option to purchase 5 additional twenty-foot long boom logs. The magnitude of the construction is between $100,000 and $250,000, and the procurement is set-aside for small business vendors under NAICS code 238990 with a size standard of $19 million. All vendors must have an active SAM.gov registration to be considered.

View the file

Other files

File Type Posted
Solicitation W912WJ25Q0007.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX A

Maps and Informational Photos

Photo 1: “Right Bank” log boom connection- Pile Anchor at North Hartland Lake

Photo 2: “Left Bank” log boom connection- Eye Bolt Anchor at North Hartland Lake

Photo 3: Drawing oriented looking downstream. Left bank is located on the far side of the project across the lake from the project office and right bank is in the recreation area.

*Wire Rope has been scaled up to 1” from this original drawing; Two additional clamps per anchor have been located at each location

Photo 4: Technical drawing of log boom to log connection.

*Wire Rope has been scaled up to 1” from this original drawing

Photo 5: Logs overlap slightly when on land, and Cable should be tightened to Project Manager’s specification.

Photo 6: Elevation profile of the Log Boom

Photo 7: typical log boom connection between two logs with one deteriorated log in need of replacement

Photo 8: View from West Pile anchor down the boom. Another example of deteriorated log in need of replacement

Photo 9: Logs should overlap slightly when floating in the lake to ensure no gaps between

Photo 10: Connecting chains: 5” Hot-dip Galvanized carbon steel 1/2” diameter steel ring of 3- 1/2” inside diameter on the end of 1 ½” x 5’ 6” chains, with a 1/2” x 1 ½” x 6” toggle on the end

Photo 11: Detail of ring on end of chain

File details come from the government source that posted it. Updated .