About this file

Modification to Specifications (Doors)

View the file

Other files

File Type Posted
SF 30.pdf PDF
SF 1442.pdf PDF
WI11_dvb.htm HTM file
SF 1442 Cont..docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment required for Sol. No. AG-4419-S-10-0122 To clarify what is needed for Bid Items 3, 4 & 5 Door replacements

On page seven of the specifications change the following:

Main Facility Materials & Execution

Doors Units & Combination Door/Window Units

Delete the following text:

Provide doors and, or door/ window combinations from one of the following manufacturers or approved equivalent: Provide COR with submittal for approval of door, and door/window combinations prior to purchase of materials for project installation.

Pella Andersen Hurd Jeld-Wen Kolbe & Kolbe Caradco

And replace with the following text:

A. Doors and Frames

1. Exterior Doors:

a. Standard 16 gauge, polystyrene core, hollow metal door, no lite, reinforced for closures.

b. Factory primed for field painting, submit color choices for COR approval.

2. Frames:

a. Frame Thickness: 16 gauge

b. Construction: Welded

c. Material: Steel w/ ¼” pebble texture polycarbonate glazing.

d. 2” jambs and head min.

e. Finishes: Factory prime for field painting, submit color choices for COR approval.

See attached photos and schematic drawings of the desired door units to be replaced.

EXISTING PHOTO

Existing door, side windows and frame to be replaced per specifications See schematic remove kneewallremove kneewall

REPLACEMENT DOOR #1R P AC M NT OOR #

NRS Rhinelander

Annex Insulation, Garage Roof and Main Door Replacement

AG‐4419‐S‐10‐0122

All glass panels to be replaced per specifications

Existing door and frame to be replaced per specifications

Convert this section to single pane by removing per specifications See schematic

REPLACEMENT DOOR #2

EXISTING PHOTO

single pane by removing horiz. trim as shown on schematicAll glass panels to Be replaced per specifications R P AC M NT OOR #

NRS Rhinelander Annex Insulation, Garage Roof and Main Door Replacement specifications

Side window panels to remain in placeremain in place

All metal flashing and trim to be removed as necessary and replaced Existing double doors and

REPLACEMENT DOOR #3

EXISTING PHOTO

as necessary and replaced after new door installation

Existing double doors and frame to be replaced per specifications See schematicR P AC M NT OOR #3

NRS Rhinelander Annex Insulation, Garage Roof and Main Door Replacement