Angell Dining Hall Rehab Drawings.pdf
PDF 5 MB Posted
- Attached to
- Angell Job Corps Center Dining Hall Rehab
- Solicitation number
- 1282A722R0015
- Issued by
-
Department of Agriculture Forest Service
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1282A722R0015 Amended Solicitation.pdf | ||
| 1282A722R0015 Amendment.pdf | ||
| Angell Dining Hall Rehab SOW.pdf | ||
| Solicitation 1282A722R0015.pdf | ||
| Davis-Bacon Act WD OR20220041.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ANGELL JOB CORPS CENTER
B1401 DINING HALL – MISCELLANEOUS REHAB
MAY 2022
VICINITY MAP, SITE MAP, BUILDING FLOORPLANS & PHOTOS
YACHATS, OREGON
ANGELL CCC
ANGELL
CIVILIAN CONSERVATION CENTER
20 MI100
cjpence Callout Project Location
DN UP
UP
40'20'10'0
BUILDING 1401
YACHATS, OREGON
ANGELL CCC
DINING HALL & CULINARY ARTS
BASEMENT
VOCATION/THEORY
AutoCAD SHX Text
CLASSROOM/
AutoCAD SHX Text
DINING
AutoCAD SHX Text B01
AutoCAD SHX Text
CULINARY
AutoCAD SHX Text
ARTS
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text B02
AutoCAD SHX Text
HALL
AutoCAD SHX Text B06
AutoCAD SHX Text
MECH.
AutoCAD SHX Text B05
AutoCAD SHX Text
SCULLERY
AutoCAD SHX Text B04
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text B07A
AutoCAD SHX Text
JAN
AutoCAD SHX Text B11
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
EQUIP.
AutoCAD SHX Text B10
AutoCAD SHX Text
HALL
AutoCAD SHX Text B08
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text B09
AutoCAD SHX Text
ELEC.
AutoCAD SHX Text B13
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text B03
AutoCAD SHX Text
TOILET
AutoCAD SHX Text B12
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text B07B cjpence Oval cjpence Oval cjpence Callout Remove and replace two gas-fired domestic water heaters (WH-1 & WH-2). Reuse existing (new) expansion tank.
Remove drain pan assemblies, and install new galvanized steel or aluminum drain pan assemblies. Plumb pan drains to the adjacent floor drain.
Reuse existing seismic strapping.
cjpence Line cjpence Callout WH-1 & WH-2 intakes and exhausts terminate through block wall using concentric termination kits. Reuse existing 3" PVC intake and exhaust piping to the extent that is practical.
DN
UP
UP
DN
40'20'10'0
BUILDING 1401
YACHATS, OREGON
ANGELL CCC
DINING HALL & CULINARY ARTS
UPPER LEVEL
FOOD SERVICE
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
DINING
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text B09
AutoCAD SHX Text
DATA /
AutoCAD SHX Text
TELE
AutoCAD SHX Text
AutoCAD SHX Text
STUDENT
AutoCAD SHX Text
SERVING
AutoCAD SHX Text 116B
AutoCAD SHX Text
RECEIVING
AutoCAD SHX Text
AutoCAD SHX Text
LOADING
AutoCAD SHX Text
DOCK
AutoCAD SHX Text
AutoCAD SHX Text
HALL
AutoCAD SHX Text
AutoCAD SHX Text
SCULLERY
AutoCAD SHX Text
AutoCAD SHX Text
FOOD
AutoCAD SHX Text
PREP.
AutoCAD SHX Text
AutoCAD SHX Text
GRILLE
AutoCAD SHX Text
LINE
AutoCAD SHX Text 116A
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
AutoCAD SHX Text
DRY
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
FREEZER
AutoCAD SHX Text
AutoCAD SHX Text
COOLER
AutoCAD SHX Text cjpence Rectangle cjpence Rectangle cjpence Rectangle cjpence Rectangle cjpence Callout Remove existing R-22 evaporator units (E-1 and E-2) and line sets, and replace with new low-profile evaporator units and line sets.
cjpence Line cjpence Callout Remove and replace existing condensing unit (C-1), located above walk-in freezer. Replace disconnect.
cjpence Callout Remove and replace existing condensing unit (C-2), located above walk-in cooler. Replace disconnect.
cjpence Rectangle cjpence Callout Electrical Panel "C1"
Replace breakers as necessary to comply with new equipment manufacturer's maximum overcurrent protection recommendations.
Angell JC – B1401 Dining Hall - Miscellaneous Rehab
Photos
Photo 1 - Walk-In Freezer
Photo 2 - Walk-In Freezer Evaporator Unit
Photo 3 - Walk-In Cooler
Photo 4 - Walk-In Cooler Evaporator Unit
Photo 5 - Panel C1 Circuit Directory
Photo 6 - Panel C1
Photo 7 - WH-2 (left), and WH-1 (right)
Photo 8 - Existing concentric vent terminations, interior, reuse
Photo 9 - Existing concentric vent terminations, exterior, reuse
| Sheets and Views |
| basement (2) |
| B1401floorPlan1stV3.pdf |
| Sheets and Views |
| UPPER FLOOR |
| B1401floorPlan1stFlr.pdf |
| Sheets and Views |
| UPPER FLOOR |
| Attachment01_VicinitySiteMaps.pdf |
| BldgFloorPlanV2.pdf |
| Sheets and Views |
| LAYOUT |
| BldgFloorPlanV2.pdf |
| Sheets and Views |
| LAYOUT |
File details come from the government source that posted it. Updated .