NRS_RHINELANDER_REPLACEMENT DOOR.pdf
PDF 369 KB Posted
- Solicitation number
- AG-4419-S-10-0122
About this file
Modification to Specifications (Doors)
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF 30.pdf | ||
| SF 1442.pdf | ||
| WI11_dvb.htm | HTM file | |
| SF 1442 Cont..docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Amendment required for Sol. No. AG-4419-S-10-0122 To clarify what is needed for Bid Items 3, 4 & 5 Door replacements
On page seven of the specifications change the following:
Main Facility Materials & Execution
Doors Units & Combination Door/Window Units
Delete the following text:
Provide doors and, or door/ window combinations from one of the following manufacturers or approved equivalent: Provide COR with submittal for approval of door, and door/window combinations prior to purchase of materials for project installation.
Pella Andersen Hurd Jeld-Wen Kolbe & Kolbe Caradco
And replace with the following text:
A. Doors and Frames
1. Exterior Doors:
a. Standard 16 gauge, polystyrene core, hollow metal door, no lite, reinforced for closures.
b. Factory primed for field painting, submit color choices for COR approval.
2. Frames:
a. Frame Thickness: 16 gauge
b. Construction: Welded
c. Material: Steel w/ ¼” pebble texture polycarbonate glazing.
d. 2” jambs and head min.
e. Finishes: Factory prime for field painting, submit color choices for COR approval.
See attached photos and schematic drawings of the desired door units to be replaced.
EXISTING PHOTO
Existing door, side windows and frame to be replaced per specifications See schematic remove kneewallremove kneewall
REPLACEMENT DOOR #1R P AC M NT OOR #
NRS Rhinelander
Annex Insulation, Garage Roof and Main Door Replacement
AG‐4419‐S‐10‐0122
All glass panels to be replaced per specifications
Existing door and frame to be replaced per specifications
Convert this section to single pane by removing per specifications See schematic
REPLACEMENT DOOR #2
EXISTING PHOTO
single pane by removing horiz. trim as shown on schematicAll glass panels to Be replaced per specifications R P AC M NT OOR #
NRS Rhinelander Annex Insulation, Garage Roof and Main Door Replacement specifications
Side window panels to remain in placeremain in place
All metal flashing and trim to be removed as necessary and replaced Existing double doors and
REPLACEMENT DOOR #3
EXISTING PHOTO
as necessary and replaced after new door installation
Existing double doors and frame to be replaced per specifications See schematicR P AC M NT OOR #3
NRS Rhinelander Annex Insulation, Garage Roof and Main Door Replacement
File details come from the government source that posted it. Updated .