AG-4D90-S-17-0070

Site Showing Q&A

Question 1:

Please confirm: Concrete stem walls to be sawcut about 6" away from head house, then capped with flashing, flashing tucked underneath siding

Concrete stem walls to be sawcut as close to head house as possible, but 2-6” extension from wall is fine, then capped with flashing.

Question 2:

Please confirm: Greenhouse to be moved eastward to avoid relocating natural gas service, it will not be centered on the head house

Yes

Question 3:

Please confirm: Breezeway space between greenhouse and headhouse to be approx. 4'-6"

Yes, breezeway clearance between protruding stem wall caps on headhouse and greenhouse needs to be at least 4’6” wide to accommodate 4’ door on headhouse and cart traffic.

Question 4:

Please confirm: No plumbing. No electrical or lighting to the greenhouse (except power for the fan and furnace, via conduit overhead breezeway)

Install plumbing from headhouse for one spigot on north end of greenhouse. Electrical wiring for installation of gas furnace and exhaust fan.

Question 5:

What foundations (none, at each post, or strip) are required for the greenhouse?

Concrete post footings should be installed as specified by greenhouse kit manufacturer.

Question 6:

Please confirm: It appears that the Lump Sum pricing breakdown sheet suggests we are providing the Greenhouse Kit, statement of work suggests greenhouse kit materials and benches would be provided USDA

With amended (combined) solicitation, contractors should provide quotes on the greenhouse kit and greenhouse benches, as well as demolition and installation.

Question 7:

Greenhouse mfg questions: There isn't a 14 year poly product - T4 is a 4 year product. Quonset shape doesn't accommodate a 6' vertical roll up wall, it would roll on to the roof.

The polyfilm should be clear 6mil (4 year). Ok to go with semi-gable type greenhouse construction with 4’ roll-up side walls (providing approximately 6’ clearance at side wall).

Amendment 0002

File details come from the government source that posted it. Updated .