This is a Statement of Work (SOW) Appendix for a drinking fountain installation project at Franklin Falls Dam in Franklin, New Hampshire, managed by the U.S. Army Corps of Engineers. The appendix provides informational maps, photographs, and technical drawings to support the main SOW document.

The project requires installation of a government-furnished drinking fountain and construction of a new ADA-compliant walkway on the east side of an existing restroom building. According to Informational Drawing 5, the fountain pad is approximately 7 feet 4 inches from the existing building, with the new walkway extending 13 feet from the building to connect to the existing walkway. The fountain installation must avoid blocking an existing vent on the east side of the restroom building. Water service will be extended from the existing supply line that currently terminates near the sink trap inside the eastern restroom; the main water shut-off valve is located in the basement of the Activity Center building. The site consists of two restroom facilities (eastern and western chambers) within a ROMTEC modular building structure. Informational photographs and technical drawings detail the existing building configuration, interior plumbing infrastructure, foundation details, and the precise location where the fountain and walkway must be installed relative to existing site features and utilities.

View the file

Other files

File Type Posted
Solicitation Survey 26QA142.pdf PDF
Amendment W912WJ26QA142-0002.pdf PDF
Amendment W912WJ26QA142-0001.pdf PDF
Appendix B_26QA142.pdf PDF
Solicitation W912WJ26QA142.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRINKING FOUNTAIN INSTALLATION

U.S. ARMY CORPS OF ENGINEERS

FRANKLIN FALLS DAM

FRANKLIN, NH

STATEMENT OF WORK

APPENDIX A

See Attached

Informational Map

Informational Photos

Informational Drawings

Informational Map 1: General overview of the location with the yellow square in the bottom left corner showing the approximate location of work area for drinking fountain and ADA walkway installation.

Informational Map 2: Closer map overview of the location with the red rectangles showing the approximate location of the ADA walkway installation and the yellow circle showing the approximate location of the drinking fountain installation.

Informational Photo 1: Existing main approach walkway and front concrete apron with the two access doors to the restroom building facing North.

Informational Photo 2: East side of the restroom building with arrow pointing towards the vent that shall not be blocked. This is the side of building where the drinking fountain and walkway shall be installed.

Informational Photo 3: Termination of the existing walkway facing towards the East side of the restroom building.

Informational Photo 4: Inside the Eastern restroom and facing the East side of the restroom.

The existing water supply is the white pipe shown along the floor and terminating near the sink trap.

Informational Photo 5: Inside the Eastern restroom and facing the North side of the restroom.

The existing water supply is the white pipe shown along the floor and extending through the wall behind the toilet.

Informational Photo 6: Inside the Western restroom and facing the North side of the restroom.

The existing water supply is the white pipe shown along the floor and extending from the right-side wall behind the toilet.

Informational Photo 7: Inside the Western restroom and facing the West side of the restroom.

The existing water supply is the white pipe entering the building through the floor and is shown along the floor and running towards the North.

Informational Photo 8: Main water supply shut off for the restroom building located in the basement of the Activity Center building.

Informational Drawing 1: General Floor Plan for ROMTEC Restroom building.

Informational Drawing 2: Exterior Elevations for ROMTEC Restroom building.

Informational Drawing 3: Building Section Plan for ROMTEC Restroom building.

Informational Drawing 4: Foundation Details for ROMTEC Restroom building.

Informational Drawing 5: General Site Layout and Orientation with Approximate Dimensions for ADA Fountain Pad and Walkway.

File details come from the government source that posted it. Updated .