Text version
17710 Frances Street, Omaha NE, 68130
Office (402) 964.2400 Mobile (402) 660.8279
1945 North 38th Street Lincoln NE 2016 For ThermaScan Solutions Report
10/24/2016
Parameters and information on how to understand this report otherwise classified as “Notes”.
The parameters that are used to determine and arrive at the conclusion of this report is based on historical data, education, training, and years of experience, and will consist of the following but not limited to the infrared images also, visual observations of the conditions with water standing and running in the parking lots for these buildings. All determining factors are based on a professional understanding of Thermography, Logic, Physics, and Thermal Dynamics of the materials and their thermal capacitance.
• Markings on the infrared images and photos.
• “R” refers to Reference point (#1 on the data section), what the temperature should read.
• #2 through #10 refers to the points of the image and area that are of concern or also known as Regions of Interest (ROI’s).
• “Poly” is a section that is drawn on the infrared image that is showing the area that is affected by the moisture in this report. It can also be considered as an area that has a water path or moisture track.
• “Delta” is the data differences between the reference point and the other points and callouts, which mean temperature, change from the reference point that is quantified with the reference point and callouts in this report which then are analyzed base on the physical properties of water, dirt, & asphalt to arrive at the information from the infrared images for the conclusion of the report for the issues that are of concern with this property.
• “Emiss” is based on physics and the materials physical properties (for analyzing images).
• “Avg” refers to the data that is collected within shapes overall temperature properties.
• “Min” refers to the Minimum temperature data that is collected at the points and within shapes that is drawn on the infrared image.
• “Max” refers to the Maximum temperature data that is collected at the points and within shapes that is drawn on the infrared image.
Arrows; The arrows that are placed on the digital images or photos are placed for several reasons some of which are but not limited to; a) indicators of direction of the area of concern,
b) approximate size of the area that is affected and inspected, c) the approximate shape of the affected area that was inspected, d) regions of interest or points, and markers for location purposes that correlate with the infrared images that are on the same report page.
Disclaimer: All information from the Infrared images reflect the point in time (date and time of images) of the inspection only, any prior of post data, information or concerns will not be available on this report.
Copy right laws apply on any changes, coping, selling, distribution, of this report without written permission and consent of ThermaScan Solutions LLC.
Other information consist of Visual and verbal information from customer
1. During the daytime survey we met with Richard Carman whom took me around the facility to gain access to the roof.
2. Mr. Carman returned to accompany me during the night time survey as well.
3. Mr. Carman also marked the roof with pink marking paint for the areas of concern while the live survey was in process. This may give about 12% to 15% of the information.
4. The roof surface appeared to be in very good condition visually, the covering on the roof was rock or ballast.
5. In the center section of the structure there was a small protective wall around the air handling systems.
6. Most of the air handling system units was located at the southern central section of the roof.
7. Some of the areas were marked with pink marking paint at the time of the night survey, these areas appear to be in question of possible moisture infiltration to the structure’s internal materials, framework and interior.
8. The areas that are called out in this report appear to have the potential of moisture tracking unless otherwise stated on each page.
Office (402) 964.2400, Mobile (402) 660.8279
THERMASCAN SOLUTIONS REPORT
Report Date: 10/24/2016
ThermaScan Solutions LLC LOCATION: Northeast roof section 17710 Frances Street EQUIPMENT ID:
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780001.SIT • 10/13/2016
• 7:25 PM
Ref Point Point 2 Point 3 Poly 4
Emiss. 0.98 0.98 0.98 0.98
Avg °F 52.6
Min °F 50.9
Max °F 48.1 51.7 54.1 56.7
Delta °F 3.6 6.0 8.6
PROBLEM "R" is the Reference point Point #2 & 3 appears to be an opening that may allow moisture to infiltrate the roofing insulation materials. The Poly section appears to be a moisture path
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property management or owner, unless ThermaScan Solutions is requested to do repairs
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780002.SIT • 10/13/2016
• 7:26 PM
Ref Point Point 2 Point 3 Point 4 Poly 5
Emiss. 0.98 0.98 0.98 0.98 0.98
Avg °F 48.7
Min °F 44.7
Max °F 45.8 52.8 50.7 50.7 51.6
Delta °F 7.0 4.9 4.9 5.8
PROBLEM "R" is the Reference point All callouts appear to be a concern of potential moisture infiltration, poly #5 appears to be a moisture path RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Omaha, Nebraska 68130 SEVERITY: Moderate to high
1945 North 38th Street Lincoln NE 2016 780003.SIT • 10/13/2016
• 7:27 PM
Avg °F 48.3
Min °F 44.6
Max °F 46.7 49.9 49.3 50.9
Delta °F 3.2 2.6 4.1
PROBLEM "R" is the Reference point All callouts appear to be a potential of an opening at point
#2 & 3, poly #4 appears to be a possible moisture path beneath the roofing materials
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: East side north central roof section
Omaha, Nebraska 68130 SEVERITY: Moderate to high
1945 North 38th Street Lincoln NE 2016 780004.SIT • 10/13/2016
Ref Point Point 2 Point 3
Emiss. 0.98 0.98 0.98
Avg °F
Min °F
Max °F 47.2 50.0 51.4
Delta °F 2.8 4.2
PROBLEM "R" is the Reference point All callouts appear to be a potential of having openings that may allow moisture to infiltrate the interior of the structure’s materials and or the interior of the structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780005.SIT • 10/13/2016
Ref Point Point 2 Point 3 Point 4 Point 5
Avg °F
Min °F
Max °F 47.8 58.0 56.8 56.6 52.0
Delta °F 10.2 9.0 8.7 4.2
PROBLEM "R" is the Reference point All callouts appear to have potential moisture within the roofing materials RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Northeast central roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780006.SIT • 10/13/2016
• 7:28 PM
Avg °F
Min °F
Max °F 46.9 51.1 50.6
Delta °F 4.2 3.7
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: North wall east roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780007.SIT • 10/13/2016
• 7:28 PM
Ref Point Point 2 Point 3 Point 4
Avg °F
Min °F
Max °F 49.2 54.2 52.9 53.4
Delta °F 4.9 3.6 4.2
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: North wall east roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780008.SIT • 10/13/2016
• 7:29 PM
Ref Point Point 2 Point 3 Poly 4 Poly 5
Avg °F 50.6 48.6
Min °F 47.5 45.7
Max °F 46.7 49.7 50.9 52.7 51.7
Delta °F 3.0 4.2 6.0 5.0
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Report Date: 10/28/2016
ThermaScan Solutions LLC LOCATION: North end central roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780009.SIT • 10/13/2016
• 7:37 PM
Avg °F 50.1
Min °F 44.6
Max °F 47.8 54.1 54.9 55.6
Delta °F 6.3 7.1 7.8
PROBLEM "R" is the Reference point All callouts appear to be a potential moisture point and path to the interior of the structure RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: North side south roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780010.SIT • 10/13/2016
• 7:38 PM
Ref Point Point 2 Point 3 Point 4 Poly 5
Avg °F 47.6
Min °F 42.2
Max °F 46.6 50.1 50.1 49.7 50.7
Delta °F 3.5 3.5 3.2 4.1
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: North side central roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780011.SIT • 10/13/2016
• 7:39 PM
Ref Point Point 2
Emiss. 0.98 0.98
Avg °F
Min °F
Max °F 48.2 53.3
Delta °F 5.1
PROBLEM "R" is the Reference point Point #2 appears to be a potential opening that may allow moisture to infiltrate the interior of the structure RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Northwest corner roof section
Omaha, Nebraska 68130 SEVERITY: Moderate to high
1945 North 38th Street Lincoln NE 2016 780012.SIT • 10/13/2016
• 7:39 PM
Ref Point Poly 2
Avg °F 47.2
Min °F 43.5
Max °F 46.7 49.5
Delta °F 2.9
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: West side southern roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780014.SIT • 10/13/2016
• 7:41 PM
Avg °F
Min °F
Max °F 46.7 50.8 49.7
Delta °F 4.1 3.0
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: West side central roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780015.SIT • 10/13/2016
• 7:44 PM
Ref Point Point 2 Point 3 Poly 4 Point 5 Point 6
Emiss. 0.98 0.98 0.98 0.98 0.98 0.98
Avg °F 49.3
Min °F 45.3
Max °F 45.2 50.4 51.1 52.1 54.1 48.9
Delta °F 5.2 5.9 6.9 8.9 3.7
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Southwest corner
Omaha, Nebraska 68130 SEVERITY: Questionable
1945 North 38th Street Lincoln NE 2016 780016.SIT • 10/13/2016
• 7:44 PM
Avg °F
Min °F
Max °F 46.5 49.7
Delta °F 3.2
PROBLEM "R" is the Reference point Point #2 appears to be a potential opening within the roofing materials although, there was some debris that appeared to be broken concrete on the top of the rock
RECOMMENDATION Have a roofer inspect and repair if necessary to prevent moisture infiltration into the roofing materials
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: West central roof section
Omaha, Nebraska 68130 SEVERITY: Questionable to none
1945 North 38th Street Lincoln NE 2016 780017.SIT • 10/13/2016
• 7:45 PM
Avg °F
Min °F
Max °F 47.0 48.3 48.9
Delta °F 1.3 1.9
PROBLEM "R" is the Reference point This area appeared to be dirt within the ballast RECOMMENDATION None
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: West central roof section
Omaha, Nebraska 68130 SEVERITY: Questionable to none
1945 North 38th Street Lincoln NE 2016 780018.SIT • 10/13/2016
• 7:46 PM
Ref Point Point 2 Point 3 Point 4 Point 5
Avg °F
Min °F
Max °F 46.0 49.2 49.0 48.6 49.5
Delta °F 3.2 3.0 2.6 3.5
PROBLEM "R" is the Reference point This area appeared to be dirt within the ballast
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: South central roof vent
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780019.SIT • 10/13/2016
• 7:48 PM
Avg °F
Min °F
Max °F 50.0 58.4
Delta °F 8.4
PROBLEM "R" is the Reference point Point #2 appears to be potential opening that may allow moisture to infiltrate the interior of the structure
RECOMMENDATION Have a roofer repair the that is called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Southwest central roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780021.SIT • 10/13/2016
• 7:51 PM
Ref Point Point 2 Poly 3
Avg °F 47.9
Min °F 43.7
Max °F 47.4 50.7 51.2
Delta °F 3.3 3.8 path to the interior of the structure, the poly #3 appears to be the area that maybe affected
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Southwest central roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780022.SIT • 10/13/2016
• 7:51 PM
Avg °F 47.8
Min °F 43.4
Max °F 47.0 50.4 51.2
Delta °F 3.4 4.2 path to the interior of the structure, the poly #3 appears to be the area that maybe affected
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Northwest roof vent inside wall
Omaha, Nebraska 68130 SEVERITY: Low to moderate
1945 North 38th Street Lincoln NE 2016 780023.SIT • 10/13/2016
• 7:53 PM
Avg °F
Min °F
Max °F 50.3 50.7 51.9 52.2
Delta °F 0.5 1.7 2.0
PROBLEM "R" is the Reference point All callouts do not appear to have a concern, there is some wear within the roofing materials that maybe normal
RECOMMENDATION Have a roofer inspect and repair if necessary
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: North bathroom vent inside wall
Omaha, Nebraska 68130 SEVERITY: Low
1945 North 38th Street Lincoln NE 2016 780024.SIT • 10/13/2016
• 7:53 PM
Avg °F
Min °F
Max °F 50.3 51.6 52.1
Delta °F 1.3 1.8
RECOMMENDATION Have a roofer inspect and repair if necessary
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Facing south inside wall section
Omaha, Nebraska 68130 SEVERITY: Moderate to high
1945 North 38th Street Lincoln NE 2016 780025.SIT • 10/13/2016
• 7:54 PM
Avg °F
Min °F
Max °F 48.3 51.3 51.1
Delta °F 2.9 2.7
RECOMMENDATION Have a roofer inspect and repair if necessary
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: North section vent facing south
Omaha, Nebraska 68130 SEVERITY: Moderate
1945 North 38th Street Lincoln NE 2016 780026.SIT • 10/13/2016
• 7:54 PM
Avg °F
Min °F
Max °F 49.4 51.9
Delta °F 2.4
PROBLEM "R" is the Reference point Point #2 does not appear to have a concern, there is some
RECOMMENDATION Have a roofer inspect and repair if necessary
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Vent inside wall section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780027.SIT • 10/13/2016
• 7:55 PM
Avg °F
Min °F
Max °F 50.4 54.1 54.9 54.9
Delta °F 3.7 4.5 4.5
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Omaha, Nebraska 68130 SEVERITY: Low
1945 North 38th Street Lincoln NE 2016 780028.SIT • 10/13/2016
• 7:56 PM
Avg °F
Min °F
Max °F 50.2 51.0
Delta °F 0.8
PROBLEM "R" is the Reference point Point #2 appears to be no concern
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780029.SIT • 10/13/2016
• 7:57 PM
Ref Point Point 2 Point 3 Point 4 Point 5 Point 6
Emiss. 0.98 0.98 0.98 0.98 0.98 0.98
Avg °F
Min °F
Max °F 48.7 53.7 53.8 53.6 52.7 53.3
Delta °F 5.0 5.1 4.9 4.0 4.6
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780030.SIT • 10/13/2016
Avg °F 52.4
Min °F 47.9
Max °F 50.5 54.2 55.4
Delta °F 3.7 5.0
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Vent inside wall northern section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780031.SIT • 10/13/2016
Avg °F
Min °F
Max °F 48.9 52.6 51.9
Delta °F 3.7 3.0
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Omaha, Nebraska 68130 SEVERITY: Moderate to high
1945 North 38th Street Lincoln NE 2016 780032.SIT • 10/13/2016
• 7:58 PM
Avg °F
Min °F
Max °F 50.2 53.1
Delta °F 2.9
PROBLEM "R" is the Reference point Point #2 appears to be a potential moisture point that may infiltrate the interior materials and framework of the structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780033.SIT • 10/13/2016
• 7:59 PM
Avg °F
Min °F
Max °F 51.7 56.2 56.7 55.0
Delta °F 4.5 5.0 3.2
PROBLEM "R" is the Reference point All points appear to be a potential moisture point that may structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780034.SIT • 10/13/2016
• 7:59 PM
Avg °F 53.7
Min °F 50.0
Max °F 53.6 57.6 55.0 57.6
Delta °F 3.9 1.3 3.9
PROBLEM "R" is the Reference point All callouts appear to be a potential moisture point that may infiltrate the interior materials and framework of the structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780035.SIT • 10/13/2016
• 8:00 PM
Avg °F 52.5
Min °F 45.8
Max °F 51.9 58.4 58.4
Delta °F 6.5 6.5 structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780036.SIT • 10/13/2016
• 8:00 PM
Avg °F
Min °F
Max °F 51.8 54.5
Delta °F 2.6 structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Vent inside wall northern end section
Omaha, Nebraska 68130 SEVERITY: Low
1945 North 38th Street Lincoln NE 2016 780037.SIT • 10/13/2016
• 8:01 PM
Avg °F
Min °F
Max °F 51.1 52.1
Delta °F 1.1
PROBLEM "R" is the Reference point Point #2 appears to be a normal for vent
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Vent, east side northern section
Omaha, Nebraska 68130 SEVERITY: Moderate to high
1945 North 38th Street Lincoln NE 2016 780038.SIT • 10/13/2016
• 8:01 PM
Avg °F
Min °F
Max °F 51.4 54.1
Delta °F 2.8 structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: South central roof section with vent
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780039.SIT • 10/13/2016
• 8:02 PM
Avg °F 48.3
Min °F 43.1
Max °F 44.0 49.4 53.4
Delta °F 5.4 9.4 structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: South end of wall section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780040.SIT • 10/13/2016
• 8:03 PM
Avg °F
Min °F
Max °F 48.4 52.4 52.0
Delta °F 4.1 3.6
PROBLEM "R" is the Reference point All callouts appear to be a concern at the supports for the wall around the mechanical section of the roof top units RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: South central roof section vent
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780041.SIT • 10/13/2016
• 8:04 PM
Avg °F
Min °F
Max °F 46.3 53.5 55.5
Delta °F 7.2 9.2 structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Southeast corner roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780044.SIT • 10/13/2016
• 8:06 PM
Ref Point Point 2 Point 3 Point 4 Point 5 Poly 6 Poly 7
Emiss. 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Avg °F 44.2 45.8
Min °F 37.8 41.6
Max °F 40.6 47.3 48.3 49.2 48.0 49.2 48.7
Delta °F 6.7 7.7 8.6 7.4 8.7 8.2 structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
ThermaScan Solutions LLC LOCATION: Northeast corner roof section
Omaha, Nebraska 68130 SEVERITY: High
1945 North 38th Street Lincoln NE 2016 780046.SIT • 10/13/2016
• 8:08 PM
Avg °F
Min °F
Max °F 43.5 47.3
Delta °F 3.8 structure
RECOMMENDATION Have a roofer repair the areas that are called out to prevent potential moisture infiltration to the interior of the structure
ASSISTANT
INSPECTOR Bryan G. Dring - Level III ID#48713 CORRECTIVE ACTION TAKEN All actions are the responsibility of the property
17710 Frances Street
Omaha, NE 68130 Office (402) 964-2400 Cell (402) 660-8279
1945 North 38th Street Lincoln NE 2016 From ThermaScan Solutions LLC
10/24/2016
Image Image Date • Time Page 1945 North 38th Street Lincoln NE 2016 780001.SIT 10/13/2016 7:25 PM 1 1945 North 38th Street Lincoln NE 2016 780002.SIT 10/13/2016 7:26 PM 2 1945 North 38th Street Lincoln NE 2016 780003.SIT 10/13/2016 7:27 PM 3 1945 North 38th Street Lincoln NE 2016 780004.SIT 10/13/2016 7:27 PM 4 1945 North 38th Street Lincoln NE 2016 780005.SIT 10/13/2016 7:27 PM 5
1945 North 38th Street Lincoln NE 2016 780006.SIT 10/13/2016 7:28 PM 6 1945 North 38th Street Lincoln NE 2016 780007.SIT 10/13/2016 7:28 PM 7 1945 North 38th Street Lincoln NE 2016 780008.SIT 10/13/2016 7:29 PM 8 1945 North 38th Street Lincoln NE 2016 780009.SIT 10/13/2016 7:37 PM 9 1945 North 38th Street Lincoln NE 2016 780010.SIT 10/13/2016 7:38 PM 10 1945 North 38th Street Lincoln NE 2016 780011.SIT 10/13/2016 7:39 PM 11
1945 North 38th Street Lincoln NE 2016 780012.SIT 10/13/2016 7:39 PM 12 1945 North 38th Street Lincoln NE 2016 780014.SIT 10/13/2016 7:41 PM 13 1945 North 38th Street Lincoln NE 2016 780015.SIT 10/13/2016 7:44 PM 14 1945 North 38th Street Lincoln NE 2016 780016.SIT 10/13/2016 7:44 PM 15 1945 North 38th Street Lincoln NE 2016 780017.SIT 10/13/2016 7:45 PM 16 1945 North 38th Street Lincoln NE 2016 780018.SIT 10/13/2016 7:46 PM 17
1945 North 38th Street Lincoln NE 2016 780019.SIT 10/13/2016 7:48 PM 18 1945 North 38th Street Lincoln NE 2016 780021.SIT 10/13/2016 7:51 PM 19 1945 North 38th Street Lincoln NE 2016 780022.SIT 10/13/2016 7:51 PM 20 1945 North 38th Street Lincoln NE 2016 780023.SIT 10/13/2016 7:53 PM 21 1945 North 38th Street Lincoln NE 2016 780024.SIT 10/13/2016 7:53 PM 22 1945 North 38th Street Lincoln NE 2016 780025.SIT 10/13/2016 7:54 PM 23
1945 North 38th Street Lincoln NE 2016 780026.SIT 10/13/2016 7:54 PM 24 1945 North 38th Street Lincoln NE 2016 780027.SIT 10/13/2016 7:55 PM 25 1945 North 38th Street Lincoln NE 2016 780028.SIT 10/13/2016 7:56 PM 26 1945 North 38th Street Lincoln NE 2016 780029.SIT 10/13/2016 7:57 PM 27 1945 North 38th Street Lincoln NE 2016 780030.SIT 10/13/2016 7:57 PM 28 1945 North 38th Street Lincoln NE 2016 780031.SIT 10/13/2016 7:57 PM 29
1945 North 38th Street Lincoln NE 2016 780032.SIT 10/13/2016 7:58 PM 30 1945 North 38th Street Lincoln NE 2016 780033.SIT 10/13/2016 7:59 PM 31 1945 North 38th Street Lincoln NE 2016 780034.SIT 10/13/2016 7:59 PM 32 1945 North 38th Street Lincoln NE 2016 780035.SIT 10/13/2016 8:00 PM 33 1945 North 38th Street Lincoln NE 2016 780036.SIT 10/13/2016 8:00 PM 34 1945 North 38th Street Lincoln NE 2016 780037.SIT 10/13/2016 8:01 PM 35
1945 North 38th Street Lincoln NE 2016 780038.SIT 10/13/2016 8:01 PM 36
1945 North 38th Street Lincoln NE 2016 780039.SIT 10/13/2016 8:02 PM 37 1945 North 38th Street Lincoln NE 2016 780040.SIT 10/13/2016 8:03 PM 38
1945 North 38th Street Lincoln NE 2016 780041.SIT 10/13/2016 8:04 PM 39 1945 North 38th Street Lincoln NE 2016 780044.SIT 10/13/2016 8:06 PM 40 1945 North 38th Street Lincoln NE 2016 780046.SIT 10/13/2016 8:08 PM 41
File details come from the government source that posted it. Updated .